• Title/Summary/Keyword: Epoxy composites

Search Result 1,050, Processing Time 0.024 seconds

Tensile Properties of CERP Fabric/Unidirectional Composites under Cryogenic Environment (극저온 환경에서 탄소섬유강화 직조/일방향 복합재료의 인장 물성 측정)

  • 김명곤;김철웅;강상국;김천곤;홍창선
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2003.10a
    • /
    • pp.115-118
    • /
    • 2003
  • This research aims to measure mechanical tensile properties of CFRP composites for cryogenic tank material. Through the cryogenic chamber, tensile tests are peformed under cryogenic temperature for graphite/epoxy fabric specimen aged at $-150^{\circ}C$ for 30hrs with load and graphite/epoxy unidirectional specimen 3-cycled from RT to $-100^{\circ}C$ with load. For graphite/epoxy fabric specimen, tensile modulus showed to increase after aging at cryogenic temperature(CT) while to decrease after aging at room temperature(RT) and tensile strength is more decreased after CT-aged than at RT-aged. For graphite/epoxy unidirectional specimen, tensile modulus was almost not changed after 3-cycling but strength showed the trend of decrease as increase the number of cycling.

  • PDF

Evaluation of Mixed-mode Interlaminar Fracture Toughness of Carbon Fabric/Epoxy Composites for Tilting Train Carbody (틸팅차량용 탄소섬유직물/에폭시 복합재의 혼합모우드 층간파괴인성 평가)

  • Yun, Seong-Ho;Heo, Gwang-Su;O, Jin-O;Lee, Sang-Jin;Jeong, Jong-Cheol;Kim, Jeong-Seok
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.11a
    • /
    • pp.256-259
    • /
    • 2005
  • Mixed-mode interlaminar fracture toughness of carbon fabric/epoxy composites, which are applicable to tilting train carbody, was evaluated through the MMB (Mixed-mode bending) test. Specimens were made of CF3327 plain woven fabric with epoxy and a starter delamination at one end was made by inserting Teflon film with the thickness of 12.5 μ m. Mixed-mode interlaminar fracture test was conducted for 6 types of specimens with the mode II ratio of 20 ,35, 50, 65, 80, 90%. Also crack propagating behaviors and fractured surfaces were examined through an optical travelling scope and a scanning electron microscope, respectively.

  • PDF

Thermal and Mechanical Properties of Epoxy/Micro- and Nano- Mixed Silica Composites for Insulation Materials of Heavy Electric Equipment

  • Park, Jae-Jun;Yoon, Ki-Geun;Lee, Jae-Young
    • Transactions on Electrical and Electronic Materials
    • /
    • v.12 no.3
    • /
    • pp.98-101
    • /
    • 2011
  • A 10 nm nano-silica was introduced to a conventional 3 ${\mu}M$ micro-silica composite to develop an eco-friendly new electric insulation material for heavy electric equipment. Thermal and mechanical properties, such as glass transition temperature (Tg), dynamic mechanical analysis, tensile and flexural strength, were studied. The mechanical results were estimated by comparing scale and shape parameters in Weibull statistical analysis. The thermal and mechanical properties of conventional epoxy/micro-silica composite were improved by the addition of nano-silica. This was due to the increment of the compaction via the even dispersion of the nano-silica among the micro-silica particles.

Electrical Insulation Breakdown Strength in Epoxy/Spherical Alumina Composites for HV Insulation

  • Park, Jae-Jun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.2
    • /
    • pp.105-109
    • /
    • 2013
  • In order to develop high voltage (HV) insulation materials, epoxy/spherical alumina composites with two different particle sizes (in ${\mu}m$) were prepared and a dynamic mechanical analysis (DMA) and electrical insulation breakdown strength test were carried out in sphere-sphere electrodes and the data were estimated using Weibull statistical analysis. Alumina content varied from 50 to 70 wt%. The electrical insulation breakdown strength for epoxy/alumina (50 wt%) was 44.0 kV/1 mm and this value decreased with increasing alumina content. The effects of insulation thickness and alumina particle size on the insulation breakdown strength were also studied. The insulation thickness varied from 1 mm to 3 mm, and the particle sizes were 7.3 or $40.3{\mu}m$.

A Study on the Dielectric Properties of Epoxy Composites due to Temperature Variation (온도변화에 따른 에폭시 복합체의 유전특성에 관한 연구)

  • 김상걸;송봉철;정동회;이호식;이원재;이준웅
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.148-151
    • /
    • 2000
  • In this paper, the dielectric properties of epoxy composites used for transformers are studied. The dielectric permittivity and loss of specimen are measured at the temperature range of 20[$^{\circ}C$]~150[$^{\circ}C$] about frequency 30[Hz], 1[kHZ] and 30[kHz] respectively from a series of experiments. Consequently, observed higher values of dielectric permittivity and loss in filled epoxy are attributed to Maxwell-Wagner Polarization effect. Also, glass transition temperature was shifted to higher temperature and value of dielectric permittivity and loss were decreased due to 2nd curing.

  • PDF

Nondestructive Microfailure and Interfacial Evaluation of Plasma-Treated PBO and Kevlar Fibers/Epoxy Composites using Micromechanical Test and Acoustic Emission (Micromechanical 시험법과 음향방출을 이용한 플라즈마 처리된 PBO와 Kevlar 섬유강화 Epoxy 복합재료의 비파괴적 파단특성 및 계면물성 평가)

  • 박종만;김대식;김성룡
    • Composites Research
    • /
    • v.16 no.4
    • /
    • pp.74-79
    • /
    • 2003
  • Comparison of interfacial properties and microfailure mechanisms of oxygen-plasma treated poly(p-phenylene-2,6-benzobisoxazole(PBO. Zylon) and poly(p-phenylene terephthalamide)(PPTA, Kevlar) fibers/ epoxy composites were investigated using micromechanical technique and nondestructive acoustic emission(AE). Interfacial shear strength(IFSS) and work of adhesion, Wa of PBO or Kevlar fibers/epoxy composites increased by oxygen-plasma treatment. Plasma-treated Kevlar fiber shooed the maximum critical surface tension and polar term, whereas the untreated PBO fiber showed the minimum value. Microfibril fracture pattern of plasma-treated Kevlar fiber appeared obviously. Based on the propagation of microfibril failure toward core region. the number of AE events for plasma-treated PBO and Kevlar fibers increased significantly. The results oi nondestructive AE were consistent well with microfailure modes by optical observation in microdroplet and two-fiber composites tests.

A Study on Improvement of Thermal and Adhesion Properties of Stone/Wood Composites for Stone Bed using CNT-epoxy Adhesive (CNT/Epoxy 접착제를 이용한 돌침대용 석재/목재 복합재의 열적특성 및 접착특성 개선 연구)

  • Kim, Jong-Hyun;Shin, Pyeong-Su;Kwon, Dong-Jun;Moon, Sun-Ok;Park, Joung-Man
    • Composites Research
    • /
    • v.29 no.5
    • /
    • pp.276-281
    • /
    • 2016
  • Improvement of the thermal and adhesion properties of stone/wood composites was studied. Tensile test was performed for wood and stone to know the basic mechanical properties. Real-time temperature of stone and wood was measured when stone and wood was heated. To compare thermal transfer properties of stone/wood composites, two types of specimens were tested: one was stone upper whereas another was wood upper. Real time temperature measurement and lap shear test were performed to know thermal and adhesion properties by using CNT-epoxy adhesive in which CNT was dispersed in epoxy adhesive uniformly. The thermal transfer property was better for the wood upper case than stone upper case. Adding CNT improved the heat transfer as well as mechanical properties including lap shear strength.

Fiber Surfaces and Interlaminar Shear Strengths of Electrolytic Ni-plated Carbon Fiber/Epoxy Resin Composites (전해 니켈도금 처리에 따른 탄소섬유/에폭시 수지 복합재료의 섬유표면 및 기계적 계면전단 강도)

  • 박수진;장유신;이재락;김진석
    • Polymer(Korea)
    • /
    • v.24 no.5
    • /
    • pp.721-727
    • /
    • 2000
  • The electrolytic plating of a metallic nickel on carbon fiber surfaces was carried out to improve mechanical interfacial properties of carbon fiber/epoxy resin composites. The surface characteristics of carbon fibers and the mechanical interfacial properties of final composites were characterized by X-ray photoelectron spectroscopy (XPS) and interlaminar shear strength (ILSS), respectively. It was found that the electrolytic Ni-plating conditions significantly affected the degree of adhesion at interfaces between carbon fibers and epoxy resin matrix in a composite system. Especially, the increase of O,$_{1s}$/$C_{1s}$ ratio, production of NiO groups, and formation of metallic nickel on the nickel-plated carbon fiber surfaces led to an increase of the ILSS of the composites. Also, the ILSS of the composites was greatly correlated with the $O_{1s}$/$C_{1s}$ ratio of the carbon fibers treated in this work.is work.

  • PDF

Thermal and Mechanical Properties of Short Fiber-Reinforced Epoxy Composites (단섬유 강화 에폭시 복합재료의 열적/기계적 특성)

  • Huang, Guang-Chun;Lee, Chung-Hee;Lee, Jong-Keun
    • Polymer(Korea)
    • /
    • v.33 no.6
    • /
    • pp.530-536
    • /
    • 2009
  • A cycloaliphatic epoxy/acidic anhydride system incorporating short carbon fibers (SCF) and short glass fibers (SGF) was fabricated and thermal/mechanical properties were characterized. At low filler content both SCF- and SGF-reinforced composites showed a similar decrease in coefficient of thermal expansion (CTE), measured by a thermomechanical analyzer, with increasing loadings, above which SCF became more effective than SGF at reducing the CTE. Experimental CTE data for the SCF-reinforced composites is best described by the rule of mixtures at lower SCF contents and by the Craft-Christensen model at higher SCF contents. Storage modulus (E') at $30^{\circ}C$ and $180^{\circ}C$ was greatly enhanced for short fiber-filled composites compared to unfilled specimens, Scanning electron microscopy of the fracture surfaces indicated that the decreased CTE and the increased E' of the short fiber-reinforced composites resulted from good interfacial adhesion between the fibers and epoxy matrix.

Effect of Silane Coupling Agent on the Interfacial Adhesion and Mechanical Properties of Polyketone Fiber Reinforced Epoxy Composites (실란커플링제 처리가 폴리케톤섬유/에폭시 복합재료의 계면접착성 및 물성에 미치는 영향)

  • Jo, Hani;Yang, Jee-Woo;Lim, Hyeon Soo;Oh, Woo Jin;Lee, Seung Goo
    • Textile Coloration and Finishing
    • /
    • v.29 no.2
    • /
    • pp.77-85
    • /
    • 2017
  • The interfacial adhesion between fiber and matrix affects the physical properties of fiber reinforced composites. In this study, 3-(Methacryloyloxy)propyltrimethoxy silane(MPS) coupling agent was used to increase the interfacial adhesion between polyketone fiber and epoxy resin. The change of surface chemical composition of polyketone fiber treated with MPS was analyzed using a FTIR-ATR. The interfacial bonding between fiber and resin increased with silane coupling agent largely. Consequently, interfacial shear strength(IFSS) was enhanced with increasing concentration of MPS coupling agent and thus, the physical properties of the composites such as flexural properties and dynamic mechanical properties were changed. Flexural strength and modulus increased when the MPS concentration was higher than 0.5wt%. The dynamic storage modulus of Polyketone/Epoxy composites treated with MPS was higher than that of the untreated one. When the MPS concentration of 3wt%, the highest storage modulus was obtained.