• Title/Summary/Keyword: Ergometer

Search Result 97, Processing Time 0.029 seconds

A Study on Physical Work Capacity and Rest Allowance for Korean (한국인의 육체적 작업 능력과 휴식시간에 관한 연구)

  • U, Dong-Pil;Lee, Sang-Do;Lee, Dong-Chun
    • Journal of the Ergonomics Society of Korea
    • /
    • v.20 no.3
    • /
    • pp.37-46
    • /
    • 2001
  • The objective of this study was to investigate the physical work capacity and rest allowance for Korean males and females. Eleven males and 13 females participated in the study as subjects. An ergometer exercise test and a treadmill exercise test were conducted to measure oxygen consumption rates. The PWC values of Korean males and females were 2605.62ml/min and 1853.01ml/min in the cycle ergometer test, respectively, and 2872.10ml/min and 2057.91ml/min in the treadmill test. The PWC values of Korean females were about 70% of Korean males. The PWC values of Korean females were74.36%-78.79% of western males in the treadmill test. and 88.66%-89.32% of western males in the ergometer test. The PWC values of Korean females were 81.34%-82.98% of western females in the treadmill test, and 87.11% of western femaleles in the ergometer test. And, the results of this study showed that the rest allowance should be determined separately for male and female because of the difference in physical work capacity.

  • PDF

Effect of Rowing Ergometer Training on the Aerobic Capacity and Strength of Male High School Students (로잉 에르고미터 훈련이 남자고등학생의 유산소능력과 근력에 미치는 효과)

  • Kim, Dong-Hee;Yuk, Ji-Min;Park, Hyeok;Lim, Jae-Heon;Kim, Seok-Hwan
    • PNF and Movement
    • /
    • v.16 no.2
    • /
    • pp.187-194
    • /
    • 2018
  • Purpose: This study aimed to assess the effect of rowing ergometer training on the aerobic capacity and strength of male high school students over a 12-week period. Methods: Fourteen high school students volunteered to participate in the study. The subjects were divided into two groups: seven subjects in the experimental group and seven in the control group. The subjects in the experimental group performed rowing ergometer training for 75 min per session at three days a week for 12 weeks. The exercise intensity set the maximum heart rate (HRmax) from 40% to 80%. Aerobic capacity was measured by ventilation, cardiac output, and oxygen intake per body weight. Strength was measured by grip strength and back strength before and after training. Results: A significantly increased ventilation (p=0.01), cardiac output (p=0.01), and oxygen intake per body weight (p=0.00) were found in the experimental group. A significantly increased grip strength in the right and left hands (p=0.00, 0.00) and back strength (p=0.04) were observed in the experimental group. Conclusion: Rowing ergometer training can be an effective combined exercise for aerobic capacity and strength of high school students.

Validity on Submaximal Load Tests Using Cycle Ergometer in Evaluation of Maximum Oxygen Consumption Volume (최대 산소소모량 평가에 있어서 자전거 에르고미터를 이용한 최대하부하검사방법의 타당도)

  • Kang, Dongmug;Park, Yong Kyun;Lee, Yong Hwan;Sul, Jin Gon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.2
    • /
    • pp.145-151
    • /
    • 2006
  • Because of the limitations of maximal load tests for $VO_2max$, submaximal tests using cycle ergometer are used for field study in general. This study was conducted to evaluate validity of various submaximal tests using cycle ergometer. This study had been conducted during May to June 2005, which subjects were 15 males and 15 females in twenties. Experiment was performed with restrictive conditions which regulated ambient temperature, noise, and entrance restriction. Submaximal load test protocols including YMCA Protocol (YP), ${\AA}strand$-Rhyming Protocol (ARP), Relative heart ratio Protocol (RP), and Ramp test Protocol (RP) were compared with maximal load test which used gas mask analyser using Bruce Protocol. All submaximal load tests were highly related with maximal load test (Spearman's correlation coefficient > 0.60) with statistical significancy. The highest correlation coefficient with maximal test was found in RP. Three submaximal test results except RP were significantly different with maximal test results (Wilcoxon rank test). All submaximal tests had high validity. The reason why RP had highest validity might be that it represents Korean physical strength and individual differences better than the others. RP using cycle ergometer would make easy to study for physical capacity evaluation and field workload estimation.

Comparison of Muscle Activity of Both Lower Extremities When a Lower Extremity Cycle Ergometer is Applied During Initial Rehabilitation After Unilateral Total Knee Arthroplasty (편측 무릎인공관절수술 후 초기 재활과정에서 다리 에르고미터 적용 시 양다리 근활성도 비교)

  • Choi, Eunji;Lee, Sangyeol;Seok, Him;Yoon, Sungyoung;Heo, Jaeseok;Lee, Seunghoon
    • PNF and Movement
    • /
    • v.20 no.2
    • /
    • pp.179-187
    • /
    • 2022
  • Purpose: The purpose of this study was to determine the asymmetrical difference between the use of leg muscles on the surgical and non-surgical sides during initial lower extremity ergometer exercise after unilateral knee arthroplasty. Methods: Twelve elderly patients diagnosed with degenerative arthritis of the knee and who underwent unilateral arthroplasty were included in this study. The leg length of each subject was taken into account when setting the application distance of the lower extremity ergometer. The same pedal resistance, strength, and speed were used for all the subjects. The total angle of use of the ergometer (360°) was analyzed by dividing it into an extension section and a flexion section. Using a surface electromyography system, the activities of the muscles of the surgical and non-surgical sides were converted into maximal voluntary isometric contraction (MVIC) and analyzed using the paired t-test. Results: When the activities of the muscles on the surgical and non-surgical sides were compared, it was found that the rectus femoris and biceps femoris had significant differences in the flexion and extension sections (p < .05), and that the tibialis anterior significantly differed in the flexion section (p < .05). There was no significant difference in the extension section of the tibialis anterior muscle, or in the flexion and extension sections of the gastrocnemius (p >.05). Conclusion: The results of this study confirm that the rectus femoris, tibialis anterior, biceps femoris, and gastrocnemius on the surgical side act in an opposite manner to those on the non-surgical side during pedaling in the same section.

Effect of Saddle to Pedal Length in Kayak Ergometer on Rowing Motion and EMG Activation in Elite Kayak Players (엘리트 카약 선수들의 에르고미터를 이용한 로잉 동작 시 안장과 페달의 거리가 로잉 패턴 및 근 활성도에 미치는 영향)

  • Ryue, Jae-Jin;Nam, Ki-Jung;Lee, Chong-Hoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.22 no.1
    • /
    • pp.65-73
    • /
    • 2012
  • The purpose of this study was to identify the saddle to pedal length contributing to successful performance in kayak using a kayak ergometer. Ten male elite kayak players participated in this study. players were tested on the kayak ergometer which was varied saddle to pedal length by the knee flexion angle(90deg; 120deg; 150deg) to measure stroke frequency, paddling amplitude, joint angle, RoM and angular velocity, foot pressure and force, iEMG using the 3D motion system, foot pressure system and EMG wireless system. At a results, rowing at 120deg on knee flexion angle showed higher stroke frequency and paddling amplitude than other knee flexion angles. RoM at upper extremity showed not significant difference between knee flexion angles. But there were significant differences in thorax and pelvis rotation RoM, knee flexion-extension RoM in each condition. In addition, foot pressure, force and iEMG were significantly different in knee flexion angles. Study showed that changed of saddle to pedal length affected rowing performance kinds of stroke frequency, paddling amplitude. The most important thing, increased range of motion in pelvic and thorax has occurred by force that generated foot-bar to seat. Not only that, but it seems to be attributed to a technical adaptation developed to maximum rowing performance.

Effects of functional training on strength, function level, and quality of life of persons in intensive care units

  • Seo, Byul;Shin, Won-Seob
    • Physical Therapy Rehabilitation Science
    • /
    • v.8 no.3
    • /
    • pp.134-140
    • /
    • 2019
  • Objective: The purpose of this study was to investigate the effect of exercise therapy and bedside ergometer exercise on muscle strength, function level, and quality of life of persons in intensive care. Design: Randomized Controlled Trial Methods: Sixteen patients in the ICU were randomly assigned to either the exercise group (n=8) or the bedside cycle ergometer group (n=8). Activities in the ICU exercise group (rolling, sitting at the edge of the bed, transfer from sitting to standing, standing balance training, ambulation) and bedside cycle ergometer group were performed 5 times a week for 30 minutes during the ICU admission period. Medical Research Council (MRC) and Functional Status Scale-Intensive Care Unit (FSS-ICU) parameters were assessed at the time of admission to the ICU, and reevaluation was assessed on the day of ICU discharge. The Short Form-36 (SF-36) was assessed at the time of discharge from the ICU. Results: MRC and FSS-ICU were significantly increased before and after intervention in both the experimental and control groups (p<0.05). There was a significant difference between MRC and FSS-ICU in the comparison of the changes before and after the intervention (p<0.05). SF-36 was compared between groups after intervention and there was a significant difference between the experimental and the control group (p<0.05). Conclusions: Muscle strength and functional levels improved after intervention in both the experimental and control groups. The ICU exercise group was more effective than the bedside cycle ergometer group to improve muscle strength, functional level, and quality of life performance of persons in the ICU.

Effect of interval exercise versus continuous exercise on excess post-exercise oxygen consumption during energy-homogenized exercise on a cycle ergometer

  • Jung, Won-Sang;Hwang, Hyejung;Kim, Jisu;Park, Hun-Young;Lim, Kiwon
    • Korean Journal of Exercise Nutrition
    • /
    • v.23 no.2
    • /
    • pp.45-50
    • /
    • 2019
  • [Purpose] The purpose of this study was to confirm that the difference in excess post-exercise oxygen consumption (EPOC) during exercise of the spending the same calories between the continuous and interval exercise. [Methods] Thirty-four healthy college students who did not regularly exercise volunteered to participate in our study. Continuous exercise was performed on an ergometer for 30 min at 60% of maximal oxygen consumption (VO2 max). Interval exercise was performed on a cycle ergometer at 80% VO2 max for 2 min initially, followed by 40% VO2 max for 1 min, and 80% VO2 max for 3 min. This was repeated six times for a total of 26 min. [Results] The major findings were as follows: (1) energy consumption during exercise was not significantly different between continuous exercise and interval exercise groups; (2) EPOC was higher in interval exercise than in continuous exercise for all dependent variables (i.e., total oxygen consumption, total calories, summation of heart rate); and (3) there were no significant differences in the lipid profile between continuous and interval groups. [Conclusions] Our study confirmed that after equalizing energy expenditure for continuous and interval exercise on a cycle ergometer in subjects in their twenties, interval exercise results in higher EPOC than continuous exercise. These data suggest that interval exercise may be more effective than continuous exercise in reducing body fat, for a given amount of energy expenditure.

Comparison analysis of physiological work capacity for different tasks (작업유형에 따른 생리학적 작업능력의 비교 분석)

  • 박지수;김홍기;최진영
    • Journal of the Ergonomics Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.89-98
    • /
    • 1996
  • The objective of this study was to make comparison of the physical work capacities with different types and methods of tasks. To produce standard work loads, a bicycle ergometer and a treadmill were used for the purpose of two different types of tasks. Maximal oxygen uptake measurement tests are usually performen (1) continuously - with no rest between work load increments, or (2) discontinuously - with the subjects resting several minutes between work periods. Continuous test protocol with two different methods of work load increments, (1) ramp test- with 3 to 5 minutes of work period for each work load, and (2) incremental test - where exercise intensity was increased progressively in 2 minutes interval, were used. Predicted physicala work capacities (PWCs) were compared with the one by Kim(1990), and Lee(1995), and the NIOSH physiological criteria. For ergometer test, the PWC based on the ramp test was 89.65% of the one based on the incremental test. The PWC values were 2553.88 ml/min for the ramp test and 2848.82 ml/min for the incremental test. For treadmill test, the PWC based on the ramp test was 97.54% of the one based on the incremental test. The PWC values were 2786.89 ml/min for the ramp test and 2857.24 ml/min for the incremental test. The PWC obtained with a bicycle ergometer was 91.64% of the one obtained with a treadmill for the ramp test, and 99.71% for the incremental test.

  • PDF

Comparative Aanalysis of Fatigue on Muscle Activities and Physiological Variables during Ergometer Test (에르고미터 운동 시 근활성도와 생리학적 피로도 비교 분석)

  • Yoon, Chang-Jin;Chae, Woen-Sik;Kang, Nyeon-Ju
    • Korean Journal of Applied Biomechanics
    • /
    • v.20 no.3
    • /
    • pp.303-310
    • /
    • 2010
  • The purpose of this study was (a)to compare electromyographic (EMG) activities and physiological variables on the development of fatigue induced by ergometer test, (b)to determine investigate the differences in the stage of fatigue between the electromyographic characteristics and physiological variables. Nine male university students who have no musculoskeletal disorder were recruited as the subjects. The electromyographic characteristics(peak IEMG, average IEMG, median frequency, mean edge frequency) and physiological variables(HR, RPE, blood lactate) were determined for each stage(15, 30, 45, 60 minutes, all out). For each dependent variable, one-way analysis of variance(ANOVA) with repeated measures and correlation analysis were performed to test if significant difference existed(p<.05). The results showed that peak IEMG, average IEMG from low extremity and physiological variables were significantly increased during the all-out stage. EMG parameters in VL, VM show significantly correlation with physiological variables during whole stages. This indicated that IEMG values may be proper parameters to determine muscle fatigue rather than physiological variables.

Comparison of Treadmill and Cycle Ergometer in Male Korean College Students (한국 남자 대학생을 대상으로 시행한 Cardiopulmonary Exercise Test에서 Treadmill과 Cycle Ergometer의 비교 분석)

  • Chang, Yoon-Soo;Park, Jae-Min;Choi, Seung-Won;Ahn, Gang-Hyun;Lee, Jun-Gu;Yang, Dong-Kyu;Kim, Se-Kyu;Chang, Jun;Ahn, Chul-Min;Kim, Seong-Kyu;Lee, Won-Yong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.1
    • /
    • pp.26-34
    • /
    • 1999
  • Background : Generally $VO_2$ max is higher in treadmill exercise than cycle ergometer exercise. According to Hassen and Wasserman, $VO_2$ max with treadmill exercise is higher at ratio of 1.11 than that with cycle ergometer. $VO_2$ max also is influenced by race, sociocultural background, exercise habit In this study, $VO_2$ max and AT were evaluated between Treadmill and cycle exercise in male Korean college students. Method: Study subjects were 44 male college students. We randomized them into 2 groups; 24 students did treadmill exercise at first and 1 week later did cycle ergometer. Another 20 students did in opposite method. They made symptom limited maximal exercise. Author defined maximal exercise as followings: 1) respiratory exchange ratio(RER)> 1.1, 2) plateau>30 sec, 3) heart rate reserve(HRR) <15%, or 4) breathing reserve (BR)<30%. Otherwise their results are excluded as submaximal exercise. Anaerobic threshold(AT) was estimated by V-slope method. Results: $VO_2$ max and AT was $45.1{\pm}6.66m\ell$/kg/min and $26.0{\pm}6.78m\ell$/kg/min in treadmill and $34.9{\pm}5.89m\ell$/kg/min, $19.5{\pm}4.77m\ell$/kg/min in Cycle Ergometer. The measured-$VO_2max$/pred-$VO_2max$ was $98.8{\pm}13.24%$ in treadmill; $84.4{\pm}13.42%$ in cycle ergometer. Comparing $VO_2$ max in treadmill with that obtained by Hassen's method, there were significant differences.(p<0.01). At maximal exercise there were differences in HRR, $O_2$/pulse, BR, $V_E$/MVV, $V_E/VCO_2$ between treadmill and cycle but not in $V_E/VO_2$, Vd/Vt, Ti/Ttot. At AT there were differences in $O_2$/pulse, BR, $V_E$/MVV, Ti/Ttot between treadmill and cycle, otherwise not. Conclusion: According to the result of this study, there are larger gap between treadmill and cycle ergometer in normal Korean adults than foreign data, and it needs further study to obtain reference value of Korea.

  • PDF