• Title/Summary/Keyword: Equipment contamination

Search Result 196, Processing Time 0.03 seconds

Development of Wireless Real-Time Gas Detector System for Chemical Protection Performance Test of Personal Protective Equipment (화생방 보호의 성능평가를 위한 무선 실시간 가스 검출기 개발)

  • Kah, Dong-Ha
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.294-301
    • /
    • 2020
  • Man-In-Simulant Test(MIST) provides a test method to evaluate chemical protective equipments such as protective garments, gloves, footwear and gas mask. The MIST chamber is built to control concentration of chemical vapor that has a activity space for two persons. Non-toxic methyl-salicylate(MeS) is used to simulate chemical agent vapor. We carried out to measure inward leakage MeS vapors by using passive adsorbent dosimeter(PAD) which are placed on the skin at specific locations of the body while man is activity according to the standard procedure in MIST chamber. But more time is required for PADs and there is concern of contamination in PADs by recovering after experiment. Therefore detector for measuring in real time is necessary. In order to analyze in real time the contamination of the personal protective equipment inside the chemical environment, we have developed a wireless real-time gas detector. The detector consists of 8 gas-sensors and 1 control-board. The control-board includes a CPU for processing a signal, a power supply unit for biasing the sensor and Bluetooth-chipset for transmission of signals to external PC. All signals from gas-sensors are converted into digital signals simultaneously in the control-board. These digital signals are stored in external PC via Bluetooth wireless communication. The experiment is performed by using protective equipment worn on manikin. The detector is mounted inside protective equipment which is capable of providing a real-time monitoring inward leakage MeS vapor. Developed detector is demonstrated the feasibility as real-time detector for MIST.

The AS4059 Hydraulic System Cleanliness Classification System: Replacement of NAS1638

  • Day, Mik;Hong, Jeong-Hee
    • Journal of Drive and Control
    • /
    • v.9 no.2
    • /
    • pp.39-45
    • /
    • 2012
  • The NAS 1638 cleanliness classification system was originally developed in 1966 by the US Aircraft Industries of America to both simplify reporting of particle count data and to control the introduction of dirt during the assembly of aircraft fluid systems. The numbers of particles at stated sizes are represented by broad bands where the interval was generally a doubling of contamination. A number of systems have been introduced since this to suit differing requirements. NAS 1638 and AS4059 are used in other industrial sectors such as the Off-shore & Sub-Sea and the Primary Metal Industries. The changes to ISO contamination measurement standards controlled by ISO/TC131/SC6 in 1999 meant that a revision of most of these classification systems was necessary. The body responsible for NAS 1638 decided to withdraw it for new installations and replace it with an update of an existing standard, SAE AS 4059. This paper details the philosophy behind the contamination coding systems, the reasons for the changes to the ISO contamination standards and explains the workings of AS 4059, the replacement for NAS 1638. It goes on to detail the latest changes to this standard.

Development of Automatic Smear Equipment for Measuring Surface Radioactivity Contamination (표면방사선 오염도 측정용 자동 스미어장치의 개발)

  • Tack, Han-Ho;Kang, Shin-Chool
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.16 no.4
    • /
    • pp.37-44
    • /
    • 2011
  • This paper was development of surface contamination automatic smear sampling for measuring radioactive contamination in radiation controlled area of nuclear facility. In indirect method a smear paper are used manually. Activity on the smear paper is affected by varying the pressures applied, by the smearing time, by the difference of ares sampled during smearing. By means of these there are erroneous. In the future the apparatus will be developed as a portable apparatus measuring smear activity automatically by adding radiation detection instrument.

Contamination Particle and Cracking Behavior of the Anodic Oxidation in Sulfuric Acid Containing Cerium Salt (세륨염을 첨가한 황산법 양극산화피막의 오염입자 및 열크랙 거동)

  • So, Jongho;Yun, Ju-Young;Shin, Jae-Soo
    • Journal of the Semiconductor & Display Technology
    • /
    • v.17 no.4
    • /
    • pp.11-15
    • /
    • 2018
  • The parts of equipment for semiconductor are protected by anodic aluminum oxide film to prevent corrosion. This study investigated contamination particle and cracking behavior of anodic oxidation in sulfuric acid containing cerium salt. The insulating properties of the sample were evaluated by measuring the breakdown voltage. It was confirmed that the breakdown voltage was about 50% higher when the cerium salt was added, and that the breakdown voltage after the heat treatment was 55% and 35% higher at $300^{\circ}C$ and $400^{\circ}C$, respectively. After heating at $300^{\circ}C$ and $400^{\circ}C$, cracks were observed in non cerium and cerium 3mM, and more cracks occur at $400^{\circ}C$ than at $30^{\circ}C$. The amount of contamination particles generated in the plasma is about 45% less than that of non-cerium specimens.

Time Shifted Pilot Signal Transmission With Pilot Hopping To Improve The Uplink Performance of Massive MIMO System For Next Generation Network

  • Ruperee, Amrita;Nema, Shikha
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.9
    • /
    • pp.4390-4407
    • /
    • 2019
  • The paucity of pilot signals in Massive MIMO system is a vital issue. To accommodate substantial number of users, pilot signals are reused. This leads to interference, resulting in pilot contamination and degrades channel estimation at the Base Station (BS). Hence, mitigation of pilot contamination is exigency in Massive MIMO system. The proposed Time Shifted Pilot Signal Transmission with Pilot signal Hopping (TSPTPH), addresses the pilot contamination issue by transmitting pilot signals in non-overlapping time interval with hopping of pilot signals in each transmission slot. Hopping is carried by switching user to new a pilot signal in each transmission slot, resulting in random change of interfering users. This contributes to the change in channel coefficient, which leads to improved channel estimation at the BS and therefore enhances the efficiency of Massive MIMO system. In this system, Uplink Signal Power to Interference plus Noise Power Ratio (SINR) and data-rate are calculated for pilot signal reuse factor 1 and 3, by estimating the channel with Least Square estimation. The proposed system also reduces the uplink Signal power for data transmission of each User Equipment for normalized spectral efficiency with rising number of antennas at the BS and thus improves battery life.

Prevention of P-i Interface Contamination Using In-situ Plasma Process in Single-chamber VHF-PECVD Process for a-Si:H Solar Cells

  • Han, Seung-Hee;Jeon, Jun-Hong;Choi, Jin-Young;Park, Won-Woong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.204-205
    • /
    • 2011
  • In thin film silicon solar cells, p-i-n structure is adopted instead of p/n junction structure as in wafer-based Si solar cells. PECVD is a most widely used thin film deposition process for a-Si:H or ${\mu}c$-Si:H solar cells. For best performance of thin film silicon solar cell, the dopant profiles at p/i and i/n interfaces need to be as sharp as possible. The sharpness of dopant profiles can easily achieved when using multi-chamber PECVD equipment, in which each layer is deposited in separate chamber. However, in a single-chamber PECVD system, doped and intrinsic layers are deposited in one plasma chamber, which inevitably impedes sharp dopant profiles at the interfaces due to the contamination from previous deposition process. The cross-contamination between layers is a serious drawback of a single-chamber PECVD system in spite of the advantage of lower initial investment cost for the equipment. In order to resolve the cross-contamination problem in single-chamber PECVD systems, flushing method of the chamber with NH3 gas or water vapor after doped layer deposition process has been used. In this study, a new plasma process to solve the cross-contamination problem in a single-chamber PECVD system was suggested. A single-chamber VHF-PECVD system was used for superstrate type p-i-n a-Si:H solar cell manufacturing on Asahi-type U FTO glass. A 80 MHz and 20 watts of pulsed RF power was applied to the parallel plate RF cathode at the frequency of 10 kHz and 80% duty ratio. A mixture gas of Ar, H2 and SiH4 was used for i-layer deposition and the deposition pressure was 0.4 Torr. For p and n layer deposition, B2H6 and PH3 was used as doping gas, respectively. The deposition temperature was $250^{\circ}C$ and the total p-i-n layer thickness was about $3500{\AA}$. In order to remove the deposited B inside of the vacuum chamber during p-layer deposition, a high pulsed RF power of about 80 W was applied right after p-layer deposition without SiH4 gas, which is followed by i-layer and n-layer deposition. Finally, Ag was deposited as top electrode. The best initial solar cell efficiency of 9.5 % for test cell area of 0.2 $cm^2$ could be achieved by applying the in-situ plasma cleaning method. The dependence on RF power and treatment time was investigated along with the SIMS analysis of the p-i interface for boron profiles.

  • PDF

Bacterial Contamination of Surfaces in an Ultrasound Room (초음파실 표면의 세균 오염평가)

  • Kim, Hee-jeong;Choi, Yujin;Lee, Chang-Lae
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.231-237
    • /
    • 2021
  • The ongoing coronavirus disease 2019 (COVID-19) pandemic has highlighted the importance of hospital hygiene and infection control in hospital settings. To raise hygiene awareness among ultrasound technicians, we evaluated the hygiene status of an ultrasound room, in comparison with that of objects used in daily life. Using the swab method, the following surfaces were examined: eight surfaces in the ultrasound room including the ultrasound probes (convex, linear, sector, 3D), ultrasound track ball, ultrasound keyboard, ultrasound gel (sealed and in use) and pillow as well as four surfaces of everyday objects including subway handles, common computer keyboards, common computer mouse, and cell phones. The streak plate technique was used for inoculation into media, which was observed for the formation of bacterial colonies following incubation for 24 h. Six bacterial strains were detected from objects used in the ultrasound room, including methicillin-resistant Staphylococcus aureus. Four strains of bacteria were detected on surfaces of everyday objects. The equipment and accessories used in an ultrasound room can act as vehicles for infecting patients. Establishment of standardized hygiene protocols and periodic training of the staff are recommended to avoid cross-infection.

Identification of Pork Contamination in Meatballs of Indonesia Local Market Using Polymerase Chain Reaction-Restriction Fragment Length Polymorphism (PCR-RFLP) Analysis

  • Erwanto, Yuny;Abidin, Mohammad Zainal;Muslim, Eko Yasin Prasetyo;Sugiyono, Sugiyono;Rohman, Abdul
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.27 no.10
    • /
    • pp.1487-1492
    • /
    • 2014
  • This research applied and evaluated a polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP) using cytochrome b gene to detect pork contamination in meatballs from local markets in Surabaya and Yogyakarta regions, Indonesia. To confirm the effectiveness and specificity of this fragment, thirty nine DNA samples from different meatball shops were isolated and amplified, and then the PCR amplicon was digested by BseDI restriction enzyme to detect the presence of pork in meatballs. BseDI restriction enzyme was able to cleave porcine cytochrome b gene into two fragments (131 bp and 228 bp). Testing the meatballs from the local market showed that nine of twenty meatball shops in Yogyakarta region were detected to have pork contamination, but there was no pork contamination in meatball shops in Surabaya region. In conclusion, specific PCR amplification of cytochrome b gen and cleaved by BseDI restriction enzymes seems to be a powerful technique for the identification of pork presence in meatball because of its simplicity, specificity and sensitivity. Furthermore, pork contamination intended for commercial products of sausage, nugget, steak and meat burger can be checked. The procedure is also much cheaper than other methods based on PCR, immunodiffusion and other techniques that need expensive equipment.

Bacterial Contamination of Digital Panoramic Dental X-Ray Equipment

  • Lee-Rang Im;Ji-Hyun Min;Ki-Rim Kim
    • Journal of dental hygiene science
    • /
    • v.23 no.4
    • /
    • pp.343-350
    • /
    • 2023
  • Background: Digital panoramic dental X-ray equipment (PDX) is frequently used by patients and dental workers for diagnosis and examination in dental institutions; however, infection control has not been properly implemented. Therefore, in this study, we aimed to systematically review the potential risk of cross-infection in the dental environment by investigating the contamination level of general aerobic bacteria and Staphylococcus aureus, which are important in hospital infections, in PDX areas that people mainly contact. Methods: This survey was conducted from March to May 2023 and covered one general hospital, three dental hospitals, and nine dental clinics equipped with PDX. Bacteria samples were collected from the left-handle, right-handle, forehead support, and head side support as the patient's contact areas, as well as the X-ray exposure switch and left-click mouse button as the dental hygienist's contact areas of the PDX. The collected bacteria were spread on Petrifilm, and colonies formed after 48 hours of culture were counted. Results: General aerobic bacteria and S. aureus were detected in all areas investigated. Significant differences in bacterial counts between different regions of the PDX were observed in both groups (p<0.001). The detection rates of general aerobic bacteria (p<0.001) and S. aureus (p<0.001) were significantly higher in the contact areas of patients than those of dental hygienists. A positive correlation was observed between the forehead and the temple region in terms of general aerobic bacteria and S. aureus detection (r=1) (p<0.01). Conclusion: Taken together, the presence of many bacteria, including S. aureus, detected in PDX indicates that PDX has a potential cross-infection risk. Our results therefore highlight the need for the development of appropriate disinfection protocols for reusable medical devices such as PDX and periodic infection prevention training for hospital-related workers, including dental hygienists.

Analysis of Bacterial Contamination on Surface of General Radiography Equipment and CT Equipment in Emergency Room of Radiology (영상의학과 응급실내의 일반촬영장비와 전산화단층촬영장비 표면에서의 세균 오염에 관한 분석)

  • Hong, Dong-Hee;Kim, Hyeong-Gyun
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.421-427
    • /
    • 2016
  • We aim to offer basic materials about infection management through conducting bacterial contamination test about general radiography equipment and CT equipment installed in ER of three general hospitals with 100 sickbeds or more located in Gyeongsangbuk-do Province, and suggest management plan. It had been conducted from 1st December 2015 to 31st December, and objects were general radiography equipment and CT equipment of emergency room located in Gyeongsangbuk-do Province. For general radiography equipment, sources were collected from 4 places such as upper side of control box which employees use most, upper side of exposure button, whole upper side of table which is touching part of patient's skin, upper side of stand bucky's grid, and where patients put their jaws on. For CT equipment, sources were collected from 3 places such as upper side of control box which radiography room employees use most, X-ray exposure button, whole upper side of table which is touching part of patient's skin, and gantry inner. Surface contamination strain found at general radiography equipment in emergency room of radiology are Providencia stuartii(25%), Stenotrophomonas maltophilia(18%), Enterobacter cloacae(8%), Pseudomonas species(8%), Staphylococcus epidermidis(8%), Gram negative bacilli(8%), and ungrown bacteria at incubator after 48 hours of incubation (67%) which is the biggest. Most bacteria were found at upper side of stand bucky-grid and stand bucky of radiology's general radiography equipment, and most sources of CT equipment were focused at patient table, which means it is contaminated by patients who have various diseases, and patients who have strains with decreased immunity may get severe diseases. Thus infection prevention should be made through 70% alcohol disinfection at both before test and after test.