• 제목/요약/키워드: Environmental Vibration Test

검색결과 317건 처리시간 0.029초

과학기술위성 2호 태양전지판의 환경시험 규격에 대한 고찰 (Analysis on Environmental Test Specifications for Solar Panels of STSAT-2)

  • 장태성;김홍배;우성현;이상현;남명룡
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.957-961
    • /
    • 2005
  • A satellite component must withstand vibration caused when launch vehicle acoustics and engine rumble transfer to it through its structural mount. Components shall be subjected to environmental tests after manufacturing process thus the environmental test conditions are needed for component level test including vibration and shock. This paper deals with derivation of component-level environmental test specifications, especially for solar panels of STSAT-2(Science & Technology SATellite-2). Sine sweep random vibration, and shock test conditions were generated for solar panels by assuming the satellite as single-degree-of-freedom system with a base excitation.

  • PDF

기계류부품의 가진시험 조건에 관한 연구 (Study of Vibration Test Condition for Machinery Component)

  • 김형의;박종원;정동수;강보식
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제6권1호
    • /
    • pp.27-36
    • /
    • 2006
  • It is increasingly important to ensure that a given vibration test specification of a particular machinery component is appropriately established by considering its real environmental conditions. Vibration test standards for electrical components are well documented, for example in an IEC 60068 series, while standards for machinery components are rarely found except a few military standards. Thus many vibration tests are performed based on the military standards. However, a test based on these military standards often results in over-testing, and under-testing in some cases due to the different environmental conditions. Also, these standards require an appropriate tailoring that may not be easily accomplished. In this paper, various international and military standards are compared and investigated to obtain test specifications relevant for machinery components. Also appropriate tailoring methods are demonstrated through a case study.

  • PDF

환경진동시험 제어에서 반공진 진동수해석에 의한 치구의 구조변경설계 (Structural Dynamic Modification of Fixture by Antiresonance Frequency Analysis in Environmental Vibration Test Control)

  • 김준엽;정의봉
    • 소음진동
    • /
    • 제5권4호
    • /
    • pp.555-563
    • /
    • 1995
  • This paper proposes the method of antiresonance frequency analysis of multi-input multi-output system. The structural dynamic modification techniques by antiresonance frequency analysis are also applied to reduce the undertest at specimen attachment points on the fixture in environmental vibration test, which is resulted from the inconsistency of antiresonance frequencies at any specified points. Several computer simulations show that the proposed method can remove the undertest problem which is not removed in conventional vibration test control. And the effectiveness of the method is verified with the impact hammer excitation of aluminium fixture model.

  • PDF

Technetium-99m hand perfusion scintigraphy (Raynaud's scan) as a method of verification in hand arm vibration syndrome: a review

  • Taewoong Ha;Hyeoncheol Oh;Jungwon Kim
    • Annals of Occupational and Environmental Medicine
    • /
    • 제34권
    • /
    • pp.26.1-26.13
    • /
    • 2022
  • It is important to assess the blood flow of fingers in the verification of hand-arm vibration syndrome. In the Republic of Korea, most assessments of the blood flow in the fingers are performed using a cold provocation test with finger skin color change. However, this test is a non-objective method with a relatively low sensitivity, leading to possible social and legal problems. Thus, we reviewed the characteristics of several tests that assess the blood flow in the fingers. Among these tests, using the radioactive isotope method, Raynaud's scan has a relatively higher sensitivity and specificity than other tests, provides objective results, and is approachable in many hospitals. So we suggest using Raynaud's scan as an alternative test when cold provocation test with finger skin color change is negative in vibration exposed worker.

환경진동시험제어를 위한 치구의 실험적 구조변경 설계 (Experimental Structural Dynamic Modification of Fixture for Environmental Vibration Test Control)

  • 김준엽;정의봉
    • 소음진동
    • /
    • 제6권3호
    • /
    • pp.317-323
    • /
    • 1996
  • This paper proposes the method of experimental structural dynamic modification of fixture for environmental vibration test control. This method can predict the responses at any points on the fixture utilizing the experimental data, and structural dynamic modification of fixture is made using the predicted responses for the spectra at the specimen attachment points to meet the specified reference spectrum. From the results of controlling the fixture before and after modification by conventional control method and optimal reference spectrum, which has been previously reported by the authors, the proposed method is shown to be an effective one.

  • PDF

진동 시험 기법의 적용에 관한 고찰 (A Study on Application of Vibration Testing Method)

  • 이창훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.587-591
    • /
    • 2012
  • Review of practical vibration test methods those applied in various industrial fields - such as automotive industry, electrics and electronics industry, defense industry and aerospace industry - is described on this paper. Swept sine test, random vibration test and advanced vibration techniques are explained according to their parametric values and also application fields of each test method are suggested by the characteristic of each method. For more proper application of each test method, standardized test specifications should be always reviewed and revised according to the transition of environmental factors.

  • PDF

저궤도 지구관측위성의 광학탑재체 지지구조물 동환경시험 결과분석 (Dynamic Test Results Assessment on the Optical Bench of LEO Satellite)

  • 김경원;김진희;이주훈;김선원;진익민;박종성
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.242-245
    • /
    • 2006
  • This paper is an assessment on the dynamic test results of optical bench for LEO satellite. According to the design requirements, optical bench was designed and manufactured. Dynamic test was performed to verify stability of optical bench. Low level random vibration test, sine burst test and sine vibration test are carried out to identify dynamic characteristics and to verify static strength and safety under quasi-static load conditions. From the result it can be stated that the optical bench is well qualified under the launch environmental conditions.

  • PDF

궤도차량 탑재장비의 진동 내구성 평가를 위한 시험수준 결정방법 연구 (Determining Vibration Qualification Level for the Equipment Loaded Inside a Tracked Vehicle)

  • 최창하
    • 환경영향평가
    • /
    • 제4권2호
    • /
    • pp.123-130
    • /
    • 1995
  • The equipment composed of many complicated electronic stuffs undergoes diverse stresses caused by mechanical vibrations during its service. Thus, to ensure its proper operation in the field a simulated vibration test has to be carried out in the laboratory with the Vibration Qualification Level, the test specification, which can include the real environment. In this paper we intent to deal with method and procedure for determining the Vibration Qualification Level so as to estimate the vibration-endurance for the equipment precisely.

  • PDF

이중 전동식 진동 시험기를 이용한 무인 비행체의 비행진동 환경시험 연구 (A Study On Flight Vibration Environmental Test of Unmanned Aerial Vehicle using Dual Electric Vibration Exciters)

  • 최장섭;오동호
    • 한국군사과학기술학회지
    • /
    • 제26권3호
    • /
    • pp.252-261
    • /
    • 2023
  • Analysis of dynamic characteristics and flight vibration test for unmanned aerial vehicles was studied by using dummy test body. The FEM model for dummy test body was supplemented by results of modal and random vibration test. The free end boundary condition to simulate flight environments was made by test setup using bungee cable. Prior to the flight vibration test using a dual electric vibration exciters, the test procedure to calculate quantitative vibration level was studied by using military specification. The actual test was successfully done by using the analysis and pretest results. From the analysis results, it was possible to determine the feasibility of the test by predicting the excitation force of the flight vibration test and to get the response of any point which could not be measured by the test. The results of this study will much contribute to the Test and Evaluation of unmanned aerial vehicles.

토목 발파가 소음, 진동, 부유 분진에 미치는 영향 (Effects of Civil Blasting on Noise, Vibration and Total Suspended Particles)

  • 정진도;정영국
    • 한국환경과학회지
    • /
    • 제13권1호
    • /
    • pp.99-107
    • /
    • 2004
  • This research is to determine the level of environmental pollution at a blasting construction area which is the origin of noise, vibration, and suspended particle, and to compare the results with other domestic and international standard data. This experiment is also to find out the effects resulting from blasting construction and to propose a plan that can decrease environmental pollution. The blasting construction area is a factory site which is about one and half million square meter and sewage disposal plant is about ninety thousand square meter. Both were selected as the areas for the tests to be conducted in determination test. The test to determine the level of noise, vibration, and total suspended particle was conducted thirty times around the blasting construction area by comparing measurement results and numerical analysis. However, as the test was not conducted in the laboratory but in the actual blasting construction area, it was not possible to do the test with the same exact conditions each true. Therefore, the test was not ideal as conditions could change from test to test. For the most part, the level of noise was below the standard level of 70dB. Every vibration test was under the standard limitation. For example, a house, 200m away was tested for noise and vibration and the level was found to be under the 0.2 cm/sec which is the standard for specialty designed cultural sites., i.e very low level. Also a buried oil pipeline that was 30m away also marked under 2.0cm/sec which is the norm for an industrial area. However, if there were an oil pipeline under the house, the amount of charging gunpowder per hole should be decreased compared to the amount used in the test. The test result for suspended particles under the standard limitation which is 24hour average 300$\mu\textrm{g}$/㎥ at a distance from blasting wavelength, but at detonator, total suspended particle from the blast origin exceeded the standard limitation. If explosion occurs when it detonates in the hole, most of the energy would be absorbed in the crushing of rocks, but some remaining energy would make noises and vibration inevitable. So the important thing is how to minimize the environmental pollution from the blasting. There should be regulations in order that the standard limitation is not exceeded, and to decrease the environmental pollution from the blasting.