• 제목/요약/키워드: Environmental specimens.

검색결과 1,383건 처리시간 0.033초

A Review of the Genus Sinopoda (Arachnida: Araneae: Sparassidae) in Korea

  • Kim, Byung-Woo
    • 환경생물
    • /
    • 제27권3호
    • /
    • pp.237-243
    • /
    • 2009
  • The giant crab spider genus Sinopoda in Korea is reviewed with detailed illustrations of male palpal organs. Three species, S. forcipata, S. stellatops, S. koreana are recognized with newly collected specimens. The first species is recorded newly in Korean spider fauna. A key to the species of the Korean Sinopoda spiders are also provided.

Results of Delamination Tests of FRP- and Steel-Plate-Reinforced Larix Composite Timber

  • LEE, In-Hwan;SONG, Yo-Jin;SONG, Da-Bin;HONG, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • 제47권5호
    • /
    • pp.655-662
    • /
    • 2019
  • This study evaluated the multi-bonding performances of timbers as well as those of reinforcement and timber to obtain data for preparing guidelines regarding the use of timbers as large structural members. For the multi-bonding performances of timbers, four types of bonding surfaces were prepared according to the pith position. For the bonding performances of FRP (fiber-reinforced plastic)/steel plate and timber, a total of 11 types of specimens were produced for the selection of the appropriate adhesive. The bonding performances of the produced specimens were evaluated through a water soaking delamination test, a water boiling delamination test, and a block shear strength test. The test results showed that the bonding strength of the bonding surface according to the pith position was highest in the specimen for which the two sections with the pith at the center of the cross-section on timber and between the bonding surfaces (the tangential and radial sections were mixed) were bonded. Furthermore, the specimens for which the section (radial section) with the pith on the bonding surface of the timber was bonded showed a high delamination percentage. The results of the block shear strength test showed that the bonding section did not have a significant effect on the shear strength, and that the measured wood failure percentage was higher than the KS standard value. The PVAc adhesive showed the highest bonding strength between larix timber and GFRP (glass FRP). Furthermore, the epoxy and polyurethane adhesives showed good bonding strength for CFRP (carbon FRP) and structure steel, respectively.

Modified electrical conductivity test method for evaluation concrete permeability

  • Pilvar, Amirreza;Ramezanianpour, Ali Akbar;Rajaie, Hosein
    • Computers and Concrete
    • /
    • 제16권6호
    • /
    • pp.865-880
    • /
    • 2015
  • Standard test method for bulk electrical conductivity (ASTM C1760) provides a rapid indication of the concrete's resistance to the penetration of chloride ions by diffusion. In this paper a new approach for assessing the bulk electrical conductivity of saturated specimens of hardened concrete is presented. The test involves saturating concrete specimens with a 5 M NaCl solution before measuring the conductivity of the samples. By saturating specimens with a highly conductive solution, they showed virtually the same pore solution conductivity. Different concrete samples yield different conductivity primarily due to differences in their pore structure. The feasibility of the method has been demonstrated by testing different concrete mixtures consisting ordinary and blended cement of silica fume (SF) and calcined perlite powder (CPP). Two standard test methods of RCPT (ASTM C1202) and Bulk Conductivity (ASTM C1760) were also applied to all of the samples. The results show that for concretes containing SF and CPP, the proposed method is less sensitive towards the variations in the pore solution conductivity in comparison with RCPT and Bulk Conductivity tests. It seems that this method is suitable for the assessment of the performance and durability of different concretes containing supplementary cementitious materials.

Re-evaluation of the Genus Antrodia (Polyporales, Basidiomycota) in Korea

  • Park, Myung Soo;Quan, Ying;Jung, Paul Eunil;Oh, Seung-Yoon;Jang, Yeongseon;Kim, Jae-Jin;Lim, Young Woon
    • Mycobiology
    • /
    • 제42권2호
    • /
    • pp.114-119
    • /
    • 2014
  • The wood decay fungi Antrodia P. Karst. play important ecological roles and have significant industrial and economic impacts as both wood degraders and sources of pharmaceutical and biotechnological products. Although each Antrodia species has distinct morphological characteristics, the misidentification rate is especially high due to their simple morphological characters. A combination of morphological and internal transcribed spacer region sequence analyses revealed that 27 of 89 specimens previously identified by morphology alone were correct, whereas 35 of these specimens were misidentified as other Antrodia species. We report here that seven Antrodia species exist in Korea (A. albida, A. heteromorpha, A. malicola, A. serialis, A. sinuosa, A. sitchensis, and A. xantha) and based on these specimens, we provide taxonomic descriptions of these species, except for A. serialis, which was only confirmed by isolate.

점용접 아연도금판의 강도특성에 대한 온도 및 침수의 영향 (Effect of Temperature and Water Assumtion on Strength of Spot Welded Zine Steel Plates)

  • 서도원;윤호철;최준용;임재규
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.358-363
    • /
    • 2003
  • Spot welded structure is operated in diverse situation because of temperature, humidity and precipitation. In addition factors of environmental pollution such as acid rain, that courses corrosion, have the tendency to increase, But spot welded structure strength is affected by dampness and environment temperatures. Therefore, it is important to evaluate effect of temperature of spot welded part, In this study, the strength distribution of spot welded plates is evaluated about the environmental temperature of zine coated steel plates and test is conducted with welded part immersed in distilled and synthetic sea water. Specimens are immersed into water for 10, 100, 500 and 1000hours to evaluate the effects of water immersion time on tensile-shear strength under the conditions of -40, 0, 20 and $50^{\circ}C$. Strength is evaluated by tensile-shear test. The conditions of spot welding are 240kgf electrode force, 10KA welding current with 0 and 5mm clearance. From this study, spot welded specimens with clearance have lower tensile-shear strength in the distilled water or synthetic sea water comparing with spot welded specimens without clearance. And they have lower tensile-shear strength under $-40^{\circ}C$ and over $50^{\circ}C$.

  • PDF

도계장 유래 닭고기와 부산물 및 환경재료에서 Listeria spp의 분리 및 분리균의 특성 I. Listeria spp의 분리 (Characteristics and isolation of Listeria spp from poultry meat, products and environmental specimens in chicken slaughterhouse I. Isolation of Listeria spp)

  • 손원근;강호조
    • 대한수의학회지
    • /
    • 제31권3호
    • /
    • pp.271-277
    • /
    • 1991
  • To investigate the epidemiological trait of listeriosis, Listeria spp were isolated from poultry meat, products and environmental specimens in chicken slaughterhouse. Also determined were isolation rates by the different enrichment procedures, the biochemical properties of isolates. In a total of 307 samples including poultry meat, liver, feathers, feces, chiller water, scalding water overflow and slaughterhouse floor, Listeria spp were isolated predominantly from scalding water overflow (90.0%), body skin before washing (66.7%), liver (20.0%) and feathers(15.0%) However, few Listeria spp were isolated from body skin after washing and feces. The higher isolation rates were obtained in the secondary enrichment procedure (7.2%) than in the primary enrichment (3.9%); after stored the secondary enrichment cultures for 2 weeks at $4^{\circ}C$, Listeria spp were present in 9.8%. The majority of the isolated Listeria spp were identical to those of the standards strains in biochemical and cultural properties. Overall, Listeria spp were present in 13.4% of the specimens tested, and were in order of prevalence of L innocua(11.1%), L monocytogenes(3.3%), L grayi(0.7%) and L murrayi(0.3%).

  • PDF

CHEMICAL COMPATIBILITY OF SOIL-BENTONITE CUT-OFF WALL FOR IN-SITU GEOENVIRONMENTAL CONTAINMENT

  • Inui, Toru;Takai, Atsushi;Katsumi, Takeshi;Kamon, Masashi;Araki, Susumu
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회 3차
    • /
    • pp.135-139
    • /
    • 2010
  • A construction technique to install the soil-bentonite (SB) cut-off wall for in-situ geoenvironmental containment by employing the trench cutting and re-mixing deep wall method is first presented in this paper. The laboratory test results on the hydraulic barrier performance of SB in relation to the chemical compatibility are then discussed. Hydraulic conductivity tests using flexible-wall permeameters as well as swell tests were conducted for SB specimens exposed to various types and concentrations of chemicals (calcium chloride, heavy fuel oil, ethanol, and/or seawater) in the permeant and/or in the pore water of original soil. For the SB specimens in which the pore water of original soil did not contain such chemicals and thus the sufficient bentonite hydration occurred, k values were not significantly increased even when permeated with the relatively aggressive chemical solutions such as 1.0 mol/L $CaCl_2$ or 50%-concentration ethanol solution. In contrast, the SB specimens containing $CaCl_2$ in the pore water had the higher k values. The excellent linear correlation between log k and swelling pressure implies that the swelling pressure can be a good indicator for the hydraulic barrier performance of the SB.

  • PDF

Thermomechanical behavior of alkali-activated slag/fly ash composites with PVA fibers exposed to elevated temperatures

  • Kim, J.S.;Lee, H.K.
    • Advances in concrete construction
    • /
    • 제11권1호
    • /
    • pp.11-18
    • /
    • 2021
  • The present study fabricated polyvinyl alcohol (PVA) fiber-reinforced alkali-activated slag/fly ash (AASF) composites with varying mixture ratios of slag and fly ash. The thermomechanical behaviors of the AASF composites exposed to 200, 400, 600, or 800℃ were evaluated by means of compressive strength test, visual observation, and fire resistance tests. X-ray diffractometry, mercury intrusion porosimetry, and thermogravimetry tests were performed to analyze the microstructure change of the AASF composites upon exposure to high temperatures. Specimens exhibited a gradual strength loss up to 600℃, while also showing a significant decrease in the strength above 600℃. The fire resistance test revealed the occurrence of an inflection point as indicated by an increase in the internal temperature at around 200℃. In addition, specimens showed the dehydration of C-S-H gel, the presence of åkermanite, gehlenite, and anorthite upon exposure to 800℃, which is associated with the formation of macropore population with pores having diameters of 1-3 ㎛ and 20-40 ㎛. Visual observation indicated that the PVA fibers mitigated the cracking and/or spalling of the specimens upon exposure to 800℃.

Experimental study on durability of strengthened corroded RC columns with FRP sheets in tidal zone of marine environment

  • Kashi, Amin;Ramezanianpour, Ali Akbar;Moodi, Faramarz
    • Computers and Concrete
    • /
    • 제19권4호
    • /
    • pp.339-346
    • /
    • 2017
  • The main objective of this paper was to illuminate the effect of marine environmental condition on durability of reinforced concrete (RC)-corroded columns strengthened with carbon fiber reinforced polymer (CFRP) and glass fiber reinforced polymer (GFRP) layers. Small-scale columns were prepared and corroded by an accelerated corrosion process. After strengthening, compressive strength tests were carried out on control and weathered specimens. In this research, a marine simulator was designed and constructed similar to the tidal zone of marine environment in south of Iran which was selected as a case study in this research. Mechanical properties of wrapped specimens were studied after placing them inside the simulator for 3000 hours. Marine environment decreased ultimate strength by 4.5% and 26.3% in CFRP and GFRP-wrapped columns, respectively. In some corroded-columns, strengthening was carried out after replacing damaged cover by self-compacted mortar. In this method, by confining with one layer of CFRP and GFRP, 4.2% and 22.4% reduction in ultimate strength was observed, respectively, after exposure. Furthermore, the elastic-brittle behavior has been verified in this retrofit method. Also results of tension tests revealed, the ultimate tensile strength was degraded by 2% and 28.8% in CFRP and GFRP sheets, respectively, after applying marine exposure.

소형 연소장치를 이용한 음식폐기물 연소 특성 연구 (A Study on the Combustion Characteristics of Food Waste Using the Experimental Apparatus for Combustibility)

  • 채종성;양승재;김석완;이재희;엄태인
    • 신재생에너지
    • /
    • 제16권2호
    • /
    • pp.47-53
    • /
    • 2020
  • The amount of food waste and its water content depends on both the season and region. In particular, the water content typically varies between 73.8 wt.% and 83.3 wt.%, depending on the proportion of vegetables. Current food waste drying technologies are capable of reducing the water content to less than 10 wt.%, while increasing the heating value. Ongoing studies aim to utilize dried food waste as fuel. Food waste can be used to produce solid refuse fuel (SRF) by mixing it with various solid fuels or other types of waste. The analysis of specimens is very important when considering the direct combustion of food waste or its co-firing with solid fuels. In this study, the weight reduction of specimens after burning them in a small combustor, and compared with the results of thermogravimetric analysis (TGA). The concentration of various chemicals was also measured to define the characteristics of waste generation. Performed proximate analysis, elemental analysis, TGA, combustion experiment, the heating value, and derivative thermogravimetry (DTG).