• 제목/요약/키워드: Epoxy Resins

Search Result 262, Processing Time 0.03 seconds

Analysis of the Physical Properties of the Conductive Paste according to the Type of Binder Resin and Simulation of Mechanical Properties according to Ag Flake Volume Fraction (바인더 수지 종류에 따른 도전성 페이스트의 물성 분석 및 Ag flake 부피 분율에 따른 기계적 특성 시뮬레이션 연구)

  • Sim, Ji-Hyun;Yun, Hyeon-Seong;Yu, Seong-Hun;Park, Jong-Su;Jeon, Seong-Min;Bae, Jin-Seok
    • Composites Research
    • /
    • v.35 no.2
    • /
    • pp.69-74
    • /
    • 2022
  • In this study, the conductive paste used in a wide range such as wiring in the electronic packaging field, the automobile industry, and electronic products is manufactured under various process conditions due to the simplicity of the process, and then the thermal, mechanical, and electrical characteristics are analyzed and simulation studies are conducted to optimize the process. to establish the conditions of the conductive paste manufacturing process. First, a conductive paste was prepared by setting various types of binder resin, an essential component of the conductive paste, and characteristics such as thermal conductivity, tensile strength, and elongation were analyzed. Among the binder resins, the conductive paste applied with a flexible epoxy material had the best physical properties, and a simulation study was conducted based on the physical property data base of the conductive face. As a result of the simulation, the best physical properties were exhibited when the Ag flake volume fraction was 60%.

Resin Optimization for Manufacturing CFRP Hydrant Tanks for Fire Trucks (소방차용 CFRP 소화전 탱크제조를 위한 수지 최적화 연구)

  • Huh, Mong Young;Choi, Moon Woo;Yun, Seok Il
    • Composites Research
    • /
    • v.35 no.4
    • /
    • pp.255-260
    • /
    • 2022
  • Lightweight hydrant tanks increase the amount of water that can be carried by fire trucks, resulting in longer water spray times during the initial firefighting process, which can minimize human and property damages. In this study, the applicability of carbon-fiber-reinforced polymer (CFRP) composites as a material for lightweight hydrant tanks was investigated. In particular, the resin for manufacturing CFRP hydrant tanks must meet various requirements, such as excellent mechanical properties, formability, and dimensional stability. In order to identify a resin that satisfies these conditions, five commercially available resins, including epoxy(KFR-120V), unsaturated polyesters(G-650, HG-3689BT, LSP8020), vinyl ester(KRF-1031) were selected as candidates, and their characteristics were analyzed to investigate the suitability for manufacturing a CFRP hydrant tank. Based on the analyses, KRF-1031 exhibited the most suitable properties for hydrant tanks. Particularly, CFRP with KRF-1031 exhibited successful results for thermal stability and elution tests.

Experimental Study on Thermal and Mechanical Characteristics of Two Resin Composites Using the Co-Curing Process (동시 경화 제작기법을 적용한 이종 수지 복합재의 열적/기계적 특성에 관한 실험적 연구)

  • Yoon, Jin-Young;Choi, Jiduck;Park, Cheolyong;Kim, Younggyu
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.23 no.5
    • /
    • pp.475-484
    • /
    • 2020
  • Individual curing process of each layer in two resin composites can be caused the separation between two layers. In this study, co-curing process for two resin composites is suggested to improve the inter-layer bonding. Glass fiber reinforced composites with phenolic and epoxy resins were manufactured by co-curing process, and several types of glass/phenolic composites were considered to confirm the application on two resin composites. Experiments for smoke resistance, scratch resistance and flexural strength were carried out to verify requirements corresponding to thermal and mechanical environments. It was validated that two resin composites with phenolic resin impregnated prepreg exhibits good thermal and mechanical characteristics, and it can serve as highly effective composite structures in aerospace and many industry areas.

Reliability Assessment of Reinforced Concrete Beams Strengthened by CFRP Laminates (CFRP 적층판으로 보강된 철근콘크리트보의 신뢰성평가)

  • 조효남;최영민
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1994.10a
    • /
    • pp.160-166
    • /
    • 1994
  • In general, the problems of strengthening and repairing of deteriorated or damaged reinforced concrete members are usually worked out in situ by externally bounding steel plates using epoxy resins, which has been recognized to be one of effective and convenient methods. But the disadvantages of strengthening/repairing concrete members with externally bonded steel plates include ; (a) deterioration of the bond at the steel-concrete interface caused by the corrosion of steel ; (b) difficulty in manipulating the plate at the construction site ; (c) improper formation of joints, due to the limited delivery lengths of the steel plates ; and etc. Therefore these difficulties eventually have led to the concept of replacing the steel plates by fiber-reinforced composite sheets which are characterized by their light weight, extremely high stiffness, excellent fatigue properties, and outstanding corrosion resistance. In the paper, for the reliability assessment of reinforced concrete beams externally strengthened by carbon fiber plastic(CFRP) laminates, an attempt is made to suggest a limit state model based on the strain compatibility method and the concept of fracture mechanics. And the reliability of the proposed models is evaluated by using the AFOSM method. The load carrying capacity of the deteriorated and/or damaged RC beams is considerably increased. Thus, it may be stated that the post-strengthening of concrete beams with externally bonded CFRP materials may be one of very effective way of increasing the load carrying capacity and stiffeness characteristics of existing structures.

  • PDF

Experimental Study on the Flexural Behaviour of CFRP-bar NSM R.C Beams depending on Adhesive and Anchorage (접착재 종류와 정착구 유무에 따른 탄소막대 매립보강 RC보의 휨 거동에 관한 실험적 연구)

  • Kim, Sung-Won;Lee, Hyung-Geun;Yeo, Hwan-Jun;Park, Sung-Moo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.14 no.4
    • /
    • pp.73-80
    • /
    • 2014
  • For the last decade many bridges and buildings have experienced flexural strengthening with the fiber reinforced polymer(FRP) bonding system, demands for increasing heavy traffic loads and the changing of the code application. Of the many strengthening systems, NSM(near surface mounted) system with FRP has become attractive and popular way of strengthening for the existed RC structures and many studies and applications of this technique have significantly increased all over the world. Meanwhile, polymer mortar that contains much of the same ingredients as cement but includes the addition of certain polymer resins for enhancing desired physical properties, has been used as an alternative adhesive. This paper focuses on flexural behaviour of CFRP-bar NSM system with variables such as kinds of adhesive, anchorage, sectional aspect ratio. Based on the test results and test-to-predicted ratio, this paper provides researchers and practical engineers a fundamental knowledge and intuition.

Development of Composite Fly Ash Pipe (비회 운송용 유리섬유 복합관 개발)

  • Jeong, Gyu-Sang;Won, Sam-Yong;Moon, Jin-Sung
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.33-36
    • /
    • 2007
  • The majority of fly ash pipes in thermal power stations use steel pipes. This makes frequent replacement inevitable due to severe abrasion near the hot and curved section of pipes. Recently, there have been efforts to prevent this abrasion with lining techniques using ceramic or basalt on the inner wall of the pipe. This study uses composite and anti-wear material to maximize the anti-abrasion effects on the hot section of the pipe. The thickness of the abrasion layer was determined by the abrasion ratio of material found through the experiment; the thickness of the reinforcement layer was determined by micromechanics. Experiments were conducted on epoxy resins to test for heat and abrasion. Anti-abrasion test using particle impingement was intended to recreate realistic conditions when abrasion occurs within the hot section of an actual pipe. This study analyzes the abrasion ratio obtained from both the specimen experiment and from on-site measurement and provides evidence that a combination of composites and anti-wear agent can be used to create a fly ash pipe that is lower in costs and higher in quality than what is used currently.

  • PDF

Repair and Strengthening Methods for Concrete Structures using Sprayed Fiber Reinforced Polymers - Strengthening performance of Reinforced Concrete Shear Columns - (Sprayed FRP 공법에 의한 콘크리트 구조물의 보수.보강법 개발에 관한 연구 - 철근콘크리트 전단기둥의 보강성능 평가 -)

  • Lee, Kang-Seok;Byeon, In-Hee;Son, Young-Sun;Lee, Moon-Sung;Li, Cheng-Hao;Lee, Li-Hyung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.137-140
    • /
    • 2006
  • In this study, a seismic performance of reinforced concrete columns strengthened by a sprayed fiber reinforced polymer (SFRP) is investigated. For this purpose, six column specimens approximately scaled into 2/3, are designed and tested under a constant axial load, 10% of the nominal axial strength of column, and pseudo-static reversed cyclic lateral loading system. Four specimens are strengthened by Sprayed FRP using different combinations of short fibers (carbon or glass fiber) and resins (epoxy or vinyl esther). For comparison, the test investigated in this study also includes a specimen strengthened using carbon fiber reinforced polymer (CFRP), and also a control specimen without strengthening. The results revealed that specimens strengthened using SFRP showed a improved structure behavior, compared to control specimen, in terms of strength, ductility, lateral drift capacity, and energy-absorbtion capacity. In addition, compared to the specimen strengthened using CFRP, Sprayed FRP-strengthened specimens reasonably showed a equivalent seismic performance.

  • PDF

Changes of serum immunoglobulin in the subacute oral administration of bisphenol A

  • Byun, Jung-A;Pyo, Myoung-Yun
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.296.1-296.1
    • /
    • 2002
  • Bisphenol A(BPA). a monomer used in the manufacturing epoxy resins and polycarbonates. has been reported to induce estrogenic activity, it has been considered as an environmental endocrine disruptor. But the immunomodulatory effects of BPA exposure have not been systemically evaluated. We investigated whether BPA effects on the ability of immunoglobulin(lg) production of mice. To initiate investigation of BPA-induced alterations of the immune system. BPA at dose of 100. 500,1000 mg/kg b.w./day with or without OVA-antigen for 30 days were orally administered to female ICR mice. Mice were sacrificed and serum was colleted on day 2 following administration of BPA for 30days. Total lgG1. total lgG2a. total lgE. OVA-specific lgG1. OVA-specific lgG2a. and OVA-specific lgE in serum were detetmined and compared with those of non-treated mice. In the groups of BPA with OVA antigen, total 1gG1, total lgG2a, total lgE. OVA-specific lgG1 and OVA-specific lgG2a were significantly decreased at dose of 500mg/kg/day. However, in mice treated with BPA alone, total lgG1, and lgG2 were not much altered and total lgE was significantly increased at dose of 1000mg/kg/day. These results demonstrated the BPA modulates the production of immunoglobulin.

  • PDF

Experimental and numerical study of the behavior of fiber reinforced concrete beams with nano-graphene oxide and strengthening CFRP sheets

  • Mohammad Reza Halvaeyfar;Ehsanollah Zeighami;S. Mohammad Mirhosseini;Ali Hassani Joshaghani
    • Structural Engineering and Mechanics
    • /
    • v.87 no.4
    • /
    • pp.375-389
    • /
    • 2023
  • In many fiber concrete beams with Carbon Fiber Reinforced Polymer (CFRP), debonding occurs between the carbon sheets and the concrete due to the low strength of the bonding resin. A total of 42 fiber concrete beams with a cross-section of 10×10 cm with a span length of 50 cm are fabricated and retrofitted with CFRP and subjected to a 4-point bending test. Graphene Oxide (GO) at 1, 2, and 3 wt% of the resin is used to improve the mechanical properties of the bonding resins, and the effect of length, width, and the number of layers of CFRP and resin material are investigated. The crack pattern, failure mode, and stress-strain curve are analyzed and compared in each case. The results showed that adding GO to polyamine resin could improve the bonding between the resin and the fiber concrete beam. Furthermore, the optimum amount of nanomaterials is equal to 2% by the weight of the resin. Using 2% nanomaterials showed that by increasing the length, width, and number of layers, the bearing and stiffness of fiber concrete beams increased significantly.

A Study on the Thermo-mechanical Characteristics and Adhesion Reliability of Anisotropic Conductive Films Depend on the Curing Methods of Epoxy Resins (에폭시 레진의 경화방법에 따른 이방성 전도필름의 접합신뢰성 및 열적기계적 특성 변화)

  • Gil, Man-Seok;Seo, Kyoung-Won;Kim, Jae-Han;Lee, Jong-Won;Jang, Eun-Hee;Jeong, Do-Yeon;Kim, Su-Ja;Kim, Jeong-Soo
    • Polymer(Korea)
    • /
    • v.34 no.3
    • /
    • pp.191-197
    • /
    • 2010
  • To improve the curing method of anisotropic conductive film (ACF) at low temperature, it was studied to replace the thermal latent curing agent of imidazole compounds by the curing agent of cationically initiating type. Thermo-mechanical properties such as glass transition temperature, storage modulus, and coefficient of thermal expansion were investigated for the analysis of curing behavior. The reliability of ACF were observed in thermal cycle and high temperature-high humidity test. ACF using cationic initiator showed faster curing, lower CTE, and higher $T_g$ than the case of using imidazole curing agent, which is important for the high temperature stability. Furthermore, ACF using cationic initiator maintained a stable contact resistance in reliability test, although it was cured at low temperature and fast rate. With these results, it was confirmed that the curing method of epoxy had great effect on thermo-mechanical properties and reliability of ACF.