• Title/Summary/Keyword: Environmental control systems

Search Result 1,224, Processing Time 0.163 seconds

Study on the Differences of Managing to Environmental Issues of Firms between Korea and U.S. (한국과 미국 기업간 환경관리 실천차이에 관한 연구)

  • Jeong, Heon-Bae;Lee, Il-Han
    • International Commerce and Information Review
    • /
    • v.8 no.2
    • /
    • pp.275-296
    • /
    • 2006
  • Environmental management systems offer a set of management tools and principles that can help integrate environmental concerns into daily business practices. Such systems have been in existence since the 1980's. This research identifies the firm's implementation of environmental management that is the most and least popular for managing the environmental management such as 3R's, EM, EMS, environmental awareness. This article investigates the differences of managing to environmental issues of firms between Korea and U.S. The research results suggest that the U.S. firms control of 3R's, EM and EMS better than Korea's, while Korean firms have higher environmental awareness than U.S. firms.

  • PDF

Development of Robust Embedded Measurement System by Using PXI Bus (PXI 버스를 이용한 강인한 범용계측시스템 개발)

  • 유제택
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.2
    • /
    • pp.171-177
    • /
    • 2004
  • Many instrumentations have been used to acquire the performance data of military systems fer many years. But they could not satisfy environmental specifications(vibration, shock, temperature) and processing speed to apply for the performance test of military systems because of having developed as common vehicles/fixed installation equipments. Thus a new rugged embedded measurement system is required to process large data in high processing speed(Maximum sample rate:1.25Mhz/ch) with rugged environmental specifications. We have developed embedded measurement systems by using PXI(PCI extension for Instrumentation)bus interface composed of a stand alone controller and versatile data acquisition boards(analog, digital, vision, temperature and small signal conditioner) on PC-based environment to solve these problems. Operation programs have been developed using Lab_View and the performances have been validated experimentally.

Development of a full-scale magnetorheological damper model for open-loop cable vibration control

  • Zhang, Ru;Ni, Yi-Qing;Duan, Yuanfeng;Ko, Jan-Ming
    • Smart Structures and Systems
    • /
    • v.23 no.6
    • /
    • pp.553-564
    • /
    • 2019
  • Modeling of magnetorheological (MR) dampers for cable vibration control to facilitate the design of even more effective and economical systems is still a challenging task. In this study, a parameter-adaptive three-element model is first established for a full-scale MR damper based on laboratory tests. The parameters of the model are represented by a set of empirical formulae in terms of displacement amplitude, voltage input, and excitation frequency. The model is then incorporated into the governing equation of cable-damper system for investigation of open-loop vibration control of stay cables in a cable-stayed bridge. The concept of optimal voltage/current input achieving the maximum damping for the system is put forward and verified. Multi-mode suboptimal and Single-mode optimal open-loop control method is then developed. Important conclusions are drawn on application issues and unique characteristics of open-loop cable vibration control using MR dampers.

Comparison of discharging electrodes for the electrostatic precipitator as an air filtration system in air handling units (에어핸들링 유닛의 공기정화용 전기집진기의 방전극 비교)

  • Shin, Dongho;Woo, Chang Gyu;Kim, Hak-Joon;Kim, Yong-Jin;Han, Bangwoo
    • Particle and aerosol research
    • /
    • v.13 no.1
    • /
    • pp.11-16
    • /
    • 2017
  • Indoor air quality is of increasing concern because it is closely related human health. An air handling unit (AHU) can be used to control the indoor air quality related to particulate matters and $CO_2$ as well as air conditioning such as temperature and humidity of indoor air. An electrostatic precipitator has a high collection efficiency and low pressure drop, however, ozone can possibly generate from its chargers, which is one of drawbacks to apply it for indoor air control. Here we compared four charging electrodes such as a $50{\mu}m$ tungsten wire, a $100{\mu}m$ tungsten wire, a $16{\mu}m$-thickness Al foil and a carbon fabric comprised of $5-10{\mu}m$ fibers. The carbon fabric electrode showed a superior particle collection efficiency and a lower ozone generation at a given power consumption compared to tungsten wires of 50, $100{\mu}m$ and an Al foil electrode. This low ozone generating, micro-sized electrode can be applied to the electrostatic precipitator in AHU for indoor air control.

Membrane fouling control in low pressure membranes: A review on pretreatment techniques for fouling abatement

  • Arhin, Samuel Gyebi;Banadda, Noble;Komakech, Allan John;Kabenge, Isa;Wanyama, Joshua
    • Environmental Engineering Research
    • /
    • v.21 no.2
    • /
    • pp.109-120
    • /
    • 2016
  • Conventional treatment techniques cannot meet the stringent modern water quality regulations emanating from the need to provide high quality drinking water. Therefore, a number of studies have suggested low pressure membrane filtration as a worthwhile alternative. However, a major constraint to the extensive use of this technology in low and middle income countries is the high operating and maintenance costs caused by the inherent predisposition to membrane fouling. Notwithstanding, pretreatment of feed water using techniques such as coagulation, adsorption, oxidation and bio-filtration is believed to control fouling. In this review paper, the existing scientific knowledge on membrane fouling and pretreatment techniques for controlling fouling in low pressure membranes is analyzed with the aim of providing new and valuable insights into such techniques, as well as unveiling crucial issues noteworthy for further studies. Among the techniques reviewed, coagulation was observed to be the most cost-effective and will remain the most dominant in the coming years. Although oxidants and magnetic ion exchange resins can also control fouling, the propensity of oxidants to form health treating precursors and the high economic implications of magnetic ion exchange resins will hinder their adoption in developing countries.

THE INTEGRATION OF COMPONENTS OF FIRE TECHNOLOGY

  • Marchant, Eric W.
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.11-18
    • /
    • 1997
  • Fire safety systems in large buildings are likely to be complex and may be designed independently of other systems. This means that the interactions and interfaces between the fire safety systems and between the environmental control systems and the fire safety systems may not be carried out properly. Many large, recent buildings have many technological component systems that are used for the control of the environment within the building. Because of the "special" nature of the fire safety systems there is little consideration is given to the possibility systems with a dual function. However, many of the functions of fire safety systems are extensions of systems that provide the day to day control over the internal environment. The present world-wide trend towards the establishment of performance codes, and regulations, will enable the functional design of all systems and thereby allow closer integration of the "ordinary" and "special" systems. Some aspects of the functional and performance characteristics of systems in buildings are introduced and discussed. Special reference is made to the contributions of the systems to the minimisation of fire damage.e minimisation of fire damage.

  • PDF

Motion predictive control for DPS using predicted drifted ship position based on deep learning and replay buffer

  • Lee, Daesoo;Lee, Seung Jae
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.12 no.1
    • /
    • pp.768-783
    • /
    • 2020
  • Typically, a Dynamic Positioning System (DPS) uses a PID feed-back system, and it often adopts a wind feed-forward system because of its easier implementation than a feed-forward system based on current or wave. But, because a ship's drifting motion is caused by wind, current, and wave drift loads, all three environmental loads should be considered. In this study, a motion predictive control for the PID feedback system of the DPS is proposed, which considers the three environmental loads by utilizing predicted drifted ship positions in the future since it contains information about the three environmental loads from the moment to the future. The prediction accuracy for the future drifted ship position is ensured by adopting deep learning algorithms and a replay buffer. Finally, it is shown that the proposed motion predictive system results in better station-keeping performance than the wind feed-forward system.

Numerical and experimental investigation of control performance of active mass damper system to high-rise building in use

  • Park, S.J.;Lee, J.;Jung, H.J.;Jang, D.D.;Kim, S.D.
    • Wind and Structures
    • /
    • v.12 no.4
    • /
    • pp.313-332
    • /
    • 2009
  • This paper numerically and experimentally investigates the control performance of the active mass damper (AMD) systems in a 26-story high-rise building in use. This is the first full-scale application of the AMD system for suppressing the wind-induced vibration of a building structure in Korea. In addition, the AMD system was installed on top of the building already in use, which may be the world's first implementation case. In order to simultaneously mitigate the transverse-torsional coupled vibration of the building, two AMD systems were applied. Moreover, the H-infinity control algorithm has been developed to utilize the maximum capacity of the AMD system. From the results of numerical simulation using the wind load obtained from the wind tunnel tests, it was found that the maximum acceleration responses of the building were reduced significantly. Moreover, the control performance of the installed AMD system was examined by carrying out the free and forced vibration tests. The acceleration responses on top of the building in the controlled case measured under strong wind loads were compared with those in the uncontrolled case numerically simulated by using the wind load deduced from the measured data and a structural model of the building. It is demonstrated that the AMD system shows good control performance in reducing the building accelerations.

Integration of health monitoring and vibration control for smart building structures with time-varying structural parameters and unknown excitations

  • Xu, Y.L.;Huang, Q.;Xia, Y.;Liu, H.J.
    • Smart Structures and Systems
    • /
    • v.15 no.3
    • /
    • pp.807-830
    • /
    • 2015
  • When a building structure requires both health monitoring system and vibration control system, integrating the two systems together will be cost-effective and beneficial for creating a smart building structure with its own sensors (nervous system), processors (brain system), and actuators (muscular system). This paper presents a real-time integrated procedure to demonstrate how health monitoring and vibration control can be integrated in real time to accurately identify time-varying structural parameters and unknown excitations on one hand, and to optimally mitigate excessive vibration of the building structure on the other hand. The basic equations for the identification of time-varying structural parameters and unknown excitations of a semi-active damper-controlled building structure are first presented. The basic equations for semi-active vibration control of the building structure with time-varying structural parameters and unknown excitations are then put forward. The numerical algorithm is finally followed to show how the identification and the control can be performed simultaneously. The results from the numerical investigation of an example building demonstrate that the proposed method is feasible and accurate.