• Title/Summary/Keyword: Environmental recommended standard concentration

Search Result 47, Processing Time 0.03 seconds

An Analytical Method of Formaldehyde in Exhaust Gases from Industrial Facilities using a HPLC under Isocratic Conditions (Isocratic 조건하에서 HPLC를 이용한 산업시설 배출가스 중 포름 알데하이드 분석)

  • Kim, Jun-Pyo;Park, Seung-Shik;Bae, Min-Suk
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.4
    • /
    • pp.616-624
    • /
    • 2018
  • In this study, a previous DNPH (2,4-dinitrophenylhydrazine) coupled with high performance liquid chromatography (HPLC) method to measure the concentration of formaldehyde in ambient and source environments has been improved. To improve the disadvantage of the previous HPLC method, an appropriate composition ratio of mobile phase (water: acetonitrile (ACN)) was determined and an isocratic analysis was conducted. Furthermore, limit of detection (LOD), limit of quantitation(LOQ), accuracy, and precision were investigated to verify the reliability of the analytical conditions determined. Finally, samples of exhaust gases from five different industrial facilities were applied to HPLC analytial method proposed to determine their formaldehyde concentrations. The appropriate composition ratio of the mobile phase under the isocratic condition was a mixture of water(40%) and ACN(60%). As the volume fraction of the organic solvent ACN increases, retention time of the formaldehyde peak was reduced. Detection time of formaldehyde peak determined using the proposed isocratic method was reduced from 7 minutes(previous HPLC method) to approximately 3 minutes. LOD, LOQ, accuracy, and precision of the formaldehyde determined using standard solutions were 0.787 ppm, 2.507 ppm, 93.1%, and 0.33%, respectively, all of which are within their recommended ranges. Average concentrations of the formaldehyde in five exhaust gases ranged from 0.054 ppm to 1.159 ppm. The lowest concentration (0.054 ppm) was found at samples from waste gas incinerator in a bisphenol-A manufacturing plant. The highest was observed at samples from the absorption process in manufacturing facilities of chemicals including formaldehyde and hexamine. The analytical time of the formaldehyde in ambient air can be shortened by using the isocratic analytical method under appropriate mobile phase conditions.

Application Load Duration Curve for Evaluation of Impaired Watershed at TMDL Unit Watershed in Korea (수질오염총량 단위유역의 유량조건별 수체 손상 평가를 위한 부하지속곡선 적용성 연구)

  • Hwang, Ha-Sun;Yoon, Chun-Gyeong;Kim, Ji-Tae
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.6
    • /
    • pp.903-909
    • /
    • 2010
  • The purpose of this study was evaluated on the applicability of Load Duration Curve Method (LDC Method) using HSPF watershed model and sampling data for efficient TMDLs in Korea. The LDC Method was used for assessment pollutant characteristics in watershed and water quality variation in each water flow level. Load Duration Curve is applied for judge the level of impaired water-body and can be estimated the impaired level by pollutant, such as BOD, T-N, and T-P in this study depending on variation of stream flow. As a result, BOD, T-P was usually exceed the standard value at low flow and dry hydrologic period. Improvement of effluent concentration from WWTP and riparian buffer protection zone are effective to improve the water quality. T-N showed the worst condition at mid-range hydrologic period and moist hydrologic period. Therefore, soil erosion control program and BMPs for non-point source pollution control is effective for recovery the water quality, which can be useful method for management of water quality in the plan of recovery water quality spontaneously. Applicability of LDC Method was evaluated in the Nakbon A watershed. However, we need to consider more detailed and accumulated data set such as accurate GIS data and detail pollution data, and WWTP discharge water quality data for accurate evaluation of watershed. Overall, The LDC Method is adequate for evaluation of watersheds characteristics, and its application is recommended for watershed management and TMDL Implementation.

Residual Analysis of Insecticides (Lambda-cyhalothrin, Lufenuron, Thiamethoxam and Clothianidin) in Pomegranate Using GC-μECD or HPLC-UVD

  • Hem, Lina;Park, Jong-Hyouk;Shim, Jae-Han
    • Korean Journal of Environmental Agriculture
    • /
    • v.29 no.3
    • /
    • pp.257-265
    • /
    • 2010
  • In this study, the residual levels of four insecticidal compounds (lambda-cyhalothrin, lufenuron, thiamethoxam, and clothianidin) were monitored in the pomegranate, in order to assess the risk to consumers posed by the presence of such residues. The insecticides were applied at the recommended dose rates onto pomegranate trees. The samples were then collected at harvesting time after several treatments (two, three, and four treatments). After sample preparation progressed through the clean-up procedure, lufenuron, thiamethoxam, and clothianidin residues were analyzed via a HPCL-UVD, and the lambda-cyhalothrin residue was analyzed via a GC-${\mu}ECD$. The versatility of this method was evidenced by its excellent linearity (>0.9998 to 1) at broad concentration ranges. The mean recoveries evaluated from the untreated sample spiked with two different fortification levels ranged from 72.45 to 113.90%, and the repeatability (as a relative standard deviation) resulted from triplicate recovery tests was in a range from 0.80 to 11.75%. The residues of all insecticides determined from treated pomegranate samples and their LOD levels (lunfenuron, 0.01; lambda-cyhalothrin, 0.005; thiamethoxam, 0.01; clothianidin, 0.02 mg/kg) were much lower than their MRLs (0.5 mg/kg).

An Analysis of Indoor Air Quality and Risk Assessment for One-room Housing around the University in the Post-Corona Era (포스트 코로나 시대의 대학교 주변 원룸형 주택에 대한 실내 공기질 분석 및 위해성 평가)

  • Bao, Wei;Jung, Jaeyoun;Jeong, Insoo
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.24 no.3
    • /
    • pp.23-30
    • /
    • 2022
  • In this study, in order to grasp the current situation of indoor environmental pollution and indoor ventilation in one-room around the university in the post-corona era, we analyzed the experimental data and conducted a questionnaire survey on university students. By analyzing the content, the effects of formaldehyde, dust and other pollution on the human body, which are usually not easily detectable, are digitized and more easily taken into account. Among the experimental results, the concentration of VOC and HCHO, gas pollutants among indoor pollutants, exceeded the recommended criteria of the Ministry of Environment in most studio apartments. Overall, the average CO2 concentration was lower than the Ministry of Environment's maintenance standard (1000ppm), but it was relatively high in summer and winter, and it is believed to be caused by cooling and heating in an enclosed space. The levels of PM2.5 and PM10, particulate pollutants, increased in November and December, and it is believed that ventilation defects due to degradation in external temperature. There was no clear difference between the two types, and there was a very high correlation between PM2.5 and PM10, HCHO and VOC. It was found that temperature was closely correlated with all sources except CO2, and humidity was closely correlated with all sources except PM2.5 and PM10. Health risk assessment was conducted for formaldehyde. The average ECR of studio R2 in May was 3.91E-4, and the ECR figure in September was 3.65E-4, which was very high compared to other residential spaces. The R2 level was calculated as 4 people per 10,000 people in the lifetime risk of cancer of residents, exceeding the allowable risk. R8 also showed higher ECR results than other spaces after R2, especially in October, 2.01E-4, six times higher than R7 measured in October, and 1.87E-4 in July, four times higher than R9.

Inter-comparison of Two Aethalometers for Aerosol Black Carbon Measurements (대기 에어로졸 검댕입자 측정을 위한 두 aethalometer의 상호비교)

  • Jung, Jung-Hoon;Park, Seung-Shik;Yoon, Kwan-Hoon;Cho, Sung-Yong;Kim, Seung-Jai
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.2
    • /
    • pp.201-208
    • /
    • 2011
  • Recently, a real-time, pocket-sized aethalometer (microAeth$^{(R)}$ model AE51) has been developed by Magee Scientific Inc. for measuring the concentration of black carbon in the atmosphere. In this study, two aethalometers, models AE-16 and AE-51, which measure the optical absorption of carbon particles at infrared 880 nm, were operated at time interval of 5-min between January 9 and February 10, 2010 at an urban site of Gwangju, to compare the accuracy of black carbon (BC) concentrations reported from the AE-51 model and to investigate reasonable sampling time of filter media in the AE-51. The air samples in the AE-51 and AE-16 models are collected on T60 (Teflon coated glass fiber) filter media (filter spot area: 0.07 $cm^2$) and quartz fiber roll-tape filter (filter spot area: 1.67 $cm^2$), respectively. Real-time measurement results indicate that when the filters were clean, the AE-51 BC was greater than or similar to the AE-16 BC data. However as the filter spots become darker, the AE-16 BC concentrations were higher than the AE-51 BC data and the difference in the BC concentrations from two AE models becomes gradually increased. Relative error in the AE-51 and AE-16 BC concentrations showed significance difference depending on used time of the filter in the AE-51 model, weather pattern, levels of air pollution, etc, ranging from 11.5% (used time of the filter in AE-51: 1,595 min) to 52.5% (used time of the filter in AE-51: 2,085 min). When considering the used time of one filter ticket in the AE-51 model and difference (or relative error %) between AE-16 and AE-51 BC concentrations, it is recommended that the standard sampling time per one filter ticket within the AE-51 model be less than approximately 24 hr (1,440 min) under the normal weather conditions except for severe haze and mist events.

Analysis on Trends and Major Impact Factors of Water Quality Dynamics in the Gab-Cheon River, Daejeon, Korea (대전 갑천의 수질변화 경향 및 주요 수질 영향 인자 분석)

  • Lee, Gayoung;Seo, Dongil
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.9
    • /
    • pp.517-525
    • /
    • 2015
  • This study analyzes water quality change trends in three major rivers in Daejeon and effect of discharge from Daejeon Wastewater Treatment Plant between 1992 and 2014. As of 2014, COD concentration in the Gab-cheon-A station is in level VI for Korea river water quality standard while BOD and TP are in level III. As expansions of the treatment plant, water quality in the Gab-cheon River has been improving accordingly. However, during the study period, TN concentrations of the headwater and the most downstream locations of the Gab-cheon River have increased about twice and three times, respectively. It was estimated that the treatment plant is responsible for 35%. 46%, 76% and 63% of BOD, COD, TN and TP loadings of the Gab-cheon River, respectively. It was also estimated that small tributaries and nonpoint sources are responsible for 54% and 47% of BOD and COD loadings of the Gab-cheon River. Therefore, it is recommended to further reduce nutrient loadings from the treatment plant and also reduce surface runoff organic loading from nonpoint sources including small tributaries and storm sewers.

The Distribution of Indoor Air Pollutants by the Categories of Public-Use Facilities and Their Rate of Guideline Violation (다중이용시설별 실내공기 오염물질 농도분포 및 기준치 이상 값의 구성비 조사)

  • Joen, Jeong-In;Lee, Hye-Won;Choi, Hyun-Jin;Jeon, Hyung-Jin;Lee, Cheolmin
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.5
    • /
    • pp.398-409
    • /
    • 2021
  • Background: The types and effects of hazardous pollutants in indoor air may vary depending on the characteristics of the sources and pollutants caused by physical and chemical properties of buildings, the influence of outdoor air, and the exposure and use characteristics of residents. Objectives: This study was conducted to provide basic data on the establish of indoor air quality management for different classes of public-use facilities by presenting the characteristics of concentration distribution of hazardous pollutants by different public-use facilities and the status of the excess proportion of exceeding standards. Methods: This study analyzed self-measurement data from public-use facilities taken from 2017 to 2019 A total of 133,525 facilities were surveyed. A total of 10 types of pollutants that have maintenance and recommended standards stipulated in the Indoor Air Quality Control Act from the Ministry of Environment were investigated. The excess proportion and the substances exceeding the criteria for each type of public-use facilities for these pollutants were investigated. Results: As a result of the analysis of the proportion of exceeding the standard for each type of public-use facility, the facilities with the highest excess proportion of the standards for each hazardous pollutant were: PM10 in railway stations (8.93%), PM2.5 in daycare centers (7.36%), CO2 in bus terminals (2.37%), HCHO in postpartum care centers (4.11%), total airborne bacteria in daycare centers (0.69%), CO in museums (0.1%), NO2 in postpartum care centers (1.15%), Rn in museums (0.78%), total volatile organic compounds in postpartum care centers (7.20%) and mold in daycare centers (1.44%). Conclusions: Although uncertainty may arise because this study is a result of self-measurement, it is considered that this study has significance for providing basic data on the establishment in the future of indoor air quality management measures customized for each type of public-use facility.

Measurements of Trimethylamine (TMA) in air by Tedlar bag sampling and SPME analysis (환경대기 중 Trimethylamine (TMA)의 측정: Tedlar bag 방식의 채취와 SPME 분석법의 특성 연구)

  • Kim, K.H.;Hyum, S.H.;Im, M.S.
    • Analytical Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.96-102
    • /
    • 2006
  • Trimethylamine (TMA) is one of the difficult odorous compounds for the collection and analysis. Although sulfuric acid absorption and/or sulfuric acid impregnated filter method are commonly recommended for its sampling, these methods also suffer from difficulties involved in sample treatment and operational procedures. Hence, as an ancillary approach to measure TMA, we investigated the combination of bag sampling and SPME analysis for TMA measurements. For the purpose of our study, we investigated the following three subjects: 1) temporal variability of standard storage, 2) bag loss effect of TMS, and 3) TMA loss due to repetitive analysis of an identical bag sample. According to our storage test up to 7 or 20 dyas, TMA loss were found to occur up to 40 to 50% within relatively short period of up to 48 hrs depending on its concentration ranges. When the tests were made for bag loss by transferring TMA standards across different size bags, we were able to find that the extent of bag loss are not significant with 5 to 20% loss rate. Finally, the TMA sorptive loss via its exposure to SPME fiber was generally estimated to run from 2 to 3%.

Studies on Benzo(a)pyrene of the Suspended Particulate in Atmosphere of Seoul City (서울시(市) 대기중(大氣中) 유해(有害) 부유분진(浮遊粉塵) 성분(成分)에 관(關)한 조사연구(調査硏究) -부유분진중(浮遊粉塵中)의 Benzo(a)pyrene에 관(關)하여-)

  • Kwon, Sook-Pyo;Chung, Yong;Lim, Dong-Koo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.11 no.1
    • /
    • pp.65-75
    • /
    • 1978
  • This study was carried out to investigate air pollution by total suspended particulate(T.S.P.), benzene soluble matter and benzo(a) pyrene in Seoul city. The sampling areas were divided into commercial(Kwang Hwa Moon), indus-trial(Ku Ro Dong) and residensial area(Shin Chon). Sampling was undertaken by High Voulme Air Sampler for four seasons from January 1917 to November 1977. The T.S.P. was extracted with Soxhlet apparatus by benzene and benzo(a) pyrene was separated by column chromatography and thin layer chromatography. The concentrations of benzo(a) pyrene were measured by means of fluorophotometer, and following results were obtained. 1. Arithmetic average concentration for 1-day averaging time of total suspended particulate were $275.6ug/m^3$ in Kwang Hwa Moon, $325.9ug/m^3$ in Ku Ro Dong and $193.0ug/m^3$ in Shin Chon. 2. The seasonal variance of total suspended parti-culate at Ku Ro Dong and Shin Chon were $102.7ug/m^3\;99.6ug/m^3$ respectively and at Kwang Hwa Moon $39.9ug/m^3$. And the concentration of autumn is higher than of that spring at Ku Ro Dong and at Shin Chon, but at Kwang Hwa Moon, the seasonal variance is very little. 3. The concentrations of 50% frequency from geometric mean for 1-day averaging time were $264ug/m^3,\;300ug/m^3\;and\;178ug/m^3$ at Kwang Hwa Moon, Ku Ro Dong and Shin Chon. And geometric standard deviation were 1.27, 1.38 and 1.41 respectively. 4. The concentrations of benzene soluble mater were $26.9ug/m^3$ at Kwang Hwa Moon, $22.7ug/m^3$ at Ku Ro Dong and $15.5ug/m^3$ at Shin Chon, and the ratios to the T.S.P. were 9.8%(range 5.6-14.8%), 7.0%(range 2.4-14.4%) and 8.0%(range 5.5-22.1%) respectively. 5. The concentrations of benzo(a) pyrene were $8.5ug/m^3$ (range $0.8-29.9ug/m^3$) at Kwang Hwa Moon $10.9ug/m^3$(range $1.1-52.0ug/m^3$) at Ku Ro Dong and $5.8ug/m^3$(range $1.5-11.4ug/m^3$) at Shin Chon. 6. The results of this investigation were relatively high in compared with the recommended standards of suspended particulate in air of U.S. Environmental Protection Agency and observed levels of benzo(a)-pyrene in U.S. city.

  • PDF

Relationship between Exposure Concentrations to Methylene Chloride in Air and Carboxyhemoglobin Levels in Blood of Workers Engaged in Blowing, and Cleaning Operations (발포 및 세척 공정 근로자의 공기중 Methylene Chloride 노출 농도와 혈중 Carboxyhemoglobin 수준간의 상관관계에 관한 연구)

  • Shin, Yong Chul;Kim, Yang Ho;Yi, Gwang Yong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.9 no.1
    • /
    • pp.87-98
    • /
    • 1999
  • The objectives of this study were to evaluate exposures to airborne methylene chloride and postshift carboxyhemoglobin (COHb) in blood of workers engaged in processes using blowing or cleaning agents, and to investigate correlation between methylene chloride concentrations and the blood COHb levels of workers. The geometric mean (GM) of workers' exposures (8 hour-time weighted averages, TWA) to airborne methylene chloride during cleaning molds using rags wetted with the solvent in the manufacture of flexible polyurethane foam (GM = 61.4 ppm), during operating the dip tank for cleaning molds in the manufacture of lens (GM = 61.0 ppm), and during cleaning the blowing nozzles by spraying the solvent in the manufacture of shoes (GM = 117.2 ppm) were exceeded the American Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Value ($TLV^{(R)}$)-Time Weighted Average (TWA) (50 ppm). The COHb levels were significantly different among groups (p<0.05). The average COHh levels in blood of non-smoking workers were 2.0% in. low-level (<50 ppm) exposure group, and 3.9 % in high-level (>50ppm) exposure group. The average COHb levels in smoking workers were 3.1% in low-level exposure group, and 4.8% in high-level exposure group. The blood COHb levels of no-exposed workers to methylene chloride were 1.8% in non-smoking group, and 2.8% in smoking group. It was found that the COHb level dependeds on the methylene chloride concentration and smoking habit, and was highly correlated with methylene chloride concentration in air. The correlation coefficient was 0.81 among non-smoking workers. The estimated COHb level (3.6%) and 95% upper confidence limit (4.0%) corresponding to TLV-TWA of methylene chloride exceeded the current ACGIH Biological Exposure Index (COHb 3.5%) for carbon monoxide. The estimated COHb level (5.4%) at 100 ppm exceeded the standard (5%) recommended by National Institute for Occupational Safety and Health (NIOSH) for preventing adverse cardiovascular effect. The estimated COHb value and 95% upper confidence limit at 25 ppm of the Occupational Safety and Health. Adminstration (OSHA) Permissible Exposure Limit-TWA (PEL-TWA) were 2.6% and 3.0%, respectively. It is suggested that COHb in blood be kept below 3.0% to comply with OSHA PEL-TWA.

  • PDF