• 제목/요약/키워드: Environmental specimens.

검색결과 1,375건 처리시간 0.027초

제강공장 고철 용해공정 근로자의 납 노출실태 (Lead Exposure Status of Smelt Process Workers in Steelmaking using Scrap Iron)

  • 구동철;이재환;한아름;김현주;이수연;윤순영;이채관
    • 한국산업보건학회지
    • /
    • 제23권2호
    • /
    • pp.164-168
    • /
    • 2013
  • Objectives: This study was aimed at the examination of the lead exposure status of smelting process workers in steelmaking using scrap iron. Methods: The study was conducted from July to September 2012 by means of measurements taken during the smelting process, with 45 minutes set for a one-time smelting work cycle when it comes to personal air sample and area air sample. As such, daily work hours were classified into 360 minutes for measurement. The analysis of lead concentration was conducted using AAs based on the NIOSH 7300 method. Results: In the case of the personal specimens that were subjected to periodical measurement 45 minutes per one session during the smelting process, 40 out of 42 specimens measured were found to contain lead, with an average concentration level of $0.028mg/m^3$ (Max: $0.182mg/m^3$, Min: $0.005mg/m^3$, TWA-more than 50%: 4 out of 6 units). In the case of regional specimens, lead was detected in 45 out of 48 specimens measured, with an average concentration level of $0.037mg/m^3$ (Max: $0.220mg/m^3$, Min: $0.007mg/m^3$ ). In the case of regional specimens subjected to measurement using a day as the work cycle, lead was detected in 15 out of 15 specimens measured, with an average concentration level of $0.049mg/m^3$ (Max: $0.478mg/m^3$, Min: $0.005mg/m^3$ ). Conclusions: It concluded that smelting process workers in steelmaking are exposed to lead because scrap iron is used as a raw material. It is thus necessary to introduce legal management to prevent occupation-related disease in smelting process workers in steelmaking.

복합적인 환경인자가 탄소섬유강화 복합재의 기계적 및 열분석 특성에 미치는 영향 (Effects of Combined Environmental Factors on Mechanical and Thermal Analysis Properties of Graphite/Epoxy Composites)

  • 이상진;이종근;윤성호
    • 대한기계학회논문집A
    • /
    • 제26권7호
    • /
    • pp.1416-1425
    • /
    • 2002
  • In this study, the effects of combined environmental factors on mechanical and thermal analysis properties of graphite/epoxy composites were evaluated by the use of an accelerated aging test. Environmental factors such as temperature, moisture. and ultraviolet were considered. A xenon-arc lamp was utilized for ultraviolet light. and exposure times of up to 3000 hours were applied. Several types of specimens - tensile. bending, and shear specimens those are transverse to the fiber direction, and bending specimens those are parallel to the tiber direction - were used to investigate the effects of environmental factors on mechanical properties of the composites. Also, glass transition temperature, storage shear modulus, loss shear modulus, and tan ${\delta}$ were measured as a function of exposure times through a dynamic mechanical analyzer. In addition. a suitable testing method for determining the effect of environmental factors on mechanical properties is suggested by comparing the results from using two different types of strain measuring sensors. Finally, composite surfaces exposed to environmental factors were examined using a scanning electron microscope.

도축처리 단계별 도체 및 환경재료에서 Listeria monocytogenes의 분리 (Isolation of Listeria monocytogenes from animal carcasses and environmental specimens in slaughter house level)

  • 허정호;손성기;이주홍;임삼규;구정헌;박영호;조명희;손원근;강호조
    • 한국동물위생학회지
    • /
    • 제20권1호
    • /
    • pp.69-77
    • /
    • 1997
  • To invastigate the epidemiological trait of listeriosis, Listeria monocytogenes were isolated from the carcasses of pigs and cattle, and environmental specimens in slaughter house. Also serotype of isolates were classified by rapid slide agglutination test. In the carcasses of pigs, Listeria sp were isolated from the carcasses after bleeding(62%), after dismemberment(60.0%) and before shipping(76.0%), and L monocytogenes were present in 8% of the carcasses after dismemberment and in 14% of the carcasses before shipping. However, few Listeria sp were isolated from the living body skin and the carcasses after scalding. In the carcasses of cattle, Listeria sp were isolated from the carcasses after bleeding(10%), after dismemberment(36.7%) and before shipping(63.3%), L monocytogenes were present in 3.3% of the carcasses after dismemberment and in 10% of the carcasses before shipping. Overall, L monocytogenes, L innocua, L welshimen, L grayi, and L murrayi were present In 4.8, 40, 2.3, 2.6 and 0.3% of all the carcasses, respectively. Prevalence of Listeria sp in environmental specimens were found to be 80% in slaughter house floors and 100% in sewage, and L monocytogenes were present in 15% of sewage. However, few Listeria sp were isolated from chilled water and from scalding water. Overall, L monocytogenes, L innocua, and L welshimeri were present in 3.8, 45 and 6.3% of all the environmental specimens, respectively. A total 27 strains of L monocytogenes were isolated from samples tested and all of the strains were classified into serotype 1.

  • PDF

환경시료은행의 국제적 동향 및 우리의 대응 (International Trends of Environmental Specimen Bank and Our Response)

  • 김명진;유병호;이석조;이종천;이철우
    • 환경영향평가
    • /
    • 제17권4호
    • /
    • pp.225-233
    • /
    • 2008
  • An Environmental Specimen Bank (ESB) is an archive for samples that can be used to document and assess the quality of the environment in which we live. An ESB program looks at changes in the concentration of human and environmental specimens over long periods of time through retrospective analysis of archived samples of a particular area collected at regular intervals. The idea of ESB was first proposed by German and American scientists in the early 1970s and has been established since 1979 in Germany, USA, and Japan. Korea plans to establish a National Environmental Specimen Bank (NESB) in 2010. The NESB will be able to assess and improve the quality of analytical measurements as well as to compare the past and current environmental quality as a time capsule. The concept and design for the NESB facility was developed and its Standard Operation Procedures (SOPs) are being developed based on an evaluation of ESBs and SOPs of Germany, USA, and Japan. Environmental specimens proposed for banking are based on typical representatives of every level of the food chain from each type of ecosystem that are widely distributed thus enabling comparisons between different sampling areas. Through retrospective analysis of environmental specimens, the NESB will improve the reliability of environmental monitoring, ecological risk assessment, and health impact assessment.

A Study of Aging Effect for Train Carbody Using Accelerated Aging Tester

  • Nam, Jeong-Pyo;LI, Qingfen;LI, Hong
    • International Journal of Railway
    • /
    • 제1권3호
    • /
    • pp.113-116
    • /
    • 2008
  • The long-tenn exposure of polymeric composite materials to extreme-use environments, such as pressure, temperature, moisture, and load cycles, results in changes in the original properties of the material. In this study, the effect of combined environmental factors such as ultraviolet ray, high temperature and high moisture on mechanical and thermal analysis properties of glass fabric and phenolic composites are evaluated through a 2.5 KW accelerated environmental aging tester. The environmental factors such as temperature, moisture and ultraviolet ray applied of specimens. A xenon-arc lamp is utilized for ultraviolet light and exposure time of up to 3000 hours are applied. Several types of specimens - tensile, bending, and shear specimens that are warp direction and fill direction are used to investigate the effects of environmental factors on mechanical properties of the composites. Mechanical degradations for tensile, bending and shear properties are evaluated through a Universal Testing Machine (UTM). Also, storage shear modulus, loss shear modulus and tan a are measured as a function of exposure time through a Dynamic Mechanical Analyzer (DMA). From the experimental results, changes in material properties of glass fabric and phenolic composites are shown to be slightly degraded due to combined environmental effects.

  • PDF

Application of RTI to Improve Image Clarity of a Trace Fossil Cochlichnus Found from the Jinju and Haman Formations

  • Sangho Won;Dal-Yong Kong
    • 자원환경지질
    • /
    • 제56권4호
    • /
    • pp.397-408
    • /
    • 2023
  • A total of 64 specimens of trace fossils were collected from the Jinju Formation of the construction site of Jinju Aviation Industrial Complex, and from the Haman Formation of Namhae Gain-ri fossil site. The fossils are continuously and regularly meandering sine-curve in shape. The fossil varies in morphology: width between 0.2 and 5.6 mm, wavelength between 1.5 and 28 mm, and amplitude between 0.9 and 7.9 mm; the Jinju specimens are commonly wider than the Haman ones. The ratio of wavelength to amplitude is more or less regular regardless of width of the specimen, and the linear correlation of the ratios shows that the Jinju specimens fit better than the Haman specimens. Taking all morphometric parameters, specimens in all size ranges are temporarily identified as ichnospecies Cochlichnus anguineus. In order to obtain more distinct and clearer images of Cochlichnus, we selected two specimens and applied a new imaging technology RTI. For photography of the trace fossils, 50 to 80 images were taken per set with photometric lighting close to the surface and horizontally. RTI technology clearly showed that the images of tiny fossils were improved: the surface contrast become sharper and messy and unnecessary information disappeared. Currently, RTI technology is used in many fields including preservation of cultural properties and archaeology. As a consequence, we hope to apply this technique to the field of paleontology, especially to the study of trace fossils of very small size.

고온 다습하에서 복합절연재료의 열화특성 (The aging characteristics of composite insulating materials due to high-temperature and high-moisture)

  • 이종호;이규철;김순태;박홍태
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제7권1호
    • /
    • pp.15-24
    • /
    • 1994
  • For increasing the insulating proper-ties and the reliability of composite materials due to environmental aging, the electrical and mechanical characteristics of moisture absortion specimens and moisture desorption specimens were investigated. After moisture absorption wt% and moisture desorption wt% increased with time, a state of saturation arrived subsequent to a constant time. Moisture absorption constants with the layers of glass fiber showed 0.0117 in 1 layer, 0.0123 in 2 layers and 0.0152 in 3 layers. Electrical and mechanical characteristics dropped significantly with moisture absorbing in composite materials. Although moisture dried completly at 70.deg. C, it is impossible to obtain the electrical and mechanical characteristics before moisture absorption. Many defaults by moisture in composite materials exist at interface between epoxy matrix and filler.

  • PDF

Benefits of Puddling of Fiber Reinforced UHSC for Enhanced Transmission of Column Loads

  • Lee, Joo-Ha;Kim, Gyu-Dong;Yoon, Young-Soo
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.75-78
    • /
    • 2005
  • This study reports on the structural characteristics of slab-column connections using an ultra-high-strength-fiber-reinforced concrete. Compression tests were performed on two slab-column and four isolated column specimens. During the column load tests were performing on the slab-column specimens, the slab loads were also applied to consider actual confinement condition at the slab-column joint. The main parameter investigated was the ' puddling ' of ultra-high-strength-fiber-reinforced concrete. This paper also investigates the effects of some parameters on slab-column specimens and isolated column specimens without the surrounding slab for their ability to transmit axial loads from the ultra-high-strength concrete columns through slab-column connections. The beneficial effects of the ultra-high-strength-fiber-reinforced concrete puddling on the transmission of column loads through slab-column connections are demonstrated.

  • PDF

Pull-out Strengths of GFRP-Concrete Bond Exposed to Applied Environmental Conditions

  • Kabir, Muhammad Ikramul;Samali, Bijan;Shrestha, Rijun
    • International Journal of Concrete Structures and Materials
    • /
    • 제11권1호
    • /
    • pp.69-84
    • /
    • 2017
  • This paper presents results of an experimental investigation on the behaviour of bond between external glass fibre reinforced polymer reinforcement and concrete exposed to three different environmental conditions, namely, temperature cycles, wet-dry cycles and outdoor environment separately for extended durations. Single shear tests (pull-out test) were conducted to investigate bond strengths (pull-out strengths) of control (unexposed) and exposed specimens. Effect of the exposure conditions on the compressive strength of concrete were also investigated separately to understand the effect of changing concrete compressive strength on the pull-out strength. Based on the comparison of experimental results of exposed specimens to control specimens in terms of bond strengths, failure modes and strain profiles, the most significant degradation of pull-out strength was observed in specimens exposed to outdoor environment, whereas temperature cycles did not cause any deterioration of strength.

Fatigue experiment of stud welded on steel plate for a new bridge deck system

  • Ahn, Jin-Hee;Kim, Sang-Hyo;Jeong, Youn-Ju
    • Steel and Composite Structures
    • /
    • 제7권5호
    • /
    • pp.391-404
    • /
    • 2007
  • This paper presents push-out tests of stud shear connectors to examine their fatigue behavior for developing a new composite bridge deck system. The fifteen push-out specimens of D16 mm stud welded on 9 mm steel plate were fabricated according to Eurocode-4, and a series of fatigue endurance test and residual strength test were performed. Additionally, the stiffness and strength variations by cyclic loading were compared. The push-out test, when the stiffness reduction ratio of the specimens was 0.95 under cyclic load, resulted in the failure of the studs. The stiffness variation of the push-out specimens additionally showed that the application of cyclic loads reduced the residual strength. The fatigue strength of the shear connectors were compared with the design values specified in the Eurocode-4, ASSHTO LRFD and JSSC codes. The comparison result showed that the fatigue endurance of the specimens satisfies the design values of these codes.