• 제목/요약/키워드: Environmental tests

검색결과 4,327건 처리시간 0.031초

Analysis of the influence of panel characteristics on odor measurement based on the air dilution olfactory method in Korea

  • Kim, Sun-Tae;Lee, Seokjun;Yim, Bongbeen
    • Environmental Engineering Research
    • /
    • 제24권1호
    • /
    • pp.91-98
    • /
    • 2019
  • This study was to objectify differences in the results of odor testing according to the characteristics of panel members that participate in air dilution olfactory method (ADOM) testing. When differences in the results of olfactory testing were reviewed in relation to characteristics of the panelists, the result of entire panels for the site boundary Proficiency Testing Materials (PTMs) showed no difference according to panelist sex, age, smoking status, and past participation in ADOM tests. As for the outlet PTMs, distinct differences appeared in relation to the smoking status and age of panelists. The frequency distribution for all the panelists (Dev($D/T_{total}$)) showed a form similar to a normal distribution, so it is thought to be more appropriate for the review of effect of panelist characteristics on the result of air dilution olfactory tests. In addition, the ADOM testing method implemented as the standard method for odor compounds in Korea (Dev($D/T_3$)) will have to be implemented along with a concurrent assessment, for the purpose of identifying the effect of panelist characteristics on administrative dispositions against malodors.

커피 찌꺼기의 카페인 용출 및 산화분해 특성 (Extraction of Caffeine from Spent Coffee Grounds and Oxidative Degradation of Caffeine)

  • 신민정;김영훈
    • 한국환경과학회지
    • /
    • 제27권12호
    • /
    • pp.1205-1214
    • /
    • 2018
  • During the past few decades, significant increase in the consumption of coffee has led to rapid increase in the production of coffee waste in South Korea. Spent coffee waste is often treated as a general waste and is directly disposed without the necessary treatment. Spent Coffee Grounds (SCGs) can release several organic contaminants, including caffeine. In this study, leaching tests were conducted for SCGs and oxidative degradation of caffeine were also conducted. The tested SCGs contained approximately 4.4 mg caffeine per gram of coffee waste. Results from the leaching tests show that approximately 90% of the caffeine can be extracted at each step during sequential extraction. Advanced oxidation methods for the degradation of caffeine, such as $UV/H_2O_2$, photo-Fenton reaction, and $UV/O_3$, were tested. UV radiation has a limited effect on the degradation of caffeine. In particular, UV-A and UV-B radiations present in sunlight cause marginal degradation, thereby indicating that natural degradation of caffeine is minimal. However, $O_3$ can cause rapid degradation of caffeine, and the values of pseudo-first order rate constants were found to be ranging from $0.817min^{-1}$ to $1.506min^{-1}$ when the ozone generation rate was $37.1g/m^3$. Additionally, the degradation rate of caffeine is dependent on the wavelength of irradiation.

Heterorhabditis megidis (Nematoda: Heterorhabditidae)에서 분리한 Bactonematicide, Photorhabdus temperata의 토끼 피부 및 눈자극 시험 (Dermal and Eye Irritation Studies on Bactonematicide, Photorhabdus temperata Isolated from Heterorhabditis megidis (Nematoda: Heterorhabditidae) in Rabbit)

  • 박순한;정남준;추영무;김영준;김진호
    • 한국유기농업학회지
    • /
    • 제30권3호
    • /
    • pp.423-439
    • /
    • 2022
  • The acute dermal and eye irritation tests of Photorhabdus temperata, a symbiotic bacterium of Heterorhabditis megidis Gwangju strain, were carried out in New Zealand white rabbit (Oryctolagus cuniculus), following the guidelines of OECD and Rural Development Administration (RDA) of Korea. In both tests, neither dermal nor eye responses were found from all the P. temperata treated rabbits and the results were classified as non-irritating. That is, erythema, eschar, edema, and any other dermal critical signs were not observed from all the experimental rabbits in the dermal irritation test. In the acute eye irritation test, no clinical signs of cornea, iritis, conjunctiva (redness, edema, lacrima, and chemosis) were observed from all the experimental rabbits. Individual ocular irritation, mean ocular irritation, and acute ocular irritation were calculated as 0.0. The results of dermal and eye irritation studies on P. temperata indicated that this bacterium could be a safe and effective alternative bionematicide against the most serious plant-parasitic root-knot nematodes in the genus Meloidogyne.

Experimental and numerical study of headed bars embedded in RC members under tension

  • Santana, Paulo F.M.;Silva, Patricia C.S.;Ferreira, Mauricio P.;Bezerra, Luciano M.;Oliveira, Marcos H.
    • Structural Engineering and Mechanics
    • /
    • 제84권4호
    • /
    • pp.531-546
    • /
    • 2022
  • Headed bars are often used when there is insufficient space for a straight or curved bar to be fully developed to ensure the transference of forces between steel and concrete in several types of connections between structural members. In such cases, the concrete breakout strength of the headed bars can be a critical point of the design and must be considered appropriately. This paper evaluates the tensile strength of headed bars embedded in reinforced concrete members, failing due to concrete breakout. Four experimental tests on headed bars embedded in slender concrete members are presented and discussed, showing that strength previsions from the design codes can be significantly conservative as they ignore the contribution from the flexural reinforcement. 3D finite element models were developed using Abaqus Unified FEA to simulate the tested specimens, and it was observed that they were able to reproduce the formation of the concrete cone accurately, besides the response and resistance observed in tests. Furthermore, the experimental, numerical, and design code resistances are compared and discussed. A new equation to evaluate the concrete cone strength of the tested headed bars is proposed, which takes into account parameters not explicitly considered in the current design equations.

철계 형상기억합금을 이용한 콘크리트 기둥의 전단보강 실험연구 (Experimental Study on Shear Retrofitting of Concrete Columns Using Iron-Based Shape Memory Alloy)

  • 정동혁;정새벽;최재희;김근오
    • 한국지진공학회논문집
    • /
    • 제28권1호
    • /
    • pp.41-46
    • /
    • 2024
  • The current study investigates the seismic performance of shear-dominant RC columns retrofitted with iron-based shape memory alloy (Fe SMA). Three RC columns with insufficient transverse reinforcement were designed and fabricated for lateral cyclic loading tests. Before testing, two specimens were externally confined with carbon fiber-reinforced polymer (CFRP) sheets and self-prestressed Fe SMA strips. The test results showed that both CFRP and Fe SMA performed well in preventing severe shear failure exhibited by the unretrofitted control specimen. Furthermore, the two retrofitted specimens showed ductile flexural responses up to the drift ratios of ±8%. In terms of damage control, however, the Fe SMA confinement was superior to CFRP confinement in that the spalling of concrete was much less and that the rupture of confinement did not occur.

대형 직접전단시험과 대형 삼축압축시험에 의한 조립재료의 전단강도 비교 (Comparison of Shear Strength of Coarse Materials Measured in Large Direct Shear and Large Triaxial Shear Tests)

  • 서민우;김범주;하익수
    • 한국지반환경공학회 논문집
    • /
    • 제10권1호
    • /
    • pp.25-34
    • /
    • 2009
  • 댐이나 항만 건설시 재료로 사용되는 조립재는 입자크기가 일반 토사에 비해 매우 크기 때문에 이러한 재료에 대해서 전단시험을 수행할 때에는 가급적 대형 전단시험장치를 사용하는 것이 보다 정확한 결과를 얻기 위해 바람직하다. 대형 전단시험장치로는 일반적으로 대형 직접전단시험장치와 대형 삼축압축시험장치가 있으나 일반 토질시험장치와 비교해 제작과 보급, 운영 등의 어려움 때문에 현재까지 국내에서 두 시험장치를 사용하여 시험을 수행한 실적은 많지 않은 편이다. 본 연구에서는 댐 축조재로 사용되는 입경이 큰 조립재료를 대상으로 시료의 평균 입자크기와 공시체 크기, 연직응력(구속압) 조건 등에 차이가 있는 총 6개 case에 대해서 대형 직접전단시험과 대형 삼축압축시험을 수행하고 두 시험간 전단강도 특성의 차이를 비교하였다. Mohr-Coulomb 강도규준에 의한 전단강도를 기준으로, 대형 직접전단시험을 통해 산정된 전단강도가 대형 삼축압축시험을 통해 산정된 전단강도보다 전체적으로 크게 나타났으며 또한, 1,000kPa 수직응력에 대해 두 시험간 산정된 전단강도를 비교한 결과 대형 직접전단시험에 의한 전단강도가 대형 삼축압축시험에 의한 전단강도보다 약 10~70% 크게 나타나 입경이 작은 일반 토사와 비교해 그 차이가 크고, 대형 직접전단시험결과의 분산도가 상대적으로 높은 것으로 나타났다.

  • PDF

난지도 하수슬러지 매립지반의 공학적 특성 (Engineering Properties of Sewage Sludge Landfill Ground in Nanji-Do)

  • 송영석;윤중만
    • 지질공학
    • /
    • 제17권1호
    • /
    • pp.125-133
    • /
    • 2007
  • 본 연구에서는 난지도 매립지내 하수슬러지만으로 이루어진 8호 매립장에 대하여 환경 및 지반공학적 특성을 조사한다. 이를 위하여 대상현장에 대하여 시료를 채취하고, 용출시험, 중금속 총량시험 등을 실시하여 환경적인 특성을 조사하였다. 중금속 총량시험결과 Pb, Zn, Cu, Ni, Cd, Cr 등의 성분이 검출되었으며, Cu의 경우 캘리포니아주 규제기준을 초과하므로 하수슬러지 재활용시 함량을 낮추어야 할 것이다 한편, 하수슬러지의 비중, 입도분석, 액소성한계, 다짐, 투수, 전단시험을 실시하여 지반공학적 특성을 조사하였다. 하수슬러지는 모래, 실트 및 점토로 구성되어 있으며, 소성지수는 42.3%로서 압축성이 큰 무기질 실트 혹은 유기질 점토인 것으로 분류된다. 다짐시험결과 건조단위중량이 낮고 다짐곡선이 비교적 평탄한 형태를 보이고 있으므로 함수비 변화에 따른 다짐효과가 비교적 적을 것으로 예상된다. 그리고 직접전단시험결과 점착력은 $0.058kg/cm^2$이고, 내부마찰각은 $14^{\circ}$ 것으로 나타났다. 대상현장의 하수슬러지는 다짐이 잘 되지 않으며, 전단강도도 비교적 낮으므로 매립지의 복토층 등으로 재활용할 경우 여러 가지 문제가 발생될 것으로 예상된다. 그리고 하수슬러지에 포함되어 있는 중금속의 용출에 따른 지하수 오염문제도 예상된다. 따라서 대상현장의 하수슬러지를 재활용하기 위해서는 이에 대한 보완 및 처리방안이 마련되어야 할 것이다.

TPH와 6가 크롬으로 오염된 지하수 처리를 위한 실내 실험 (Treatability Study on the Remediation Groundwater Contaminated by TPH Cr6+ : Lab-Scale Experiment)

  • 이규범;장윤영
    • 환경영향평가
    • /
    • 제28권3호
    • /
    • pp.332-345
    • /
    • 2019
  • 이 연구의 목적은 TPH 또는 $Cr^{6+}$이 함유된 오염 지하수의 처리 가능성을 평가하는 데 있다. 오일과 물의 분리, 용존 공기 부유 (DAF), 응고 및 침전, 모래와 활성탄으로 각각 여과를 위한 실험실 규모 테스트가 수행되었다. 총 40 분간의 분리 시간 동안 오일과 물의 분리 시험을 2 회 실시한 결과 TPH 제거율은 90.2 %였다. 높은 농도의 TPH 샘플에 대한 DAF 테스트의 경우, TPH 제거율은 미세 기포 크기의 변화에 따라 크게 변하지 않았다. 그러나 낮은 TPH 샘플에 대한 테스트는 미세 기포가 작을수록 TPH 제거율이 증가함을 보여준다. DAF 테스트를 위해 응집제를 샘플에 첨가했을 때 TPH 제거율은 12.3 % 증가했다. DAF에 의한 SS 제거율은 $16{\sim}40{\mu}m$에서 97.9 %였으며 미세 기포의 크기가 감소함에 따라 증가했다. 지하수에서 $Cr^{6+}$의 제거를 평가하기 위해 응집 및 침전 시험을 수행했다. $FeSO_4$ 투여량을 증가하였을때 응집 및 침전 공정에서 $Cr^{6+}$ 제거율이 증가하였다. 필터 매체에서 활성탄의 비율이 높을수록 여과공정에서 TPH 제거율이 증가한다. 여과에 의한 SS 제거율은 DAF 공정 시험 결과와 비슷한 96.7 %였다. 여과 과정은 TPH와 SS 농도가 감소하였다. 모래의 크기가 $425{\sim}850{\mu}m$이고 활성탄과 모래의 비율이 50:50일때 최적의 처리효율을 나타냈다.

탄성파 및 전기비저항을 활용한 지하복합 플랜트 건설 후보지 탐사 (Site-Investigation of Underground Complex Plant Construction by Seismic Survey and Electrical Resistivity)

  • 김남선;이종섭;김기석;김상엽;박정희
    • 한국지반공학회논문집
    • /
    • 제38권10호
    • /
    • pp.49-60
    • /
    • 2022
  • 지상공간의 건설부지 부족 현상으로 인한 도심지 지하화가 진행되고 있으며, 이에 따른 건설부지의 정확한 지반특성 평가가 요구되고 있다. 본 논문에서는 지하공간을 활용한 복합플랜트 후보부지에 대한 지반특성 파악하고자 시추조사와 다양한 물리탐사 방법 중 지표 탐사인 탄성파 굴절법 탐사와 전기비저항 탐사를 수행하였다. 시추조사는 BH-1 ~ BH-9까지 총 9개 시추공에서 수행하였으며, 일정한 간격을 유지하여 각 공에서의 지하수위 및 지질구조의 수직분포 등에 대한 정보를 획득하였다. 탄성파 굴절법 탐사에서 각 지층의 구간별 속도 및 지층 두께를 측정하였으며, 전기비저항 탐사는 쌍극자 배열법을 이용하여 지층의 전기비저항 분포를 파악하였다. 시추조사 결과를 종합하여 대상지반의 토사층 분류 및 기반암선을 파악하였으며, 물리탐사 결과를 통해 파쇄대와 같은 이상대를 평가하였다. 본 논문은 시추조사와 물리탐사 기법을 활용하여 지하복합 플랜트 후보부지에 대한 지반특성 파악하였고, 향후 시추조사와 물리탐사를 병행하는 지반조사에 참고 자료로 쓰일 수 잇다는 점에서 의의가 있다.

Study on the biodegradation of alternatives (four species including C8H8F9KO3S) for perfluorooctane sulfonate

  • Choi, Bong-In;Na, Suk-Hyun;Kwak, Yeong-Don;Ryu, Byung-Taek;Chung, Seon-Yong
    • Environmental Analysis Health and Toxicology
    • /
    • 제30권sup호
    • /
    • pp.8.1-8.5
    • /
    • 2015
  • Objectives The objective of this study was to evaluate the biodegradation potential of four perfluorooctane sulfonic acid (PFOS) alternatives that were developed at Changwon National University. While PFOS has been used widely in industrial and consumer products, it is known to be a persistent organic pollutant. Therefore, greener alternatives are highly desirable. Methods Biodegradation tests were run for 28 days using standard test protocols. The biochemical oxygen demand was measured daily throughout the experimental period, and the data were used to calculate the biodegradation rates. Microorganisms were isolated from the some of the tests that showed evidence of biodegradation. Results $C_8H_8F_9KO_3S$, which has the same number of carbons as the parent compound PFOS but a reduced number of fluorines, showed the highest biodegradation rate followed by $C_{10}H_8F_{13}KO_3S$. Chemical alternatives with lower number of carbons did not biodegrade readily in the experiments. Conclusions Together, these results suggest that it may be advantageous to develop PFOS alternatives with 8 carbons, the same as PFOS, but a reduced number of fluorines; as such, chemicals are more susceptible to biodegradation than the parent compound.