• Title/Summary/Keyword: Error level

Search Result 2,511, Processing Time 0.033 seconds

Multidimensional Hydrodynamic and Water Temperature Modeling of Han River System (한강 수계에서의 다차원 시변화 수리.수온 모델 연구)

  • Kim, Eun-Jung;Park, Seok-Soon
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.6
    • /
    • pp.866-881
    • /
    • 2012
  • Han River is a complex water system consisting of many lakes. The water quality of Lake Paldang is significantly affected by incoming flows, which are the South and North branches of the Han River, and the Kyungan Stream. In order to manage the water quality of the Lake Paldang, we should consider the entire water body where the incoming flows are included. The objectives of this study are to develop an integrated river and lake modeling system for Han River system using a multidimensional dynamic model and evaluate the model's performance against field measurement data. The integrated model was calibrated and verified using field measurement data obtained in 2007 and 2008. The model showed satisfactory performance in predicting temporal variations of water level, flow rate and temperature. The Root Mean Square Error (RMSE) for water temperature simulation were $0.88{\sim}2.13^{\circ}C$ (calibration period) and $1.05{\sim}2.00^{\circ}C$ (verification period) respectively. And Nash-Sutcliffe Efficiency (NSE) for water temperature simulation were 1089~0.98 (calibration period) and 0.90~0.98 (verification period). Utilizing the validated model, we analyzed the spatial and temporal distributions of temperature within Han River system. The variations of temperature along the river reaches and vertical thermal profiles for each lakes were effectively simulated with developed model. The suggested modeling system can be effectively used for integrated water quality management of water system consisting of many rivers and lakes.

Quality Control for Radioimmunoassay of Cyclosporine (Cyclosporine 방사면역측정법의 정도관리)

  • Jeong, Jae-Min;Seo, Il-Tack;Moon, Dae-Hyuk;Chung, June-Key;Lee, Myung-Chul;Cho, Bo-Youn;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.23 no.2
    • /
    • pp.225-230
    • /
    • 1989
  • According to the development of monoclonal antibodies against cyclosporine, it became available to replace the conventional polyclonal antibody method with new monoclonal antibody method to measure the blood level of cyclosporine by radioimmunoassay. We compared the results obtained by the two methods: polyclonal antibody and monoclonal antibody method. The results were obtained as follows: 1) We obtained mean value 137.3 ng/ml and CV 16.1% from plasma sample, and mean values 495.7 ng/ml and 1053.8 ng/ml and CVs 19.3% and 17.4% respectively from whole blood sample by polyclonal antibody method. 2) For the two control groups, 100 ng/ml 400 ng/ml each, we obtained that the CVs were 20.2% and 14.0% respectively from plasma sample, and 11 9% and 13.1% respectively from whole blood sample by monoclonal antibody method. In conclusion, we found that cyclosporine RIA was a relatively reliable method to measure blood or plasma concentration. Especially RIA using monocloanl antibody showed less degree of error in measurement compared to polyclonal antibody method.

  • PDF

Estimation of Fractional Vegetation Cover in Sand Dunes Using Multi-spectral Images from Fixed-wing UAV

  • Choi, Seok Keun;Lee, Soung Ki;Jung, Sung Heuk;Choi, Jae Wan;Choi, Do Yoen;Chun, Sook Jin
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.34 no.4
    • /
    • pp.431-441
    • /
    • 2016
  • Since the use of UAV (Unmanned Aerial Vehicle) is convenient for the acquisition of data on broad or inaccessible regions, it is nowadays used to establish spatial information for various fields, such as the environment, ecosystem, forest, or for military purposes. In this study, the process of estimating FVC (Fractional Vegetation Cover), based on multi-spectral UAV, to overcome the limitations of conventional methods is suggested. Hence, we propose that the FVC map is generated by using multi-spectral imaging. First, two types of result classifications were obtained based on RF (Random Forest) using RGB images and NDVI (Normalized Difference Vegetation Index) with RGB images. Then, the result map was reclassified into vegetation and non-vegetation. Finally, an FVC map-based RF were generated by using pixel calculation and FVC map-based GI (Gutman and Ignatov) model were indirectly made by fixed parameters. The method of adding NDVI shows a relatively higher accuracy compared to that of adding only RGB, and in particular, the GI model shows a lower RMSE (Root Mean Square Error) with 0.182 than RF. In this regard, the availability of the GI model which uses only the values of NDVI is higher than that of RF whose accuracy varies according to the results of classification. Our results showed that the GI mode ensures the quality of the FVC if the NDVI maintained at a uniform level. This can be easily achieved by using a UAV, which can provide vegetation data to improve the estimation of FVC.

Am Experimental Study on Measurement of Number Density and Temperature Distributions in $C_3H_8/O_2$ Flame by UV Laser Rayleigh Scattering (UV Laser Rayleigh Scattering을 이용한 $C_3H_8/O_2$ 화염에서 가스 성분의 농도 및 온도 분포 계측에 관한 실험적 연구)

  • Jin, S. H;Nam, G. J.;Kim, H. S.;Chang, N. K.;Park, S. H.;Kim, U.;Park, K. S.;Kim, G. S.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.2
    • /
    • pp.60-68
    • /
    • 1997
  • Rayleigh Scattering Cross Sections($\sigma$i) of various gases and the temperature distributions of premixes C3H8/O2 flame are measured by high power KrF(248nm) Exci- mer laser and ICCD camera. Results show that $\sigma$i of O2 and Propane(C3H8) gases agree well in the 5% error range, but of H2 has the more or less difference from the calcul- ated value by other groups. This is attributed to the low RS signal of H2 to Nosie level(S/N ratio). The temperature distributions of flame range out between 300K in the air and about 2000K in the burned area. In this temperature range, out system has the about 250K temperature resolution. Because low RS signals in the reaction area with high temperature are affected highly by noises, temperature uncertainty of this area is relatively high to another part of flame. Experimental results show that UV Rayleigh Scattering can be used for the measurement of mixing ratio of mixed gases and the temperature distributions of flame. Especially, this technique can be applied for the measurement of the mixing ratio of air/fuel before the ignition and the flame structure after the ignition inside the Engine.

  • PDF

An Analysis on Teaching and Learning Spatial Sense in Elementary School Mathematics. (초등학교에서 지도하는 공간감각 내용에 관한 고찰)

  • Lee, Chong-Young
    • School Mathematics
    • /
    • v.7 no.3
    • /
    • pp.269-286
    • /
    • 2005
  • The purpose of this paper is to study the spatial sense that is introduced for the first time in our 7th mathematics curriculum. For this purpose, we first investigated the factors of the spatial sense ability and with this factors, we analyze the errors those was founded in elementary school students' carrying out tasks related to the spatial sense, and the contents of elementary mathematics textbook. From the analysis, we found that the teaching topics in the spatial sense is disagreed with the students' learning level and for each similar topics is cut off into not adjacent grades, connecting these topics to each other and to the other traditional geo-metric topics is not easy. we must consider this findings in the future revision of mathematics curriculum.

  • PDF

Citrus Fruits Intake and Prostate Cancer Risk: A Quantitative Systematic Review

  • Bae, Jong-Myon;Lee, Eun-Ja;Guyatt, Gordon
    • Journal of Preventive Medicine and Public Health
    • /
    • v.41 no.3
    • /
    • pp.159-164
    • /
    • 2008
  • Objectives : The purpose of this systematic review was to investigate the association between dietary intake of citrus fruits and prostate cancer risk. Methods : Authors searched electronic databases and the reference lists of publications of diet and prostate cancer studies until August 2007. All of the epidemiological studies that obtained individual data on dietary intake of citrus fruits and presented risk estimates of the association between intake of citrus fruits and risk of prostate cancer were identified and included. Using general variance-based methods, study-specific odds ratios (OR)/ relative risk (RR) and associated confidence interval (CI)/ standard error (SE) for highest versus lowest intake of citrus fruits level were extracted from each paper. Results : Eleven articles including six case-control studies, one nested case-control study and four cohort studies, proved eligible. Overall summary OR using random effect model did not show an association in risk of prostate caner with intake of citrus fruits (summary OR=1.03, 95% CI=0.89-1.19) with large heterogeneity across studies that we were unable to explain ($I^2$=67.88%). The summary ORs in case-control studies and cohort studies were 1.10 (95% CI=0.97-1.22) and 1.05 (95% CI=0.96-1.14), respectively. Conclusions : Pooled results from observational studies did not show an association between intake of citrus fruits and the risk of prostate cancer, although results vary substantially across studies.

Implementation of Filter for the Removal of Partial Volume Effect (부분용적효과 제거를 위한 Filter 구현)

  • Park, Minju;Lee, Sangbock
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.3
    • /
    • pp.139-145
    • /
    • 2015
  • When examining a patient using SPECT, gamma rays emitted from the body decrease or scatter. And when they reach the detector they spread in accordance with physical characteristics and geometric shapes of the scanner, quantitative analysis was difficult. For exact quantitative analysis of gamma rays emitted from the body, so that they must be considered to correction about PVE(partial volume effect). In this paper, sinogram filter was implemented to solve comprehensive PVE of SPECT. According to the results in which implemented filter was applied, partial volume effect caused by SPECT was removed. To compare proposed method and conventional method, PSNR(Peak Signal to Noise Ratio) was executed. As a result, proposed method was indicated as 7dB, conventional method was indicated as 14db respectively. dB(decibel) level of the proposed methods is lower, since the MSE(mean square error) becomes greater because scattered ray was removed, PSNR value is low. Therefore, by applying the proposed method for removing the PVE of SPECT imaging method, the image quality is improved.

Investigation and Analysis of Unit Industrial Water Usage Considering Latest Industrial Trend (최신 산업동향을 고려한 공업단지 사용량 원단위 분석 연구)

  • Kim, Kibum;Yu, Youngjun;Choi, Woojin;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.5
    • /
    • pp.447-457
    • /
    • 2017
  • This study derived the unit of industrial water usage reflecting the latest industry trends. Available for establishing plans such as the master plan for water supply system and analyzed changes in the basic unit by a comparison with the current basic unit values. This study analyzed 4,038 samples with a sampling error of less than 1.5 % at the 95 % confidence level after removing outliers according to a log-normal distribution. As a result, the unit of industrial water usage per site area in the whole manufacturing industry was 7.11 m3/1,000m2/d. The ten industrial categories (C10, C13, C20, C21, C22, C25, C27, C30, C32, C33) showed a similar unit value compared to before, and the four industrials categories (C11, C17, C22, C31) showed a more unit value than before. With regard to the nine industrial categories (C14, C15, C16, C18, C19, C24, C26, C28, C29), the unit value decreased. Cases that companies examined before were the same as the companies examined in this study were analyzed. The result that the changes in the unit industrial water usage were reasonable was obtained. However, in some industrial categories (C17, C14, C24, C29), the unit value was changed by a small number of companies with large-scale water use or unit value of sampling had a large deviation. It was considered necessary to survey them periodically. The unit of industrial water usage derived by the survey in this study reflects the current industrial trends in 2016. Water use in manufacturing companies has continuously changed by the development of manufacturing technologies and simplification of manufacturing processes. In order to deal with this, it is considered necessary to survey the usage of industrial water periodically from a long-term perspective.

Development of a Ventilation Model for Mushroom House Using Adiabatic Panel

  • Kim Kee Sung;Han Jin Hee;Kim Moon Ki;Nam Sang Woon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.46 no.7
    • /
    • pp.35-44
    • /
    • 2004
  • In this study, a ventilation model was developed to determine a ventilation rate for the balance of heat, moisture and $CO_{2}$ in a mushroom house. Internal and external temperature, relative humidity and $CO_{2}$ concentration were measured and used to validate the ventilation model. The effects of various environmental factors on physiological responses of mushroom were also investigated. The verified model was simulated under the observed ventilation rates with a difference of$ 0.001{\~}0.065\;m^{3}{\cdot}S^{-1}$ (relative error of $0.3{\~}18.9\%$) when external temperature varied 22.5 to $24.8^{circ}C$ and average ventilation rates was $0.35m^{3}{\cdot}S^{-1}$. The optimal conditions for mushroom growth (internal temperature $22 ^{circ}C$, relative humidity $80\%$, $CO_{2}$ concentration 1,000 ppm) were used for the model application with external temperature, relative humidity and $CO_{2}$ concentration of $27.5{\~}33.5^{circ}C$, $60\%$, and 355 ppm, respectively. Thermal balance was a important factor for an optimum ventilation up to the external temperature of $32^{circ}C$, while $CO_{2}$ concentration balance was more important over $32^{circ}C$. This suggests that humidification for moisture balance is required to maintain temperature and $CO_{2}$ concentration at an optimal level by ventilation in a mushroom house.

Application of CE-QUAL-W2 [v3.2] to Andong Reservoir: Part I: Simulations of Hydro-thermal Dynamics, Dissolved Oxygen and Density Current

  • Bhattarai, Prasid Ram;Kim, Yoon-Hee;Heo, Woo-Myoung
    • Korean Journal of Ecology and Environment
    • /
    • v.41 no.2
    • /
    • pp.247-263
    • /
    • 2008
  • A two-dimensional (2D) reservoir hydrodynamics and water quality model, CE-QUAL-W2, is employed to simulate the hydrothermal behavior and density current regime in Andong Reservoir. Observed data used for model forcing and calibration includes: surface water level, water temperature, dissolved oxygen and suspended solids concentration. The model was calibrated to the year of 2003 and verified with continuous run from 2000 till 2004. Without major adjustments, the model accurately simulated surface water levels including the events of large storm. Deep-water reservoirs, like Andong Reservoir, located in the Asian Monsoon region begin to stratify in summer and overturn in fall. This mixing pattern as well as the descending thermocline, onset and duration of stratification and timing of turnover phenomenon were well reproduced by the Andong Model. The temperature field and distinct thermocline are simulated to within $2^{\circ}C$ of observed data. The model performed well in simulating not only the dissolved oxygen profiles but also the metalimnetic dissolved minima phenomenon, a common1y occurring phenomenon in deep reservoirs of temperate regions. The Root Mean Square Error (RMSE) values of model calibration for surface water elevation, temperature and dissolved oxygen were 0.0095 m, $1.82^{\circ}C$, and $1.13\;mg\;L^{-1}$, respectively. The turbid storm runoff, during the summer monsoon, formed an intermediate layer of about 15 m thickness, moved along the metalimnion until being finally discharged from the dam. This mode of transport of density current, a common characteristic of various other large reservoirs in the Asian summer monsoon region, was well tracked by the model.