• 제목/요약/키워드: Environmental standard

검색결과 4,709건 처리시간 0.034초

춘천근교 약수의 계절별 수질에 관한 보건학적 조사연구 (A Study on Water Quality of Springs in the Suburbs of Chunchon City According to Seasons)

  • 한돈희;박영의;박찬정;전병구;박갑만
    • 한국환경보건학회지
    • /
    • 제13권1호
    • /
    • pp.7-16
    • /
    • 1987
  • A study was carried out to determine the adequacy of springs as drinking water in summer and in winter separately. In this study, environmental sanitation, physio-chemical examination, bacteriologic contamination and the content of heavy metal were included. For this study, samples were collected from 8 springs which were located in the suburbs of Chunchon city. The following results were obtained. 1. There was the covering system in 1 out of 8 springs. 6 out of 8 springs showed contaminating source within lorn. 2. In physio-chemical test, six out of 8 springs were found to be unsafe for the legitimate standard of safty water. 3. Bateriologic examination clone during summer showed the evidence of coilform group at 7 out of 8 springs and during winter showed positivity at 3 out of 8 springs. 4. In the study for heavy metal content, all places showed high iron level beyond the standard level of salty water, and 4 places showed high contents of fluorine, mangan and lead.

  • PDF

기계류부품의 가진시험 조건에 관한 연구 (Study of Vibration Test Condition for Machinery Component)

  • 김형의;박종원;정동수;강보식
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제6권1호
    • /
    • pp.27-36
    • /
    • 2006
  • It is increasingly important to ensure that a given vibration test specification of a particular machinery component is appropriately established by considering its real environmental conditions. Vibration test standards for electrical components are well documented, for example in an IEC 60068 series, while standards for machinery components are rarely found except a few military standards. Thus many vibration tests are performed based on the military standards. However, a test based on these military standards often results in over-testing, and under-testing in some cases due to the different environmental conditions. Also, these standards require an appropriate tailoring that may not be easily accomplished. In this paper, various international and military standards are compared and investigated to obtain test specifications relevant for machinery components. Also appropriate tailoring methods are demonstrated through a case study.

  • PDF

750kW 풍력발전기의 소음실증 (Noise Test and Evaluation of a 750kW Wind Turbine Generator)

  • 김석현;허욱;이현우
    • 산업기술연구
    • /
    • 제27권B호
    • /
    • pp.59-64
    • /
    • 2007
  • This study introduces an environmental noise evaluation procedure and results for a wind turbine (W/T) system. Test and evaluation are required by the international standard IEC 61400-11 in the aspect of environmental effect. Test and evaluation are performed on U-50 WT model which is first developed by the domestic W/T manufacturer. W/T test model is under operation in Daekwanryung wind test site. An integrated monitoring system in the test site is utilized for the evaluation. With the noise signal, meteorological data and W/T operational data are monitored in real time by the integrated monitoring system using LabVIEW. From the measured noise data, acoustic power level are estimated and compared with those of other similar size WT under the wind speeds required by international standard.

  • PDF

사고대비물질 취급자의 비상대응계획 작성 프로그램 연구 (Development of a Supporting Program for the Emergency Preparedness Plan)

  • 김성범;노혜란;석광설;박재득
    • 한국안전학회지
    • /
    • 제26권5호
    • /
    • pp.54-58
    • /
    • 2011
  • Emergency preparedness plan(EPP) is the systematic management of activities that involve a material degree of risk of loss or other damage to the surroundings(people, property and environment), and the boundary of accident recovery plan(ARP). The main purpose of the program is to provide a safety management system to each facility in order to enable to prevent accident and to control accident immediately. The EPP includes not only typical safety-related documentations such as material safety data sheet(MSDS), standard operation procedure(SOP), emergency response plan(ERP). EPP is established basis of the preliminary safety analysis involving risk identification, assessment and prevention plans. The program is also helpful for government or related agencies to control a number of accidents in small-scale companies in the whole country.

한반도 지역의 환경시험 온도 일주기 연구 (A Study on Daily Temperature Cycle of Environmental Test in the Korean Peninsula)

  • 이정용
    • 한국군사과학기술학회지
    • /
    • 제10권3호
    • /
    • pp.62-70
    • /
    • 2007
  • Most design temperature of environmental test in korea is based on the standard of Department of Defense. There are few studies to establish temperature standard. Besides the representative environmental test guide 'MIL-STD-810F' encourage to tailor to generate the most relevant test data possible and to test to make a match of test environment with operational environment. Under these circumstances, it is irrational to comply with baseless daily cycle. Thus the study about design method of test temperature is essential. So, the daily cycles to be appropriate to the Korean peninsula was presented in this study. And this research shows how to derive two main element, frequency-of-occurrence and daily maximum (minimum) temperature in daily cycles, in case we can not find the daily cycle.

Soil resistance estimation using smart instrumented dynamic penetrometers

  • Geunwoo Park;Namsun Kim;Yong-Hoon Byun;Sang Yeob Kim;Jong-Sub Lee
    • Smart Structures and Systems
    • /
    • 제34권1호
    • /
    • pp.63-72
    • /
    • 2024
  • In-situ penetration tests using dynamic penetrometers are widely used for estimating soil resistance. Additionally, these dynamic penetrometers have been instrumented to improve tests accuracy. This paper introduces smart instrumented dynamic penetrometers and discusses experimental studies for various cases. An energy monitoring module was developed to enhance the dynamic penetration tests. The standard penetration test (SPT) and instrumented dynamic cone penetrometer (IDCP) tests were conducted using the energy monitoring module. Dynamic responses obtained by the energy monitoring module were used to calculate the transferred energies into the rod head and tip to correct the evaluation of ground strength. In addition, a crosshole-type dynamic penetrometer (CDP) was developed to measure the penetration index and shear wave velocity simultaneously to estimate the strength and stiffness of ground. The results of this study indicate that smart instrumented dynamic penetrometers may be effectively used to characterize the strength and stiffness of ground.

유량-부하량관계식을 이용한 지석천 유역의 부하지속곡선 적용 및 유황별 유달율 산정 (Application of Load Duration Curve and Estimation of Delivery Ratio by Flow Durations Using Discharge-Load Rating Curve at Jiseok Stream Watershed)

  • 박진환;김갑순;황경섭;이용운;임병진
    • 한국물환경학회지
    • /
    • 제29권4호
    • /
    • pp.523-530
    • /
    • 2013
  • This study has been carried out to clarify the characteristics of discharge and pollutant loading according to flow conditions at jiseok stream watershed (JSW). A flow rate and pollutant load in the study watershed were estimated by equation of stage-discharge and discharge-loads rating curve. By using the methods above, I've evaluated the water quality (WQ) of the JSW if it is satisfied with the standard target. I've collected the data of BOD and T-P from the JSW every 8 days for the duration of 12 months. And then, I've schematized the data upon the load duration curve and the results showed me that the WQ of JSW was satisfied with the standard target. I've also collected the same data every each day for the duration of 12 months from JSW and have schematized the data again. And the results showed that it also was satisfied with the standard target. To be concluded, I've determined that point pollution sources of JSW gives more significant impacts to the WQ than non-point pollution sources of JSW and hence, as time goes, point pollution sources will keep depriciating the WQ of JSW. Therefore, further efforts will be required to JSW to maintain the WQ.

신도시 공동주택 거주자 대상의 녹색건축 인증제도 인식도 조사 및 분석 (A Study on the Recognition of Green Standard for Energy and Environmental Design(G-SEED) from the Survey of Multi-complex Residents in Newtown)

  • 목선수;박아름;조동우
    • KIEAE Journal
    • /
    • 제13권6호
    • /
    • pp.23-28
    • /
    • 2013
  • Green Standard for Energy and Environmental Design(G-SEED) has been used for environmental friendly building certification since 2002. The certification criteria initialed with multi-residential building and now it expands to 10 criteria for new and existing building types. The purpose of this study is to understand current recognition of G-SEED from the survey of multi-complex residences in newtown. From the general question, 75.2% of responders answered the period of living term between 1~3 years, 58.6% lived in $102.48{\sim}132.23m^2$ residential area and 65.2% owned their residences. The 43.2% of respondents recognized that their residences gained G-SEED certification by G-SEED emblem(31.6%). This is the significant meaning to understand public recognition of G-SEED and how to approach the strategy for raising the G-SEED recognition. The responders expected positive influence for economical value from G-SEED and also 75.3% of responders agreed with that G-SEED would be a decision make to buy and rent their residences. Second, residents responded that the consideration issue for green building is energy & prevention of environmental pollution(27.7%) which carries equal concern in G-SEED criteria category. The result of this survey verifies that the current level recognition of G-SEED of the responder's perspectives still is not well-known but it confirmed they have a positive expectation. Therefore, from this result, G-SEED needs to draw road map with detail plans for developing G-SEED with public participation.

환경기초시설의 인 기준 강화에 따른 팔당호 유입 수계의 수질개선 효과분석 (Study on the Improvement of Water Quality by the strengthening of T-P effluent standard for Environmental Facilities in Paldang Basin)

  • 정원구;한영한;임재명
    • 산업기술연구
    • /
    • 제30권B호
    • /
    • pp.125-135
    • /
    • 2010
  • The influences on water quality of each river by effluents from environmental facilities $located^{*}$ in 14 unit watersheds of North- and South-Han River, and Gyungan-cheon were analyzed. Also, the water quality modeling for study area was carried out to analyze the improvement effect of water quality by the strengthening of T-P effluent standard of environmental facilities. For the calibration and verification of model, water quality data and effluent loading calculated for 2006 were used. Data of low water period were used for calibration, and normal water period for verification. The results of calibration and verification were well matched with the real water quality dataset of revers. Also, the validity of the results were estimated using RI (Reliability Index) method. When the T-P effluent standards for environmental facilities were strengthened, T-P concentrations were predicted to improve from $0.025mg/{\ell}$ to $0.023mg/{\ell}$ in the outlet location of North-Han River, from $0.056mg/{\ell}$ to $0.040mg/{\ell}$ for South-Han River,and from $0.233mg/{\ell}$ to $0.146mg/{\ell}$ for Gyungan-cheon. Also, the T-P concentrations of tributaries including Jojong-cheon, Dal-cheong, Sumgang, Chungmi-cheon, Bokha-cheon, Heuk-cheon, and Wonju-cheon were predicted to improve from $0.063mg/{\ell}$ to $0.010mg/{\ell}$, from $0.091mg/{\ell}$ to $0.053mg/{\ell}$, from $0.199mg/{\ell}$ to $0.100mg/{\ell}$, from $0.168mg/{\ell}$ to $0.148mg/{\ell}$, from $0.186mg/{\ell}$ to $0.105mg/{\ell}$, from $0.019mg/{\ell}$ to $0.013mg/{\ell}$, and from $0.822mg/{\ell}$ to $0.236mg/{\ell}$, respectively.

  • PDF

SPT와 CPT 지반조사결과에 기초한 포항지역 액상화 위험도 평가 (Evaluation of Liquefaction Triggering for the Pohang Area Based on SPT and CPT Tests)

  • 김연준;고길완;김병민;박두희;김기석;한진태;김동수
    • 한국지반공학회논문집
    • /
    • 제36권10호
    • /
    • pp.57-71
    • /
    • 2020
  • 본 연구에서는 2017년 11월 15일 포항지진 시 액상화 위험도가 높았던 5개소의 부지에 대해 액상화 가능성을 재분석하였다. 액상화 지진 하중은 포항 지진파를 지반예측운동방정식(Ground motion prediction equation, GMPE)로 산정한 응답스펙트럼에 보정한 결과를 입력 지진파로 사용하였다. 지반의 액상화 저항력은 현장 시험 중 표준관입시험(Standard Penetration Test, SPT)과 콘관입시험(Cone penetration test, CPT)을 통해 결정되었다. 한편, 액상화 발생 가능성은 지반 액상화 지수(LPI)를 통해 정량화되었으며 이를 기존 연구 결과와 비교하였다.