• 제목/요약/키워드: Environmental illumination

검색결과 238건 처리시간 0.019초

야간 고등학교의 환경위생학적 조사 -조명을 중심으로- (The Study on Envronmental Sanitation for Night High School. -Illuminate-)

  • 김난천;오석흔
    • 한국환경보건학회지
    • /
    • 제5권1호
    • /
    • pp.40-45
    • /
    • 1978
  • We have selected 36 schools of a total of night high schools for boys and girls in seoul and measured intensity of illumination of the classroom, The corridors and the stairs that students study and live, with priority given to an illumination, a primary factor of environmental sanitation of school following is the result. 1. The maximum average intensity of illumination of the classroom is 93.2 Lux, and the minimum average intensity of illumination 39.5 Lux. Mean$\pm$S, is 59.03$\pm$22.8 Lux 2. The maximum average intensity of illumination of the corridor is 39.2 Lux, and the minimum average intensity of illumination 11.1 Lux. 3. The maximum average intensity of illumination of the stair is 11.58 Lux, and the minimum average intensity, of illumination 4.92 Lux, mean$\pm$S.D is 7.88$\pm$10.0Lux. 4. Schools with tile illumination facilities more than 50 Lux are 63.8% and less than 50 Lux are 36.2%. 5. Schools with 9-11 facilities of a source of light per classroom by a fluorescent lamp are the most as 30.50%. 6. As for the corridor, schools with the illumination equipment less than 10 Lux are 27.8%, are more than 10 Lux 72.2% 7. As for the stairs schools with the illumination equipment less than 10 Lux are 77.8%, and more than 10 Lux 10 Lux 22.2%.

  • PDF

Electro-Luminescent Display(ELD) Systems for the Cave Illumination

  • Oh, Jong-Woo
    • 동굴
    • /
    • 제85호
    • /
    • pp.1-14
    • /
    • 2008
  • Electroluminescent Display(ELD) will be the innovative ideas to replace existed electricity illumination systems that consider to under effectiveness and environmental pollution generators in the commercial caves because ELD has less heat and low electricity consumption by the new illumination materials. Characteristics of the ELD are as following: it is a proper matter for the small merchandise ads due to its thickness is only below 3oo micoron, electricity consumption of ELD is less (1/3) than LED, ELD that is a whole face illumination system is much brighter than LED that is a dot illumination system, ELD is longer life than others due to its less light generation systems, ELD is any problems to bend, and it is a best device to use a light board ads. ELD has advantages on conservation of cave biosystems and reduce pollution when ELD is installed in touring spots and emergency corridors of weak illuminated cave internal areas by less heating and low electricity consumption using the indirect illumination of the ELD. Therefore when the high technologic ELD is installed in the commercial caves in Korea, it will be innovating cave environmental systems, saving budgets, and increasing tours.

교량의 경관조명연출디자인 평가항목 도출에 관한 연구 (A Study of the Selection of the Valuation Items of the Environmental Illumination Design for a Bridge)

  • 조현철
    • 조명전기설비학회논문지
    • /
    • 제18권6호
    • /
    • pp.22-30
    • /
    • 2004
  • 도시 공간에서의 교량경관 조명연출의 목적은 교량과 주변의 수변 공간을 아름답게 연출할 뿐만 아니라 사람과 자동차에 대하여 안전성 및 쾌적성을 확보함과 동시에 야간경관의 심미적 공간을 연출한다. 또한 환경과의 조화, 그리고 지역의 문화성, 역사성, 상징성과 융합하여 도시의 새로운 아이덴티티를 창출하기 위한 것으로서, 관광자원으로서의 부가가치를 높일 수 있으므로 최근에는 정부가 적극적으로 교량 경관조명을 활성화시키고 있으나 매뉴얼화 된 디자인과 설계기준의 부재로 교량의 예술적, 문화적 품위가 저하되고 있는 실정이므로 조속히 우리풍토에 적합한 교량 경관조명의 설계지침과 평가방법 등 이 확립되어야 하겠다. 이러한 이유로 본 연구에서는 도시미관을 향상시키기에 최적의 장소로 여겨지고 있는 한강의 교량 중 조명시설이 설치된 교량을 평가 대상으로 채택하여, 문헌고찰과 설문조사를 중심으로 예비평가항목 구성단계 및 전문가 검증 단계를 거쳐, 평가항목별 상관분석 및 인자분석 결과, 평가항목을 인자해석에 의해 중요변인으로 하고 분산 분석과 평균값 비교를 통해 중요 항목과 일반항목으로 구분하였고, 이를 바탕으로 전문적이고 표준화된 평가를 유도할 수 있는 교량형식별 경관조명의 평가항목을 도출하였다.

도시근린공원의 야간조도분포의 특성 (Characteristics of th Distribution of Night Illumination Level at Urban Neighborhood Parks)

  • 최연철;김진선
    • 한국조경학회지
    • /
    • 제28권4호
    • /
    • pp.66-74
    • /
    • 2000
  • The purpose of this study is to research and analyze the distribution of night illumination level at urban neighborhood parks and to show its characteristics. And this is used basic data ensuring safety and satisfying aesthetic and psychological desires of people who use urban neighborhood parks at night. To research and analyze the distribution of illumination level at urban neighborhood parks at night. To research and analyze the distribution of illumination level at urban neighborhood parks, I selected 8 urban neighborhood parks as the subject of research in this study, set the measuring standard of illumination level, and measured the illumination level by the measuring standard. The results of this study are as follows; 1. Currently, total average illumination level of urban neighborhood parks was lower than the minimum standard of illumination level I KS A 3011-1993. 2. Average illumination level of each place in urban neighborhood parks appeared variously from low level to high level. But this was lower than the minimum standard illumination level in KS A3011-1993 like total average illumination level. 3. The higher was total average illumination level of urban neighborhood parks, the more various was brightness of places. Although users' aesthetic and mental desire or behavioral aspect relate with safety cannot be found by only survey and analyses of illumination level, it is judged that first, illumination level of the standard of the lightness should be analyzed to find user's mental states and behaviors in external space at night. Therefore, it is considered that this study, which analyzed characteristics illumination level as basic data, has a significance. The study continuing for other illuminative environmental factors suitable in the place is required because the brightness of places may not be measured by only illumination level. And the proper illumination level in outdoor places should be showed in considering psychological and behavioral aspects of human as people may have their own sense of brightness.

  • PDF

ILLUMINATION ADUSTMENT FOR BRIDGE COATING IMAGES USING BEMD-MORPHOLOGY APPROACH

  • Po-Han Chen;Ya-Ching Yang;Luh-Maan Chang
    • 국제학술발표논문집
    • /
    • The 3th International Conference on Construction Engineering and Project Management
    • /
    • pp.224-229
    • /
    • 2009
  • Digital image recognition has been used for steel bridge surface assessment since late 1990s. However, the non-uniform illumination problems such as shades, shadows, and highlights are still challenges in image processing to date. Therefore, this paper develops a new approach to tackle the non-uniform illumination problem for rust image adjustment. The inhomogeneous illumination problem is divided into shades/shadows and highlights in this paper. The proposed BEMD-morphology approach (BMA) utilizes the bidimensional empirical mode decomposition to mitigate the shade/shadow effect, and the morphological processing to detect and replace the highlight area. Finally, the rust image processed with the BMA will be segmented by the K-Means algorithm, one of the most popular and effective methods, to show the effectiveness of illumination adjustment.

  • PDF

온달동굴의 환경보존과 전기절약의 관리 방안 (Environmental save of the Ondal cave and the management plan of an electric saving)

  • 윤정모
    • 동굴
    • /
    • 제88호
    • /
    • pp.26-30
    • /
    • 2008
  • The black pollution that was able to include green pollution to appear for the intensity of light by an illumination institution is what after all I cannot ignore, and it may be said that chase thing damage by the isolation action that is white pollution done a long story in this outside a certain range by air quality change, dried present situation is really the environmental disruption by development and a damage phenomenon. If I am replaced in winker and I install a sensor light in the outlet by addition and use the electricity illumination that I installed for a tourist in the cave, it is expected that I can be available all the time that it is possible for electricity reduction more than the present and watches tourist passage plan private business Electric illumination in the cave for the environmental save in the cave because it is possible for more electricity reduction to be particularly off-season than on-season.

노인가정의 낙상사고 위험 환경요인 (Home Environmental Hazards of Falling Accident in the Elderly)

  • 박영혜;문정순
    • 보건교육건강증진학회지
    • /
    • 제22권4호
    • /
    • pp.203-213
    • /
    • 2005
  • Purpose: To assess the environmental hazards of falling accident in the homes of the elderly. Method: 222 homes of the elderly were assessed by the home environmental Checklist from May to July in 2003. Results: The mean score of home environmental hazards for fall were 13.19 with the highest score being 49, ranging from 4 to 24. The bathroom was the most hazardous place in the home, porch came next bedroom, kitchen, living room and stair followed them. The floor surface such as finishes and non-skid mats was the most hazardous interior factor in the home, using bathroom came next furniture and illumination followed them. The floor surface such as finishes and non-skid mats in the bathroom, kitchen, living room and porch, illumination of bedroom and stair were the most prevalent hazards in the home of interior. Of the 49 potential hazards, bathroom grab bar was the most prevalent one with 89.9%, and non-skid rugs in the porch, bathroom and kitchen, safety of dinner table, the threshold and furniture of porch, and illumination of bedroom were prevalent more than half of the home under assessing. Men, living in the separate house or villa with stairs were in more hazardous environments. Conclusion: To reduce the potential hazards of fall accident in the home, improving hazards relating to floor surface such as slip resistance surface and mats is important specially those of the separate house or villa with stairs.

서울지역 학교 교실의 실내환경 조사연구 (A Study on the Indoor Environment of school classrooms in Seoul area)

  • 최한영
    • 환경위생공학
    • /
    • 제18권2호
    • /
    • pp.67-74
    • /
    • 2003
  • In 15 schools where were chosen each location (East, West, South, North, Central) of Seoul area, 9 items were measured such as thermo circumstance(temperature, relative humidity, air current, intensity of illumination) particulate matter, carbon monoxide, sulfur dioxide, and nitrogen dioxide being based on the school indoor environment standard. It was showed that indoor temperature, relative humidity and air movement were suitable in comparison with school indoor environment standard. Intensity of illumination was suitable in comparison with all schools, only exception 2 schools. In all investigated schools were adequate for carbon monoxide, sulfur dioxide and nitrogen dioxide, in which each indoor environment standard (10ppw, 0.25ppm/hr, 0.15ppm/hr), but in 5 schools the carbon dioxide were exceeded for standard limit 1,000ppm of Korea. Indoor concentration of dust(PM-10) induced from respiration dust the standard of Korea ($150{\mu}g/m^3$) at all schools.

Impact of Artificial Illumlination on Zooplankton Dynamics

  • Kim, Saywa;Park, Chul-Won
    • 환경생물
    • /
    • 제20권4호
    • /
    • pp.312-315
    • /
    • 2002
  • Impact of artificial illumination on zooplankton dynamics has been studied in Tongyong marine ranch during the period from August 1998 to August 1999. Monthly sampling has been carried out to collect zooplankters from both natural waters and artificially illuminated waters at night. A total of 48 taxa of zooplankton occurred during the study. Copepods showed the prosperity in species number with 21 species. Every sample from illuminated waters consisted of move than 15 species except February while less than 15 species in samples from natural waters during the winter. Benthic amphipods occurred abundantly in illuminated waters. Zooplankton abundance was revealed to be increased in illuminated waters mainly due to the gathering of amphipods (4,500 indiv. $m^{-3})$ in September and October. Twenty times of zooplankton abundance was recorded in illuminated waters when compared with that in natural ones in September due to the gathering: of amphipods and ten times by the explosion of N. scintillans in August 1999. However, no distinct difference in the abundance was observed between two waters in the winter. Zooplankton gathering with artificial illumination seemed to be effective in amphipods, while copepods were hardly affected by the artificial illumination at night.