• Title/Summary/Keyword: Environmental regulation standard

Search Result 154, Processing Time 0.024 seconds

Environmental Regulation, Firm Heterogeneity and Innovation (환경규제, 기업 이질성, 그리고 기업의 혁신 활동에 대한 행태적 접근)

  • Park, Minje;Jin, Byungchae
    • Journal of Technology Innovation
    • /
    • v.30 no.1
    • /
    • pp.21-56
    • /
    • 2022
  • Since Michael Porter (1991) has proposed that environmental regulation can help a firm increase its competitiveness by encouraging it to engage in more innovative activities to meet the environmental regulation, a number of researchers have empirically investigated the "Porter Hypothesis." However, the empirical results still remain mixed. Combining the perspectives of the behavioral theory of the firm and firm heterogeneity, we argue that the levels of regulation stringency and time-pressure would differentially influence a firm's innovative behavior depending on the firm's aspiration level, performance feedback and technological capabilities. Using the U.S. Corporate Average Fuel Efficiency (CAFE) regulation context, we empirically demonstrate that lagging firms that do not meet the new regulation standard announced by the government tend to search for more distant knowledge and that the impact of the patents they file for decreases as the regulation becomes more stringent. In addition, we also find that as time-pressure increases, lagging firms stand to apply for more patents than do leading firms whereas the overall impact of the patents decreases. These results help us advance our understanding of the nuanced causal relationship between regulation and innovation and provide practical implications for policymakers.

A Study on the Permit Method for a New or an Enlarged Facilities According to the Implementation of Air Pollutant Emission-Cap Regulation in Metropolitan Area (수도권 사업장 대기총량제 시행에 따른 신·증설 사업장 허가기준 개발 연구)

  • Kim, Hong-Rok;Yoon, Young-Bong;Ko, Byung-Churl;Shin, Won-Geun;Kim, Dong-Joong;Lee, Myung-Hwoon
    • Journal of Environmental Impact Assessment
    • /
    • v.16 no.4
    • /
    • pp.301-310
    • /
    • 2007
  • For the improvement of air quality in the metropolitan area, Korea has enforced the air pollutant emission cap regulation from the 1st of July, 2007, and the companies that intend to install a new or an enlarged facility in the metropolitan area will be restricted. However, the current regulation on permission does not describe a standard of judgement distinctly. In this study, therefore, a method of permission on the installation of a new or an enlarged facility was developed by supplementing the law in force based on the foreign cases. To develop a specific permit regulation and procedure, the developed nations' cases such as US, Canada, EU were reviewed thoroughly. Also, an appropriate method was suggested to apply domestically for a new or an enlarged facility permit within the regulations of the metropolitan special law. The method consists of first, calculating the possible permit quantity from the difference between an estimated annual emission cap and the annual emission provided by the implementation plan in each region. Second, permitting a new or an enlarged facility construction within the difference of the emission between the regional emission cap and the implementation plan in 2014. Third, distributing emissions allowable to each performance year based on the regional emission cap and the implementation plan in 2014. Fourth, making use of the emission difference between the implementation plan and the performance result in each year. Considering the general domestic conditions, the convenience of the permit authority and permitted companies, the most reasonable method was to use the fourth. To enforce the suggested permit method in a more flexible way, parts of the related regulations need to be revised and continuous research and analysis on the results from the implemented system and on foreign cases is necessary to develop this method a suitable system for domestic conditions and to settle the air pollutant emission cap system.

A Case Study for Reasonable Emission Regulation of Odor Exhaust Stack (악취 배출구의 합리적인 배출규제를 위한 사례연구)

  • Park, Jeong-Ho;Lee, Hyung-Chun
    • Journal of Environmental Science International
    • /
    • v.25 no.1
    • /
    • pp.155-161
    • /
    • 2016
  • In this study, field experiment, odor simulator, and dispersion modeling were used to evaluate the odor impact from J sewage sludge treatment facility. The height and flow rate of exhaust stack at this facility were 22.3 m and $100Nm^3/min$. The mean odor concentrations of the wet scrubber inlet and exhaust stack were $267{\pm}160$ and $93{\pm}44OU/m^3$, respectively. The odor removal efficiency of wet scrubber showed 65%. The odor simulator is used for the regulated standard calculation of the exhaust pipe(stack). Resulting odor emission rate(OER) by odor simulator was $2.4{\times}10^6(24,000OU/m^3)$. The forecasting result by Screen3 modeling showed that odor exhaust concentration up to $30,000OU/m^3$ was't exceeded maximum allowable emission level on site boundary($15OU/m^3$).

An Investigation of the Effect of Diesel Particulate Filter for Heavy-duty Diesel Engine on Emission Reduction (디젤입자상물질 여과장치의 배기저감성능 효과 분석)

  • Park, Yong-Hee;Shin, Dae-Yewn
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.1 s.94
    • /
    • pp.36-42
    • /
    • 2007
  • Diesel PM can be controlled using Diesel Particulate Filter, which can effectively reduce the level of soot emissions to ambient background levels. In the Heavy Duty Diesel area, the Continuously Regeneration trap has been widely applied in the retrofit market. As the Special act for the improvement of air quality in the capital area, the retrofit program for DPF to used diesel vehicle has progressed favorably and there are currently over 1,000 of these DPF in use in retrofit applications in korea. These DPF comprise a specially formulated Diesel Oxidation Catalyst upstream of a DPF. The $NO_2$ generated by the DOC is used to combust the carbon collected in the DPF at low temperature. To certificate DPF device that is suitable to domestic circumstances, it is necessary to evaluate exactly the DPF devices according to the regulation of DPF certificate test procedure for retrofit(ministry of environment(MOE) announcement NO. 2005-16). To do so the understand of that regulation like the standard of PM reduction rate is needed. In this study the test procedure including test cycle and BPT test condition was examined and also the test result for specific DPF was analyzed. In every test like field test, PM reduction efficiency test and seoul-10 mode test, no defect could be showed.

Evaluation for Contents of Contaminants and Leaching Characteristics of Bottom Ash (바텀애쉬의 유해물질 함량 측정 및 용출특성 평가연구)

  • Koh, Taehoon;Lee, Sungjin;Shin, Minho;Kim, Byongsuk;Lee, Jeakeun;Lee, Taeyoon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.6
    • /
    • pp.77-83
    • /
    • 2010
  • In this study, we tried to determine any detrimental effects on water quality when bottom ash obtained from a coal-fired power plant intended to be used as a fill material in construction sites. Physical-chemical properties of bottom ash were determined using proximate analysis, elemental analysis, XRD, and XRF. Classification of bottom ash as a waste material and soil contamination due to the use of bottom ash were performed by Korea waste standard leaching test and soil toxicity test, respectively. Results of leaching tests were compared to the regulations for water quality and groundwater quality and no harmful effects on water quality were found. Most of heavy metals in leachate were below detection limits but trace amount of $Cr^{6+}$ was found. However, concentration of $Cr^{6+}$ was below the regulation criteria. Column leaching tests indicated that concentrations of Pb and Zn were slightly higher than regulations but below regulations within 1 PVE, but concentrations of sulfate were 10 times higher than regulation and thus, the required time to reach regulation was almost 8 PVE.

Study on Improvement Measures of Green Standard for Energy and Environmental Design for Expansion of Applying Green Roof - Focused on LEED in the USA and BREEAM in the UK - (옥상녹화 적용확대를 위한 녹색건축인증제도 개선방안 연구 - 미국 LEED 및 영국 BREEAM의 비교·분석을 중심으로 -)

  • Kim, Ji-Hyeon;Kwon, Hyuck-Sam;Kim, Jung-Gon;Lee, Bum-Sik
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.2
    • /
    • pp.75-82
    • /
    • 2018
  • Green roof in Korea has been recognized as part of landscape area and local governments enacted municipal ordinance for supporting green roof thereby assisting part of expenses spent for green roof within a range of budget for buildings which are eligible for the green roof support of existing buildings. However, it is necessary to enforce a regulation of mandatory green roof for new buildings in order to expand green roof application and provide a variety of assistances such as subsidy payment, tax relief, and mitigation of floor area ratio-related regulation as done in other advanced nations. In particular, LEED(Leadership in Environmental and Energy Design) in the USA applies additional point directly for green roof in terms of the reduction in heat island effects. For example, the following items are beneficial to have additional points: habitat preservation or restoration, external space, rainwater management, reduction in outdoor water usage, minimum energy performance, and optimum energy performance. In addition, the BREEAM(Building Research Establishment Environmental Assessment Method) in the UK specifies green roof as one of assessment items to be complied in terms of diversity of species. As such, LEED and BREEAM reflect direct and indirect effects of green roof on assessment criteria, which suggest a direction to green building certification criteria in Korea where only additional points are given for green roof according to soil depth.

The History of Transformation of Outdoor Landscape in Apartment Complex - Focused on the Enactment and Revision of laws and Regulations - (아파트 옥외공간의 조경 변천에 관한 연구 - 법규와 법조문의 변화를 중심으로 -)

  • Kim, Dae-Hyun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.6 no.2
    • /
    • pp.39-47
    • /
    • 2003
  • This research traces the history of legislative matters regarding the enactment and revision of laws and regulations related to the outdoor landscape in apartment complex. The years before 1976 can be classified as 'a period of darkness' for the landscape in apartment complex due to absence of landscape legislation. From the year of 1977 when the landscape planting and mere necessities were carried out according to the local administration's building standard to the year of 1990 can be classified as 'a period of quickening'. The year of after 1991 when the enactment of the code#32 called "the green space in site" in the "Korea Building Code" and the "Korea Housing Standard & Regulation" was made, and various construction regulations and provisions were revised in order to improve the scantiness of the apartment complex and its environment should be called 'a period of development'.

Stabilization and solidification of tailings from a traditional gold mine using Portland cement

  • Rachman, Ranno Marlany;Bahri, Ayi Syaeful;Trihadiningrum, Yulinah
    • Environmental Engineering Research
    • /
    • v.23 no.2
    • /
    • pp.189-194
    • /
    • 2018
  • The traditional gold mining in Kulon Progo district, Special Region of Yogyakarta Province produced tailings containing mercury (Hg) from the gold amalgamation process. Mercury accumulated in tailings has 164.19 mg/kg - 383.21 mg/kg in total concentration. Stabilization/solidification (S/S) is one of the remediation technologies to reduce waste pollution. Portland cement is one of the additive materials in S/S that effective encapsulates heavy metal waste. The aim of this research is to know the optimum composition of tailings mixture with Portland cement in S/S process. This research used variation of tailings composition. Variation of Portland cement composition with tailing are 100:0, 90:10, 80:20, 70:30, 60:40, 50:50, 40:60, 30:70, 20:80 and 10:90. The result of this study found that the optimum composition of Portland cement: tailings was 10:90, with compression test of $257ton/m^2$ and TCLP test was 0.0069 mg/L. The compression test results were in accordance to US EPA Standard quality of $35ton/m^2$. TCLP test results meet the standard of Indonesian Government Regulation No. 101 Year 2014 of 0.05 mg/L.

Inward Leakage Test for Particulate Filtering Respirators in Korea (방진마스크의 안면부 누설률에 관한 연구)

  • Han Don-Hee
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.5 s.81
    • /
    • pp.432-439
    • /
    • 2004
  • Korean certification regulation for particulate filtering respirators requires inward leakage (IL) test as European Standards (EN) and the standard levels of regulation are the same as those of EN. This study was conducted to evaluate particulate filtering respirators being commercially used in the market by using IL and assess the characteristics of IL. The study began with discussing the concept of IL, comparison of IL with fit test, and IL measurement method. Three brands of half masks and 10 brands of filtering facepieces (two top class, four 1st class and four 2nd class), total 13 brands respirators, and 10 test panels (subjects) who were classified in 9 facial grids in accordance with face length and lip length, were selected for IL test. IL tests were conducted in the laboratory of 3M Innovation Center which was established by EN standard. As expected ILs of half masks were lower than those of filtering facepiece mask. ILs of half masks and some filtering facepieces were significantly different in manufacturers. ILs of 1st class filtering facepieces were found to be much more than those of 2nd class and thus the result would cause wearers to get confused to select a mask. Four of six brands being no compliance with standards were thought that they should be tested again for certification because of a lot of differences from standards. There were no significant differences among ILs of five exercises. In 6 out of 13 brands lognormal distribution of ILs may be a better fit distribution and in 7 brands both lognormal and normal distributions were rejected. The result indicates that geometric mean may be better than arithmetic mean to establish standard.

Proper Estimating Method for Environmental Preservation Cost in Road Projects (도로공사 환경보전비의 적정 산출 방안)

  • Park, Ji-Sun;Lee, Sea-Hyun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.13 no.2
    • /
    • pp.3-10
    • /
    • 2012
  • The current enforcement regulation of "Construction Technology Management Act" prescribes calculation standard of environmental preservation cost in construction site. According to this standard, environmental preservation cost is calculated by using the quantity-per-unit costing method or applied fixed rate on direct cost. However, when calculated by using the quantity-per-unit costing method it is few items to put in the budget according to standard of construction estimate and in the case of using the fixed rate on direct cost it is not considering various characteristics of the construction site. Therefore, it is needed a improvement plan of estimating method and management system for environmental preservation cost. In this study, it surveyed the actual state of the environmental preservation cost according to magnitude of project, site location, anti-pollution facilities and etc. over 38 road projects. The research reported in this paper environmental preservation cost was variously distributed over construction sites. Thus it needs to estimating method and management system to consider characteristics of construction site for environmental preservation cost.