• 제목/요약/키워드: Equivalent damping

검색결과 389건 처리시간 0.027초

Study on seismic performance of shaking table model of full light-weight concrete utility tunnel

  • Yanmin Yang;Qi Yuan;Yongqing Li;Jingyu Li;Yuan Gao;Yuzhe Zou
    • Computers and Concrete
    • /
    • 제32권1호
    • /
    • pp.15-26
    • /
    • 2023
  • In order to study the anti-seismic performance of full light-weight concrete utility tunnel, EL Centro seismic waves were input, and the seismic simulation shaking table test was carried out on the four utility tunnel models. The dynamic characteristics and acceleration response of the system consisting of the utility tunnel structure and the soil, and the interlayer displacement response of the structure were analyzed. The influence law of different construction methods, haunch heights and concrete types on the dynamic response of the utility tunnel structure was studied. And the experimental results were compared with the finite element calculation results. The results indicated that with the increase of seismic wave intensity, the natural frequency of the utility tunnel structure system decreased and the damping ratio increased. The assembling composite construction method could be equivalent to replace the integral cast-in-place construction method. The haunch height of the assembling composite full light-weight concrete utility tunnel was increased from 30 mm to 50 mm to enhance the anti-seismic performance during large earthquakes. The anti-seismic performance of the full light-weight concrete utility tunnel was better than that of the ordinary concrete utility tunnel. The peak acceleration of the structure was reduced by 21.8% and the interlayer displacement was reduced by 45.8% by using full light-weight concrete. The finite element simulation results were in good agreement with the experimental results, which could provide reference for practical engineering design and application.

Effect of relative stiffness on seismic response of subway station buried in layered soft soil foundation

  • Min-Zhe Xu;Zhen-Dong Cui;Li Yuan
    • Geomechanics and Engineering
    • /
    • 제36권2호
    • /
    • pp.167-181
    • /
    • 2024
  • The soil-structure relative stiffness is a key factor affecting the seismic response of underground structures. It is of great significance to study the soil-structure relative stiffness for the soil-structure interaction and the seismic disaster reduction of subway stations. In this paper, the dynamic shear modulus ratio and damping ratio of an inhomogeneous soft soil site under different buried depths which were obtained by a one-dimensional equivalent linearization site response analysis were used as the input parameters in a 2D finite element model. A visco-elasto-plastic constitutive model based on the Mohr-Coulomb shear failure criterion combined with stiffness degradation was used to describe the plastic behavior of soil. The damage plasticity model was used to simulate the plastic behavior of concrete. The horizontal and vertical relative stiffness ratios of soil and structure were defined to study the influence of relative stiffness on the seismic response of subway stations in inhomogeneous soft soil. It is found that the compression damage to the middle columns of a subway station with a higher relative stiffness ratio is more serious while the tensile damage is slighter under the same earthquake motion. The relative stiffness has a significant influence on ground surface deformation, ground acceleration, and station structure deformation. However, the effect of the relative stiffness on the deformation of the bottom slab of the subway station is small. The research results can provide a reference for seismic fortification of subway stations in the soft soil area.

Nonlinearity effect on the dynamic behavior of the clayey basin edge

  • Hadi Khanbabazadeh
    • Geomechanics and Engineering
    • /
    • 제36권4호
    • /
    • pp.367-380
    • /
    • 2024
  • Investigations has shown that the correct estimation of the effective amplification period is as important as the amplification value itself. It gets more important in 2D basins. This study presents a quantitative coefficient for consideration of the nonlinearity effect in terms of amplification value and the shift in its period which is missing or ineffectively considered in the previous studies. To attain this goal, by the application of a time domain fully nonlinear method, the deviation of the more common equivalent linear results from the basin nonlinear behavior under strong ground motions is investigated quantitatively. Also, despite the increase in the damping ratio, the possibility of the increase in the amplification due to the increase in motion strength is shown. To make the results useful in engineering practice, by introducing nonlinearity ratio, the effect of the nonlinearity is quantitatively estimated for two soft and stiff clayey basins with three different depths under a set of motions scaled to two target spectrum. Results show that at the 100 m depth soft clayey basin, while the nonlinearity ratio shows a 35% deviation at the basin edge part under DD1 motion level, its effect moves to the central part with 20% effect under DD3 motion level. By the increase in depth to 150 m, the results show a decrease in the overall effect of the nonlinear behavior for both clay types. At this depth, the nonlinearity ratio gives a 30% and 17% difference on a limited distance from outcrop at the soft clayey basin under DD1 and DD3 motion levels, respectively. At the 30 m depth basins, the nonlinearity ratio shows up to 25% difference for different cases. The presented ratio would be introduced as nonlinearity coefficients for consideration of the nonlinearity effects in the codes. The presented quantitative margins will help the designer to have a better understanding of the amplification period change because of nonlinearity over 2D basin surface.

Full-scale 저경도 납면진받침의 온도의존성에 대한 실험적 연구 (Experimental Study on the Temperature Dependency of Full Scale Low Hardness Lead Rubber Bearing)

  • 박진영;장광석;이홍표;이영학;김희철
    • 한국전산구조공학회논문집
    • /
    • 제25권6호
    • /
    • pp.533-540
    • /
    • 2012
  • 납코어가 삽입된 적층고무받침은 주요 재료가 온도에 대한 의존성을 보유하고 있으므로 온도 환경이 장치의 성능에 미치는 영향이 적지 않다. 따라서, 본 논문에서는 대표적인 면진장치인 납면진받침에 대하여 실규모 장치를 제작하고 온도변화에 따른 강성 및 감쇠 특성변화에 대하여 실험을 통하여 분석하고 평가하였다. 실물 크기의 납면진받침을 사용하여 $-10^{\circ}C$, $0^{\circ}C$, $10^{\circ}C$, $20^{\circ}C$, $30^{\circ}C$, $40^{\circ}C$의 온도 조건에 대하여 ISO22762:2010에서 제시하고 있는 특성시험법을 적용하여 수직강성 및 수평특성에 대하여 의존성 경향을 파악하였다. 또한, 면진받침 설계 시 주요한 평가지표로 사용되는 2차강성 및 특성강도에 대하여 해외 제조사에서 제시하고 있는 온도보정식과 시험결과를 비교하였으며 수직강성에 대한 온도의존 경향을 파악하였다.

신뢰도 기반 활하중모델에 의한 강합성 사장교의 충격계수 평가 (Evaluation of Impact Factor in Composite Cable-Stayed Bridges under Reliability-based Live Load Model)

  • 박재봉;박용명;김동현;이종한
    • 한국강구조학회 논문집
    • /
    • 제25권4호
    • /
    • pp.335-346
    • /
    • 2013
  • AASHTO LRFD 및 도로교한계상태설계기준에서는 신뢰도 기반 활하중 모델로부터 결정된 트럭하중과 차로하중을 동시에 재하하도록 하고 있으며, 트럭하중은 충격계수를 고려하되 차로하중은 충격계수를 적용하지 않도록 규정하고 있다. 본 연구에서는 중앙경간 230m, 400m 및 540m의 멀티케이블 강합성 사장교를 대상으로 트럭하중과 차로하중이 동시에 주행하는 경우에 대해 차량-교량 상호작용 해석을 수행하고 케이블과 보강거더의 충격계수를 평가하였다. 트럭하중은 6-자유도의 차량 모델을 사용하였으며, 차로하중은 일련의 1축 차량이 연행해서 주행하는 것으로 모사하였다. 교량의 감쇠비가 충격계수에 미치는 영향을 평가하였으며, 충격에 영향을 미치는 주요 인자인 노면조도와 주행속도를 해석변수로 고려하였다. 노면조도는 ISO 8608 규정에 근거하여 랜덤 생성하였으며, 차량-교량 상호작용해석 시 노면조도는 트럭하중에만 적용하였다. 한편, 사장교의 충격계수 평가를 위해 실무에서 사용되고 있는 영향선 기법에 의한 충격계수를 동적 상호작용 해석에 의한 결과와 비교하였다.

축방향철근비 2.017%인 중공 원형 RC 기둥의 내진성능과 휨 초과강도 (Seismic Performance and Flexural Over-strength of Hollow Circular RC Column with Longitudinal Steel Ratio 2.017%)

  • 고성현
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제21권1호
    • /
    • pp.1-8
    • /
    • 2017
  • 형상비(M/VD, shear span-depth ratio)가 4.5인 축소모형의 원형기둥 실험체 3개를 제작하였다. 철근콘크리트 기둥 실험체의 단면은 원형이고 중공단면으로 제작되었다. 철근콘크리트 기둥 실험체의 단면 지름은 400 mm, 중공 지름은 200 mm이다. 일정한 축력 하에서 반복하중을 가력하는 준정적 실험을 수행하였다. 실험체의 주요변수는 횡방향철근비이다. 모든 실험체의 횡방향 나선철근 체적비는 소성힌지 구간에서 0.302~0.604%의 값을 갖는다. 이 값은 도로교설계기준에서 요구하는 최소 심부구속철근 요구량의 45.9~91.8%에 해당하며, 이는 내진 설계가 되지 않은 기존 교각이나 내진설계개념으로 설계되는 교각을 나타낸다. 본 연구의 최종목적은 실험적 기초자료의 제공과 함께 성능단계별 균열거동, 하중-변위 이력곡선, 에너지 소산 능력, 등가점성감쇠비, 잔류변형, 유효강성 등 내진성능의 정량적 수치와 경향을 제공하기 위한 것이다. 본 논문에서는 실험결과를 통해 분석된 실험변수에 따른 실험결과들을 공칭강도, 비선형 모멘트-곡률 해석 결과, AASHTO LRFD 및 도로교설계기준(한계상태설계법)과 같은 기준들과 비교하였다.

등가감쇠비를 이용한 역량스펙트럼법에 의한 곡선교의 비탄성지진응답 평가 (Evaluation of the Inelastic Seismic Response of Curved Bridges by Capacity Spectrum Method using Equivalent Damping)

  • 조양희;조성국;마정석
    • 한국지진공학회논문집
    • /
    • 제13권1호
    • /
    • pp.17-26
    • /
    • 2009
  • 최근 들어 구조물의 내진성능평가법으로서 간편법인 역량스펙트럼법이 건축물을 비롯한 교량분야에도 활용되고 있다. 현재까지의 연구는 대부분 대칭성을 갖는 정형화된 형상의 교량을 대상으로 하는 연구가 진행되어 왔다. 이 논문에서는 역량스펙트럼법을 비정형 곡선교에 적용시켰을 때의 실용성을 검토하였다. 이를 위해 3경간 연속 곡선교의 비탄성 내진성능을 역량스펙트럼법과 시간이력해석법으로 평가하였다. 곡선교의 응답은 단순 3경간 대칭형 직선교의 응답과 비교하고, 곡선교의 원호각의 정도에 따른 비탄성변위응답의 변화를 분석하였다. 역량스펙트럼법에 의한 평가결과는 비선형 시간이력해석법에 의한 결과와 비교하였다. 입력운동으로 사용한 지반 운동은 실제 기록 지진 중에서 선별된 El Centro지진과 Kobe지진이다. 해석결과, 역량스펙트럼법이 시간이력해석방법에 비하여 대체적으로 변위응답을 크게 산출하고 있는 것으로 확인되었다. 역량스펙트럼법에 의한 해석결과로 얻어진 직선교에 대한 변위 응답 값은 시간이력해석결과와 대체적으로 일치하고 있다. 하지만 곡선교의 원호각이 커질수록 교각의 비탄성 변위는 직선교의 비탄성 변위와 비교하였을 때 그 차이가 증가되는 것으로 확인되었다.

형상기억합금의 휨거동 및 교량변위제어장치적용 연구 (Bending behavior of shape memory alloy bar and its application of seismic restrainers for bridges)

  • 최은수;박주남;김학수;이도형
    • 한국지진공학회논문집
    • /
    • 제11권5호
    • /
    • pp.23-32
    • /
    • 2007
  • 본 논문은 형상기억합금 바의 휨 거동 특성 파악하기 위하여 여러 가지의 휨 거동 실험을 수행하였으며, 형상기억합금 바의 휨 거동분석을 통하여 지진 시에 적용 가능성을 규명하는데 목적이 있다. 이를 위해 단순 휨 및 이중 휨 실험을 재하속도 및 최대변위를 변수로 수행하였다. 힘-변위 곡선에서 추정한 재하 및 제하 시의 강성이 추정되었으며, 등가의 감쇠비도 각 실험결과에서 추정되었다. 단순 휨에서 형상기억합금 바는 32 mm 변위 이후에 강성증가현상을 나타냈으며, 이것은 SIM(Stress-Induced-Martensite) 현상에 의해서 발생하는 것으로 추정된다. 재하속도의 증가는 형상기억합금 휨 강성 증가에 영향을 주지 않는 것으로 나타났다. 이중 휨 거동에서 형상기억합금 바는 단순 휨에 비해 강성이 약 5배정도 크게 나타났으며, 감쇠비는 유사하게 나타났다. 휨 거동의 형상기억합금 바를 지진 변위 제어장치로 사용하여 3경간 단순지지 교량에 적용하여 지진해석을 수행하였다. 이러한 지진변위 제어장치는 매우 효과적인 것으로 나타났으며, 실용적인 것으로 판단된다. 본 논문의 의미는 형상기억합금 바의 휨 거동에 대한 기초 지식을 제공하는데 있다.

기초형식에 따른 LNG 저장탱크의 지반-구조물 상호작용을 고려한 수직방향 지진응답 분석 (Evaluation of Soil-Structure Interaction Responses of LNG Storage Tank Subjected to Vertical Seismic Excitation Depending on Foundation Type)

  • 손일민;김재민
    • 한국전산구조공학회논문집
    • /
    • 제32권6호
    • /
    • pp.367-374
    • /
    • 2019
  • 논문에서는 수직방향 지진입력에 의한 지반-구조물 상호작용 효과가 기초 종류에 따라 LNG 저장탱크의 지진응답에 미치는 효과를 분석하였다. 이를 위하여 직경 71m인 LNG 탱크와 기반암 위 점토지반의 깊이가 30m인 지반조건을 고려하였다. 그리고 기초형식으로 네 가지(얕은 기초, 말뚝지지 전면기초, 말뚝기초(지표면 접촉식, 부유식)를 고려하였다. 지반의 비선형성은 자유장 지반에 대하여 등가선형화기법으로 고려되었다. 또한, 말뚝기초의 시공과정에서 발생하는 동다짐 효과에 대해서도 분석하였다. SSI 해석을 위하여 진동수영역 해석프로그램인 KIESSI-3D를 이용하였다. 지반-구조물 상호작용 해석을 통해 LNG 저장탱크의 외조 벽체 쉘의 응력을 구하였다. 해석결과로부터 다음과 같은 결론을 얻을 수 있었다: (1) 얕은 기초에서 외조탱크의 수직응력은 SSI 효과로 인하여 고정기초응답 보다 작았다. (2) 말뚝으로 지지된 기초에서 말뚝으로 인해 기초의 수직강성이 커지고 방사감쇠가 작아질 수 있기 때문에 SSI 응답이 고정기초응답 보다 커질 수 있다. (3) 동다짐 효과는 수직지진에 의한 LNG 저장탱크의 응답에 미치는 영향이 매우 작았다.