• Title/Summary/Keyword: Equipment Contamination

Search Result 196, Processing Time 0.027 seconds

On-Site Treatment of Soil Contaminated by Heavy Metals and Petroleum using Relocatable Soil Washing Equipment

  • Kim, Taeeung
    • International journal of advanced smart convergence
    • /
    • v.9 no.1
    • /
    • pp.19-28
    • /
    • 2020
  • We studied the on-site treatment of soil contaminated by heavy metals and petroleum was tested using relocatable soil washing equipment for greater remediation efficiency. Different combinations of pH and solid/liquid ratio were tested to determine the optimum balance, settling on values of 5 and 1:2, respectively. Next, soils containing Pb, Hg, and petroleum were further tested to assess the optimum number of washing cycles. The remediation efficiency of Pb and Hg in soil contaminated solely by heavy metals was 90.1% and 86.4% after three and two washings, respectively. The remediation efficiency of petroleum in soil contaminated solely by petroleum was 98.8% after one washing. When soil contaminated by both heavy metals and petroleum was cleaned, up to 91.0% of Pb, 86.9% of Hg, and 96.1% of petroleum was removed after two, one, and one washings, respectively. We conducted all remediation efficiencies and concentration reductions satisfied the standard threshold for soil contamination in South Korea.

Flat Panel Display Deflection Analysis Considering Lift Force in Non-Contact Flat Panel Display Conveyer System (비접촉 평판 디스플레이 이송장치에서 양력을 고려한 평판 디스플레이의 처짐 해석)

  • Hwang, Sung-Hyen;Choi, Hyeon-Chang;Lho, Te-Jung;Son, Te-Yong;Park, Bum-Suk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.5
    • /
    • pp.451-457
    • /
    • 2008
  • Flat Panel Display(FPD) is widely used a video display terminals to consumer products of LCD and PDP. The contamination and damage were affected by using the previous contact conveyor's method. In this paper, it analyzes the FPD deflection to develop the non-contact FPD transfer process using lift force. Each conveyor's equipment is called a horizontal conveyor, vertical conveyor and robot pick-up equipment. As result of an analysis of FPD panel's deflection, a robot pick-up equipment has performed according to under the present conditions like panel's weight and loaded glass to move FPD panel from one place to other places properly. Results of the analysis showed 0.474 mm, 0.424 mm and 1.237 mm. Those values are lower than a predicted optimum values : 2 mm for both horizontal and vertical conveyers; 5 mm for robot pick-up equipment. Therefore, those results verify each equipment have safety and reliability.

Research on Sanitation Control for an HACCP Application for a Flatfish (Paralichthys olivaceus) Aquaculture Farm (넙치 양식장 HACCP 적용을 위한 위생관리에 대한 연구)

  • Jee, Bo-Young;Min, Jin-Gi;Kim, Tae-Jin;Choi, Jae-Suk;Park, Sun-Mee
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.25 no.5
    • /
    • pp.1179-1191
    • /
    • 2013
  • Many sanitation control problems due to aging facilities and equipment were identified when applying an HACCP system to a flatfish (Paralichthys olivaceus) aquaculture farm. Specifically, the major problems included a lack of awareness about worker hygiene, lack of management of the use of fish medicines, and vulnerability to secondary contamination by cross-contamination owing to a failure to separate breeding tools used for healthy and unhealthy fish. Therefore, the management standards on the farm regarding the surrounding environment, facilities and equipment, breeding tools, feed and medication, and the hygiene of practitioners must be improved. The hygiene management standards were divided into different procedures such as the management of farm hygiene and environmental sanitation, facilities and equipment, fish hygiene, feed, medications, water, and the stocking and shipping of fish. For each procedure, we established the management standards, inspection period, inspection procedures, and how to deal with errors that occur, to enable hygiene management by a small number of managers. Additionally, an inspection system and record form to implement an HACCP system were developed to maintain systematic management. The management and inspection of all aspects of the farm were designed to be easily managed by the supervisor.

Bacterial Contamination and Disinfection Status of Laryngoscopes Stored in Emergency Crash Carts

  • Choi, Jae Hyung;Cho, Young Soon;Lee, Jung Won;Shin, Hee Bong;Lee, In Kyung
    • Journal of Preventive Medicine and Public Health
    • /
    • v.50 no.3
    • /
    • pp.158-164
    • /
    • 2017
  • Objectives: To identify bacterial contamination rates of laryngoscope blades and handles stored in emergency crash carts by hospital and area according to the frequency of intubation attempts. Methods: One hundred forty-eight handles and 71 blades deemed ready for patient use from two tertiary hospitals were sampled with sterile swabs using a standardized rolling technique. Samples were considered negative (not contaminated) if no colonies were present on the blood agar plate after an 18-hour incubation period. Samples were stratified by hospital and according to the frequency of intubation attempts (10 attempts per year) using the ${\chi}^2-test$ and Fisher exact test. Results: One or more species of bacteria were isolated from 4 (5.6%) handle tops, 20 (28.2%) handles with knurled surfaces, and 27 (18.2%) blades. No significant differences were found in microbial contamination levels on the handle tops and blades between the two hospitals and two areas according to the frequency of intubation attempts. However, significant differences were found between the two hospitals and two areas in the level of microbial contamination on the handles with knurled surfaces (p<0.05). Conclusions: Protocols and policies must be reviewed to standardize procedures to clean and disinfect laryngoscope blades and handles; handles should be re-designed to eliminate points of contact with the blade; and single-use, one-piece laryngoscopes should be introduced.

Development of the ZnS(Ag)/BC-408 phoswich detector for monitoring radioactive contamination inside pipes (배관 내부 방사능 오염도 측정용 ZnS(Ag)/BC-408 phoswich 검출기 개발)

  • Kim, Gye-Hong;Park, Chan-Hee;Jung, Chong-Hun;Lee, Kune-Woo;Seo, Bum-Kyoung
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.3
    • /
    • pp.123-128
    • /
    • 2006
  • A small radiation detection system is necessary for the direct characterization of alpha/beta-ray contamination inside pipes generated during the decommission of a nuclear facility. In this work, the new type phoswich detector consisting of the ZnS(Ag) and plastic scintillator for ${\alpha}/{\beta}$ simultaneous counting was designed as part of a development of a equipment capable of monitoring radiological contamination inside pipes. The optimum counting conditions in dimensions of scintillator and a detection system were experimentally confirmed and a performance of alpha/beta-ray discrimination was evaluated. As a result, optimum conditions of a detector suitable for monitoring radiological contamination inside pipes and a feasibility of application to pipe-inside were confirmed.

Radiological Accident and Acute Radiation Syndrome (방사선 사고와 급성 방사선 증후군)

  • Roh, Hyung-Keun
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.9 no.2
    • /
    • pp.39-48
    • /
    • 2011
  • In mass casualty situation due to radiological accidents, it is important to start aggressive management with rapid triage decisions. External contamination needs immediate decontamination and internal contamination should be treated with special expertise and equipment to prevent the rapid uptake of radionuclides by target organs. Acute radiation syndrome shows a sequence of events that varies with the severity of the exposure. More severe exposures generally lead to more rapid onset of symptoms and severe clinical findings. After the massive exposure, various systems of the body reflect their severe damages that can lead to death within hours or up to several months. The disease progression has classically been divided into four stages: prodromal, latent, manifest illness, and recovery or death. Three characteristic clusters of symptoms including the hematopoietic syndrome, the gastrointestinal syndrome and the cerebrovascular syndrome are all associated with the acute radiation syndrome. The standard medical management of the patients with a potentially survivable radiation exposure includes good medical, surgical and supportive measures. Specific treatment with cytokines and bone marrow transplantation should be considered. The management of internal contamination is much the same as the treatment of poisoning. The standard decontamination should be applied to reduce uptake, and the chelating agents can be administered to enhance the clearance of radioisotopes. Radioactive iodine ($^{131}I$) as one of the nuclear fission products can increase the incidence of thyroid cancer in children. Potential benefit of potassium iodide prophylaxis is greater especially in neonates, infants and small children.

  • PDF

In-situ Process Monitoring Data from 30-Paired Oxide-Nitride Dielectric Stack Deposition for 3D-NAND Memory Fabrication

  • Min Ho Kim;Hyun Ken Park;Sang Jeen Hong
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.4
    • /
    • pp.53-58
    • /
    • 2023
  • The storage capacity of 3D-NAND flash memory has been enhanced by the multi-layer dielectrics. The deposition process has become more challenging due to the tight process margin and the demand for accurate process control. To reduce product costs and ensure successful processes, process diagnosis techniques incorporating artificial intelligence (AI) have been adopted in semiconductor manufacturing. Recently there is a growing interest in process diagnosis, and numerous studies have been conducted in this field. For higher model accuracy, various process and sensor data are required, such as optical emission spectroscopy (OES), quadrupole mass spectrometer (QMS), and equipment control state. Among them, OES is usually used for plasma diagnostic. However, OES data can be distorted by viewport contamination, leading to misunderstandings in plasma diagnosis. This issue is particularly emphasized in multi-dielectric deposition processes, such as oxide and nitride (ON) stack. Thus, it is crucial to understand the potential misunderstandings related to OES data distortion due to viewport contamination. This paper explores the potential for misunderstanding OES data due to data distortion in the ON stack process. It suggests the possibility of excessively evaluating process drift through comparisons with a QMS. This understanding can be utilized to develop diagnostic models and identify the effects of viewport contamination in ON stack processes.

  • PDF

Hygienic Aspects of Campylobacter Enteritis (Campylobacter장염에 의한 식품위생학적인 고찰)

  • 이용욱;홍종해
    • Journal of Food Hygiene and Safety
    • /
    • v.1 no.1
    • /
    • pp.57-66
    • /
    • 1986
  • Campylobacter jejuni has been recognized as one of the causes of human gastroenteritis. The feces of a variety of reservoir animals contain c. jejuni as commensals in the intestinal tracts, and are fundamental source of contamination. The intestinal organisms contaminate carcasses, equipment tools hands of the processing line workers and air of the processing facility. Once the contamination happens in the slaughterhouses or the meat processing facilities, it is very difficult to keep the carcasses free from the infection of c. jejuni. Various disinfectants are effective in minimizing the number of Campylobacter infections in the processing facilities by washing contaminated carcasses, tools, and hands. Direct contact with infected animals has been incriminated in transmission of infection caused by C. jejuni. Freezing, cooling with dry air and gamma irradiation are an effective way for preserving the meat and eliminating the transmission, but broad and enforced studies are needed for the practical use.

  • PDF

Decontamination of Simulated Test Piece by Dry Ice Pellet Blasting (드라이아이스 펠렛 분사에 의한 모의 시편의 제염)

  • Shin Jin-Myeong;Park Jang-Jin;Yang Myung-Seung
    • Journal of environmental and Sanitary engineering
    • /
    • v.19 no.2
    • /
    • pp.30-36
    • /
    • 2004
  • Dry decontamination technique is required for maintaining nuclear material handling equipment contaminated with highly radioactive material in a hot cell. In order to determine the optimum blasting conditions of dry ice pellet blasting device, the basic experiments have been conducted on the simulated test specimens of four types of metals. The removal efficiency of test piece was evaluated by the XRF analysis and the change of the surface condition before and after blasting. The removal efficiency of cesium on loose contamination was 100% under blasting pressure; 3 kg/$cm^2$, blasting distance; 10 cm, blasting time: 10 sec. In case of fixed contamination, the removal efficiency of cesium was almost 96% under blasting pressure; 4kg/$cm^2$, blasting distance; 10 cm, blasting time; 30 sec.

Energy Efficiency & Sustainability - the Cleanliness Management Role of Components and System in Automotive and Hydraulics

  • Day, Mik;Hong, Jeong-Hee
    • Journal of Drive and Control
    • /
    • v.9 no.2
    • /
    • pp.46-53
    • /
    • 2012
  • This paper explains how eliminating contamination from the manufacturing processes will lead to better product quality and hence the need for reworking, a trouble free commissioning period and greatly improved production efficiency. All of these will reduce costs and energy usage. It will also ensure that the product is delivered to the customer in a condition that will ensure improved reliability and longer life, again reducing both energy and other operating costs. Correctly designing the contamination control measures will achieve and maintain the level of fluid cleanliness that is required by the end user. The filter is critical to cleanliness management and should be selected with the same degree of thought and consideration as for other major components. This paper explains the role that Cleanliness Management plays in the reducing the carbon footprint of systems and processes by making them perform more efficiently for longer periods. It also examines two differing ways of selecting filters to incorporate the features of newer designs, and shows how significant savings in the costs of ownership can be achieved using these approaches.