• Title/Summary/Keyword: Error level

Search Result 2,511, Processing Time 0.025 seconds

Comparison of Subjective Refraction Findings in Two Different Levels of Room Illumination Using Three Different Types of Letter Charts

  • Chen, Ai-Hong;Norazman, Fatin Nur Najwa;Buari, Noor Halilah;Ahmad, Azmir;Omar, Wan Elhami Wan
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.67-71
    • /
    • 2010
  • Purpose: The effect of two different levels of illumination and the effect of three letter chart types on subjective refraction findings were investigated. Methods: This study involved thirty Malay university students aged between 19 to 23 years old (7 males, 23 females), with their spherical refractive error ranged between plano to -7.75D astigmatism ranged from plano to -1.75D, anisometropia less than 1D and with no history of ocular injury and pathology. Monocular subjective refraction was measured under two levels of illumination (with and without room light) and with three different letter charts (Snellen letter chart, wall mounted letter chart and projected letter chart). Subjective refraction finding was calculated in spherical equivalent in unit diopter (D). Results: There was no significant effect in the subjective refraction findings with Snellen letter chart (t-test=0.15, p-value=0.88), projected letter chart (t-test=-0.19, p-value=0.85) as well as wall mounted letter chart (t-test=0.12, p-value=0.94). One Way ANOVA also revealed when the subjective refractive measures were compared under two different level of room illumination (with and without room light), no significant effect of letter chart types on subjective refraction readings with room light ($F_{2.185}$=0.11, p-value=0.89) and without room light ($F_{2.185}$=0.02, p-value=0.98). Conclusions: Subjective refraction findings were not affected whether the room light was on or off. They were also not affected by the types of letter chart used.

Propellant Consumption Estimation of Reaction Control System During Flight of KSLV-II (한국형발사체 추력기 자세제어시스템 비행 중 추진제 소모량 추정식)

  • Kang, Shin-jae;Oh, Sang-gwan;Yoon, Won-jae;Min, Byeong-joo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.7
    • /
    • pp.529-536
    • /
    • 2020
  • Reaction Control System of the third stage of the Korean Space Launch Vehicle II conducts roll control and 3 axis control throughout third stage engine start, satellite separation, and collision and contamination avoidance maneuver. Reaction control system consumes its propellant in each thruster operation. Hence, loading of proper amount of the propellant is important for mission success. It is needed to have a rough estimation method of propellant consumption during the flight. In this paper, we developed a energy equation using pressure and temperature data which are acquired in the on-board reaction control system. We constructed a test system which is similar with the on-board reaction control system to verify the energy equation. Test results using deionized water were compared with estimated propellant consumption. We also conducted an error analysis of the energy equation. We also presented the propellant consumption result of a system level operation test.

Block Ack-based Dynamic A-MPDU Aggregation Scheme in IEEE 802.11n WLAN (IEEE 802.11n WLAN에서 블록 승인 기반의 동적 A-MPDU 집적 방법)

  • Shin, In Cheol;Kim, Dong-Hoi
    • Journal of Broadcast Engineering
    • /
    • v.19 no.4
    • /
    • pp.510-520
    • /
    • 2014
  • By adopting the MAC(Media Access Control) protocol which enables to pack multiple MPDUs(MAC-level Protocol Data Units) into a single PPDU(Physical Layer Protocol Data Unit), IEEE 802.11n WLAN supports high throughput. Up to now, there have been a lot of existing channel information-based A-MPDU schemes dynamically determining the number of MSDUs according to the wireless channel condition information which is sent from the receiver to sender. However, the channel information-based scheme has a serious drawback having a high system overhead due to the frequent channel feedback information. To reduce the system overhead, the proposed BA-base dynamic A-MPDU scheme simply chooses the number of MSDUs to be retransmitted by not the frequent channel feedback information but the BA signal representing whether MPSUs belonging to the A-MPDU are received or not. Through NS-2(Network Simulator-2), we found that the proposed scheme had higher throughput and lower packet error rate than the existing fixed A-MPDU scheme.

Characteristics of Nonpoint Source Pollutant Loads from Forest watershed with Various Water Quality Sampling Frequencies (수질샘플빈도에 따른 산림유역의 비점원오염부하특성)

  • Shin, Min-Hwan;Shi, Yong-Chul;Heo, Sung-Gu;Lim, Kyoung-Jae;Choi, Joong-Dae
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.50 no.2
    • /
    • pp.65-71
    • /
    • 2008
  • A monsoon season monitoring data from June to September, 2005 of a small forested watershed located at the upstream of the North Han River system in Korea was conducted to analyze the flow variations, the NPS pollutant concentrations, and the pollution load characteristics with respect to sampling frequencies. During the 4-month period, 1,423 mm or 79.2% of annual rainfall(1,797 mm) were occurred and more than 77%, 54% and 68% of annual T-N, $NO_3$-N and T-P loads discharged. Flow rate was continuously measured with automatic velocity and water level meters and 58 water quality samples were taken and analyzed. It was analyzed that the flow volume by random measurement varied very widely and ranged from 79% to 218% of that of continuous measurement. It was recommended that flow measurement of small forested watersheds should be continuously measured with automated flow meters to precisely measure flow rates. Flow-weighted mean concentrations of T-N, $NO_3$-N and T-P during the period were 2.114 mg/L, 0.836 mg/L, and 0.136 mg/L, respectively. T-N, $NO_3$-N and T-P loads were sensitive to the number of samples. And it was analyzed that in order to measure the pollution load within the error of 10% to the true load, the rate of sampling frequency should be higher than 89.7% of the sample numbers that were required to compute the true pollution load. If it is compared to selected foreign research results, about 10 water samples for each rainfall event were needed to compute the pollution load within 10% error. It is unlikely in Korea and recommended that thorough NPS pollution monitoring studies are required to develop the standard monitoring procedures for reliable NPS pollution quantification.

A Feasibility Study on Opportunistic Interference Alignment: Improved Energy Efficiency via Power Control (기회적 간섭 정렬의 실현 가능성 연구: 전력 제어를 통한 에너지 효율성 개선)

  • Shin, Won-Yong;Yoon, Jangho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.5
    • /
    • pp.1077-1083
    • /
    • 2015
  • In this paper, we introduce an energy-efficient opportunistic interference alignment (OIA) scheme that greatly improves the sum-rates in multi-cell uplink networks. Each user employs optimal transmit vector design and power control in the sense of minimizing the amount of generated interference to other-cell base stations while satisfying a required signal quality. As our main result, it is shown that owing to the reduced interference level, the proposed OIA schemes attains larger sum-rates than those of OIA with no power control for almost all signal-to-noise ratio regions. In addition, when both zero-forcing and minimum mean square error (MMSE) detectors are employed at the receiver along with the OIA scheme, it is shown that the OIA scheme with MMSE detection shows superior performance.

Performance Analysis of LDPC code with Channel Estimation in Underwater Communication (수중통신 채널에서 채널 추정 오차에 따른 LDPC 부호 성능분석)

  • Kim, Nam-Soo;Jung, Ji-Won;Kim, Ki-Man;Seo, Dong-Hoan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.11
    • /
    • pp.2295-2303
    • /
    • 2009
  • Underwater acoustic(UWA) communication has multipath error because of reflection by sea-level and sea-bottom. The multipath of UWA channel causes signal distortion and error floor. In this paper, we proposed the compensation method of multipath effect using the impulse response of the UWA channel and then analysis the performance of channel coding such as LDPC code, concatenate code. Also we analysed the time-delay errors and estimated amplitude errors of estimated channel information and its affection on the performance. As shown in simulation results, the performance of proposed compensation method is better than the performance of conventional method.

Opportunistic Beamforming with Link Anaptation Robust to Imperfect Channel Estimation (기회적 빔포밍 시스템에서 채널 추정에 강인한 링크 적응 기법)

  • Kim, Yo-Han;Kim, Dong-Ku
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.8C
    • /
    • pp.617-626
    • /
    • 2008
  • Opportunistic Beamforming (OBF) offers a way to provide the multiuser diversity even in slow fading channel by using randomly generated beam weights, leading to the substantially reduced feedback in the form of the instantaneous SNR from users. In spite of the advantage of the reduced feedback, the imperfect channel estimation might influence the quality of the estimated SNR and channel scheduler so bad that the selected AMC level would be higher than the achievable rate of the actual channel, resulting the corruption of transmitted packet. In this paper, we propose a conservative link adaptation, where the estimated SNR is scaled down by a conservative factor which minimizes the variance of the maximum difference between the actual channel SNR and the resultant SNR. To support the proposed scheme, we analyze the statistics of the difference of the channel SNR and the estimated SNR. Simulation results show that the introduction of conservative factor achieves more than two-fold performance improvement in the presence of channel estimation error and the fairness of PF scheduler is maintained when the least squared channel estimator is applied.

A Study on Enhancement of Orbit Prediction Precision for Space Objects Using TLE (TLE를 이용한 우주물체 궤도예측 정밀도 향상 연구)

  • Yim, Hyeonjeong;Jung, Ok-Chul;Chung, Dae-Won
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.3
    • /
    • pp.270-278
    • /
    • 2014
  • This paper describes an improvement of space objects orbit prediction. To screen possible collisions between operational satellites and space objects, the TLE (Two-Line Element) was used as pseudo-measurement and than the orbit determination and orbit prediction were performed through the flight dynamics system. For determining the orbits, the state vectors were assumed by a series of TLEs within a certain period. The propagation error was analyzed according to the fitting period and a number of pseudo-observations. In order to find out the improvement of orbit prediction with the proposed method, KOMPSAT-2, 3 having the precise orbit in the meter-level range were first applied. Then the result applied to space objects under the same conditions was analyzed. As a result of the RMS error comparison with the orbit prediction of space object, the precision of orbit prediction was improved by approximately 90% for seven days prediction. The improved orbit prediction of space objects can be utilized in the daily analysis for initial screening of the close space objects at high risk.

Tropospheric Data of KASI GNSS Network (2001-2014) Based on the CODE's 2nd Reprocessing Product

  • Roh, Kyoung-Min;Park, Han-Earl;Choi, Byung-Kyu
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.9 no.3
    • /
    • pp.229-236
    • /
    • 2020
  • The trend of water vapor contents in atmosphere is one of key elements for studying climate change. The tropospheric products, i.e., ZTD values achieved through GPS data processing can retrieve the amount of water vapor with higher temporal and spatial resolution than any other instruments. In this study, the tropospheric products of KASINET for a time period from 2001 to 2014 are reprocessed using PPP strategy and the products from the CODE's 2nd reprocessing campaign. For consistency with reprocessing activities of other networks like EPN, the VMF1 mapping function and non-tidal loading effect due to atmospheric pressure are applied in the process. The reprocessing results are investigated through comparing with the CODE's 2nd reprocessing products by including some IGS stations in the process and also calculating weekly coordinate repeatability to see the quality of the processing. After removing outliers based on the variation of averaged formal error, all processed stations have similar variations of formal error about 2 mm which is lower than that of the IGS final product. Comparison results with the CODE's 2nd reprocessing products show that the overall mean difference is found to be -0.28±5.54 mm which is similar level of the previous studies. Finally, the ZTD trends of all KASINET stations are calculated and the averaged trend is achieved as 0.19 mm/yr. However, the trend of each month shows different amounts and directions from -1.26 mm/yr in May to 1.18 mm/yr in August. In conclusion, the reprocessed tropospheric product and applied strategy of this study has enough quality as one of reliable solution for a reference product for Korean Peninsula which is needed to use GPSbased tropospheric product for climate change research.

Repeat analysis of intraoral digital imaging performed by undergraduate students using a complementary metal oxide semiconductor sensor: An institutional case study

  • Yusof, Mohd Yusmiaidil Putera Mohd;Rahman, Nur Liyana Abdul;Asri, Amiza Aqiela Ahmad;Othman, Noor Ilyani;Mokhtar, Ilham Wan
    • Imaging Science in Dentistry
    • /
    • v.47 no.4
    • /
    • pp.233-239
    • /
    • 2017
  • Purpose: This study was performed to quantify the repeat rate of imaging acquisitions based on different clinical examinations, and to assess the prevalence of error types in intraoral bitewing and periapical imaging using a digital complementary metal-oxide-semiconductor(CMOS) intraoral sensor. Materials and Methods: A total of 8,030 intraoral images were retrospectively collected from 3 groups of undergraduate clinical dental students. The type of examination, stage of the procedure, and reasons for repetition were analysed and recorded. The repeat rate was calculated as the total number of repeated images divided by the total number of examinations. The weighted Cohen's kappa for inter- and intra-observer agreement was used after calibration and prior to image analysis. Results: The overall repeat rate on intraoral periapical images was 34.4%. A total of 1,978 repeated periapical images were from endodontic assessment, which included working length estimation (WLE), trial gutta-percha (tGP), obturation, and removal of gutta-percha (rGP). In the endodontic imaging, the highest repeat rate was from WLE (51.9%) followed by tGP (48.5%), obturation (42.2%), and rGP (35.6%). In bitewing images, the repeat rate was 15.1% and poor angulation was identified as the most common cause of error. A substantial level of intra- and inter-observer agreement was achieved. Conclusion: The repeat rates in this study were relatively high, especially for certain clinical procedures, warranting training in optimization techniques and radiation protection. Repeat analysis should be performed from time to time to enhance quality assurance and hence deliver high-quality health services to patients