• 제목/요약/키워드: Esthet X

검색결과 22건 처리시간 0.023초

수종 복합레진의 색안정성에 관한 연구 (THE STUDY ON THE COLOR STABILITY OF COMPOSITE RESIN)

  • 김혜진;김광준;조혜원;진태호
    • 대한치과보철학회지
    • /
    • 제40권1호
    • /
    • pp.79-87
    • /
    • 2002
  • The purpose of this study was to investigate the color stability of composite resins used widely as esthetic restorative material. Surefil(Dentsply, U.S.A.), Esthet X(Dentsply, U.S.A.), Filtek P60(3M, U.S.A.) , Filtek Z250(3M, U.S.A.), Synergy Compact(Coltene, Switzerland), and Synergy Duo(Coltene, Switzerland) were chosen for this study. Thirty six specimens($7mm{\times}2mm$) of each composite resin were fabricated and polished after polymerization. Treatment conditions designed for this study were thermocycling, methylene blue staining, and filtered coffee staining. The color changes before and after treatment were measured by colorimeter(colorimeter, Model Tc-6Fx, Tokyo Denshoku Co.) and analyzed. The followings were drawn from this study: 1. The color changes of Filtek Z250, Surefil, Filtek P60 and Esthet X after thermocycling for 3 weeks were greater than those of the others. 2. The color changes of Surefil and Esthet X after methylene blue stainig and those of Surefil, Filtek Z250 and Filtek P60 after coffee staining were great. 3. The color changes or Synergy Duo and Synergy Compact after thermocycling and coffee staining were relatively lesser than those of other composite resins.

복합레진의 표면 거칠기에 따른 투명도와 표면 색상의 차이에 관한 연구 (INFLUENCE OF THE SURFACE ROUGHNESS ON TRANSLUCENCY AND SURFACE COLOR OF THE DENTAL COMPOSITE RESINS)

  • 조규정;박수정;조현구;김동준;황윤찬;오원만;황인남
    • Restorative Dentistry and Endodontics
    • /
    • 제31권4호
    • /
    • pp.312-322
    • /
    • 2006
  • 본 연구는 복합레진의 표면 연마에 의한 표면 거칠기가 표면 색상과 투명도에 어떤 영향을 미치는가를 알아보고자 시행하였다. Charisma (Heraeus Kulzer GmbH, Domagen, Germany)의 B1과 A3, Esthet-X (DENTSPLY Caulk, Milford, USA)의 B1과 B3 레진으로 거칠기에 따른 표면 색상을 평가하기위한 직경 8 mm, 두께 5 mm의 시편을 제작하고, Sof-Lex finishing & polishing system (3M, ESPE Dental Products, St. Paul, USA)의 C, M, F 및 SF 디스크로 시편의 한쪽 면을 연마하였으며, 연마 전 Mylar strip으로 압축된 면을 대조군으로 하였다 . 거칠기에 따른 투명도의 차이를 평가하기위한 두께 1 mm의 시편을 Charisma 의 A3로 제작하여, 한쪽 면을 600, 1000. 1500 및 2000번 사포로 연마하였다. 각 시편의 연마 전과 후, 연마면의 CIE $L^{*}a^{*}b^{*}$ 값과 1 mm 시편의 백색과 흑색 배경판 상에서의 Y값을 spectrophotometer 인 Spectrolino (GretagMacbeth, Regensdorf, Switzerland)를 사용해 측정 분석하였으며, 각 시편의 연마 전과 후의 평균 표면 조도 (Ra)값을 Surface Roughness Tester SJ-301 (Mytutoyo, Tokyo, Japan)로 측정했다. $L^{*}$값은 재료와 색상에 상관없이 가장 거친 Sof-lex C 디스크로 연마한 군에서 가장 높은 값을 보였으며 (p < 0.05), Esthet-X B3군을 제외한 모든 군에서 Ra값이 감소함에 따라 $L^{*}$값도 낮아졌다. $a^{*}$값은 표면 거칠기에 따라 특정한 변화양상을 보이지 않았으며, $b^{*}$값은 Esthet-X B1군을 제외한 모든 군에서 Sof-lex SF 디스크로 연마 시 가장 높은 값을 보였으며 (p < 0.05), Charisma B1과 Esthet-X B3군에서 Ra값과 비교적 높은 상관관계를 보였다. Contrast ratio 는 1000번과 1500번 사포로 연마한 군 간을 제외한 모든 군 간에 유의한 차이를 보였으며 (p < 0.05), 표면 거칠기가 감소함에 따라 contrast ratio도 감소하였다 (R2 = 0.801).

다양한 중합광도에 따른 복합레진의 미세 경도와 변연 누출도 (Microhardness and microleakage of composite resin according to the change of curing light intensity)

  • Soo-man Park;Dong-Hoon Shin
    • Restorative Dentistry and Endodontics
    • /
    • 제26권5호
    • /
    • pp.363-371
    • /
    • 2001
  • 심미성 수복재 중합시 사용되는 광원은 다양한 요인들에 의해 선택되어지고 있지만 이러한 요인들은 앞으로도 논란의 여지를 많이 남겨두고 있다. 또한 현재 사용되고 있는 중합법들이 제각기 독특한 장점들을 갖고 있기 때문에 최적의 중합법 결정이 필요한 시점이다. 이에 본 연구에서는 중합광의 강도(50, 100, 200, 300, 400, 600mW/$\textrm{cm}^2$)와 중합시간(10, 20, 40초)을 다양하게 변화시켰을 때 복합레진의 미세경도와 미세누출도가 어떠한 양태를 보이는지를 관찰하고자 하였다. 본 실험에서는 A3 색상의 혼합형 복합레진인 국산 DenFil과 미세입자형 복합레진인 Esthet X를 사용하였다. 중합 1일 후 복합레진의 Vickers 경도는 다이아몬드형 압흔 길이를 측정하여 평가하였으며 미세누출도는 1% methylene blue용액을 이용한 방법과 주사전자 현미경을 이용한 수복물과 치질간의 최대 이개도 평가법의 두 가지 방법으로 측정하였다. 본 연구의 결과는 다음과 같다; 1. 미세경도는 시편 상면이 하면에 비해 단단한 양태를 보였으며 상, 하면에 관계없이 혼합형 복합레진인 국산 DenFil이 미세입자형 복합레진인 Esthetx에 비해 높은 경도치를 보였다. 2. 모든 미세 경도 실험에서 너무 낮은 광도(50mW/$\textrm{cm}^2$, 100mW/$\textrm{cm}^2$)로 중합한 군에서는 대조군에 비해 유의하게 낮은 미세 경도를 보였다(p<0.05). 3. 상면의 경우, DenFil은 중합시간과 관계없이 200mW/$\textrm{cm}^2$ 이상의 광도에서 대조군(600mW/$\textrm{cm}^2$ 광도로 40초간 중합)과 유의차 없는 미세경도치를 보였으나, Esthet X는 200mW/$\textrm{cm}^2$ 이상의 광도로 40초 동안 중합한 군에서만 대조군과 유의차 없는 미세경도치를 보였다. 4. 하면의 경우 DenFil은 300mW/$\textrm{cm}^2$ 이상의 광도로, Esthet X는 200mW/$\textrm{cm}^2$ 이상의 광도로 각기 40초 동안 중합한 군에서만 대조군과 유의차 없는 미세경도치를 보였다. 5. 법랑질 변연부에서는 색소 침투가 전혀 없었으나 상아질 변연부에서는 정도의 차이는 있었지만 모든 시편에서 색소 침투를 보였다. 6. 통계적 유의차는 없었지만 저광도에서 우수한 미세누출도를 보였으며 색소 침투법과 최대 이개도 평가법간에는 상관성이 매우 낮았다 (p=0.801).

  • PDF

Microhardness and microleakage of composite resin according to the change of curing light intensity

  • Park, Soo-Man;Shin, Dong-Hoon
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2001년도 추계학술대회(제116회) 및 13회 Workshop 제3회 한ㆍ일 치과보존학회 공동학술대회 초록집
    • /
    • pp.586.2-586
    • /
    • 2001
  • The selection of a curing light is a multifactorial decision. While each method of polymerization presents unique clinical benefits, the optimal light-curing technique remains to be determined. The objective of this study was to check the difference of micro hardness and microleakage according to various light intensity (50, 100, 200, 300, 400, 600 ㎽/$\textrm{cm}^2$) and curing time (10, 20, 40 seconds). A3 color of two composite resin, hybrid type DenFil and submicron type Esthet X were tested.(중략)

  • PDF

배경 색조 차단 목적의 불투명 복합 레진의 두께와 반투명도 (Thickness and translucency of opaque shade composite resin for masking effect)

  • 백경원;김성준
    • 대한치과의사협회지
    • /
    • 제49권4호
    • /
    • pp.203-210
    • /
    • 2011
  • The aims of this study were to evaluate the adequate thickness of opaque resins for situations such as an oral black cavity and discolored tooth structure, as well as the translucency of each opaque material at various thicknesses. Six opaque-shade composite resins (Z-350 OA3, Amelogen Universal A2O, Esthet-X A2O, Esthet-X A4O, Charmfil UO and Aelite Universal OA3) were prepared in metal molds with a hole of 8 mm in diameter and various thicknesses (0.5mm, 1.0mm, 1.5mm, 2.0mm, 2.5mm, 3.0 mm and 4.0mm). Four backgrounds (white tile, black tile, C4 shade porcelain and opaque resin itself) were used to determine the translucency parameter (between black and white backgrounds). and to mimic a black oral cavity (between black and opaque resin backgrounds) and a discolored tooth structure (between C4 and opaque resin backgrounds). Color measurements were made by a colorimeter to determine the CIELAB values of each specimen with each background and to calculate the translucency parameter and ${\Delta}E^*$ value difference among the specimens on the backgrounds. The translucency parameter and ${\Delta}E^*$ obtained between black and opaque resin backgrounds decreased in similar pattern as thickness increased. A C4 background was masked by resin thicknesses of 0.5-1.0mm, while a black background required thicknesses of 1.0-2.0mm. Adequate knowledge about differences in the optical character like translucency of the materials used is essential, together with the accumulated experience of the individual clinician.

Opaque shade 복합레진의 opacity와 배경 색상 차단 능력의 평가 (OPACITY AND MASHING EFFECT OF THE OPAQUE SHADE COMPOSITE RESINS)

  • 박수정;황윤찬;오원만;황인남
    • Restorative Dentistry and Endodontics
    • /
    • 제32권4호
    • /
    • pp.356-364
    • /
    • 2007
  • 본 연구에서는 현재 임상에 사용되고 있는 opaque shade 복합레진의 opacity와 배경색 차단 능력을 평가하였다. 24개의 배경 시편 (직경 5.5 mm, 두께 3 mm)을 Tescera ATL Root dentin Mustard로 제작하고 배경판 레진 상에 7종의 opaque shade 복합레진 (Universal composite, Filtek Z350, Charisma, Clearfil ST, Palpaque Estelite, Esthet-X, Metafil Flo)과 통상적인 복합레진인 Estelite Sigma를 3.0 mm 적층 수복하였다. 적층된 opaque shade 복합레진의 표면 색상을 측정한 후, 적층한 두께가 0.5 mm가 될 때까지 0.3 mm 간격으로 적층된 면을 연마하면서 각 두께에서의 표면 색상을 측정하였다. 연마 후 각 두께에서 측정된 opaque shade 복합레진의 표면 색상과 적층 전의 배경판 색상, 그리고 연마전의 표면 색상 간의 색차를 계산하여 두께에 따른 배경색 차단 능력을 평가하였다. 또한 1 mm 두께의 시편을 제작하고 opacity를 측정하여 다음의 결과를 얻었다. Opaque shade 복합레진의 opacity는 Clearfil ST, Metafil Flo, Filtek Z350, Palpaque Estelite, Universal composite, Charisma, Esthet-X 순으로 감소하였다 (p < 0.05). Opaque shade 복합레진의 두께의 감소에 따라 $L^*$ 값은 감소하는 양상을, $a^*$ 값은 증가하는 양상을 보였다. 연마 전 표면 색상과 연마 후 각 두께에서의 색차 (${\Delta}E^*$)는 Clearfil ST 군은 모든 군에서, Metafil Flo 군은 1.0 mm 이상에서 3 이하의 색차를 보였다. 배경 색상에 대한 각 opaque shade 복합레진의 색차는 모든 두께에서 10 이상의 색차를 보였으며, Clearfil ST와 Metafil Flo가 가장 큰 색차를 보였다 (p < 0.05). 현재 임상에 사용되고 있는 opaque shade 복합레진들은 제조사에 따라 서로 다른 opacity와 색상을 가진다. 따라서 재료의 선택에 있어 적용하고자 하는 병소의 특성에 따라 opaque shade 복합레진의 opacity와 색상에 대한 충분한 고려가 필요하리라 사료된다.

The Effect of Cavity Configuration on the Mechanical Properties of Resin Composites.

  • Ryu, G.J.;Park, S.J.;Choi, K.K.
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2001년도 추계학술대회(제116회) 및 13회 Workshop 제3회 한ㆍ일 치과보존학회 공동학술대회 초록집
    • /
    • pp.576.1-576
    • /
    • 2001
  • The objective of this study was to evaluate the effect of configuration of cavity on the mechanical properties such as flexural strength and elastic modulus of resin composites. The materials used were $Clearfil^{TM}$ AP-X(Kuraray, Japan) and $Esthet-X^{TM}$(Dentsply, USA) as resin composite. Dentin-bonding systems used in the study were $Clearfil^{TM}$ SE Bond(Kuraray, Japan) and Prime & Bond $NT^{TM}$(Dentsply, USA). The specimens were prepared as 6 groups with 2 control groups and 4 experimental groups.(omitted)

  • PDF

다양한 파장폭의 가시광선에 의해 중합된 복합레진의 미세경도와 변연누출도 (MICROHARDNESS AND MICROLEAKAGE OF COMPOSITE RESIN CURED BY VISIBLE LIGHT WITH VARIOUS BAND OF WAVELENGTH)

  • 박수만;이재용;한승렬;하상윤;신동훈
    • Restorative Dentistry and Endodontics
    • /
    • 제27권4호
    • /
    • pp.403-410
    • /
    • 2002
  • Several ways of curing are being tried to improve material's properties and reduce marginal gap. However, all are considering about the pattern of light intensity. It was noted from the preliminary study the change of light wavelength from filter changing may give an impact on material's property and microleakage. The object of this study was to verify the effect of filters with various wavelength width on the microhardness and microleakage of composite resin ; hybrid type of DenFil and submicron hybrid type of Esthet X. Composite resins were cured using 3 kinds of filter; narrow-banded(465-475 nm), mid-banded(430-470 nm), wide-banded(400-500 nm). After the estimation of microhardness. degree of dye penetration and the maximum gap from SEM evaluation were done between 4 groups that showed no difference in microhardness value of the lower surface . The results were as follows : 1 Adequate microhardness could not be gained with a narrow-banded filter irrespective of curing time. At the upper surface, DenFil should be polymerized with middle or wide-banded filter for 20 seconds at least, while Esthet X be col$.$ed with middle or wide-banded filter for 30 seconds at least to get simitar hardness value to control group. 2. There was little dye penetration in enamel margin, but all dentin margins skewed much more dye penetration irrespective of curing conditions. Although there was no statistical difference, groups cured with mid-banded filter for 40 seconds and with wide-width filter for 20 seconds showed relatively less dye penetration. 3. It was revealed from the SEM examination that group cured with wide-banded filter had the smallest gap without statistical significance. Spearman's rho test showed that the correlation between the results of dye penetration and SEM examination was very low. From these results, it could be concluded that curing with wide-width filter would be better than the other techniques, even though the curing technique using mid-width filter seems to have its own unique advantage.

광중합 전후 복합레진의 광학적 특성 (Optical characteristics of resin composite before and after polymerization)

  • 엄아향;김덕수;이수희;변창원;박노훈;최경규
    • Restorative Dentistry and Endodontics
    • /
    • 제36권3호
    • /
    • pp.219-230
    • /
    • 2011
  • 연구목적: 복합레진의 광중합 전후에 일어나는 색과 투명도 변화를 측정하고, CQ의 함량을 정량하였으며, 광중합 전후 복합 레진의 굴절률을 측정해 이들의 상관 관계를 알아보고자 하였다. 연구 재료 및 방법: Esthet-X, Filtek supreme, Gradia Direct, Clearfil Majesty, Beautifil II에 대하여 Colorimeter NF999를 이용하여 광중합 전후의 색과 투명도를 각각 측정하고, GC-MS를 이용해 각 복합레진의 CQ 함량을 측정하였으며, spectroscopic ellipsometer를 이용해 광중합 전후의 굴절률을 측정하였다. 결과: 투명도는 광중합 후에 증가하였고, body shade에서 opaque shade보다 투명도 차이가 크게 나타났다. 모든 레진에서 body shade의 CQ 함량이 opaque shade의 CQ 함량보다 높았다. 굴절률은 광중합 후에 모든 레진에서 증가하였으며, body shade와 opaque shade간에 굴절률의 변화는 유의한 차이가 있었다. 결론: 광중합 후에는 복합레진의 색과 투명도가 상당한 차이를 나타낸다. 따라서 임상에서 direct shade matching을 시행할 때는 중합된 레진을 사용하여야 한다.

Shade guide의 형태가 색상 결정에 미치는 영향 (INFLUENCE OF THE SHADE GUIDE DESIGN ON COLOR HATCHING)

  • 박걸;김동준;이시은;황윤찬;오원만;황인남
    • Restorative Dentistry and Endodontics
    • /
    • 제30권3호
    • /
    • pp.170-177
    • /
    • 2005
  • 본 연구에서는 shade guide를 이용하여 치아의 색상을 결정하는데 있어 shade guide의 형태가 미치는 영향을 평가 하기 위해 시행하였다 8가지 서로 다른 색상 code (Al, A2, Bl, B2, B3, C2, C3, D3)를 사용하는 광중합 복합레진 (Esthet-X, Dentsply, USA)을 이용하여 각 색상마다 상악 중절치 모형, 치아형 shade guide, 도넛형 shade guide, 및 회색 shield를 포함하는 shade guide를 제작하고 무작위로 기호를 부여하였다. 제작된 치아 모형을 배열하고 전남 대학교병원 치과 진료처에 근무하는 19명의 수련의와 전남대학교 치과대학 2, 3학년 학생 65명을 대상으로 회색 배경 판과 D$_{65}$ 표준광 하에서 각 치아의 색상과 일치하는 shade guide를 선택하게 하였다. 연구 결과 Bl 색상은 실험에 적용한 3가지 형태의 모든 shade guide에서 약 95%의 가장 높은 정확도를 보였으며 , 색상간 색차가 가장 적은 B2와 C2는 3가지 형태의 모든 shade guide에서 서로 비슷한 정도의 교차 선택율을 보였다. 또한 관찰자에 상관없이 치아 형태의 shade guide는 가장 높은 정확도를 보인 반면 (p < 0.05), 도넛 형태의 shade guide는 가장 낮은 정확도를 보였다 (p <0.05).