• Title/Summary/Keyword: Environmental problems

Search Result 5,648, Processing Time 0.032 seconds

Antifouling Effect of an Ultrasonic System Operating at Different Frequencies (주파수 변동에 따른 초음파방오장비의 파울링제거효과)

  • Bae, Jin-Woo;Park, Guan-Sik;Ru, Myung-Lok;Park, Goun-Ha
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.5
    • /
    • pp.609-616
    • /
    • 2019
  • When the fouling of a vessel occurs, its resistance at sea increases and there is a corresponding increase in fuel consumption. The maintenance cost of the vessel also increases because it is time-consuming to remove the fouling. To solve this problem and minimize environmental contamination of sea-water, there have been recent developments in anti-fouling paints as self-polishing copolymers that not include toxic elements such as tin. When these conventional techniques are applied to vessels, polishing is promoted during the operation whereby friction or vibration with seawater occurs. This leads to enhanced anti-fouling performance. However, when fouling is intensified such as during an anchorage, there is no flow of seawater and polishing is suppressed. This leads to a deterioration of the performance of anti-fouling. To solve these problems, we developed a system that induces vibration in a vessel during anchorage. As such, the deterioration of polishing due to insuf icient flow of seawater is inhibited. The reliability of the ultrasonic antifouling system was evaluated by calculating its repeatability. The removal efficiency of fouling of the proposed system was qualitatively evaluated using test specimens. The test revealed that the value of the coefficient of variation for the reproducibility of the frequency and amplitude was 0.2 % and 4.0 % on average. The degree of fouling of the specimens was the highest at 73.3 g in the No.5 sepcimen. Moreover, efficiency of fouling removal was 93.2 % on average compared to the specimens without the proposed system.

The Estimation of Sand Dam Storage using a Watershed Hydrologic Model and Reservoir Routing Method (유역 수문모형과 저수지 추적기법을 연계한 샌드댐 저류량 산정)

  • Chung, Il-Moon;Lee, Jeongwoo;Lee, Jeong Eun;Choi, Jung-Ryel
    • The Journal of Engineering Geology
    • /
    • v.28 no.4
    • /
    • pp.541-552
    • /
    • 2018
  • The implementation of drought measures in the upstream areas of river basins is seldom considered with respect to water supply. However, the demand for such measures is increasing rapidly owing to the occurrence of severe droughts, and interventions on streams and the water supply are needed. Physical interventions are an option to prevent streams from becoming dry and to maintain stream water flow, but dam construction is challenging because of environmental and ecological considerations. Here, a feasibility study was conducted to assess the potential effects of sand dams, which are widely used in arid regions in Africa. The SWAT-K model, which is a hydrologic model used for Korean watersheds, is used to estimate the flow rate of water in an ungauged watershed. The changes in water storage of the sand-dammed reservoir and in downstream flow rates are estimated for two types of sand dam (natural and dredged). The results show that sand dams are capable of increasing the downstream flow rate during normal conditions and of mitigating water supply problems caused by the withdrawal of water during drought periods.

Difference of Gray Mold Severity at Roses Caused by Botrytis cinerea Strains (잿빛곰팡이병원균 Botrytis cinerea 균주 종류별 장미 발병 정도의 차이)

  • Hwang, Kyu-Hyon;Hong, Seung-Min;Lee, Young-Soon;Lee, Hyun-Ju;Seo, Myeong-Whoon
    • Research in Plant Disease
    • /
    • v.25 no.1
    • /
    • pp.16-21
    • /
    • 2019
  • Botrytis cinerea is the pathogen for a gray mold generating problems during the cultivation and transportation of roses. But there is little information about the difference of the symptom severity caused by gray mold on rose varieties and pathogen strains. 16 strains were collected from the rose cultivation area to confirm the degree of disease occurrence against strains and each variety. Collected 16 strains were identified based on the sequences analysis of ITS region of ribosomal DNA by using specific primers. The sequence analysis was performed by comparing the sequences to find a difference. To confirm the difference in disease occurrence for each strains, the difference was classified from 0 to 5 stages using charmant variety as a control. The data was confirmed through Kruskal-Wallis ANOVA. The result showed the significant difference in the pathogenicity caused by strains. WNG6_5 showed the lowest pathogenicity with 0.24 and WNG6_3 showed the highest with 3.20. The difference between two strains were almost 3.0. In addition, nine varieties of roses were more investigated with three strains such as the strains of WNG6_5, Hwa_1, and WNG6_3. The result showed that the Love Letter variety showed resistance and the Ice Bear variety was sensitive to three strains. Taken together, this study showed the significant difference by the interactions of rose varieties and gray mold strains.

Superelevation and Bed Variation Due to Attack Angle of Submerged Vanes in Curved Channel (수제 입사각에 따른 개수로 만곡부의 편수위와 하상변동)

  • Park, Sang Deog;Paik, Joongcheol;Jeon, Woo Sung;Lee, Hyun Jae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.39 no.2
    • /
    • pp.297-306
    • /
    • 2019
  • Since the centrifugal force acts on the flow in the curved channel, a transverse water surface gradient occurs and the thalweg is biased toward the outer bank. The submerged vanes may be used to solve various engineering problems of the curved channels. In order to analyze the influence of an attack angle and the distance between the vane arrays on the river bed variation and the superelevation in a bend, movable bed hydraulic experiments were conducted in a $90^{\circ}$ curved rectangular channel of a small-size gravel bed. Installing the submerged vanes in the bend increases the maximum scour depth. But if vanes are installed in a uniform obtuse angle, the scour depth may be reduced. If the flow rate in the channel bend with vanes equals to the channel forming discharge, the location of the maximum scour depth moved to the downstream and the superelevation increased. However if the flow rate is smaller than that, the location of the maximum scour depth moved upstream and the superelevation decreased. The channel bed change and the superelevation due to the installation of the submerged vanes have been dependent on the interaction of the attack angle, the flow rate, and the distance between the arrays.

Assessment of Groundwater Contamination Vulnerability by Geological Characteristics of Unsaturated Zone (불포화대 지질특성에 따른 지하수오염취약성 평가)

  • Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.28 no.4
    • /
    • pp.727-740
    • /
    • 2018
  • The media in the undersaturated zone is defined as the uppermost layer of the water table at which the groundwater is unsaturated or saturated discontinuously. The properties of the unsaturated zone can affect the reduction of contaminants that flow from the lower part of soil to the water table. In recent, there have been problems in evaluating groundwater contaminations vulnerability because weighted value for permeability is given, regardless of anisotropy and heterogeneity in the unsaturated media. Geological media have various ranges of permeability. When applying the weighted value, representative of permeability for grain sizes standardized, to construction of contamination vulnerability, it will produce more exaggerated result than the case that considers unsaturated geological properties. In this study, we performed laboratory column tests considering two sets of the unsaturated layers in order to investigate the permeability in anisotropic unsaturated zone with anisotropy. On the basis of the tests, average permeability coefficients were calculated considering the properties of unsaturated media obtained from drill cores in the field. The final contamination vulnerability map constructed shows that the contamination vulnerability map applying the properties of geological media of the unsaturated zone coincides much better with the results measured in the field, compared to the case of contamination vulnerability considering the weighted value in the unsaturated zone.

Characteristics of Mine Liner According to the Replacement Ratio of Nano-Silica and Silica-Fume (나노실리카 및 실리카흄 대체율에 따른 차수재의 특성)

  • Kang, Suk-Pyo;Lee, Hee-Ra;Kang, Hye-Ju;Nam, Seong-Young;Kim, Chun-Sik
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.7 no.1
    • /
    • pp.66-73
    • /
    • 2019
  • Approximately 80% of the mines are vacated or abandoned mines and are mostly left without suitable environmental treatment facilities. In the area around the abandoned mine site, problems such as drainage of acidic city drainage and leakage of leachate occur, and ground subsidence caused by this can cause a safety accident due to sink hole occurrence. In this study, flow, compressive strength, water uptake, pore and hydration characteristics were investigated to investigate the basic properties of liner and cover material based on the replacement ratio of nano silica and silica fume in the existing blast - furnace slag fine powder. As a result, as the substitution ratio of nano silica and silica fume increased, the flow and compressive strength of nano silica specimens increased and the absorption rate decreased. In the case of pore characteristics, the amount of pores decreased as the substitution ratio of nano silica and silica fume increased. Especially, the capillary porosity of 10-1,000 nm diameter decreased. Ray diffraction analysis and SEM measurement showed that the peak positions of the hydration products were almost the same when compared with the 5% alternative test samples of Plain and silica fume.

A Study on the Actual Condition and Improvement Plan of the Space for Elementary School Care Classroom (초등돌봄교실 공간 조성 실태 분석 및 개선방안 연구)

  • Cho, Jin-Il;Choi, Hyeong-Ju
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.18 no.1
    • /
    • pp.1-16
    • /
    • 2019
  • The purpose of this study is to diagnose the problems of an elementary school care classroom in terms of facilities and physical environment and to suggest an improvement plan for building safer and more pleasant facilities and environment in further proceeding the policies of a whole-day care classroom. To this end, we analyzed the main contents of the domestic policies for elementary school care classes and the related spatial standards amongst the management plans of provincial education offices nationwide. In addition, we analyzed the relevant care facility standards of advanced countries such as the U.S., Australia, and Singapore and diagnosed the physical environmental level of Korean care classes in comparison to the international standards. Afterwards, we conducted a case study of elementary school care classes in order to examine the key issues with the environment of care classes, the causes of these issues and the user recognition and demand. The key results of this research are as follows. First, it is necessary to elaborate and refine the guidelines on elementary school care classrooms. Second, in order to provide high-quality elementary care services, it is important to have a combined classroom that can be operated at the level equivalent to or similar to a dedicated care classroom. Third, it is necessary to regularly check the facilities and environment of the elementary school care classroom.

Applicability Assessment of Epoxy Resin Reinforced Glass Fiber Composites Through Mechanical Properties in Cryogenic Environment for LNG CCS (에폭시 수지가 적용된 유리섬유 복합재료의 극저온 환경 기계적 특성 분석을 통한 LNG CCS 적용성 평가)

  • Yeom, Dong-Ju;Bang, Seoung-Gil;Jeong, Yeon-Jae;Kim, Hee-Tae;Park, Seong-Bo;Kim, Yong-Tai;Oh, Hoon-Gyu;Lee, Jae-Myung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.58 no.4
    • /
    • pp.262-270
    • /
    • 2021
  • Consumption of Liquefied Natural Gas (LNG) has increased due to environmental pollution; therefore, the need for LNG carriers can efficiently transport large quantities of LNG, is increased. In various types of LNG Cargo Containment System (CCS), Membrane-type MARK-III composed of composite materials is generally employed in the construction of an LNG carrier. Among composite materials in a Mark-III system, glass-fiber composites act as a secondary barrier to prevent the inner hull structure from leakage of LNG when the primary barrier is damaged. Nevertheless, several cases of damage to the secondary barriers have been reported and if damage occurs, LNG can flow into the inner hull structure, causing a brittle fracture. To prevent those problems, this study conducted the applicability assessment of composite material manufactured by bonding glass-fiber and aluminum with epoxy resin and increasing layer from three-ply (triplex) to five-ply (pentaplex). Tensile tests were performed in five temperature points (25, -20, -70, -120, and -170℃) considering temperature gradient in CCS. Scanning Electron Microscopy (SEM) and Coefficient of Thermal Expansion (CTE) analyses were carried out to evaluate the microstructure and thermos-mechanical properties of the pentaplex. The results showed epoxy resin and increasing layer number contributed to improving the mechanical properties over the whole temperature range.

Optimization of Electrolytic Oxidant OCl- Production for Malodorous VOCs Removal (악취성 VOCs 제거를 위한 전해 산화제 OCl-의 생산 최적화)

  • Yang, Woo Young;Lee, Tae Ho;Ryu, Hee Wook
    • Clean Technology
    • /
    • v.27 no.2
    • /
    • pp.152-159
    • /
    • 2021
  • Volatile organic compounds (VOCs) occur in indoor and outdoor industrial and urban areas and cause environmental problems. Malodorous VOCs, along with aesthetic discomfort, can have a serious effect on the human body. Compared with the existing method of reducing malodorous VOCs, a wet scrubbing method using an electrolytic oxidant has the advantage of reducing pollutants and regenerating oxidants. This study investigated the optimal conditions for producing OCl-, a chlorine-oxidant. Experiments were conducted by changing the type of anode and cathode electrode, the type of electrolyte, the concentration of electrolytes, and the current density. With Ti/IrO2 as the anode electrode and Ti as the cathode electrode, OClproduction was highest and most stable. Although OCl- production was similar with the use of KCl or NaCl, NaCl is preferable because it is cheap and easy to obtain. The effect of NaCl concentration and current density was examined, and the OCl- production rate and concentration were highest at 0.75 M NaCl and 0.03 A cm-2. However, considering the cost of electric power, OCl- production under the conditions of 1.00 M NaCl and 0.01 A cm-2 was most effective among the conditions examined. It is desirable to produce OCl- by adjusting the current density in accordance with the concentration and characteristics of pollutants.

The Foundation Performance of Selected Waste Plastic Wastes Used in Cement Manufacturing (시멘트 제조에 사용되는 선별된 폐플라스틱 폐기물류 원료로서의 기초 특성 평가)

  • Han, Jong-Min;Kang, Bong-Hee;Park, Jae-Yong;Lee, Jeong-Wook;Kim, Nam-Gyu
    • Resources Recycling
    • /
    • v.29 no.6
    • /
    • pp.88-97
    • /
    • 2020
  • In this study, the selected waste plastic waste logistics used for cement sintering were classified into two types through the process of sorting and crushing, analyzing the characteristics of each, and analyzing the correlation of the strength after cement manufacturing. The experimental variables were classified into soft and hard waste plastic waste, and the correlations between calorific value, chlorine, and moisture were analyzed. In addition, some of each waste was selected and melted, and the basic characteristics were evaluated by analyzing the structure and calorific value. The results of the experiment showed that it was evaluated that it is suitable to obtain a heat source by separating soft waste plastic wastes and sintering them with materials having similar properties. As a result of examining the wastes by strength after cement manufacturing, it was analyzed that the use of hard plastics greatly contributes to the compressive strength on the 1st and 28th, and the use of soft plastics contributes to the compressive strength on the 28th. However, these characteristics are evaluated by collecting only a part of the waste, and since the deviation of the waste occurs, continuous management is required, and a follow-up study on the environmental problems caused by the use of waste is required.