• 제목/요약/키워드: Equal heat flux

검색결과 18건 처리시간 0.019초

Experimental Investigation on Critical Heat Flux in Bilaterally Heated Annulus with equal heat flux on both sides

  • Miao Gui;Junliang Guo;Huanjun Kong;Pan Wu;Jianqiang Shan;Yujiao Peng
    • Nuclear Engineering and Technology
    • /
    • 제55권9호
    • /
    • pp.3313-3319
    • /
    • 2023
  • A phenomenological study on CHF in a bilaterally heated annulus with equal heat flux on both sides was experimentally performed. The working fluid of the present test was R-134a. Variation characteristics of CHF and transition of CHF occurrence location were investigated under different pressure, mass flux and quality conditions. With the increase of critical thermodynamic quality, it was found that CHF first occurred on the outer surface of the annulus, then simultaneously occurred on both sides, and finally occurred on the inner surface at relatively high critical quality. After the CHF location transitioned to the inner rod, the sharp fall of CHF in the limiting critical quality region was observed. The critical quality corresponding to the CHF location transition decreased with the increase of mass flux and pressure. Besides, CHF in tube, internally heated, externally heated and bilaterally heated annuli were compared under the same hydraulic diameter conditions. The present study is conducive to improving the understanding of complicated CHF mechanism in bilaterally heated annulus, enriching the experimental database, and providing evidence for developing accurate CHF mechanism model for annuli.

제주도 북부해역의 표면 열수지 해석 -1993년과 1994년 하계의 경우- (Surface Heat Budget of the Northern Sea of Cheju Island for June-August 1993 and 1994)

  • 김해동;양성기
    • 한국환경과학회지
    • /
    • 제4권3호
    • /
    • pp.197-206
    • /
    • 1995
  • Surface heat balance of the northern sea of Cheju Island for summer in 1993 and 1994 is analyzed using the observation data obtained by Marine Research Institute, Cheju National University. Each flux elements at the sea surface is derived from the marine meteorological reports with application of an aerodynamical bulk method for the turbulent heat fluxes, and empirical formulae for the long-wave radiation heat fluxes. The flux divergence of oceanic heat transport and the rate of heat storage in the ocean are estimated as residual. The features of the surface heat balance are mainly decided by the solar radiation flux and the latent heat flux for 199B. But the Bowen Ratios were large for 1993. This means that the sensible heat fluxes were nearly equal to the latent heat fluxes for 1993. In this period, mean flux divergence of oceanic heat transport is about 130 W/$m^2$.

  • PDF

마이크로핀관내 유동 양식과 응축 열전달 특성 연구 (Experiments on Condensation Heat Transfer Characteristics and Flow Regime Inside Microfin Tubes)

  • 한동혁;이규정
    • 설비공학논문집
    • /
    • 제13권7호
    • /
    • pp.602-611
    • /
    • 2001
  • Experiments on the condensation heat transfer characteristics inside a smooth and a microfin tube with R410A/R22 are performed in this study. The test tubes 7/9.52 mm in outside diameters and 3m in length are used. Varying the mass flux of the refrigerant and the condensation temperatures, the average heat transfer coefficients and pressure drop are investigated. Most flows in this study are in the annular and/or wavy flow regime. It is shown that the heat transfer is enhanced and the pressure drops are larger in the microfin tube than the smooth tube. From the heat transfer enhancement coefficients and the pressure drops, it is found that the high heat transfer enhancement factors are obtained in the range of small mass flux while the penalty factors are almost equal. Experiments results show that average heat transfer coefficients of R410A is larger than that of R22 and pressure drop of R410A is less than R22.

  • PDF

남극 세종기지에서의 지표 플럭스 관측: II. 2002-2003년 남반구 여름 기간의 열과 수증기의 난류 교환 (Surface Flux Measurements at King Sejong Station in West Antarctica: II. Turbulent exchanges of sensible heat and latent heat in the austral summer of 2002-2003)

  • 최태진;이방용;이희춘;김성중;홍성민
    • 지구물리
    • /
    • 제8권3호
    • /
    • pp.159-167
    • /
    • 2005
  • Turbulent fluxes of sensible heat and latent heat were analyzed at King Sejong station in the austral summer of 2002 (December) and 2003 (January and February). Monthly mean air temperatures of January and February (2.2oC) were similar to those averaged over 1988 to 2001. Precipitation was less in January and greater in February than those averaged over last 14 years. In December of 2002 and January, there was precipitation primarily when easterly wind blew usually. The frequency of snowfall was equal to or larger than that of rainfall. In the mean while, precipitation primarily in forms of rainfall occurred with westerly wind in February. In addition, while for easterly wind, temperature and humidity was low, temperature and humidity were high in case of westerly wind. Based on flux footprint, measured flux mainly came from within 300 m with maximum of 40 m upwind, indicating the insignificant role of the sea around the study site. Half-hourly downward short wave radiation amounted up to ∼ 1000 Wm-2 and net radiation ranged from -50 to 600 Wm-2. Half-hourly sensible heat flux was positive at daytime with maximum of ∼ 400 Wm-2, except the 27th and 28th in February of 2003 when it was negative all day despite of positive net radiation at short daytime. Latent heat flux was positive with maximum of ∼ 130 Wm-2. Depending on wind direction, the partitioning of net radiation into the sum of sensible heat flux and latent heat flux was larger than 0.8, indicating the strong source of the land surface for the atmospheric heating. The daytime averaged Bowen ratio (=sensible heat flux /latent heat flux) was significantly greater than 1, indicating that sensible heat flux was the main source to heat the atmosphere over the site.

  • PDF

마이크로 휜관낸 R410A의 응축열전달 특성에 관한 실험적 연구 (Experiments on Condensation Heat Transfer Characteristics Inside a Microfin Tube with R410A)

  • 한동혁;조영진;이규정;박심수
    • 대한기계학회논문집B
    • /
    • 제24권11호
    • /
    • pp.1470-1477
    • /
    • 2000
  • Due to the ozone depletion and global warming potentials, some refrigerants(CFx and HCFCs) have been rapidly substituted. R410A is considered as the alternative refrigerant of R22 for the air-conditioners used a home and in industry. Experiments on the condensation heat transfer characteristics inside a smooth or a micro-fin tube with R410A are performed in this study. The test tubes 7/9.52 mm in outer diameters and 3 m in length are used. Varying the mass flux of the refrigerant and the condensation temperatures, the average heat transfer coefficients and pressure drop are investigated. It is shown that the heat transfer is enhanced and the amount of pressure drops are larger in the microfin tube than the smooth tube. From the heat transfer enhancement coefficient and the pressure penalty factor, it is found that the high heat transfer enhancement coefficients are obtained in the range of small mass flux while the penalty factors are almost equal.

직렬 관군에서 지열수스케일의 파울링 영향에 관한연구 (A Study on the Fouling Effect of Geothermal Water Scale in In-line tube Bank)

  • 윤석범
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권2호
    • /
    • pp.131-139
    • /
    • 1999
  • An experimental study was conducted to investigate the fouling effects of geothermal water scale deposited onto a heating surface upon its forced convection heat transfer characteristics. Scales deposited onto the heating surfaces of heat exchangers seriously reduce the heat transfer perfor-mance and also increase the hydrodynamic drag. Accordingly fouling is an important problem in the design and operation of heat exchangers. The cylinders were settled in tandem with equal dis-tance between neighbouring cylinders and only the test cylinder was heated under the condition of constant heat flux. The Reynolds number was varied from 13000310 through 50003100. It is found that the heat transfer of the in-line tube banks greatly varies with the fouling of geothermal water scale especially its scale height. Further the local and average Nusselt numbers strongly depend upon the cylinder spacing and the Reynolds number.

  • PDF

강제대류 아냉각비등에서 급격한 기포발생점의 예측 (Prediction of the Onset of Significant Void in Forced-Convection Subcooled Boiling)

  • 이상천;남상철
    • 대한기계학회논문집
    • /
    • 제18권3호
    • /
    • pp.681-689
    • /
    • 1994
  • A model to predict the onset of significant void (OSV) in vertical flow between parallel plates has been developed. The model was compared to the experimental data of Whittle and Forgan (1967) and Dougherty et al. (1990), showing excellent agreement. The model was also compared with the Saha-Zuber(1974) correlation, which has been widely used in computer codes for nuclear safety analysis. The present theory is more conservative than this correlation, and further shows that, contrary to this correlation, the Stanton number is not solely related to the Peclet number. This may explain the large error margins required for the Saha-Zuber correlation, and also the scatter beyond the error margins specified by the authors. The steady-state OSV heat fluxes for equal and unequal heating cases between parallel plates were compared. The arithmetic mean of heat fluxes for unequal heating cases is less than the heat flux for equal heating cases. The result may imply that OSV is controlled by local thermal parameters rather than bulk parameters.

A Heuristic Application of Critical Power Ratio to Pressurized Water Reactor Core Design

  • Ahn, Seung-Hoon;Jeun, Gyoo-Dong
    • Nuclear Engineering and Technology
    • /
    • 제34권1호
    • /
    • pp.68-79
    • /
    • 2002
  • The approach for evaluating the critical heat flux (CHF) margin using the departure from nucleate boiling ratio (DNBR) concept has been widely applied to PWR core design, while DNBR in this approach does not indicate appropriately the CHF margin in terms of the attainable power margin-to-CHF against a reactor core condition. The CHF power margin must be calculated by increasing power until the minimum DNBR reaches a DNBR limit. The Critical Power Ratio (CPR), defined as the ratio of the predicted CHF power to the operating power, is considered more reasonable for indicating the CHF margin and can be calculated by a CPR orrelation based on the heat balance of a test bundle. This approach yields directly the CHF power margin, but the calculated CPR must be corrected to compensate for many local effects of the actual core, which are not considered in the CHF test and analysis. In this paper, correction of the calculated CPR is made so that it may become equal to the DNB overpower margin. Exemplary calculations showed that the correction tends to be increased as power distribution is more distorted, but are not unduly large.

원관내 맥동난류유동에서의 열전달 수치해석 (Numerical Analysis of Heat Transfer in Pulsating Turbulent Pipe Flow)

  • 박희용;이관수;김창기
    • 대한기계학회논문집
    • /
    • 제14권5호
    • /
    • pp.1282-1289
    • /
    • 1990
  • 본 연구에서는 원관내에서 동적으로 완전히 발달한 난류맥동유동에서 관벽에 서 균일한 열유속이 주어지는 경우에 대하여 난류모델로서 K-.epsilon. 2방정식 모델을 적용 하여 수학적인 모델을 세운 후 이를 수치적으로 해석하였다. 그 결과 시간평균 레이 놀즈수가 10000인 경우에 대하여 Strouhal수가 0.0005에서 0.05 그리고 맥동속도진폭 이 0.8이하인 맥동류에 대한 열전달 특성을 제시하였다.

Heat flux를 이용한 토양 표면 온도 예측 (Estimation of Soil Surface Temperature by Heat Flux in Soil)

  • 허승오;김원태;정강호;하상건
    • 한국토양비료학회지
    • /
    • 제37권3호
    • /
    • pp.131-135
    • /
    • 2004
  • 본 연구는 일반 기상 측정에서 에너지 수지를 구할 때 이용되는 지중열류 값과 토양 내 10 cm 깊이에서 측정한 토양온도를 활용하여 태양 복사에너지와 지표면 복사 에너지의 도달과 분배에 중요한 역할을 하는 토양표면의 온도를 예측하고자 수행하였다. 2003년 6월 10일부터 6월 24일까지 측정한 지중열류와 토양온도 그래프에서 토양온도나 지중열류는 주기성을 나타내며 일중 최저 지중열류와 최고 토양온도 사이에는 위상편차가 존재한다. 토심 5 cm에서 측정하여 시간별로 평균한 토양온도와 지중열류 사이에는 2시간의 시간지연이 존재하며 토양온도와 시 공간상에서의 지중열류는 정의 상관관계를 보였다. 이는 단위체적 당 열용량과 깊이에 따른 열량의 변화율이 태양에너지와 지표면 복사를 통한 지중열류에 비례한다는 것을 의미한다. 예측된 토양 표면온도는 시간별로 평균하였을 때 그 평균온도가 $20^{\circ}C$를 넘어 여름철의 기온을 반영하였으며 모양도 주기함수 형태를 보였다. 진폭은 $4.5^{\circ}C$로서 10 cm 깊이에서의 진폭인 $3.4^{\circ}C$보다 $1.1^{\circ}C$ 높았으며 최저온도가 나타난 시간은 토양표면의 경우는 오전 8시, 10 cm 깊이에서는 오전 9시였으며 최고온도가 나타난 시간은 토양표면은 16시, 10 cm 깊이는 19시이었다. 시간별로 평균하지 않았을 때의 최고와 최저온도는 각각 33.2, $16.5^{\circ}C$ 였으며, 토양표면온도 분포는 $15-20^{\circ}C$가 5.3%, $20-25^{\circ}C$가 65.6%, $25-30^{\circ}C$가 28.1%, $30-35^{\circ}C$가 1%로 대부분의 온도는 $20-25^{\circ}C$ 범위의 값을 나타냈다. 예측된 토양표면온도의 검증을 위해 토양표면 온도와 10 cm 깊이의 토양온도를 가지고 계산한 산술 평균과 토심 5 cm에서 측정한 토양온도를 비교하였다. 또한, 그 과정을 통해 얻어진 추정회귀모형은 P값이 0.001보다 작아 유의성이 인정 되었다. 회귀모형의 결정계수는 0.968이었고 표준오차는 0.38로 예측된 토양표면온도는 추정 회귀모형에 의해 실제 값에 가깝게 추정할 수 있을 것이다.