• 제목/요약/키워드: Environmental Turbulence

검색결과 272건 처리시간 0.027초

The Suitability of European Designed Wind Turbines for the East Asian Market

  • Brown, G.R.D.;Barthelmie, R.J.;Kim, Hyun-Goo
    • 한국환경과학회지
    • /
    • 제18권8호
    • /
    • pp.825-831
    • /
    • 2009
  • A first step review is completed on the suitability of European designed wind turbines in an East Asia climate. Six parameters are chosen for detailed analysis of proper meteorological measures from flat, hilly, forested, coastal and offshore sites in West Europe and East Asia: mean wind speed, 10 minute mean wind speed distribution, turbulence intensity, wind shear, 3 second extreme wind speed and 10 minute direction change. All six parameters are assessed with a view for contrast with the wind turbine design standard IEC61400. The diurnal and seasonal variation, average and extreme values of each parameter are calculated where appropriate. Industry standard software and analysis techniques have been employed to assess the applicability of existing wind turbine design standards and design guidelines for the East Asian market.

e 비즈니스 전략 : 선행요인과 결과 (E-Business Strategies : The Antecedents and Consequences)

  • 구철모;김용진;남기찬
    • 한국경영과학회지
    • /
    • 제31권4호
    • /
    • pp.49-68
    • /
    • 2006
  • E-business strategy has interests in Issues of strategic positioning and its impact on firm performance. These studies address the environmental factors as antecedents to strategic decision makings and its consequences such like firm performance. However most studies has not considered the role of business models In explaining e-business firm performance. We adopt Porter's generic strategies to the e-business context. We Identify business models and e-business environmental factors as antecedents and then examine these factors Influence on firm performance. We find that uncertainty of environment has a negatively related to the strategic choices of e-Business firms; in contrast, market turbulence positively affects the level of adoption of all the strategies. Among the strategies, marketing differentiation only makes an Impact on firm performance.

측면 유출구를 갖는 3차원 실내 공간내의 열환경에 관한 연구 (A Study on Thermal Environment of 3-Dimensional Room with Side Wall Exhaust)

  • 정용현;김종렬;최광환;금종수;정효민
    • 한국환경과학회지
    • /
    • 제8권4호
    • /
    • pp.423-429
    • /
    • 1999
  • This study was performed to investigate the fluid flow characteristics, the temperature distribution, humidity and PMV(Predicted Mean Vote of thermal sensation) distributions of the 3-dimensional room with side wall exhaust. The finite volume method and turbulence k-$\varepsilon$ models with the SIMPLE computational algorithm are used. As the results of the three dimensional simulations, the region of exceeding Y=1.5m was high temperature and humidity. The inlet velocity and temperature were influenced to the floor strongly, and the room PMV was about -1.0 except the inlets.

  • PDF

부산의 지형적 특성을 고려한 $O_3$의 건성 침적속도 시뮬레이션 (A Simulation of the $O_3$Dry Deposition Velocity Considering Topographical Characteristics in Pusan)

  • 원경미;이화운
    • 한국대기환경학회지
    • /
    • 제14권5호
    • /
    • pp.421-432
    • /
    • 1998
  • Deposition processes limit the life time of pollutants in the atmosphere and control the distance travelled before deposition. Thus the understanding about atmospheric deposition processes is essential for a proper assessment of the environmental impacts due to the anthropogenic pollutants. The dry deposition velocities are related to surface types, atmospheric stabilities, friction velocities, air pollutants and so on. In this study we simulated the dry deposition velocities of O3 in Pusan region. The calculated deposition velocities compared to the observed O3 data obtained during the summer of 1988 over a deciduous forest in Canada. The comparison showed that the model somewhat overpredicted deposition velocities for the average diurnal variations with maxima in daytime and minima in nighttime mostly due to the turbulence intensity.

  • PDF

CFD와 PIV test를 통한 원형 2차침전지 유입 및 유출배플 형상 최적화 (Optimization of influent and effluent baffle configuration of circular secondary clarifier using CFD and PIV test)

  • 최영균;배강형
    • 상하수도학회지
    • /
    • 제28권1호
    • /
    • pp.73-81
    • /
    • 2014
  • One-dimensional flux theory (1DFT) is conventionally used for design of secondary clarifier of wastewater treatment plant. However, the 1DFT cannot describe turbulence, density current, shape parameters of the clarifier. In this study, we optimized the configurations of influent guide baffle and effluent baffle through the simulation using computational fluid dynamics (CFD) and its verification by particle image velocity (PIV) test. The energy dissipating inlet (EDI) without influent guide baffle ($0^{\circ}$) showed the best efficiency for minimizing downward velocity under the center well of the clarifier. The lowest velocity distribution around the effluent weir region could be obtained with the McKinney baffle (EB-2). The performances of the influent and effluent baffles were clearly verified by PIV test results.

환경변수가 자켓 하부구조물 해상 풍력시스템 거동에 미치는 영향 (Effects of environmental parameters for offshore wind turbine system with jacket support structure)

  • 이종선;박현철;;김용환;나상권;이종현
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.38.1-38.1
    • /
    • 2011
  • This study investigates the effects of Pierson-Moskowitz, Jonswap spectrum that are typical irregular wave spectrums for wind turbine system with jacket support structure. Also various offshore environmental parameters based on korean local condition were used in our study. The loads acting on the system was considered by referring to the Design Load Case from IEC guide line. And improved von Karman model was used as a turbulence model. As a result, various significant wave height and peak spectral period cause noticeable difference of extreme and fatigue loads prediction.

  • PDF

열원이 존재하는 작업장내 기류 및 온도장 예측 (Prediction of Airflow and Temperature Field in a Room With Convective Heat Source)

  • 정유진;하현철;김태형;유근종
    • 한국산업보건학회지
    • /
    • 제11권1호
    • /
    • pp.78-84
    • /
    • 2001
  • A CFD simulation of airflow and temperature field in a heated room has been described in this paper. The thermal wall jet created by a radiator greatly influences the airflow pattern, temperature distribution. The area close La a heat source has a higher risk of air-borne contamination and imposes a harmful effect on occupants in that area. The predicted flow field, temperature results show good agreement with the measured data. As the results were compared with experimental data, the applicability of CFD was satisfactorily verified. Also, the CFD simulation can capture the natural convective flow features. If a CFD simulation is applied ventilation design with a heat source, An effective design will be attained. Further study is required to improve the accuracy of CFD simulation.

  • PDF

타워 관측 자료를 이용한 연안 대기 경계층 내 바람 자원의 연직 변동 특성 (Characteristics of Vertical Variation of Wind Resources in Planetary Boundary Layer in Coastal Area using Tall Tower Observation)

  • 유정우;이화운;이순환;김동혁
    • 한국대기환경학회지
    • /
    • 제28권6호
    • /
    • pp.632-643
    • /
    • 2012
  • Analysis of wind resources in Planetary Boundary Layer (PBL) using long term observation of tall tower located near coast line of the Korean Peninsula were carried out. The data observed at Pohang, Gunsan and Jinhae are wind, temperature and relative humidity with 10 minute interval for one year from 1 October 2010. Vertical turbulence intensity and its deviation at Pohang site is smaller than those of other sites, and momentum flux estimated at 6 vertical layers tend to show small difference in Pohang site in comparison with other sites. The change of friction velocity with atmospheric stability in Pohang is also not so great. These analysis indicate the mechanical forcing due to geographical element of upwind side is more predominant than thermal forcing. On the other hand, wind resources at Gunsan and Jinhae are mainly controlled by thermal forcing.

Three-Dimensional Numerical Simulation of Intrusive Density Currents

  • An, Sangdo
    • 한국환경과학회지
    • /
    • 제23권7호
    • /
    • pp.1223-1232
    • /
    • 2014
  • Density currents have been easily observed in environmental flows, for instance turbidity currents and pollutant plumes in the oceans and rivers. In this study, we explored the propagation dynamics of density currents using the FLOW-3D computational fluid dynamics code. The renormalization group (RNG) $k-{\varepsilon}$ scheme, a turbulence numerical technique, is employed in a Reynold-averaged Navier-Stokes framework (RANS). The numerical simulations focused on two different types of intrusive density flows: (1) propagating into a two-layer ambient fluid; (2) propagating into a linearly stratified fluid. In the study of intrusive density flows into a two-layer ambient fluid, intrusive speeds were compared with laboratory experiments and analytical solutions. The numerical model shows good quantitative agreement for predicting propagation speed of the density currents. We also numerically reproduced the effect of the ratio of current depth to the overall depth of fluid. The numerical model provided excellent agreement with the analytical values. It was also clearly demonstrated that RNG $k-{\varepsilon}$ scheme within RANS framework is able to accurately simulate the dynamics of density currents. Simulations intruding into a continuously stratified fluid with the various buoyancy frequencies are carried out. These simulations demonstrate that three different propagation patterns can be developed according to the value of $h_n/H$ : (1) underflows developed with $h_n/H=0$ ; (2) overflows developed when $h_n/H=1$ ; (3) intrusive interflow occurred with the condition of 0 < $h_n/H$ < 1.

도심지 빌딩주변 자동차 배가스 분산에 관한 연구 (Numerical Simulation of Air Contaminant Dispersion around Urban City)

  • 유경석;유일광
    • 환경위생공학
    • /
    • 제21권2호
    • /
    • pp.11-19
    • /
    • 2006
  • Ran numerical analysis about simplicity warm current model (simple turbulence model) to examine closely distributed laying stress on NOx of contaminant that happen in downtown that building is massed and result is as following. Downtown building is massed and transfer of vehicles can know that frequent area receives greatly effect of building. Pollution displays class kind phenomenon striking in the building, class kind done pollution that show high density being mixed with pollution that happen in vehicles being flowed in again side know can. Divide velocity vector of pollution and density change to ancient city and did numerical analysis. Because NOx is flowed in diversion of water neighborhood by continuous this kind in Godo 20m point, density showed density of $0.0907mg/m^3s$, and can know that Banryuhyeon that Pollution strikes in the building at ancient city 30m point is decreased and approaches with freedom flowing without cooperation (cavity) phenomenon remarkably. Because pollution strikes in the building at distance shaft 383m point, class kind do phenomenon that know appeared notedly Nopeungeonmulgwanat between building pollution density $0.067mg/m^3$ head of a families high appear.