• Title/Summary/Keyword: Esthet X

Search Result 22, Processing Time 0.024 seconds

THE STUDY ON THE COLOR STABILITY OF COMPOSITE RESIN (수종 복합레진의 색안정성에 관한 연구)

  • Kim Hye-Jin;Kim Kwang-Jun;Cho Hye-Won;Jin Tai-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.1
    • /
    • pp.79-87
    • /
    • 2002
  • The purpose of this study was to investigate the color stability of composite resins used widely as esthetic restorative material. Surefil(Dentsply, U.S.A.), Esthet X(Dentsply, U.S.A.), Filtek P60(3M, U.S.A.) , Filtek Z250(3M, U.S.A.), Synergy Compact(Coltene, Switzerland), and Synergy Duo(Coltene, Switzerland) were chosen for this study. Thirty six specimens($7mm{\times}2mm$) of each composite resin were fabricated and polished after polymerization. Treatment conditions designed for this study were thermocycling, methylene blue staining, and filtered coffee staining. The color changes before and after treatment were measured by colorimeter(colorimeter, Model Tc-6Fx, Tokyo Denshoku Co.) and analyzed. The followings were drawn from this study: 1. The color changes of Filtek Z250, Surefil, Filtek P60 and Esthet X after thermocycling for 3 weeks were greater than those of the others. 2. The color changes of Surefil and Esthet X after methylene blue stainig and those of Surefil, Filtek Z250 and Filtek P60 after coffee staining were great. 3. The color changes or Synergy Duo and Synergy Compact after thermocycling and coffee staining were relatively lesser than those of other composite resins.

INFLUENCE OF THE SURFACE ROUGHNESS ON TRANSLUCENCY AND SURFACE COLOR OF THE DENTAL COMPOSITE RESINS (복합레진의 표면 거칠기에 따른 투명도와 표면 색상의 차이에 관한 연구)

  • Cho Kyu-Jeong;Park Su-Jung;Cho Hyun-Gu;Kim Dong-Jun;Hwang Yun-Chan;Oh Won-Mann;Hwang In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.4
    • /
    • pp.312-322
    • /
    • 2006
  • The objectives of this study were to evaluate the effect of surface roughness on the surface color and translucency of the composite resins. Two composite resins (Esthet-X, Dentsply, Milford, USA and Charisma, Kulzer, Domagen, Germany) were used to investigate the surface color. Charisma was used to investigate the translucency. 40 disc samples (diameter: 8 mm, thickness: 5 mm) were made by each product to measure the surface color. Polymerized each sample's one side was treated by Sof-Lex finishing and polishing system (Group C, M, F, SF). 40 disc samples (diameter: 6 mm, thickness: 1 mm) were prepared to measure the opacity. 1 mm samples were ground one side with #600, #1000, #1500 and #2000 sandpapers. CIE $L^{*}a^{*}b^{*}$ values of each 5 mm thickness samples, and XYZ values of 1 mm thickness samples on the white and black background were measured with spectrophotometer (Spectrolino, GretagMacbeth, Regensdorf, Switzerland). Mean surface roughness (Ra) of all samples before and after surface treatment was measured using the Surface Roughness Tester SJ-301 (Mytutoyo, Tokyo, Japan). Regardless of type and shade of the composite resin, $L^{*}$ values measured in group C were higher than others (p < 0.05), and $L^{*}$ value decreased as the Ra value decreased except B3 shade of Esthet-X. But there were no significant difference in $a^{*}$ values among groups. In control group and SF, highest $b^{*}$ values were measured (p < 0.05), except B1 shade of Esthet-X. Contrast ratio decreased as the Ra value decreased (p < 0.05). With the above results, difference of surface roughness has influence on surface color and translucency of dental composite resins.

Microhardness and microleakage of composite resin according to the change of curing light intensity (다양한 중합광도에 따른 복합레진의 미세 경도와 변연 누출도)

  • Soo-man Park;Dong-Hoon Shin
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.5
    • /
    • pp.363-371
    • /
    • 2001
  • 심미성 수복재 중합시 사용되는 광원은 다양한 요인들에 의해 선택되어지고 있지만 이러한 요인들은 앞으로도 논란의 여지를 많이 남겨두고 있다. 또한 현재 사용되고 있는 중합법들이 제각기 독특한 장점들을 갖고 있기 때문에 최적의 중합법 결정이 필요한 시점이다. 이에 본 연구에서는 중합광의 강도(50, 100, 200, 300, 400, 600mW/$\textrm{cm}^2$)와 중합시간(10, 20, 40초)을 다양하게 변화시켰을 때 복합레진의 미세경도와 미세누출도가 어떠한 양태를 보이는지를 관찰하고자 하였다. 본 실험에서는 A3 색상의 혼합형 복합레진인 국산 DenFil과 미세입자형 복합레진인 Esthet X를 사용하였다. 중합 1일 후 복합레진의 Vickers 경도는 다이아몬드형 압흔 길이를 측정하여 평가하였으며 미세누출도는 1% methylene blue용액을 이용한 방법과 주사전자 현미경을 이용한 수복물과 치질간의 최대 이개도 평가법의 두 가지 방법으로 측정하였다. 본 연구의 결과는 다음과 같다; 1. 미세경도는 시편 상면이 하면에 비해 단단한 양태를 보였으며 상, 하면에 관계없이 혼합형 복합레진인 국산 DenFil이 미세입자형 복합레진인 Esthetx에 비해 높은 경도치를 보였다. 2. 모든 미세 경도 실험에서 너무 낮은 광도(50mW/$\textrm{cm}^2$, 100mW/$\textrm{cm}^2$)로 중합한 군에서는 대조군에 비해 유의하게 낮은 미세 경도를 보였다(p<0.05). 3. 상면의 경우, DenFil은 중합시간과 관계없이 200mW/$\textrm{cm}^2$ 이상의 광도에서 대조군(600mW/$\textrm{cm}^2$ 광도로 40초간 중합)과 유의차 없는 미세경도치를 보였으나, Esthet X는 200mW/$\textrm{cm}^2$ 이상의 광도로 40초 동안 중합한 군에서만 대조군과 유의차 없는 미세경도치를 보였다. 4. 하면의 경우 DenFil은 300mW/$\textrm{cm}^2$ 이상의 광도로, Esthet X는 200mW/$\textrm{cm}^2$ 이상의 광도로 각기 40초 동안 중합한 군에서만 대조군과 유의차 없는 미세경도치를 보였다. 5. 법랑질 변연부에서는 색소 침투가 전혀 없었으나 상아질 변연부에서는 정도의 차이는 있었지만 모든 시편에서 색소 침투를 보였다. 6. 통계적 유의차는 없었지만 저광도에서 우수한 미세누출도를 보였으며 색소 침투법과 최대 이개도 평가법간에는 상관성이 매우 낮았다 (p=0.801).

  • PDF

Microhardness and microleakage of composite resin according to the change of curing light intensity

  • Park, Soo-Man;Shin, Dong-Hoon
    • Proceedings of the KACD Conference
    • /
    • 2001.11a
    • /
    • pp.586.2-586
    • /
    • 2001
  • The selection of a curing light is a multifactorial decision. While each method of polymerization presents unique clinical benefits, the optimal light-curing technique remains to be determined. The objective of this study was to check the difference of micro hardness and microleakage according to various light intensity (50, 100, 200, 300, 400, 600 ㎽/$\textrm{cm}^2$) and curing time (10, 20, 40 seconds). A3 color of two composite resin, hybrid type DenFil and submicron type Esthet X were tested.(중략)

  • PDF

Thickness and translucency of opaque shade composite resin for masking effect (배경 색조 차단 목적의 불투명 복합 레진의 두께와 반투명도)

  • Baek, Kyung-Won;Kim, Sung-Joon
    • The Journal of the Korean dental association
    • /
    • v.49 no.4
    • /
    • pp.203-210
    • /
    • 2011
  • The aims of this study were to evaluate the adequate thickness of opaque resins for situations such as an oral black cavity and discolored tooth structure, as well as the translucency of each opaque material at various thicknesses. Six opaque-shade composite resins (Z-350 OA3, Amelogen Universal A2O, Esthet-X A2O, Esthet-X A4O, Charmfil UO and Aelite Universal OA3) were prepared in metal molds with a hole of 8 mm in diameter and various thicknesses (0.5mm, 1.0mm, 1.5mm, 2.0mm, 2.5mm, 3.0 mm and 4.0mm). Four backgrounds (white tile, black tile, C4 shade porcelain and opaque resin itself) were used to determine the translucency parameter (between black and white backgrounds). and to mimic a black oral cavity (between black and opaque resin backgrounds) and a discolored tooth structure (between C4 and opaque resin backgrounds). Color measurements were made by a colorimeter to determine the CIELAB values of each specimen with each background and to calculate the translucency parameter and ${\Delta}E^*$ value difference among the specimens on the backgrounds. The translucency parameter and ${\Delta}E^*$ obtained between black and opaque resin backgrounds decreased in similar pattern as thickness increased. A C4 background was masked by resin thicknesses of 0.5-1.0mm, while a black background required thicknesses of 1.0-2.0mm. Adequate knowledge about differences in the optical character like translucency of the materials used is essential, together with the accumulated experience of the individual clinician.

OPACITY AND MASHING EFFECT OF THE OPAQUE SHADE COMPOSITE RESINS (Opaque shade 복합레진의 opacity와 배경 색상 차단 능력의 평가)

  • Park, Su-Jung;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.4
    • /
    • pp.356-364
    • /
    • 2007
  • The purpose of this study was to assess the background color-interceptive ability ana opacity of opaque shade composites (Universal composite, Filtek Z350, Charisma, Clearfil ST, Palpaque Estelite, Esthet-X, and Metafil Flo). Twenty four background specimens (diameter 5.5 mm, thickness 3.0 mm) with Root dentin Mustard (Bisco, Schaumburg, IL, USA) were made. The CIE $L^*a^*b^*$ value of background specimens was measured by a spectrophotometer (Spectrolino, GretagMacbeth, Regensdorf, Switzerland). Three specimens in every group were filled on the background specimens. The surface color of samples was measured by a spectrophotometer in 3.0 mm and every thickness to 0.5 mm while grinding. The color difference in the background color along with 3.0 mm specimen gauged the masking effect in each thickness while grinding and polishing. The opacity was calculated in 1 mm thick specimens. The opacity was in the decreasing order of Clearfil ST, Metafil Flo, Filtek Z350, Palpaque Estelite, Universal composite, Charisma, and Esthet-X (p < 0.05). As the thickness get reduced, $L^*$ value showed decreasing, $a^*$ increasing tendency. The surface color difference between pair of the 3.0 mm thick specimen and after grinding in same opaque resin was above 3.3 except Clearfil ST and Metafil Flo. The color difference (${\Delta}E^*$) between pair of background specimen and opaque resin built-up specimen showed more than 10.0 regardless kinds and thickness. The variance in opacity characteristics and color of the opaque composites is dependent upon manufacturer. When using the opaque resin, the optical properties of each material must be considered as well as cavity.

The Effect of Cavity Configuration on the Mechanical Properties of Resin Composites.

  • Ryu, G.J.;Park, S.J.;Choi, K.K.
    • Proceedings of the KACD Conference
    • /
    • 2001.11a
    • /
    • pp.576.1-576
    • /
    • 2001
  • The objective of this study was to evaluate the effect of configuration of cavity on the mechanical properties such as flexural strength and elastic modulus of resin composites. The materials used were $Clearfil^{TM}$ AP-X(Kuraray, Japan) and $Esthet-X^{TM}$(Dentsply, USA) as resin composite. Dentin-bonding systems used in the study were $Clearfil^{TM}$ SE Bond(Kuraray, Japan) and Prime & Bond $NT^{TM}$(Dentsply, USA). The specimens were prepared as 6 groups with 2 control groups and 4 experimental groups.(omitted)

  • PDF

MICROHARDNESS AND MICROLEAKAGE OF COMPOSITE RESIN CURED BY VISIBLE LIGHT WITH VARIOUS BAND OF WAVELENGTH (다양한 파장폭의 가시광선에 의해 중합된 복합레진의 미세경도와 변연누출도)

  • Park, Soo-Man;Lee, Jae-Yong;Han, Seung-Ryul;Ha, Sang-Yoon;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.4
    • /
    • pp.403-410
    • /
    • 2002
  • Several ways of curing are being tried to improve material's properties and reduce marginal gap. However, all are considering about the pattern of light intensity. It was noted from the preliminary study the change of light wavelength from filter changing may give an impact on material's property and microleakage. The object of this study was to verify the effect of filters with various wavelength width on the microhardness and microleakage of composite resin ; hybrid type of DenFil and submicron hybrid type of Esthet X. Composite resins were cured using 3 kinds of filter; narrow-banded(465-475 nm), mid-banded(430-470 nm), wide-banded(400-500 nm). After the estimation of microhardness. degree of dye penetration and the maximum gap from SEM evaluation were done between 4 groups that showed no difference in microhardness value of the lower surface . The results were as follows : 1 Adequate microhardness could not be gained with a narrow-banded filter irrespective of curing time. At the upper surface, DenFil should be polymerized with middle or wide-banded filter for 20 seconds at least, while Esthet X be col$.$ed with middle or wide-banded filter for 30 seconds at least to get simitar hardness value to control group. 2. There was little dye penetration in enamel margin, but all dentin margins skewed much more dye penetration irrespective of curing conditions. Although there was no statistical difference, groups cured with mid-banded filter for 40 seconds and with wide-width filter for 20 seconds showed relatively less dye penetration. 3. It was revealed from the SEM examination that group cured with wide-banded filter had the smallest gap without statistical significance. Spearman's rho test showed that the correlation between the results of dye penetration and SEM examination was very low. From these results, it could be concluded that curing with wide-width filter would be better than the other techniques, even though the curing technique using mid-width filter seems to have its own unique advantage.

Optical characteristics of resin composite before and after polymerization (광중합 전후 복합레진의 광학적 특성)

  • Eom, Ah-Hyang;Kim, Duck-Su;Lee, Soo-Hee;Byun, Chang-Won;Park, Noh-Hoon;Choi, Kyoung-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.3
    • /
    • pp.219-230
    • /
    • 2011
  • Objectives: The aim of this study was to evaluate the optical characteristics such as color and translucency changes before and after light curing, to quantify the CQ and to measure refractive indices of body and opaque shade of resin composites materials. Materials and Methods: Resin composites used in this study were A2 body and A2 opaque shade of Esthet-X, Filtek supreme, Gradia Direct, Clearfil Majesty and Beautifil II. Color and translucency changes before and after light curing were evaluated by colorimeter, the CQ was quantified by GC-MS and refractive index changes were measured by spectroscopic ellipsometer. Results: Translucency parameter (TP) was significantly increased after curing. The CQ content of body shades are higher than that of opaque shades in all resin composites. Refractive index increased after polymerization in all materials and significant difference in ${\Delta}$refractive index was found between body and opaque shade (significance level 0.05). Conclusions: For an accurate shade match, direct shade matching of resin composite should be performed by using the cured material.

INFLUENCE OF THE SHADE GUIDE DESIGN ON COLOR HATCHING (Shade guide의 형태가 색상 결정에 미치는 영향)

  • Park, Geol;Kim, Dong-Jun;Lee, Shee-Eun;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.3
    • /
    • pp.170-177
    • /
    • 2005
  • This study was conducted in order to assess whether the form of the shade guide affects in deciding the color of the teeth using the shade guide Eight shade light cured composite resins (Esthet-X, Dentsply, Milford, USA) were used in this study. Shade guides including the model of maxillary central incisors, teeth-form shade guide, doughnut form shade guide, and shade guide with perforated gray shield were prepared with eight shade composite resins and provided the codes randomly After arranging the models of teeth, 19 dentists working at the clinic of the Dentistry of Chonnam University Hospital and 65 students of college of dentistry, Chonnnam University selected the shade guides corresponding to the color of each tooth on the gray board under the D$_{65}$ standard illuminant. Bl shade showed highest accuracy of about 95% among all shade guides of 3 forms applied to the test and regardless of observer, tooth form shade guide showed the highest accuracy (p < 0.05) , and the doughnut form showed the lowest accuracy (p < 0.05). At the time of deciding on the color of the teeth using the shade guides as a result of above, the forms of the shade guides can affect the accuracy, and it suggests that the development of the diversified forms of shade guides, which may obtain more accurate results, is required.