• Title/Summary/Keyword: EoI

Search Result 142, Processing Time 0.022 seconds

Ethylene oxide에 폭로에 의해 형성된 헤모글로빈 adduct의 분석에 관한 연구

  • An, Hye-Sil;Sin, Ho-Sang;Lee, Jin-Heon
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.11a
    • /
    • pp.150-153
    • /
    • 2005
  • A gas chromatography/electron impact mass spectrometric assay method was developed for the determination of Hb-adduct, 2-(hydroxyethyl)valine (HEVal), of ethylene oxide(EO). Globin was separated from hemoglobin by acid iso-propanol and ethyl acetate, then HEVal was isolated as PFPITH-HEVal by Edman degradation. PFPITH-HEVal was silylated with N-methyl-N-(tert-butyl-dimethylsilyl)trifluoroacetamide(MTBDMSTFA)-NH4I (1000:4) under catalysis of dithioerythritol. The detection limit of the assay was 5.8 pmol/g based upon assayed hemoglobin of 0.1g. Two groups of mice were exposed to EO for 0.5 and 1.0 hr/day, respectively at 400ppm during 4 weeks. As the result, the adduct levels increased according to the exposure time with the linearity of 0.7011 and 0.8914, respectively, HEVal was very valuable as biomarker for the exposure of EO. In human, HEVal was analyzed until 8.33 pmol/mg.

  • PDF

Deposition of Heavy Metal Oxide Glass Thin Films by R.F. Magnetron Sputtering (스퍼터링 방법을 이용한 중금속 산화물 유리 박막의 증착)

  • Kim, Woong-Kwern;Heo, Jong;Je, Jung-Ho
    • Journal of the Korean Ceramic Society
    • /
    • v.32 no.6
    • /
    • pp.669-676
    • /
    • 1995
  • In this study, EO glass films were deposited by R.F. magnetron sputtering using EO glass target. The glass formation of the EO film was greatly dependent on the substrate temperature and the crystallization started at approximately 28$0^{\circ}C$. As the temperature of the substrate or the oxygen content in the sputtering gas increased, UV/VIS/NIR absorption edge moved toward longer wavelength. A wave guiding phenomenon was observed from the prism-coupler experiment and a fluorescence of 1.06${\mu}{\textrm}{m}$ originated from 4Fe3/2longrightarrow4I11/2 transition of Nd3+ was detected from the film containing Nd3+ ions.

  • PDF

EO Performances for Ion-beam Aligned TN-LCD on a DLC Thin Film Layer

  • Jo, Yong-Min;Hwang, Jeoung-Yeon;Seo, Dae-Shik;Lee, Sang-Keuk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.04b
    • /
    • pp.118-120
    • /
    • 2002
  • Electro-optical (EO) characteristics of the ion beam (IB) aligned twisted nematic (TN)-liquid crystal display (LCD) with oblique ion beam exposure on the diamond-like carbon (DLC) thin film surface were studied. An excellent voltage-transmittance (V-T) curve of the ion beam aligned IN-LCD was observed with oblique ion beam exposure on the DLC thin film surface for I min. Also, a faster response time for the ion beam aligned TN-LCD with oblique ion beam exposure on the DLC thin film surface for 1 min can be achieved.

  • PDF

Automatic Registration between EO and IR Images of KOMPSAT-3A Using Block-based Image Matching

  • Kang, Hyungseok
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.4
    • /
    • pp.545-555
    • /
    • 2020
  • This paper focuses on automatic image registration between EO (Electro-Optical) and IR (InfraRed) satellite images with different spectral properties using block-based approach and simple preprocessing technique to enhance the performance of feature matching. If unpreprocessed EO and IR images from Kompsat-3A satellite were applied to local feature matching algorithms(Scale Invariant Feature Transform, Speed-Up Robust Feature, etc.), image registration algorithm generally failed because of few detected feature points or mismatched pairs despite of many detected feature points. In this paper, we proposed a new image registration method which improved the performance of feature matching with block-based registration process on 9-divided image and pre-processing technique based on adaptive histogram equalization. The proposed method showed better performance than without our proposed technique on visual inspection and I-RMSE. This study can be used for automatic image registration between various images acquired from different sensors.

Accessory Respiratory Muscle Activation during Chest Expansion Exercise using Elastic Bands in Children with Cerebral Palsy

  • Shin, Seung-Oh;Kim, Nan-Soo
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.11 no.3
    • /
    • pp.119-124
    • /
    • 2016
  • PURPOSE: The aim of this study was to evaluate activation of accessory respiratory muscles using electromyography during chest expansion upper extremity flexion, abduction, and external rotation exercises with an elastic band in children with cerebral palsy. METHODS: The subjects were 10 children with cerebral palsy. The inclusion criterion for participation was a Gross Motor Function Classification System level of I to III. The subjects were instructed to perform upper extremity flexion, abduction, and external rotation exercises with inspiration, and extension, adduction, and internal rotation exercises with expiration while seated on a chair without a backrest. PM (Pectoralis major), SCM (sternocleidomastoid), RA (rectus abdominis), and EO (external oblique) muscle activities were measured using electromyography. RESULTS: All tested muscles showed a statistically significant increase in activity after elastic band exercise. There were significant differences in PM, SCM, RA, and EO results after chest expansion exercise using elastic band. SCM showed the largest increase in activity after use of elastic bands, at $52.37{\pm}45.88$%, followed by the RA ($50.56{\pm}79.31$), EO ($35.42{\pm}35.45$), and PM ($31.72{\pm}25.64$). The increase in the SCM was greatest, followed by increases in the RA, EO, and PM CONCLUSION: These finding suggest that activity of accessory respiratory muscles increases with use of elastic bands during chest expansion exercise in cerebral palsy.

Effects of Shoulder Abduction in Opposite Directions on EMG Activity in the Abdominal Muscles during Single Leg Raising in the Supine Position on the Foam Roller in Healthy Subjects

  • Yun, Sung-Joon;Kim, Moon-Hwan
    • The Journal of Korean Physical Therapy
    • /
    • v.27 no.4
    • /
    • pp.270-274
    • /
    • 2015
  • Purpose: The purpose of this study was to examine the electromyographic (EMG) activity of the abdominal muscles and to compare the activity ratios of the bilateral rectus abdominis (RA) to oblique abdominal muscles during shoulder abduction in opposite directions with single leg raising (SLR) performed in the supine position on a foam roller. Methods: Fifteen healthy subjects were recruited to the study. Each subject lay on the foam roller and performed left single leg raising with right or left shoulder $90^{\circ}$ abduction (Abd); performed in a random order. Surface EMG recordings of selected abdominal muscles (i.e., the RA, external oblique abdominis [EO], internal oblique abdominis [IO], and transverse abdominis [TrA]) were normalized to maximum voluntary isometric contraction. EO/RA and IO and TrA/RA ratios were determined with surface EMG. Data were analyzed by Independent t-test. The statistical significance level was p<0.05. Results: The results were as follows: (1) the right RA, left EO, and right IO and TrA muscle activities increased significantly at the left SLR with left Abd compared to the left SLR with right Abd (p<0.05); and (2) the ratio of right EO/RA activity increased significantly at the left SLR with right Abd compared to left Abd (p<0.05). Conclusion: These findings suggest that left SLR with left Abd on a foam roller is an appropriate exercise for activation of specific oblique abdominal muscles.

AN EXPERIMENTAL STUDY ON THE FREEZE-DRIED BONE OF MAXILLA AND MANDIBLE IN KOREANS ;I. A microbiologic study of the sterility on the fresh-frozen and freeze-dried bone of human (동결 건조한 한국인 상하악골에 대한 실험적 연구;I. 단순냉동 및 냉동 건조된 동종골의 멸균에 관한 실험적 연구)

  • Um, In-Woong
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.13 no.4
    • /
    • pp.405-411
    • /
    • 1991
  • To determine the sterility of the prepared allogeneic bone of the human, culture of the allografts prior to implantation was performed on fresh-frozen and freeze-dried bone. Before the use of allografts to the patients, it must be confirmed about the sterility, cellular cytotoxicity, immune reaction, and osteoinductive potential as a biomaterials. Oral and maxillofacial surgeons demand for allograft bone will be increased in the future. Wonkwang Bone Bank attempted to meet this demand, has performed series of experimental study on the allograft bone of the Koreans to evaluate the physical and chemical suitability of the bone since the surgeons applications will have broadened from benign cystic lesions to fracture malunions and non-unions, large segmental defects, and whole-bone allorgrafts after tumor surgery. The results obtained were as follows: 1. Freeze-drying(FD) only shoed some bactericidal effects of the normal and osteo bone but in cases of performing EO gas sterilization, the FD effects was not clear. 2. The fact that FD has little effect than the EO gas sterilization on normal bone postulated that the presence of microbiota may be due to an operation and bone processing procedure. 3. FD and EO gas sterilization had a remarkable effect on the osteo bone. 4. The sterilization effect were EO gas, Freeze-drying, Fresh-Frozen with descending order. But all sterilization method were not complete to preserve and implant allograft bone. We are now performing further continuous study on the radiation and chemical sterilization procedure to make safe and complete allograft bone.

  • PDF

Technical Trends on Low-Altitude Drone Detection Technology for Countering Illegal Drones (불법 드론 대응을 위한 저고도 드론 탐지 기술 동향)

  • Lee, I.J.;Choi, S.H.;Joo, I.O.;Jeon, J.W.;Cha, J.H.;Ahn, J.Y.
    • Electronics and Telecommunications Trends
    • /
    • v.37 no.1
    • /
    • pp.10-20
    • /
    • 2022
  • A drone without attaching guns or bombs can be a dangerous weapon, since its motor speed is greater than 3000 rpm, which is similar to that of a mower powered by a LiPo battery. The anti-drone system is the only means of detecting and neutralizing drone attacks. Many defense companies around the world provide solutions using various types of equipment (for example, radar, cameras, jamming guns, and net guns). ETRI has also developed a Low-Altitude Drone Detection (LADD) system consisting of Ku-band radar and an Electro-Optical/Infra-Red (EO/IR) camera. In this paper, we summarize recent technical advances in anti-drone systems around the world and introduce the features and describe the performance of the LADD system.

Comparative Analysis of the Electromyography Activity of Core Muscles During Balance Pad- and Sling-assisted Exercises

  • Liu, Yaoyao;Yoo, Won-gyu;Kim, Su-Jung
    • Physical Therapy Korea
    • /
    • v.27 no.4
    • /
    • pp.250-256
    • /
    • 2020
  • Background: Unstable surface-based core training can significantly enhance core strength, but no studies have compared the effects of balance pad- and sling-assisted exercises. Objects: To study the effects of unstable surface-based balance pad- and sling-assisted core strength exercises on muscle activity. Methods: Twenty male students aged 20-25 years participated in this study. The effects of three types of core strength exercises, performed with a sling or balance pad, on the activities of three muscles, i.e., the right musculus obliquus externus abdominis (EO), right erector spinae (ES), and right gluteus maximus (GM), were examined. Results: 1) In the glute bridge exercise, the percentage of maximum voluntary contraction of the EO, ES, and GM were significantly different between the balance pad- and sling-assisted exercises. The relative contribution of the ES and GM activities to all muscle activity were not significantly different between the two training types, whereas that for EO showed a significant difference. 2) There was no significant difference in the percentage value of maximum voluntary contraction (%MVC) among the EO, ES, and GM during the "leg-lifting with flat support" exercise, and there were no significant difference in the relative contributions between the two training types. 3) In the "side bridge leg separation exercise", the %MVC of the ES, EO, and GM were significantly different between the two training types. Conclusion: Sling training for core muscles was generally better than balance pad assist training. The majority of physiotherapy patients require core training. Our results could guide physiotherapists in the choice of targeted exercises for these patients.

Imaging Performance Analysis of an EO/IR Dual Band Airborne Camera

  • Lee, Jun-Ho;Jung, Yong-Suk;Ryoo, Seung-Yeol;Kim, Young-Ju;Park, Byong-Ug;Kim, Hyun-Jung;Youn, Sung-Kie;Park, Kwang-Woo;Lee, Haeng-Bok
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.174-181
    • /
    • 2011
  • An airborne sensor is developed for remote sensing on an aerial vehicle (UV). The sensor is an optical payload for an eletro-optical/infrared (EO/IR) dual band camera that combines visible and IR imaging capabilities in a compact and lightweight package. It adopts a Ritchey-Chr$\'{e}$tien telescope for the common front end optics with several relay optics that divide and deliver EO and IR bands to a charge-coupled-device (CCD) and an IR detector, respectively. The EO/IR camera for dual bands is mounted on a two-axis gimbal that provides stabilized imaging and precision pointing in both the along and cross-track directions. We first investigate the mechanical deformations, displacements and stress of the EO/IR camera through finite element analysis (FEA) for five cases: three gravitational effects and two thermal conditions. For investigating gravitational effects, one gravitational acceleration (1 g) is given along each of the +x, +y and +z directions. The two thermal conditions are the overall temperature change to $30^{\circ}C$ from $20^{\circ}C$ and the temperature gradient across the primary mirror pupil from $-5^{\circ}C$ to $+5^{\circ}C$. Optical performance, represented by the modulation transfer function (MTF), is then predicted by integrating the FEA results into optics design/analysis software. This analysis shows the IR channel can sustain imaging performance as good as designed, i.e., MTF 38% at 13 line-pairs-per-mm (lpm), with refocus capability. Similarly, the EO channel can keep the designed performance (MTF 73% at 27.3 lpm) except in the case of the overall temperature change, in which the EO channel experiences slight performance degradation (MTF 16% drop) for $20^{\circ}C$ overall temperate change.