• 제목/요약/키워드: Environmental water samples

검색결과 1,753건 처리시간 0.03초

파이로시퀀싱을 이용한 한강상수원보호구역 수계 중의 세균 다양성 (Analysis of Bacterial Diversity in Water from the Han River Water Source Protection Area via a Pyrosequencing Assay)

  • 김희정;권덕인;김창수;이시원
    • 한국환경보건학회지
    • /
    • 제42권4호
    • /
    • pp.274-279
    • /
    • 2016
  • Objectives: We investigated bacterial diversity in the Han River water resource protection area in order to provide basic microbiological information on the drinking water safety of the Seoul metropolitan region. Methods: Samples were collected in the spring and winter, but not during the rainy season. Pyrosequencing, gene amplification, and extraction of nucleic acids were employed in this study. Results: In total, 57 and 48 operational taxonomic units were respectively analyzed in samples collected during spring and winter. Proteobacteria were predominant in all samples. The samples contained phylogenetically diverse bacterial communities, with eleven major phyla and 36 genera. Cyanobacteria were predominant in the spring samples, but not in the winter samples. The predominant species in the samples collected during both seasons belonged to the genus Aquamicrobium and Bradyrhizobium. Moreover, no pathogenic bacteria were detected in the samples. Conclusion: Proteobacteria were predominant in the samples from the Han River water source protection area. Cyanobacteria were more predominant in the spring samples than in the winter samples, but Aquamicrobium and Bradyrhizobium were predominant in both sampling seasons.

생태독성 숙련도 시료의 적절성 평가 (Validation of Suitability on Proficiency Testing Samples for Acute Toxicity Test with Daphnia magna)

  • 신기식;박우상;이정서;유순주;박태진;김종민
    • 한국물환경학회지
    • /
    • 제31권1호
    • /
    • pp.49-54
    • /
    • 2015
  • Acute toxicity test with Daphnia magna has a variety of factors such as incubation condition of test species, food quality and proficiency of laboratory workers. Therefore, proper proficiency testing samples were required for evaluating the competence of laboratory workers. This study aims to propose some appropriate proficiency testing samples for laboratory workers of acute toxicity test with Daphnia magna. Proposed four kinds of standard samples (Sample A, B, C, and D) for proficiency testing were selected from reference materials which were recommended from Canada and USA WET(Whole Effluent Toxicity) authorities. Proposed standard samples were tested by trial application of proficiency testing, homogeneity and stability checks using repeatability test. Sample A, C and D were estimated ad the suitable candidates for proficiency test standard samples except for Sample B. In addition, Sample A was proved to be the most suitable sample.

Sensitive determination of pendimethalin and dinoseb in environmental water by ultra performance liquid chromatography-tandem mass spectrometry

  • Lim, Hyun-Hee;Park, Tae-Jin;Lee, Soo-Hyung;Shin, Ho-Sang
    • 분석과학
    • /
    • 제30권4호
    • /
    • pp.194-204
    • /
    • 2017
  • Direct injection (DI) and solid phase extraction (SPE) methods for the simultaneous determination of pendimethalin (PDM) and dinoseb (DNS) in environmental water have been optimized using the ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method. The limits of quantification (LOQs) of PDM and DNS were $0.01{\mu}g/L$ using the DI method and $0.0001-0.0002{\mu}g/L$ using the SPE method. The precision by SPE UPLC-MS/MS was less than 11 % for intra-day and inter-day analyses. When the proposed SPE method was used to analyze two analytes in environmental water, PDM was detected in a concentration range of $0.0002-0.011{\mu}g/L$ in 31 samples of the 114 surface water samples, and DNS was detected in a concentration range of $0.0005-0.045{\mu}g/L$ in 17 samples of the 114 surface water samples analyzed. When the DI method was used to analyze target compounds in the same samples, the detected concentrations of the two analytes were within 21% in samples with concentrations above $0.01{\mu}g/L$. The DI UPLC-MS/MS method can thus be used for the routine monitoring of PDM and DNS in environmental water, and the SPE LC-MS/MS method can be used for the determination of the ultra-trace PDM and DNS residues in environmental water.

Occurrence and Molecular Differentiation of Environmental Mycobacteria in Surface Waters

  • Lee, Eun-Sook;Lee, Mok-Young;Han, Sun-Hee;Ka, Jong-Ok
    • Journal of Microbiology and Biotechnology
    • /
    • 제18권7호
    • /
    • pp.1207-1215
    • /
    • 2008
  • To investigate the occurrence and species diversity of mycobacteria in waters, surface water samples were collected monthly from the Han River and tap water samples at the terminal sites of the distribution system. Mycobacteria in each water sample were isolated by decontamination using cetylpyridinium chloride (CPC) and cultivation on Middlebrook 7H10 agar, and then identified by polymerase chain reaction-restriction fragment length polymorphism analysis (PRA) and sequencing of the 65-kDa heat-shock protein gene (hsp65 gene). Mycobacteria were detected in 59% of the surface water samples and 26% of the tap water samples. Over half of the 158 isolates could not be identified by hsp65 PRA and gene sequencing, and several identification discrepancies were observed between the two methods. The most frequently isolated species was Mycobacterium gordonae in surface water and M. lentiflavum in tap water. M. avium complex (MAC), the most important pathogen among environmental mycobacteria, was detected in the surface water samples but not found in the tap water samples. The result demonstrated that water is an important environmental source of mycobacteria and the combined application of hsp65 PRA and sequencing was more reliable than hsp65 PRA alone to accurately identify mycobacteria present in water.

생태독성기준 미적용 업종 사업장 배출수 생태독성 수준 평가 (Evaluation of Effluent Toxicity which were Exempted from Applying of Ecotoxicity Criteria)

  • 김종민;신기식;이수형;이정서;이택준
    • 한국물환경학회지
    • /
    • 제33권2호
    • /
    • pp.197-202
    • /
    • 2017
  • This paper aimed to evaluate the test results of acute toxicity on effluent samples which were exempted from applying of ecotoxicity criteria. Total 316 effluent samples which were free from controlling of ecotoxicity regulation, were tested. Ratio of effluent samples which were exceeded the ecotoxicity criteria (TU > 1) indicated 23.7%. This ratio was a little bit higher than previous study (22.7%) on effluent samples which were controlled under ecotoxicity criteria. These results mean that our ecotoxicity management system is not appropriate and applying of ecotoxicity criteria to all effluent samples (82 industry categories) were needed in order to improve our ecotoxicity system. In addition, the same numeric criteria (TU 1 or 2) for all industry categories were proposed in consideration of these results. Ratio of effluent samples which exceeded the ecotoxicity criteria (TU > 1) with D. magna indicated 23.7%. However V. fischeri showed 14.6%. As a acute toxicity test organism, D. magna seemed to be more sensitive than V. fischeri. Ratio of samples which were exceeded TU 1 with D. magna by 24 h exposure period test indicated 35 %, whereas 48 h showed 41%.

춘천지역 일부 주민들의 먹는물 중 미량금속 및 무기 음이온에 대한 노출 (Exposure of Selected Chuncheon Residents to Trace Metals and Inorganic Anions in Drinking Water)

  • 김희갑;송진아;송병열
    • Environmental Analysis Health and Toxicology
    • /
    • 제24권4호
    • /
    • pp.293-301
    • /
    • 2009
  • This study was conducted to investigate the distribution of the concentrations of selected trace metals and inorganic anions in five types of drinking water samples (mineral spring water, well water, small community water, municipal tap water, and commercial mineral water) collected from Chuncheon, Gangwon-do in 2007. Forty four samples were analyzed for five metals and five anions using an atomic absorption spectrometer and an ion chromatograph, respectively. Arsenic (As) and nitrate (${NO_3}^-$) concentrations in some groundwater samples did not meet the future (10 ${\mu}g/L$) and current (44 mg/L) Korean drinking water standards, respectively. On the other hand, any municipal tap water samples, the sources of which were lake surface water, satisfied the Korean standards. Human health risk assessment results showed that arsenic in all types of water, especially groundwater including commercial mineral water, may pose both noncarcinogenic and carcinogenic effects on the residents. It is concluded that groundwater is not safe drinking water any longer and that a national survey and follow-up measures need to be taken.

폐수에서 이온불균형문제가 생태독성에 미치는 영향 평가 (Evaluation of Toxicity Influenced by Ion Imbalance in Wastewater)

  • 신기식;김종민;이수형;이정서;이택준
    • 한국물환경학회지
    • /
    • 제34권1호
    • /
    • pp.77-83
    • /
    • 2018
  • This paper aims to evaluate the results of toxicity testing with Daphnia magna and Vibrio fischeri on wastewater samples which might be influenced by ion imbalance. The effluents from factories were found to be more toxic with high salinity levels than those from public wastewater treatment plant (WTP) and sewage treatment plant (SWP). Clion composition was highest in the effluent, in terms of percentage, which was followed by $Na^+$, $SO_4^{2-}$ and $Ca^{2+}$. $K^+$ and $Mg^{2+}$ ion was relatively low. The sensitivity of D. magna test results was higher than V. fischeri. Among samples which were proved by V. fischeri testing to be nontoxic, the composition ratio of each ion whether toxic samples or nontoxic samples which were decided by D. magna toxicity testing, were compared. $Na^+$, $K^+$, $Ca^{2+}$, $Mg^{2+}$ ion composition ratio showed high level in nontoxic samples whereas $SO_4^{2-}$ and $Cl^-$ ion composition ratio was high in toxic samples. Accordingly, $SO_4^{2-}$ and $Cl^-$ ion seemed to be considered the ions causing toxicity in effluent. Toxicity from some categories of industries (Mining of non-metallic minerals, Manufacture of basic organic petrochemicals, Manufacture of other basic organic chemicals, Manufacture of other chemical products etc.) seemed to be influenced by salinity. The Ion concentration in influent and effluent were similar. Concentration of $Na^+$, $Cl^-$, $K^+$, $Ca^{2+}$ ions were high in influent, however $Mg^{2+}$ and $SO_4^{2-}$ ions were high in effluent.

The Determination of Dissolved Total Fe by Flow Injection Analysis in Environmental Samples

  • Kim, Do Hoon;Takeda, Kazuhiko;Sakugawa, Hiroshi;Lee, Jin Sik
    • 분석과학
    • /
    • 제14권6호
    • /
    • pp.510-515
    • /
    • 2001
  • There has been an increasing need for analytical methods of dissolved total iron (tFe) that are highly sensitive, rapid, inexpensive and simple for environmental samples. A sensitive flow injection analysis (FIA) method for determining the concentration of tFe in environmental samples was developed. The proposed method required 10 minutes and only $500{\mu}L$ of sample for and analysis. The standard deviation was 5.0% at $0.5{\mu}gL^{-1}$ (n=6), and the detection limit was $0.075{\mu}gL^{-1}$. The developed method was applied to environmental samples such as tap water, mineral water, rain, snow and cloud water. Since this FIA system was free form interferences of coexisting ions commonly found in samples, sub-${\mu}gL^{-1}$ level of tFe could be easily determined without further preconcentration and separation.

  • PDF

하수처리시설 고상시료 중 잔류의약물질 분석을 위한 전처리법 평가 및 적용 (Evaluation and application of pretreatment methods for pharmaceuticals and personal care products in the solid phase of sewage samples)

  • 박준원;김창수;주병규;이원석;정현미;정동환
    • 상하수도학회지
    • /
    • 제32권6호
    • /
    • pp.559-572
    • /
    • 2018
  • The aim of this study was to evaluate pretreatment methods for 27 pharmaceuticals and personal care products (PPCPs) in various sewage samples using a modified quick, easy, cheap, effective, rugged, and safe (QuEChERS) and online solid-phase extraction with LC-MS/MS. Extraction efficiencies of PPCPs in the solid phase under different experimental conditions were evaluated, showing that the highest recoveries were obtained with the addition of sodium sulfate and ethylenediaminetetraacetic acid disodium salt dehydrate in acidified conditions. The recoveries of target compounds ranged from 91 to 117.2% for liquid samples and from 61.3 to 137.2% for solid samples, with a good precision. The methods under development were applied to sewage samples collected in two sewage treatment plants (STPs) to determine PPCPs in liquid and solid phases. Out of 27 PPCPs, more than 19 compounds were detected in liquid samples (i.e., influent and effluent) of two STPs, with concentration ranges of LOQ-33,152 ng/L in influents and LOQ-4,523 ng/L in effluents, respectively. In addition, some PPCPs such as acetylsalicylic acid, ibuprofen, and ofloxacin were detected at high concentrations in activated sludge as well as in excess sludge. This methodology was successfully applied to sewage samples for the determination of the target compounds in STPs.

일부 농촌 지역의 간이 상수도와 Pump수의 수질에 관한 비교 연구조사 -춘성군 지역을 중심으로- (A Comparative study on drinking Water quality of simple piped Water supply Systems and water Pumps.)

  • 정문호;송금순
    • 한국환경보건학회지
    • /
    • 제9권1호
    • /
    • pp.77-84
    • /
    • 1983
  • A study was carried out to find drinking water qualities of 56 simple piped water supply systems and 37 water pumps in Chun Sung Conutry, Kang Won Province from 1st July to 30th August 1981. 1. The results of all kinds of water test are found to be safe at only one out of fifty six samples of simple piped water supply system at two out of thirty-seven samples of water pump and unsafe at the others. 2. In general Count of Bacteria test, twelve (21.4%) out of fifty six samples of the simple piped water are found to be safe for the legitimate standard of safty water, and five (13.5%) out of thirty=seven samples of pump water. 3. Escherichia coli group is negative at seven (12.5%) out of fifty-six samples of simple piped water, and eight (21.6%) out of thirty-seven samples of pump water. 4. The results of the physical and chemical examination of drinking water specimen are found to be safe at twelve out of fifty-six samples of simple piped water and at twenty-eight out of thirty-seven samples of pump water.

  • PDF