• Title/Summary/Keyword: Equivalent Source

Search Result 576, Processing Time 0.026 seconds

An Application of Equivalent Heat Source for Thermal Analysis of Pavement Process (포장시 열영향 해석을 위한 등가열원의 적용성)

  • Lee, Wan-Hoon;Yoo, Byoung-Chan;Chung, Heung-Jin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.3A
    • /
    • pp.391-399
    • /
    • 2008
  • Because of relatively high temperature, over $240^{\circ}C$, of asphalt for steel deck bridge during pavement procedure, the temperature of deck could rise over $100^{\circ}C$ and undesirable excessive displacement and thermal stress could occur. In this study, in order to estimate the thermal effect of pavement process and to find the optimal pavement process, a new thermal analysis technique with Equivalent Heat Source (EHS) is proposed and its applicability to the practical pavement of steel bridge is studied. EHS is developed to simulate the high temperature pavement materials and its thermal effect such as conduction and convection which cannot be explain easily in general structural analysis program for bridge design. To verify the applicability of new analysis technique with EHS, thermal analyses of steel deck bridge with uplift and curved bridge with various pavement procedures are presented.

Thermal Analysis of Water Cooled ISG Based on a Thermal Equivalent Circuit Network

  • Kim, Kyu-Seob;Lee, Byeong-Hwa;Jung, Jae-Woo;Hong, Jung-Pyo
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.893-898
    • /
    • 2014
  • Recently, the interior permanent synchronous motor (IPMSM) has been applied to an integrated starter and generator (ISG) for hybrid electric vehicles. In the design of such a motor, thermal analysis is necessary to maximize the power density because the loss is proportional to the power of a motor. Therefore, a cooling device as a heat sink is required internally. Generally, a cooling system designed with a water jacket structure is widely used for electric motors because it has advantages of simple structure and cooling effectiveness. An effective approach to analyze an electric machine with a water jacket is a thermal equivalent network. This network is composed of thermal resistance, a heat source, and thermal capacitance that consider the conduction, convection, and radiation. In particular, modeling of the cooling channel in a network is challenging owing to the flow of the coolant. In this paper, temperature prediction using a thermal equivalent network is performed in an ISG that has a water cooled system. Then, an experiment is conducted to verify the thermal equivalent network.

A Study on the Fuel Cell Equivalent Circuit Modeling (연료전지 수치해석을 이용한 등가회로 모델링 연구)

  • OH, HWANYEONG;CHOI, YOON YOUNG;SOHN, YOUNG-JUN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.3
    • /
    • pp.226-231
    • /
    • 2022
  • Power converter are usually equipped for fuel cell power generation system to connect alternating current (AC) electric power grid. When converting direct current (DC) of fuel cell power source into AC, the power converter has a frequency ripple, which affects the fuel cell and the grid. Therefore, an equivalent circuit having dynamic characteristics of fuel cell power, for example, impedance, is useful for designing an inverter circuit. In this study, the current, voltage and impedance characteristics were calculated through fuel cell modeling and validated by comparing them with experiments. The equivalent circuit element values according to the current density were formulated into equations so that it could be applied to the circuit design. It is expected that the process of the equivalent circuit modeling will be applied to the actual inverter circuit design and simulated fuel cell power sources.

An Efficient Bit-Level Lossless Grayscale Image Compression Based on Adaptive Source Mapping

  • Al-Dmour, Ayman;Abuhelaleh, Mohammed;Musa, Ahmed;Al-Shalabi, Hasan
    • Journal of Information Processing Systems
    • /
    • v.12 no.2
    • /
    • pp.322-331
    • /
    • 2016
  • Image compression is an essential technique for saving time and storage space for the gigantic amount of data generated by images. This paper introduces an adaptive source-mapping scheme that greatly improves bit-level lossless grayscale image compression. In the proposed mapping scheme, the frequency of occurrence of each symbol in the original image is computed. According to their corresponding frequencies, these symbols are sorted in descending order. Based on this order, each symbol is replaced by an 8-bit weighted fixed-length code. This replacement will generate an equivalent binary source with an increased length of successive identical symbols (0s or 1s). Different experiments using Lempel-Ziv lossless image compression algorithms have been conducted on the generated binary source. Results show that the newly proposed mapping scheme achieves some dramatic improvements in regards to compression ratios.

Transmission Line Fault Location Algorithm Using Estimated Local Source Impedance (자기단 전원임피던스 추정을 이용한 송전선 고장점표정 알고리즘)

  • Kwon, Young-Jin;Kim, Su-Hwan;Kang, Sang-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.5
    • /
    • pp.885-890
    • /
    • 2009
  • A fault location algorithm using estimated local source impedance after a fault is proposed in this paper. The method uses after fault data only at the local end. It uses the negative sequence current distribution factor for more accurate estimation. The proposed algorithm can keep up with the variation of the local source impedance. Therefore, the proposed algorithm especially is valid for a transmission line interconnected to a wind farm that the equivalent source impedance changes continuously. The performance of the proposed algorithm was verified under various fault conditions using the Simpowersystem of MATLAB Simulink. The proposed algorithm is largely insensitive to the variation in fault distance and fault resistance. The test results show a very high accurate performance.

Blind Image Separation with Neural Learning Based on Information Theory and Higher-order Statistics (신경회로망 ICA를 이용한 혼합영상신호의 분리)

  • Cho, Hyun-Cheol;Lee, Kwon-Soon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.8
    • /
    • pp.1454-1463
    • /
    • 2008
  • Blind source separation by independent component analysis (ICA) has applied in signal processing, telecommunication, and image processing to recover unknown original source signals from mutually independent observation signals. Neural networks are learned to estimate the original signals by unsupervised learning algorithm. Because the outputs of the neural networks which yield original source signals are mutually independent, then mutual information is zero. This is equivalent to minimizing the Kullback-Leibler convergence between probability density function and the corresponding factorial distribution of the output in neural networks. In this paper, we present a learning algorithm using information theory and higher order statistics to solve problem of blind source separation. For computer simulation two deterministic signals and a Gaussian noise are used as original source signals. We also test the proposed algorithm by applying it to several discrete images.

Control System Design for Self-Commutated Static Var Compensator (전압원인버터방식 송전용 무효전력보상기의 제어시스템 설계)

  • 한병문
    • Proceedings of the KIPE Conference
    • /
    • 1996.06a
    • /
    • pp.89-92
    • /
    • 1996
  • This paper describes a detailed simulation model of the static condenser (STATCON) to analyze the dynamic interaction with the ac transmission line. The static condenser was represented by a 12-pulse voltage-source inverter sharing an energy storage dc capacitor. The voltage-source inverter consists of two 6-pulse bridges modeled with ideal gate-turn-off switches. The control system for the static condenser was designed through a mathematical model deduced from the equivalent circuit. Simulation results show that the conceived model is very effective to analyze the dynamic interaction between the static condenser and the ac transmission system.

  • PDF

Soft-switching Current Source Inverter for Interconnection of Solar Cell with Power System (태양전지의 개통연계를 위한 소프트스위칭 전류원 인버터)

  • Choy, Young-Do;Park, Sang-Ho;Kim, Hee-Joong;Han, Byung-Moon
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.345-347
    • /
    • 2000
  • This paper proses a soft-switching current-source inverter with a switched-capacitor module. The system operation was analyzed by a theoretical approach with equivalent circuits and verified by a computer simulation and experiment. The proposed system could be effectively applied for the power converter of photovoltaic power generation interconnected with the power system.

  • PDF

A Study on the Self-Oscillating Mixer

  • Park, K. D.;S. Sakurazawa;H. Arai
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.05a
    • /
    • pp.132-134
    • /
    • 2000
  • This paper presents self-oscillating mixer(SOM) with simple structure which includes dc source, a cross type groove, and a three terminal GaAsFET. By using parasitic elements such as cooper wires, If level of the active antenna is increased. In order to include active device into FDTD analysis, equivalent voltage source are used to substitute for the active device and to describe the voltage-current relationships. This approach is applied to analyze SOM theoretically.

  • PDF

Analysis of Characteristics in Transformer by using Coupling Coefficient Type Equivalent Circuit (결합계수형 등가회로에 의한 변압기의 특성해석)

  • 이광직;김주홍
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.4
    • /
    • pp.86-92
    • /
    • 1995
  • In the analysis of characteristic behaviors of a real transformer with coupling coefficient K is less than 1, this paper presents the more accurate and practical profits than the traditional analysis of the transformer treated as K∼1. This results from the use of the coupling coefficient type equivalent circuit of the transformer which includes K as positive parameter. Furthermore, a leakage transformer is analyzed in a unified method and the results of analysis are consistent with the practical measurements of the transformer. By using the above equivalent circuit, the characteristics referred to the load side are expressed as Thevenin voltage source and the leakage inductor (1-K2)L2. Therefore, these analysis about the output voltage and the damping factor in the transient state which are affected by the leakage inductor are confirmed to be an effective method.

  • PDF