• Title/Summary/Keyword: Equivalent Evaluation

Search Result 1,010, Processing Time 0.027 seconds

A Comparison Study of Equivalent Strut Models for Seismic Performance Evaluation of Masonry-Infilled Frame (조적채움벽 골조의 내진성능평가를 위한 등가 스트럿 모델의 비교연구)

  • Yu, EunJong;Kim, MinJae;Jung, DaeGye
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.18 no.2
    • /
    • pp.79-87
    • /
    • 2014
  • Masonry-infilled walls have been used in reinforced concrete(RC) frame structures as interior and exterior partition walls. Since these walls are considered as nonstructural elements, they were only considered as additional mass. However, infill walls tend to interact with the structure's overall strength, rigidity, and energy dissipation. Infill walls have been analyzed by finite element method or transposed as equivalent strut model. The equivalent strut model is a typical method to evaluate masonry-infilled structure to avoid the burden of complex finite element model. This study compares different strut models to identify their properties and applicability with regard to the characteristics of the structure and various material models.

A Study on the Reinforced Method of Doubler Plate in Ship Hull Structure (선박 이중판의 보강법 연구)

  • HAM JUH-HYEOK
    • Journal of Ocean Engineering and Technology
    • /
    • v.17 no.5 s.54
    • /
    • pp.39-47
    • /
    • 2003
  • A study of the structural strength evaluation on the doubler plate, considering various load cases that were subjected to in-plane and out of plane combined load, has been performed through the systematic evaluation process. In order to estimate the proper static strength of doubler plate for various load cases, elasto-plastic large deflection analysis is introduced, including the contact effect between main plate and doubler. The characteristics of stiffness and strength variation are discussed, based on the results. In order to compare the doubler structure with the original strength of main plate, without doubler, simple formulas for the evaluation of the equivalent flat plate thickness are derived for each load case, respectively, based on the additional series of analysis of flat plate structure. Using these derived equations, the thickness change of an equivalent flat plate is analyzed according to the variation of various design parameters of doubler platesome design guides are suggested in order to maintain the original strength of main plate without doubler reinforcement. Finally, correlation between derived equivalent flat plate formula and the developed buckling strength formulas are discovered, and these relations are formulated for the future development of simple strength evaluation formula of general doubler plate structure.

Definition and Difference between Dose Equivalent and Equivalent Dose in Radiation Dose Measurement and Evaluation (방사선량의 측정, 평가에서 선량당량(dose equivalent)과 등가선량(equivalent dose)의 정의 및 차이)

  • Chang, Si-Young
    • Journal of Radiation Protection and Research
    • /
    • v.18 no.1
    • /
    • pp.1-7
    • /
    • 1993
  • In its recent recommendation No. 60(1990), ICRP has newly introduced several terminology which had not existed in its prior recommendation No. 26(1977). Of these, a newly defined quantity 'Equivalent Dose' replacing the 'Dose Equivalent' of the ICRU concept has been recommended to be adopted in the radiation protection programme. However, since the committee still uses the 'Dose Equivalent' and 'Equivalent Dose' in its several publications, it is likely to provoke unnecessary confusions and misuses in applying these two quantities. In this paper were described the definition and difference between these two quantities to help in understanding of these two quantitites among the person involved in the radiation protection activities.

  • PDF

Elastic-plastic Finite Element Analysis of Drawbead Forming for Evaluation of Equivalent Boundary Conditions in Sheet Metal Forming - Part II : Application to the front Door Panel Forming Process (박판 성형공정에서의 등가 경계조건 계산을 위한 드로우비드 성형의 탄소성 유한요소 해석 - Part II : 프런트 도어 판넬 성형공정에서의 적용)

  • Park, J.S.;Kim, S.H.;Huh, H.
    • Transactions of Materials Processing
    • /
    • v.11 no.6
    • /
    • pp.513-518
    • /
    • 2002
  • The equivalent boundary conditions have been applied to the front door panel forming process, in order to demonstrate its reliability and validity. The elongation in the bead forming process is applied to the binder wrap process as the equivalent displacement boundary condition and the restraining force in the drawing process is applied to stamping process as the equivalent force boundary condition. The result calculated with the equivalent boundary conditions shows closer coincidence with the experimental result than simulation with different boundary conditions. The numerical result fully demonstrates that drawbead forming simulation for calculation of equivalent boundary conditions is necessary and effective.

Energy Performance Evaluation Study on the Thermal Bridge Blocking External Insulation System for Green Remodeling (그린 리모델링용 열교 차단 외단열 시스템의 에너지 성능 평가 연구)

  • Kim, Woong-Hoi;Kang, Eun-Ho;Yoon, Jong-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.234-235
    • /
    • 2021
  • We set the representative balcony types of the existed building to two types: unexpanded balcony and extended balcony, and analyze the effect of reducing the cooling and heating energy load when applying remodeling. The scope of the study was limited to balcony walls, including window-wall junctions, and was conducted by comparing cases with and without thermal break insulation structures for a clear conclusion. The study was conducted using the equivalent U-value in each case. The equivalent U-value was calculated by deriving through 2 dimensional steady-state heat transfer analysis of each case balcony envelope. And building energy was calculated using the derived equivalent U-value. According to the calculation results, for unexpanded balconies, the equivalent U-value was reduced by about 80%, and the heating and cooling load was reduced by about 20%. In the case of extended balconies, the equivalent U-value was reduced by about 57% and the resulting heating and cooling load was reduced by about 12%.

  • PDF

Application of a Composite Skin Equivalent using Collagen and Acellular Dermal Matrix as the Scaffold in a Mouse Model of Full-thickness Wound (콜라겐과 무세포진피를 이용한 혼합형 인공피부 개발 및 쥐 모델에서 창상치료 적용)

  • Lee, Dong Hyuck;Youn, Jin Chul;Lee, Jung Hee;Kim, In Seop
    • KSBB Journal
    • /
    • v.29 no.1
    • /
    • pp.42-49
    • /
    • 2014
  • The aim of this study was to develop a composite human skin equivalent for wound healing. Collagen type1 and acellular dermal matrix powder were utilized as the scaffold with dermal fibroblasts and keratinocytes for the development of a composite human skin equivalent. Fibroblast maintained the volume of composite skin equivalent and also induced keratinocytes to attach and proliferate on the surface of composite skin equivalent. The composite human skin equivalent had a structure and curvature similar to those of real skin. Balb-C nu/nu mice were used for the evaluation of full-thickness wound healing effect of the composite human skin equivalent. Graft of composite skin equivalent on full-thickness wound promoted re-epithelialization and granulation tissue formation at 9 days. Given the average wound-healing time (14 days), the wound in the developed composite skin equivalent healed quickly. The overall results indicated that this three-dimensional composite human skin equivalent can be used to effectively enhance wound healing.

Numerical Study on Human Model's Shape and Grid Dependency for Indoor Thermal Comfort Evaluation (실내 온열쾌적성 평가를 위한 인체 모델링 및 격자특성에 대한 수치해석적 연구)

  • Park, J.H.;Seo, J.W.;Choi, Y.H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.210-217
    • /
    • 2011
  • Recently, research on evaluating thermal comfort by using CFD has been vigorously active. This research evaluates not only distribution of temperature and air flow analysing but also thermal comfort in indoor space by applying human model. But research of human model's shape, Grid characteristic and turbulence model has not yet been studied. In this paper, human model's shape, physical characteristic of variable Grid, and change of turbulence model has been studies by CFD. In this study. FLUENT is used for analysis and PMV(predicted Mean Vote), PPD(Predicted Percentage Dissatisfied) and EHT(Equivalent Homogeneous Temperature} are used for evaluation and comparison of thermal comfort. As a result, it shows that shape of CSP and lattice features does not affect on global flow field or evaluation on PMV, PPD. However, it demonstrates more precise result from evaluation of thermal comfort by equivalent temperature when it used detailed human model considering prism grid.

  • PDF

Simulation of Aggregate Slump Test Using Equivalent Sphere Particle in DEM (등가 구형입자를 이용한 DEM에서의 골재 슬럼프 실험 모사)

  • Yun, Tae Young;Ahn, Sang Hyeok;Nam, Jueong Hee;Yoo, Pyeong Jun
    • International Journal of Highway Engineering
    • /
    • v.15 no.5
    • /
    • pp.21-29
    • /
    • 2013
  • PURPOSES: Simulation of aggregate slump test using equivalent sphere particle in DEM and its validity evaluation against lab aggregate slump test METHODS : In this research, aggregate slump tests are performed and compared with DEM simulation. To utilize spheric particles in YADE, equivalent sphere diameter concept is applied. As verification measures, the volume in slump cone filled with aggregate is used and it is compared with volume in slump cone filled with equivalent sphere particle. Slump height and diameter are also used to evaluate the suggested numerical method with equivalent concept RESULTS : Simulation test results show good agrement with lab test results in terms of loose packing volume, height and diameter of slumped particle clump. CONCLUSIONS : It is concluded that numerical simulation using DEM is applicable to evaluate the effect of aggregate morphological property in loose packing and optimum gradation determination based on the aggregate slump test simulation result.

Responsivity and Noise Evaluation of Infrared Thermal Imaging Camera (적외선열화상카메라의 응답 및 노이즈 특성 평가)

  • Kim, Dong-Ik;Kim, Ghiseok;Kim, Geon-Hee;Chang, Ki Soo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.4
    • /
    • pp.342-348
    • /
    • 2013
  • In this paper, the evaluation method for the responsivity and noise characteristics of an infrared thermal imaging camera was presented. Signal transfer function and noise equivalent temperature difference of the infrared thermal imaging camera were obtained by using a differential mode blackbody that is able to control the temperature difference ${\Delta}$T between an infrared target and its background. And we verified the suitability of our evaluation method through comparison between the found noise equivalent temperature difference and the specification of the camera. In addition, the difference of 0.01 K of the two noise equivalent temperature differences calculated from with and without nonuniformity correction suggests that the nonuniformity correction is essential process for the evaluation of the infrared thermal imaging camera.