• 제목/요약/키워드: Equivalent fuel consumption

검색결과 34건 처리시간 0.023초

도시생태계 수목의 대기정화 역할 -용인시를 사례료- (Role of Atmospheric Purification by Trees in Urban Ecosystem -in the Case of Yongin-)

  • 조현길;안태원
    • 한국조경학회지
    • /
    • 제29권3호
    • /
    • pp.38-45
    • /
    • 2001
  • This study quantified annual $CO_2$, SO$_2$ and NO$_2$ uptake and annual $O_2$ production by trees in Yongin´s urban ecosystem, and explored values of urban tree plantings in atmospheric purification. Woody plant cover was only 7.7% with planting density of 1. trees/100$m^2$, and the tree-age structure was largely characterized by a young, growing tree population. Annual per capita pollutant emissions from fossil fuel consumption were 7.3t/yr for $CO_2$, 7.6kg/yr for SO$_2$, and 26.6kg/yr for NO$_{x}$. Carbon dioxide storage per unit urban area by trees was 13.1t/ha and the economic value for $CO_2$ storage was ₩6.6millions/ha. Annual atmospheric purification was 2.0t/ha/yr for $CO_2$ uptake, 2.0kg/ha/yr for SO$_2$ uptake, 4.0kg/ha/yr for NO$_2$ uptake and 1.5t/ha/yr for $O_2$ production, and the annual economic value for the atmospheric purification was ₩1.5millions/ha/yr. Urbantrees stored an amount of $CO_2$ equivalent to about 3.1% of the total annual $CO_2$ emissions, and annually offset total $CO_2$ emissions by 0.5%. Annual SO$_2$ and NO$_2$ uptake by trees equaled 0.5% of total SO$_2$ emissions and 0.3% of total NO$_{x}$ emissions, respectively. Urban trees also played an important role through producing annually 9.2 of the $O_2$ requirement for Yongin´s total population, despite relatively poor tree plantings. Future active plantings and greenspace enlargement in the study city could enhance the role of atmospheric purification by urban trees. The results from this study are expected to be useful in emphasizing environment benefits of urban trees, and in urging the continuous necessity for tree planting and management budget.get.

  • PDF

삼중수소의 환경방출에 따른 주민선량 규제모델의 비교 (Comparison of the Regulatory Models Assessing Off-Site Radiological Dose due to the Routine Releases of Tritium)

  • 황원태;김은한;한문희;최용호;이한수;이창우
    • 방사성폐기물학회지
    • /
    • 제3권2호
    • /
    • pp.125-133
    • /
    • 2005
  • 삼중수소의 환경방출에 따른 주민선량의 규제이행을 위해 개발된 NEWTRIT모델, AIRDOS-EPA 모델, NRC 모델의 평가 방법을 고찰하고, 활용 가능한 국내 특성자료를 사용하여 예측결과를 비교하였다. 이들 모델 중에서 가장 최근에 개발된 NEWTRIT 모델만이 tritiated water (HTO) 방출에 따른 organically bounded tritium (OBT)의 영향을 고려한다. 평가결과 삼중수소의 환경방출로 인해 모든 가능한 경로로부터 받게 되는 총 피폭선량은 AIRDOS-EPA 모델의 예측결과가 NEWTRIT모델과 NRC모델에 비해 각각 1.03배, 2.46배 높은 결과를 나타냈다. 이러한 결과로부터 NRC모델로 예측되는 피폭선량이 실제 주변주민이 받을 수 있는 피폭선량을 과소평가할수 있다고 이해해서는 안될 것이다. 왜냐하면 삼중수소의 환경내 거동에 대한 불확실성은 매우 크기 때문에 규제이행을 위한 수학적 모델과 관련 변수 값은 극히 보수적 가정에 근거하기 때문이다. NEWIRIT 모델로 예측된 식품섭취에 의한 피폭선량에서 우리나라의 주식인 곡류의 상대적으로 많은 섭취로 OBT는 HTO와 거의 대둥한 수준의 영향을 나타내었다. 삼중수소의 환경방출에 따른 총 피폭선량에서 NRETRIT 모델은 AIRDOS-EPA 모델과 유사한 예측결과를 나타내지만, NEWTRIT 모델은 식품섭취에 따른 OBT의 영향을 고려함으로써 환경으로 방출된 HTO 거동의 현상적 이해 둥에 있어서 보다 의미가 있다고 판단된다.

  • PDF

온풍난방기의 배기열을 이용한 지중 난방용 온수공급시스템의 열회수특성 (Heat Recovery Characteristics of the Hot Water Supply System with Exhaust Heat Recovery Unit Attached to the Hot Air Heater for Plant Bed Heating in the Greenhouse)

  • 김영중;유영선;장진택;강금춘;이건중;신정웅
    • Journal of Biosystems Engineering
    • /
    • 제25권3호
    • /
    • pp.221-226
    • /
    • 2000
  • Hot air heater with light oil burner is the most common heater for greenhouse heating in the winter season in Korea. However, since the thermal efficiency of the heater is about 80∼85%, considerable unused heat amount in the form of exhaust gas heat discharges to atmosphere. In order to capture this exhaust heat a heat recovery system for plant bed heating in the greenhouse was built and tested in the hot air heating system of greenhouse. The heat recovery system is made for plant bed or soil heating in the greenhouse. The system consisted of a heat exchanger made of copper pipes, ${\Phi}12.7{\times}0.7t$ located in the rectangular column of $330{\times}330{\times}900mm$, a water circulation pump, circulation plastic pipe and a water tank. The total heat exchanger area is 1.5$m^2$, calculated considering the heat exchange amount between flue gas and water circulated in the copper pipes. The system was attached to the exhaust gas path. The heat recovery system was designed as to even recapture the latent heat of flue gas when exposing to low temperature water in the heat exchanger. According to the performance test it could recover 45,200 to 51,000kJ/hr depending on the water circulation rates of 330 to $690\ell$/hr from the waste heat discharged. The exhaust gas temperature left the heat exchanger dropped to $100^{\circ}C$ from $270^{\circ}C$ by the heat exchange between the water and the flue gas, while water gained the difference and temperature increased to $38^{\circ}C$ from $21^{\circ}C$ at the water flow rate of $690\ell$/hr. By the feasibility test conducted in the greenhouse, the system did not encounter any difficulty in operations. And, the system could recover 220,235kJ of exhaust gas heat in a day, which is equivalent of 34% of the fuel consumption by the water boiler for plant bed heating of 0.2ha in the greenhouse.

  • PDF

남극 장보고기지 건설 시 온실가스 배출량 산정 (Estimation of Greenhouse Gas Emissions During the Construction of Jangbogo Antarctic Research Station)

  • 주진철;윤정임;이승은;김유민;채창우;김영석
    • 대한환경공학회지
    • /
    • 제34권4호
    • /
    • pp.270-279
    • /
    • 2012
  • 본 연구에서는 남극 장보고기지 건설 시 발생하는 온실가스 배출량을 자재생산단계와 시공단계로 구분하여 산정하였다. 또한, 시공단계의 배출원은 각각 해양수송과 내륙수송, 건설장비 사용, 건설캠프 운영으로 분류하여 온실가스 배출량을 구체적으로 산정하였다. 전과정평가 개념을 도입해 남극 장보고기지 건설에 투입되는 자재생산을 통해 배출되는 온실가스 배출량은 기지 건설에 따른 전체 온실가스 배출량의 23.8%에 해당하는 8,933 ton (as $CO_{2eq}$)으로 산정되었으며, 향후 남극 신규기지의 건설 시 자재생산을 통한 온실가스 배출이 반드시 고려해야 할 대상인 것으로 판단되었다. 남극 장보고기지 시공단계(총 2단계)에서의 온실가스 배출량은 1단계에 비해서 2단계에 비교적 많이 배출되었으며, 이는 2단계 때 수송화물선이 부산까지 회항하여 정박하므로 연료사용량이 증가하기 때문인 것으로 사료된다. 또한, 시공단계의 온실가스 배출원 가운데 해양수송이 내륙수송, 건설장비 사용 및 건설캠프 운영에 비해 다량의 온실가스를 배출하는 것으로 판명되었다. 남극 장보고기지 건설에 따른 자재생산단계와 시공단계를 통합한 전체 온실가스 배출량은 총 34,486 ton (as $CO_{2eq}$)으로 기존 남극기지 포괄적 환경영향평가(CEE)상에 제시된 온실가스 총배출량과 비교 시 다량의 온실가스가 배출되는 것으로 나타났다. 이는 기존 CEE상에 제시된 온실가스 배출량 산정 시 건설에 투입되는 자재생산을 통해 발생하는 온실가스 배출량 산정이 고려되지 않고, 단순히 자재수송 및 시공단계만을 고려하여 온실가스 배출량을 개략적으로 산정하였기 때문으로 판단된다.