• 제목/요약/키워드: Equivalent Structure

검색결과 1,593건 처리시간 0.024초

지진특성에 따른 MR감쇠기가 설치된 단자유도 구조물의 등가감쇠비 (Equivalent Damping Ratio Based on Earthquake Characteristics of a SDOF Structure with an MR Damper)

  • 문병욱;박지훈;이성경;민경원
    • 한국소음진동공학회논문집
    • /
    • 제18권1호
    • /
    • pp.87-93
    • /
    • 2008
  • Seismic control performance of MR dampers, which have severe nonlinearity, varies with respect to the dynamic characteristics of an earthquake such as magnitude, frequency and duration. In this study, the effects of excitation characteristics on the equivalent linear system of a building structure with the MR damper are investigated through numerical analysis for artificial ground motions generated from different response spectrums. The equivalent damping ratio of the structure with the MR damper is calculated using Newmark and Hall's equations for ground motion amplification factors. It is found that the equivalent damping ratio of the structure with the MR damper is dependent on the ratio of the maximum friction force of the MR damper over excitation magnitude. Frequency contents of the earthquake ground motion affects the equivalent damping ratio of long-period structures considerably. Also, additional damping effect caused by interaction between the viscousity and friction of the MR damper is observed. Finally. response reduction factors for equivalent linear systems are proposed in order to improve accuracy in the prediction of the actual nonlinear response.

CPW 구조를 이용한 metamaterial 전송선로 특성에 관한 연구 (A study of metamaterial transmission line characteristics using CPW structure)

  • 김진수;황희용
    • 산업기술연구
    • /
    • 제28권B호
    • /
    • pp.251-255
    • /
    • 2008
  • Metamaterial are artificial structures that can be designed to exhibit specific electromagnetic properties not commonly found in nature. Metamaterial transmission lines are usually fabricated with a microstrip structure and it's equivalent circuit is composed of two series capacitances and a shunt inductance. However microstrip structure need a via hall for realizing a shunt inductance. To eliminate via hall, we proposed a CRLH transmission line using a CPW structure, and obtained equivalent circuit values, line parameters.

  • PDF

Equivalent damping of a structure with vibration control devices subjected to wind loads

  • Hwang, Jae-Seung;Kim, Jinkoo;Lee, Sang-Hyun;Min, Kyung-Won
    • Wind and Structures
    • /
    • 제6권4호
    • /
    • pp.249-262
    • /
    • 2003
  • The purpose of this study is to propose a procedure for evaluating quantitatively the increase of the equivalent damping ratio of a structure with passive/active vibration control systems subjected to a stationary wind load. A Lyapunov function governing the response of a structure and its differential equation are formulated first. Then the state-space equation of the structure coupled with the secondary damping system is solved. The results are substituted into the differential equation of the Lyapunov function and its derivative. The equivalent damping ratios are obtained from the Lyapunov function of the combined system and its derivative, and are used to assess the control effect of various damping devices quantitatively. The accuracy of the proposed procedure is confirmed by applying it to a structure with nonlinear as well as linear passive/active control systems.

An equivalent linear SDOF system for prediction of nonlinear displacement demands of non-ductile reinforced concrete buildings with shear walls

  • Saman Yaghmaei-Sabegh;Shabnam Neekmanesh;Nelson Lam;Anita Amirsardari;Nasser Taghizadieh
    • Structural Engineering and Mechanics
    • /
    • 제85권5호
    • /
    • pp.655-664
    • /
    • 2023
  • Reinforced concrete (RC) shear wall structures are one of the most widely used structural systems to resist seismic loading all around the world. Although there have been several efforts to provide conceptually simple procedures to reasonably assess the seismic demands of structures over recent decades, it seems that lesser effort has been put on a number of structural forms such as RC shear wall structures. Therefore, this study aims to represent a simple linear response spectrum-based method which can acceptably predict the nonlinear displacements of a non-ductile RC shear wall structure subjected to an individual ground motion record. An effective period and an equivalent damping ratio are introduced as the dynamic characteristics of an equivalent linear SDOF system relevant to the main structure. By applying the fundamental mode participation factor of the original MDOF structure to the linear spectral response of the equivalent SDOF system, an acceptable estimation of the nonlinear displacement response is obtained. Subsequently, the accuracy of the proposed method is evaluated by comparison with another approximate method which is based on linear response spectrum. Results show that the proposed method has better estimations for maximum nonlinear responses and is more utilizable and applicable than the other one.

Seismic equivalent linear response of a structure by considering soil-structure interaction: Analytical and numerical analysis

  • Maroua Lagaguine;Badreddine Sbartai
    • Structural Engineering and Mechanics
    • /
    • 제87권2호
    • /
    • pp.173-189
    • /
    • 2023
  • For a given structural geometry, the stiffness and damping parameters of the soil and the dynamic response of the structure may change in the face of an equivalent linear soil behavior caused by a strong earthquake. Therefore, the influence of equivalent linear soil behavior on the impedance functions form and the seismic response of the soil-structure system has been investigated. Through the substructure method, the seismic response of the selected structure was obtained by an analytical formulation based on the dynamic equilibrium of the soil-structure system modeled by an analog model with three degrees of freedom. Also, the dynamic response of the soil-structure system for a nonlinear soil behavior and for the two types of impedance function forms was also analyzed by 2D finite element modeling using ABAQUS software. The numerical results were compared with those of the analytical solution. After the investigation, the effect of soil nonlinearity clearly showed the critical role of soil stiffness loss under strong shaking, which is more complex than the linear elastic soil behavior, where the energy dissipation depends on the seismic motion amplitude and its frequency, the impedance function types, the shear modulus reduction and the damping increase. Excellent agreement between finite element analysis and analytical results has been obtained due to the reasonable representation of the model.

유한한 마이크로스트립 안테나구조에서 CG-FFT 방법을 이용한 복사 해석 (Radiation Analysis of a Finite Microstrip Antenna Structure Using the CG-FFT Method : Volume Formulation)

  • 손창우;이철훈김종규조영기
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 추계종합학술대회 논문집
    • /
    • pp.343-346
    • /
    • 1998
  • In this paper a radiation problem for a finite microstrip antenna structure is analyzed. For the analysis of finite structures we utilize the equivalent volume current. Intergral equation for the unknown equivalent volume current induced on a finite microstrip structure is derived and solved by the use of conjugate gradient-fast fourier. transform (CG-FFT) method. Some numerical examples are radiation patterns derived by the equivalent volume current solved by the conjugate gradient-fast fourier transform.

  • PDF

유연도 영향계수법을 이용한 접촉결합부가 있는 복합구조물의 동적 해석 (Structural Dynamics Analysis of a Clamp Jointed Complex Ream by Using the Flexibility Influence Coefficient Method)

  • 조재혁;김현욱;최영휴
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.528-533
    • /
    • 1995
  • An analyical method is proposed to construct a clamp jointed structure as an equivalent stiffness matrix element in the finite element modal analysis of a complex beam structure. Static structural analysis was first made for the detail finite element model of the clamp joint. Utilizing the results of this analysis, the equivalent stiffness matrix element was buildup by using the flexibility influence coefficient method and Guyan condensation. The proposed method was applied to finite element modal analysis of a clamp jointed cantilever beam. And the finite element analysis results were compared to those experimental modal analysis. Comparison shows doog agreement each other Furthermore the effects of normal contact(or clamping) load on the equivalent stiffness matrix was also examined. The equivalent stiffness matrix showed little change in spite of the remakable increase in the contact load on the clamp joint.

  • PDF

결합부 등가빔을 이용한 저진동 차체의 모델링 및 해석기법 (Modeling and Vibration Analysis of Vehicle Structures Using Equivalent Beam Stiffness for Joints)

  • 임홍재;김윤영;이상범;송명의
    • 소음진동
    • /
    • 제5권4호
    • /
    • pp.537-542
    • /
    • 1995
  • In this paper the method of modeling and optimization for the joint of the vehicle structure is proposed. First it is described that the method of substituting equivalent beam elements to spring elements for the joint. The stiffnesses of the spring elementsare calculated using the section properties of equivalent beam elements. To get required dynamic characteristics section properties of equivalent beam element are set to design variables and optimized. The study shows that joint stiffnesses can be effectively determined in designing vehicle structure.

  • PDF

고속전철용 주름판넬구조의 등가평판모델 및 방사소음 (Equivalent Plate Model and Acoustic Power Radiation of the Corrugated Panel Structures for High Speed Train)

  • 장준호;이상윤;홍성철;이우식
    • 한국철도학회논문집
    • /
    • 제2권3호
    • /
    • pp.26-35
    • /
    • 1999
  • The acoustic power reduction method can be used to design a quiet structure. To calculate the acoustic power radiated from a vibrating structure, the dynamic responses have to be determined. It is not easy to analyse the structure composed of the corrugated panels because of the structural complexity and the long analysing time. To make up for these defects, the equivalent orthotropic panel is presented. Also the acoustic power prediction method of the vibrating structures is proposed. As examples, the equivalent material properties of the corrugated plates are obtained and the acoustic powers of the floor structure are calculated at several frequency regions for the Korean High Speed Train.

  • PDF

Dynamic properties of a building with viscous dampers in non-proportional arrangement

  • Suarez, Luis E.;Gaviria, Carlos A.
    • Structural Engineering and Mechanics
    • /
    • 제55권6호
    • /
    • pp.1241-1260
    • /
    • 2015
  • Any rational approach to define the configuration and size of viscous fluid dampers in a structure should be based on the dynamic properties of the system with the dampers. In this paper we propose an alternative representation of the complex eigenvalues of multi degree of freedom systems with dampers to calculate new equivalent natural frequencies. Analytical expressions for the dynamic properties of a two-story building model with a linear viscous damper in the first floor (i.e. with a non-proportional damping matrix) are derived. The formulas permit to obtain the equivalent damping ratios and equivalent natural frequencies for all the modes as a function of the mass, stiffness and damping coefficient for underdamped and overdamped systems. It is shown that the commonly used formula to define the equivalent natural frequency is not applicable for this type of system and for others where the damping matrix is not proportional to the mass matrix, stiffness matrix or both. Moreover, the new expressions for the equivalent natural frequencies expose a novel phenomenon; the use of viscous fluid dampers can modify the vibration frequencies of the structure. The significance of the new equivalent natural frequencies is expounded by means of a simulated free vibration test. The proposed approach may offer a new perspective to study the effect of viscous dampers on the dynamic properties of a structure.