• Title/Summary/Keyword: Equivalent length

Search Result 598, Processing Time 0.028 seconds

A Parametric Study on Intermediate Diaphragms of Steel-Box-Girder Bridges (강박스 거더교의 내부 다이아프램에 관한 매개변수 연구)

  • Park, Nam Hoi;Lim, Da Soo;Cho, Sun Kyu;Kang, Young Jong
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.3
    • /
    • pp.231-239
    • /
    • 2003
  • Many box girder bridges have been constructed during the past several decades due to their large bending and torsional rigidities as well as aesthetic considerations. However, box girders have shortcoming in that the cross section distorts under an eccentric loading and warps out of the section plane. Therefore, in order to reduce distortional stresses such as distortional warping and transverse bending normal stresses, diaphragms were generally installed in the box girders. Shapes of the diaphragms in steel-box-girder bridges constructed up to date were solid-plate, frame, and truss types. The objectives of this study using parametric study were to evaluate the appropriate stiffness ratio of intermediate diaphragms and then to propose the effective spacing and numbers of intermediate diaphragms based on the evaluated stiffness ratio. Target bridges for this study were straight continuous span bridges with a single-cell steel box section. The parameters for the parametric study were the shape of box section, the span numbers, the equivalent span length, the stiffness of intermediate diaphragms, and the spacing of intermediate diaphragms. From the results of the parametric study, the effective spacing and numbers as well as the stiffness ratio of the intermediate diaphragms will be presented.

Effects of Intraperitoneal Administration of Bupivacaine on Relief of Pain and Change of Behavior following Ovariohysterectomy in Cats (고양이에서 난소자궁적출술 후 복강 내 Bupivacaine 투여가 통증 감소와 행동 변화에 미치는 영향)

  • Uhm, Mi-Young;Kim, Young-Ki;Lee, Scott S.;Suh, Euy-Hoon;Chang, Hong-Hee;Lee, Hee-Chun;Lee, Hyo-Jong;Yeon, Seong-Chan
    • Journal of Veterinary Clinics
    • /
    • v.26 no.3
    • /
    • pp.205-211
    • /
    • 2009
  • Perioperative pain relief is essential in veterinary practice. However, the cat is one of the most poorly understood species regarding pain control management. Ovariohysterectomy(OHE) produces considerable postoperative pain in cats. Practitioners are often reluctant to administer analgesics due to lack of familiarity with available drugs, concern about side effects, or frustration with the need for record keeping of controlled substances. The purpose of this study was to determine if intraperitoneal administration of bupivacaine can provide relief of pain following OHE in cats. Twelve healthy female cats were randomly divided into two groups. OHE was performed under general inhalation anesthesia. Just prior to complete closure of the linea alba, 6 cats in SAL group received 0.88 ml/kg 0.9% saline, 6 cats in BUP group received 4.4 mg/kg 0.75% bupivacaine diluted to an equivalent volume with saline in the intraperitoneal space. Cats were scored at 0, 1, 2, 4, 8, 12 and 24 hours post-extubation by one observer. Cats were evaluated using a visual analogue scale(VAS) and composite pain scale(CPS) that included physiologic variables. There were no significant differences in body weight, anesthesia time, surgery time, and incision length between the two groups. Cats in the BUP group had significantly(p<0.05) lower VAS-pain scores than cats in the SAL group at 4, 8, 12 hours after surgery. Cats in the BUP group had significantly lower CPS scores than cats in the SAL group at 8, 12 hours after surgery. No adverse side effects were observed. These results support that the intraperitoneal administration of bupivacaine following OHE can be used for the prevention of postoperative pain and pain-induced behavioral changes in cats.

Gradation Curve of Coarse Aggregate by Digital Image Analysis (디지털 이미지 처리 기법을 이용한 굵은골재의 입도분포곡선)

  • Lee, Kwan-Ho;Kim, Young-Jin;Hwang, Tak-Jin;Cho, Jae-Yoon
    • Land and Housing Review
    • /
    • v.2 no.1
    • /
    • pp.69-78
    • /
    • 2011
  • The purpose of this research is particle shape evaluation of aggregate using Digital Image Process(DIP). DIP is very useful to measure the roughness and particle shape of aggregates. Couple of aggregates, like standard sand, two different crushed stones, and two different marine aggregates, have been employed. Shape factors of two different marine aggregates are ranged 0.35 to 0.54. Crushed stone I is 0.74 which is highly flat, but standard sand is elongated shape. Especially, two marine aggregate showed a big difference of width and length which meaned a long shape. There is any significant difference of elongation ratio and flatness for each aggregate with different measuring system, like direct measurement of vernier calipers and DIP method. Shape conversion coefficient and equivalent diameter for changing 2D image to 3D image by the Digital Image Process(DIP) have been suggested and modified particle size distribution curve has been showed. The measured flatness ratios of each aggregate were 0.30, 0.36, 0.47 and 0.83, respectively. Also, the conversion shape coefficients of each aggregate were determinded as 0.77, 0.78, 0.84 and 0.92. The size of aggregate has been modified by multiplying the shape conversion coefficient and the aggregate size from DIP. The modified gradation curve with modified volume and weight of aggregate has been suggested. Within the limited test results, DIP is one of useful to get the particle shape of aggregate with limitation of measuring errors and to apply the particle distribution curve.

Acoustic Performance Evaluation of Noise Barriers Installed Adjacent to Rails and Suggestion of Approximation Formula for the Prediction of Insertion Loss (근접 방음벽의 음향성능평가 및 삽입손실 예측을 위한 근사식의 제안)

  • Yoon, Je Won;Jang, Kang Seok;Cho, Yong Thung
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.5
    • /
    • pp.629-637
    • /
    • 2016
  • In this paper, an investigation was conducted to evaluate the acoustic performance of low height noise barriers installed adjacent to rails; an easy-to-use approximation formula was suggested for the evaluation of insertion loss (IL), instead of using the boundary element method. At first, the acoustic performance of the low height noise barriers was measured in an anechoic chamber using a scaled down model; the overall IL according to the source location was analyzed with the equivalent IL contour line. Using the measurement results obtained from the scaled down model, an approximation formula was suggested for the IL of low height noise barriers having various shapes. Also, the prediction program was validated through a comparison between the actual measurement results in the anechoic chamber and the prediction results. Finally, using the prediction program, an approximation formula for IL was suggested for the low height noise absorption barriers. Considering the frequency characteristics of the noise sources of the train, the absorptive low height noise barriers have a 'ㄱ' type shape, a height of 1.0m, and a length of 0.5m when they are installed on the structure gauge for the train.

The Development of a Multi-Purpose Irradiator and the Characteristic of Dose Distribution (다목적 방사선 조사장치 개발 및 선량분포특성)

  • Lee, Dong-Hoon;Ji, Young-Hoon;Lee, Dong-Han;Kim, Yoon-Jong;Hong, Seung-Hong
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.39 no.6
    • /
    • pp.42-48
    • /
    • 2002
  • The design, construction and performance test of a convenient multi-purpose irradiator is described. A multi-purpose irradiator using Cesium-137 has been developed for studies of low dose radiation effects in biology and for calibration of Thermo Luminescent dosimeter(TLD). During the operation, three rods of radioactive material which are 10cm in length revolve 180 degrees and irradiate biological samples, or TLD, and return to their shielded position, after the programmed time. A programmable Logic Controller(PLC) controls the sequence of operation, interlock, motor rotation and safety system. The rotation speed of biological samples can vary up to 20 RPM. A real time monitoring system was also incorporated to check and control the operation status of the irradiator. The capacity of the irradiation chamber was 4.5 liters. The isodose distribution at arbitrary vertical planes was measured by using film dosimetry. The dose-rate was 0.13 cGy/min in air and 0.11 cGy/min in water equivalent material in the case of Cesium-137. Range of activity was 2 Ci. The homogeneity of dose distribution in the chamber was ${\pm}$7%. The actual radiation level on the surface was within permissible levels. The irradiator had a maximum 0.35 mR/min radiation leakage on its surface.

Miniaturization and Transmission Efficiency Improvement of Resonant Aperture Structure (공진 개구 구조의 소형화 및 투과 효율 개선)

  • Yoo, Jong-Gyeong;Yeo, Junho;Ko, Ji-Whan;Kim, Byung-Mun;Cho, Young-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.6
    • /
    • pp.470-477
    • /
    • 2017
  • As a method of the transmission efficiency improvement of an aperture smaller than the wavelength, we modified the conventional H-shaped resonant aperture to lower the resonance frequency of resonant aperture, and the transmission efficiency of resonant aperture was improved more than the conventional aperture. The maximum transmission cross section(TCS) calculated using the equivalent circuit tends to be almost equal to the maximum TCS from the small resonant aperture modified to improve the transmission efficiency. The transmission characteristics of resonant apertures can be quantified as the TCS, and the transmission efficiency of that can be compared. The modified resonant aperture has a maximum TCS increased by about 2.87 times from $846mm^2$ to $2,431mm^2$ compared to the H-shaped aperture, and the resonant frequency decreased from 5.06 GHz to 2.92 GHz, and the length-to-wavelength ratio of the aperture was reduced from 0.178 to 0.103.

Study on the stress distribution depending on the bone type and implant abutment connection by finite element analysis (지대주 연결 형태와 골질에 따른 저작압이 임프란트 주위골내 응력분포에 미치는 영향)

  • Park, Hyun-Soo;Lim, Sung-Bin;Chung, Chin-Hyung;Hong, Ki-Seok
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.2
    • /
    • pp.531-554
    • /
    • 2006
  • Oral implants must fulfill certain criteria arising from special demands of function, which include biocompatibility, adequate mechanical strength, optimum soft and hard tissue integration, and transmission of functional forces to bone within physiological limits. And one of the critical elements influencing the long-term uncompromise functioning of oral implants is load distribution at the implant- bone interface, Factors that affect the load transfer at the bone-implant interface include the type of loading, material properties of the implant and prosthesis, implant geometry, surface structure, quality and quantity of the surrounding bone, and nature of the bone-implant interface. To understand the biomechanical behavior of dental implants, validation of stress and strain measurements is required. The finite element analysis (FEA) has been applied to the dental implant field to predict stress distribution patterns in the implant-bone interface by comparison of various implant designs. This method offers the advantage of solving complex structural problems by dividing them into smaller and simpler interrelated sections by using mathematical techniques. The purpose of this study was to evaluate the stresses induced around the implants in bone using FEA, A 3D FEA computer software (SOLIDWORKS 2004, DASSO SYSTEM, France) was used for the analysis of clinical simulations. Two types (external and internal) of implants of 4.1 mm diameter, 12.0 mm length were buried in 4 types of bone modeled. Vertical and oblique forces of lOON were applied on the center of the abutment, and the values of von Mises equivalent stress at the implant-bone interface were computed. The results showed that von Mises stresses at the marginal. bone were higher under oblique load than under vertical load, and the stresses were higher at the lingual marginal bone than at the buccal marginal bone under oblique load. Under vertical and oblique load, the stress in type I, II, III bone was found to be the highest at the marginal bone and the lowest at the bone around apical portions of implant. Higher stresses occurred at the top of the crestal region and lower stresses occurred near the tip of the implant with greater thickness of the cortical shell while high stresses surrounded the fixture apex for type N. The stresses in the crestal region were higher in Model 2 than in Model 1, the stresses near the tip of the implant were higher in Model 1 than Model 2, and Model 2 showed more effective stress distribution than Model.

The Bond Characteristics of Deformed Bars in Recycled Coarse Aggregates Concrete (RCAC) (순환골재 콘크리트와 이형철근의 부착 특성)

  • Jeon, Su-Man;Yun, Hyun-Do;Choi, Ki-Sun;You, Young-Chan;Kim, Keung-Hwan
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.2
    • /
    • pp.165-173
    • /
    • 2008
  • One of the most important requirements for reinforced concrete constructions is the bond behavior between concrete and reinforcement. For practical application, it is very important to study bond behavior of reinforcing bars in recycled aggregate concrete (RAC). Thirty six pull-out tests were carried out in order to investigate the bond behaviour between recycled coarse aggregate concrete (RCAC) and deformed bars. RCA replacement ratios (i.e., 0%, 30%, 60% and 100%) and positions of deformed bar (i.e., vertical and horizontal position) were considered as variables in this paper. Each specimen was in the form of a cube, with edges of 150 mm in length and for the pull-out tests, a deformed bar, 13 mm in diameter, was embedded in the center of each specimen. Based on the test results, the bond strength between the RCAC and deformed bars were influenced by both RCA replacement ratios and positions of deformed bars. It was found that under the equivalent mix proportion (i.e., the mix proportions are the same, except for different RCA replacement ratios), the bond strength between the RCAC and the ribbed bar has no obvious relation with the RCA replacement ratio, whereas the positions of deformed bars have a significant effect on the bond behavior between the RCAC and deformed bars. Under the condition of same RCA replacement ratio, the specimen of horizontal reinforcement at upper position (HU type) appear considerably low bond stress.

Design of 1.0V O2 and H2O2 based Potentiostat (전원전압 1.0V 산소 및 과산화수소 기반의 정전압분극장치 설계)

  • Kim, Jea-Duck;XIAOLEI, ZHONG;Choi, Seong-Yeol;Kim, Yeong-Seuk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.2
    • /
    • pp.345-352
    • /
    • 2017
  • In this paper, a unified potentiostat which can measure the current of both $O_2$-based and $H_2O_2$-based blood glucose sensors with low supply voltage of 1.0V has been designed and verified by simulations and measurements. Potentiostat is composed of low-voltage operational transconductance amplifier, cascode current mirrors and mode-selection circuits. It can measure currents of blood glucose chemical reactions occurred by $O_2$ or $H_2O_2$. The body of PMOS input differentional stage of the operational transconductance amplifier is forward-biased to reduce the threshold voltage for low supply voltage operation. Also, cascode current mirror is used to reduce current measurement error generated by channel length modulation effects. The proposed low-voltage potentiostat is designed and simulated using Cadence SPECTRE and fabricated in Magnachip 0.18um CMOS technology with chip size of $110{\mu}m{\times}60{\mu}m$. The measurement results show that consumption current is maximum $46{\mu}A$ at supply voltage of 1.0V. Using the persian potassium($K_3Fe(CN)_6$) equivalent to glucose, the operation of the fabricated potentiostat was confirmed.

Application of Geophysical Survey to the Geological Engineering Model for the Effective Detection in Foundation of Stone Relics (석조문화재 기초지반 파악을 위한 모형지반에서의 탐사기법 적용)

  • Kim, Man-Il;Lee, Chang-Joo;Kim, Jong-Tae;Kim, Ji-Soo;Kim, Sa-Dug;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.18 no.4
    • /
    • pp.537-543
    • /
    • 2008
  • To effectively delineate the foundation of stone relics by GPR and seismic refraction methods, a geological engineering model was constructed with alternating layer of soil and gravel to a depth of 3 m. This study was aimed at mapping the boundaries of model ground structure and interfaces of alternating layer using the various frequency antenna in GPR survey and seismic velocities. Compared to the resolution from the high frequency antenna, the image resolution from the survey using 100 Hz antenna is the lower, but with the deeper image coverage. On the contrast, the deeper structure was not mapped in the higher frequency data due to higher absorption effect, but the shallow layered zone was distinctively resolved. Therefore subsurface images were effectively provided by integrating the data with 100 MHz and 450 MHz antennas for the deep and shallow structures, respectively. Regarding the seismic refraction data, the boundaries of the model and interface of the alternating layers were not successfully mapped due to the limit of the survey length. However, the equivalent contours of low velocity extended deep as considerable velocity contrasts with surrounding ground.