• Title/Summary/Keyword: Equipment Maintenance Cost

Search Result 252, Processing Time 0.037 seconds

A survey of the status of hair loss product use, hair loss treatment and satisfaction level (탈모(脫毛) 고객(顧客)의 제품이용실태와(製品使用實態) 관리(管理) 및 만족도(滿足度) 조사(調査))

  • Lee, Ji-Suk;Kim, Sung-Nam
    • Journal of Fashion Business
    • /
    • v.11 no.2
    • /
    • pp.76-91
    • /
    • 2007
  • The domestic market for scalp care and hair loss management reached 1 trillion won. The market for hair loss management is expected to expand further. Systematic scalp and hair care services, such as scalp scaling, scalp massage, equipment maintenance, scalp care products sale, and care program based on scalp and trichology are provided. This study examined the status of hair loss management and use of hair care products by people experiencing hair loss and the level of their satisfaction. In addition, this study presents basic data for the effective hair loss management and marketing strategies for scalp and hair loss clinics. The results are as follows. 41.2% of the study subjects were in their 20s, and 66.6% of the study subjects were women. As for the hair loss symptoms, 45.2%, the largest percentage, had thin and wispy hair and more women had thin hair than men. 80.0% of men had oily hair. As for the scalp condition, 39,3% had oily scalp. As more women experience hair loss, 39.6% had female pattern hair loss and 31.0% had male pattern hair loss. As the largest percentage of people experiencing hair loss was in their 20s, 33.4%, the largest percentage, had the onset of hair loss in their early 20s. 34.1%, the largest percentage, reported having used the clinic for less than 1 month. The older the subject, the longer the length of hair clinic use. As for the average number of monthly hair loss clinic visits, 28.2%, the largest percentage, said 3 times. As for the hair loss management product use, 61.9%, said they do not use it and 38.1% said they use it. 5.6%, the largest percentage, used Davines at home and 9.6%, the largest percentage, used Kerastase at the clinic. As for the experience of hair loss product previously, 84.5% said they had no experience and 15.5% said they had eThe following are related to the satisfaction level of hair loss management. xperience. 5.0%, the largest percentage, reported having used Daenggimeori. The following are related to the satisfaction level of hair loss management. 32.8%, the largest percentage, said the effect of hair loss management lasted less than 6 monthas. As for the satisfaction levels on hair loss management program, service, skill of the hair specialist, hygiene, and hair loss management products, most people indicated between average and somewhat satisfactory levels. As for the satisfaction level on the cost of hair loss management, most people indicated average satisfaction level. As for the element essential to hair loss management, 39.0%, the largest percentage, indicated development of effective and specialized programs, 28.2%, indicated low price, 25.1%, indicated systematic and professional education of the hair specialist, 4.6%, indicated marketing and promotion, 2.5%, indicated service quality, and 0.6% indicated others.

A Study on the Applicability of PDA Technique in the P-CAP System for T-P Removal of STP Effluent (하수처리장 방류수의 총인 제거를 위한 P-CAP 시스템에서 PDA 기법의 활용가능성에 대한 연구)

  • Choi, Choongho;Maeng, Sungkyu;Sim, Jaehwi;Choi, Jinho;Song, Kyungguen;Lee, Byungha;Cha, Hoyoung
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.5
    • /
    • pp.729-742
    • /
    • 2012
  • Recently, to using chemical coagulation process for T-P removal in STP effluent as tertiary treatment process is generalized in the country. The importance of analysis technique to save the treatment & maintenance cost during coagulation process is becoming more increased each day. Thus, it is necessary for the analysis technique during coagulation process to be presented well the characteristic of coagulation in field apply. There are a few analysis techniques such as Jar Test, zeta potential analysis and streaming current detecting techniques. But there are difficult to apply in field immediately due to long test time and difficult analysis techniques. And using PDA technique, it is reviewed applicability of the techniques as field index on pilot plant of P-CAP system The P-CAP system is composed of an in-line static mixer, a Flocculation Tank and the CAP reactor with 2 stage weir for effluent. Pre-test is performed to fix the mixing velocity in the Flocculation Tank using the PDA equipment and it fixed with 30RPM. Also, Jar Test is performed to select optimum dose of each coagulant for each T-P concentration level of influent. Result of continuous test on pilot plant of P-CAP system, the FSI in the Flocculation Tank is increased consistently by increasing each dosing concentration of coagulant such as LAS and PAC in the low level influent T-P concentration comparatively. It is considered that formed Al-hydroxide complexes for dosed coagulant are caused FSI variation. Furthermore, it seems that FSI value in the high level influent T-P concentration appeared lower than the opposite influent condition relatively because it is formed simultaneously Al-hydroxide complexes as solid type and Al-phosphorus complexes as soluble type. Thus, relation of FSI by PDA technique and T-P removal of final effluent on pilot plant of P-CAP system are very limited for the kind of coagulant and the characteristics of influent. And it though that FSI value by PDA technique with analyzing of turbidity in Flocculation Tank will be used restrictedly on field as the relative field-index.

Aging of Fermented shrimp in underground cave (토굴을 이용한 새우젓의 숙성)

  • Lee, Eun Hyun;Lee, Eun Mi;Chang, Kyu Seob;Jang, Hae Dong
    • Korean Journal of Agricultural Science
    • /
    • v.24 no.2
    • /
    • pp.132-137
    • /
    • 1997
  • Effective storage facilities are required to stabilize the price of agricultural and marine products to preserve their qualities due to the big fluctuation of shrimp price in Korea. It is easy to make the cave because of good conditions of the land configuration, soil and convenient transportation. The cave storage can save the cost about 40% in building site and equipment, and about 50% in maintenance comparing to existing low temperature storage facilities. The cave storage provide to improve the quality of their stored products with the low heat conductivity, the constant temperature and humidity year round. Therefore, more low temperature storage facilities are required because the items are expanded from potatoes, sweet potatoes, onions, garlics, apples and chestnuts to tangerines, grapes, cabbages, radishes, and wet ginsengs. The demands of the low temperature storage facilities can be substituted into the cave storage facilities. Thus, studies are conducted to observe the changes of the components of the pure and the seasoned salted shrimps with fermentation period during stored at room temperature in cave and to establish the storing at underground facilities to produce high quality salted fish to make profit.

  • PDF

Economic analysis of integrated data analysis at variety marine protocols (다양한 해양 프로토콜의 분류 및 통합 데이터를 분석한 독립서버에 대한 경제적 분석)

  • Jang, Hyun-Young;Jang, Jong-Wook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.243-246
    • /
    • 2016
  • Data transfer technique is one of the key elements of the IT infrastructure, in accordance with each environment and function, using some kind of protocol. Using the three protocols such as WCDMA, AIS, and TRS at sea IT industry. so It uses three protocols saw has a problem that the operation of each protocol-specific server. so server maintenance costs increase and sea Device Manager has been placed in a situation which operates to develop each of the protocol-specific analysis program. The reason of the protocol is divided into three, marine equipment (lighthouses, buoys, light buoy) manufacturing companies and the date of manufacture, such as, communication environment (distance, communication speed) because such is wrong all, trying to unify this and enormous cost and time is a situation that can not be the exchange occurred when. So in the Ministry of Maritime Affairs and Fisheries, the number of frequency of use is low, communication performance is seeking to refrain from Kure each local organizations and companies the use of low TRS protocol. his paper is intended to conduct research on the basis of the actual data to analyze whether the method is how economical to store a single DB by analyzing other types of protocols. This reduces the shortage of marine IT industry, even a little, shall helps reduce administrative costs.

  • PDF

Development of Digital Streamer System for Ultra-high-resolution Seismic Survey (초고해상 탄성파 탐사를 위한 디지털 스트리머 시스템 개발)

  • Shin, Jungkyun;Ha, Jiho;Yoon, Seongwoong;Im, Taesung;Im, Gwansung
    • Geophysics and Geophysical Exploration
    • /
    • v.25 no.3
    • /
    • pp.129-139
    • /
    • 2022
  • Analog-based streamers for ultra-high-resolution seismic surveys are capable of additional noise ingress in water, but the specifications cannot be expanded through interconnections. Foreign-produced digital streamers have been introduced and used primarily at domestic research institutes; however, the cost is high and smooth maintenance is challenging. This study investigates the localization of ultra-high-resolution digital streamers capable of high-resolution imaging of a geological structure. A digital streamer capable of 24-bit, 10 kHz digital sampling of up to 64 channel data was developed through research and development. Various quantitative specifications of the system were designed and developed close to the benchmark model, Geometrics' GeoEel streamer, and the number of modules that make up the system was drastically reduced, reducing development costs and making it easier to use. The field applicability of the developed streamer system was evaluated in an in situ experiment conducted in the waters around the Port of Yeong-il Bay in Pohang in April 2022.

The Effective Approach for Non-Point Source Management (효과적인 비점오염원관리를 위한 접근 방향)

  • Park, Jae Hong;Ryu, Jichul;Shin, Dong Seok;Lee, Jae Kwan
    • Journal of Wetlands Research
    • /
    • v.21 no.2
    • /
    • pp.140-146
    • /
    • 2019
  • In order to manage non-point sources, the paradigm of the system should be changed so that the management of non-point sources will be systematized from the beginning of the use and development of the land. It is necessary to change the method of national subsidy support and poeration plan for the non-point source management area. In order to increase the effectiveness of the non-point source reduction project, it is necessary to provide a minimum support ratio and to provide additional support according to the performance of the local government. A new system should be established to evaluate the performance of non-point source reduction projects and to monitor the operational effectiveness. It is necessary to establish the related rules that can lead the local government to take responsible administration so that the local governments faithfully carry out the non-point source reduction project and achieve the planned achievement and become the sustainable maintenance. Alternative solutions are needed, such as problems with the use of $100{\mu}m$ filter in automatic sampling and analysis, timely acquisition of water sampling and analysis during rainfall, and effective management of non-point sources network operation management. As an alternative, it is necessary to consider improving the performance of sampling and analysis equipment, and operate the base station. In addition, countermeasures are needed if the amount of pollutant reduction according to the non-point source reduction facility promoted by the national subsidy is required to be used as the development load of the TMDLs. As an alternative, it is possible to consider supporting incentive type of part of the maintenance cost of the non-point source reduction facility depending on the amount of pollutants reduction.

Measurement and Quality Control of MIROS Wave Radar Data at Dokdo (독도 MIROS Wave Radar를 이용한 파랑관측 및 품질관리)

  • Jun, Hyunjung;Min, Yongchim;Jeong, Jin-Yong;Do, Kideok
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.32 no.2
    • /
    • pp.135-145
    • /
    • 2020
  • Wave observation is widely used to direct observation method for observing the water surface elevation using wave buoy or pressure gauge and remote-sensing wave observation method. The wave buoy and pressure gauge can produce high-quality wave data but have disadvantages of the high risk of damage and loss of the instrument, and high maintenance cost in the offshore area. On the other hand, remote observation method such as radar is easy to maintain by installing the equipment on the land, but the accuracy is somewhat lower than the direct observation method. This study investigates the data quality of MIROS Wave and Current Radar (MWR) installed at Dokdo and improve the data quality of remote wave observation data using the wave buoy (CWB) observation data operated by the Korea Meteorological Administration. We applied and developed the three types of wave data quality control; 1) the combined use (Optimal Filter) of the filter designed by MIROS (Reduce Noise Frequency, Phillips Check, Energy Level Check), 2) Spike Test Algorithm (Spike Test) developed by OOI (Ocean Observatories Initiative) and 3) a new filter (H-Ts QC) using the significant wave height-period relationship. As a result, the wave observation data of MWR using three quality control have some reliability about the significant wave height. On the other hand, there are still some errors in the significant wave period, so improvements are required. Also, since the wave observation data of MWR is different somewhat from the CWB data in high waves of over 3 m, further research such as collection and analysis of long-term remote wave observation data and filter development is necessary.

Development of VOCs Treatment Technology using High Efficiency Hybrid System with Multi-Scrone (멀티 선회류식 세정장치를 이용한 고효율 하이브리드 VOCs 습식처리 SYSTEM 개발)

  • Lim, Seong-Il;Kim, Nor-Jung;Kim, Sun-Mi;Lee, Seong-Hun;Kim, Sun-Uk;Chang, Won-Seok;Park, Dae-Won;Kim, Lae-Hyun;Kim, Jae-Hyung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.7
    • /
    • pp.491-498
    • /
    • 2009
  • We studied to develop high-efficiency removal system of odor and VOCs(Volatile Organic Compounds) from environmental infrastructure facilities and oil refineries, painting facilities and so on. It can replace RTO and RCO. We tried an removal experiment for VOCs (toluene, xylene, benzene, MEK(methyl ethyl ketone), ethanol, formalin etc. and odor compounds (hydrogen sulfide, etc.). In process, as pre-treatment we used the scrubber with vortex flow (Multi-scrone) to remove the hydrophilic VOCs and as post-treatment, used fibrous bio-filter to remove the hydrophobic VOCs. This hybrid system remove with high efficiency both the hydrophilic VOCs and hydrophobic VOCs. And we tried to make this system to be compact. In experiment using Multi-scrone, contact time is 2~3 seconds and absorption scrubbing water is diaphragm-type electrolysis water. hydrophilic VOCs like ethanol and relatively hydrophilic odor compounds like hydrogen sulfide is excellent, these substances has been removed almost completely, respectively 95~99%, 93~97%. And for MEK, formalin also Showed a high removal efficiency, respectively 78~90%, 72~85%. But in experiment using Multi-scrone, the hydrophobic VOCs like BTX showed a low removal efficiency, respectively 16~22%, 12~18%, 8~16%. In hydrophobic VOCs, toluene removal experiment using fibrous bio-filter, early efficiency was low but after 10days, adaptation period showed high efficiency 85~95%. but in the mixed phase, toluene and MEK efficiency reduced 5~10%. this show microorganism treat first MEK easy to remove. The removal efficiency for MEK using the fibrous biofilter was stable, 80~92%. This hybrid system is also high economical efficiency for RTO. This system reduce more than 50% the cost of equipment and maintenance. As a result, we expect this technology is in the limelight as high efficiency treatment of VOCs in mid-low price.

Development of tracer concentration analysis method using drone-based spatio-temporal hyperspectral image and RGB image (드론기반 시공간 초분광영상 및 RGB영상을 활용한 추적자 농도분석 기법 개발)

  • Gwon, Yeonghwa;Kim, Dongsu;You, Hojun;Han, Eunjin;Kwon, Siyoon;Kim, Youngdo
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.8
    • /
    • pp.623-634
    • /
    • 2022
  • Due to river maintenance projects such as the creation of hydrophilic areas around rivers and the Four Rivers Project, the flow characteristics of rivers are continuously changing, and the risk of water quality accidents due to the inflow of various pollutants is increasing. In the event of a water quality accident, it is necessary to minimize the effect on the downstream side by predicting the concentration and arrival time of pollutants in consideration of the flow characteristics of the river. In order to track the behavior of these pollutants, it is necessary to calculate the diffusion coefficient and dispersion coefficient for each section of the river. Among them, the dispersion coefficient is used to analyze the diffusion range of soluble pollutants. Existing experimental research cases for tracking the behavior of pollutants require a lot of manpower and cost, and it is difficult to obtain spatially high-resolution data due to limited equipment operation. Recently, research on tracking contaminants using RGB drones has been conducted, but RGB images also have a limitation in that spectral information is limitedly collected. In this study, to supplement the limitations of existing studies, a hyperspectral sensor was mounted on a remote sensing platform using a drone to collect temporally and spatially higher-resolution data than conventional contact measurement. Using the collected spatio-temporal hyperspectral images, the tracer concentration was calculated and the transverse dispersion coefficient was derived. It is expected that by overcoming the limitations of the drone platform through future research and upgrading the dispersion coefficient calculation technology, it will be possible to detect various pollutants leaking into the water system, and to detect changes in various water quality items and river factors.

A Comparative Study of Production of [68Ga]PSMA-11 with or without Cassette Type Modules (비 카세트 방식과 카세트 방식을 이용한 [68Ga]PSMA-11의 자동 합성 방법 비교)

  • Hyun-Sik, Park;Byeong-Min, Jo;Hyun-Ho, An;Hong-Jin, Lee;Jin-Hyeong, Lee;Gyeong-Jae, Lee;Byung-Chul, Lee;Won-Woo, Lee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.2
    • /
    • pp.15-19
    • /
    • 2022
  • Purpose [68Ga]PSMA-11 is needed the high reproducibility, excellent radiochemical yield and purity. In term of radiation safety, the radiation exposure of operator for its production also should be considered. In this work, we performed a comparative study for the fully automated synthesis of [68Ga]PSMA-11 between non-cassette type and cassette type. Materials and Methods Two different type of modules (TRACERlab FX N pro for non-cassette type and BIKBox for cassette type) were used for the automated production of [68Ga]PSMA-11. According to the previously identified elution profile, Only 2.5 ml with high radioactivity was used for the reaction. After adjusting the pH of the reaction solution with HEPES buffer solution, the precursor was added and reacted with at 95 ℃ for 15 minutes. The reaction mixture was separated and purified using a C18 light cartridge. The product was eluted with 50% EtOH/saline solution and diluted with saline. It was completed by sterilizing filter. In the non-cassette type, the aforementioned process must be prepared directly. However, in the cassette method, synthesis was possible simply by installing a kit that was already completed. Results Both total [68Ga]PSMA-11 production time were 25±3(non-cassette type) and 23±3 minutes(cassette type). The radiochemical yield of the non-cassette type(65.5±5.7%) was higher than that of the cassette type(61.6±4.8%) after sterilization filter. The non-cassette type took about 120 minutes of preparation time before synthesis due to washing of synthesizer and reagent preparation. However, since the cassette type does not require washing and reagent preparation, it took about 20 minutes to prepare before synthesis. Both type of synthesizer had a radiochemical high purity(>99%). Conclusion The non-cassette type production of [68Ga]PSMA-11 showed higher radiochemical yield and lower cost than the cassette type. However, The cassette type has an advantage in terms of preparation time, convenience, and equipment maintenance.