• 제목/요약/키워드: Environmental Testing

검색결과 1,661건 처리시간 0.034초

생태독성 숙련도 시료의 적절성 평가 (Validation of Suitability on Proficiency Testing Samples for Acute Toxicity Test with Daphnia magna)

  • 신기식;박우상;이정서;유순주;박태진;김종민
    • 한국물환경학회지
    • /
    • 제31권1호
    • /
    • pp.49-54
    • /
    • 2015
  • Acute toxicity test with Daphnia magna has a variety of factors such as incubation condition of test species, food quality and proficiency of laboratory workers. Therefore, proper proficiency testing samples were required for evaluating the competence of laboratory workers. This study aims to propose some appropriate proficiency testing samples for laboratory workers of acute toxicity test with Daphnia magna. Proposed four kinds of standard samples (Sample A, B, C, and D) for proficiency testing were selected from reference materials which were recommended from Canada and USA WET(Whole Effluent Toxicity) authorities. Proposed standard samples were tested by trial application of proficiency testing, homogeneity and stability checks using repeatability test. Sample A, C and D were estimated ad the suitable candidates for proficiency test standard samples except for Sample B. In addition, Sample A was proved to be the most suitable sample.

국내 생태독성 분석기관에 대한 숙련도시험 결과 평가 (Interlaboratory Study for Proficiency Testing on the Water Toxicity Determinations by Acute Toxicity Test with Daphnia magna)

  • 김종민;신기식;유순주;김명옥;최성헌
    • 한국물환경학회지
    • /
    • 제30권6호
    • /
    • pp.632-637
    • /
    • 2014
  • Proficiency testing by interlaboratory comparisons is used to determine the performance of individual laboratories. In order to verify the quality of acute toxicity testing with Daphnia magna, National Institute of Environmental Research in South Korea is regularly organizing interlaboratory comparisons to estimate the analytical accuracy of different laboratories. Total 58 laboratories located in South Korea took part in interlaboratory proficiency testing scheme with three proficiency testing samples. TU(Toxic Unit) values of each laboratory were determined and robust z-score was calculated in order to evaluate the proficiency levels. Based on the robust z-score classification, 74% of the participant laboratories showed a satisfactory performance (43 laboratories). The main reason of 'unsatisfactory' performance seemed to be considered that the unsuitable management of test organism incubation system and the lack of experience on the identification of the test organism condition by effect of toxicity.

중금속분석용 하천수 매질표준물질을 이용한 숙련도 결과 평가 (Evaluation of the proficiency testing results using river water-based reference materials for heavy metal analysis)

  • 송기봉;김영희;신선경;이수영;김현정;강학구;김일규;안희주
    • 분석과학
    • /
    • 제23권3호
    • /
    • pp.284-294
    • /
    • 2010
  • 하천수 시료를 이용한 중금속분석용 수질표준물질, NIER-I08RW 및 NIER-I09를 제조하여 납, 카드뮴, 크롬, 구리 등 중금속 4 종에 대한 인증분석 및 불확도 등을 평가하였다. 균질성 평가 결과, 병간균질도가 숙련도시험의 목표표준편차의 0.3 배 이하로서 숙련도시험용 시료로서 사용하기에 충분히 균질한 시료인 것으로 확인되었다. 제조된 표준물질을 이용하여 국내 환경측정분석기관을 대상으로 숙련도시험을 실시하고, 설정값의 설정방법에 따른 로버스트 Z 값의 변동을 비교하였다. 다른 항목에 비해 농도가 낮은 NIER-I08RW의 카드뮴 항목을 제외하고는, 특성값과 참가기관의 합의값의 차이인 상대편차, $B_{relative}$는 모두 ${\pm}$1 이하로서 크지 않았으며, 설정값을 달리 설정함으로 Z 값이 달라진 경우는 46 개로서 전체의 2.9%에 불과하였다.

고전압 개폐장치의 보조회로 및 제어회로에 대한 환경시험 검토(2) (A Study on Environmental Tests for Auxiliary and contol circuits of HV Switchgears and controlgears(2))

  • 이정기;박영창;정주영;김익수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1443_1444
    • /
    • 2009
  • A study on the environmental tests for auxiliary and control circuits of high voltage switchgears, especially testing condition and requirements, according to the relevant international standards has been briefly reviewed in this paper. As the highest supply voltage of electric power systems have been progressed, testing techniques and testing standards such IEC codes improved and revised keeping step with it. Especially IEC 62271 series, which are applicable to the HV-class switchgears and controlgears have been revised in 2008 newly. In this paper, the special consideration and background information of environmental testing condition with mechanical operating performance, e.g. operation in a higher and lower ambient temperature, for the auxiliary and control circuits of switchgears and controlgears and considerable investigation to the related international standards have been provided. Examples of testing performed were showed and analysis of their test results have been described.

  • PDF

Analysis of the influence of panel characteristics on odor measurement based on the air dilution olfactory method in Korea

  • Kim, Sun-Tae;Lee, Seokjun;Yim, Bongbeen
    • Environmental Engineering Research
    • /
    • 제24권1호
    • /
    • pp.91-98
    • /
    • 2019
  • This study was to objectify differences in the results of odor testing according to the characteristics of panel members that participate in air dilution olfactory method (ADOM) testing. When differences in the results of olfactory testing were reviewed in relation to characteristics of the panelists, the result of entire panels for the site boundary Proficiency Testing Materials (PTMs) showed no difference according to panelist sex, age, smoking status, and past participation in ADOM tests. As for the outlet PTMs, distinct differences appeared in relation to the smoking status and age of panelists. The frequency distribution for all the panelists (Dev($D/T_{total}$)) showed a form similar to a normal distribution, so it is thought to be more appropriate for the review of effect of panelist characteristics on the result of air dilution olfactory tests. In addition, the ADOM testing method implemented as the standard method for odor compounds in Korea (Dev($D/T_3$)) will have to be implemented along with a concurrent assessment, for the purpose of identifying the effect of panelist characteristics on administrative dispositions against malodors.

환경시험방법에 의한 내화도료의 내화성능에 관한 실험적 연구 (An Experimental Study on the Fire Resistance Performace of Intumescent Coating System by Environmental Testing Procedure)

  • 박수영;성시창;최동호;김대회;이세현;이종찬
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.69-72
    • /
    • 2008
  • This study is designed to understand changes in fire resistance performance of intumescent coating system through follow-up tests on temperature of unexposed surface for the domestic intumescent coating system by environmental testing procedure.

  • PDF

환경 및 신뢰성 시험분야를 위한 숙련도시험 시료개발 연구 (A Study on Proficiency Test Sample Development for Environmental & Reliability Testing Field)

  • 박경환;이철규
    • 품질경영학회지
    • /
    • 제45권3호
    • /
    • pp.447-462
    • /
    • 2017
  • Purpose: This study aims to develop distributable samples that can be used for proficiency testing to verify the ability of the testing laboratory to perform high temperature and low temperature tests. Method: In this study, the temperature-resistance characteristics of the NTC thermistor were used to develop samples. The homogeneity and stability of samples were examined according to the proficiency testing requirements. Results: Thirty samples with homogeneity and stability were developed and used for the proficiency testing. Thus, it was possible to distinguish between the test laboratories that showed satisfactory results and those that did not. Conclusion: It was the first time to develop samples that can be used for proficiency testing in high temperature and low temperature tests. and it was proved that the proficiency test program can be operated using the characteristics of NTC thermistor.

중금속분석용 폐수표준물질 제조 및 실험실간 비교평가 (Preparation of wastewater-based reference materials for heavy metal analysis and interlaboratory study)

  • 김영희;송기봉;신선경;이정섭;정기택;홍은진;박진주;유석민
    • 분석과학
    • /
    • 제23권3호
    • /
    • pp.295-303
    • /
    • 2010
  • 폐수 시료를 이용한 중금속분석용 수질표준물질을 제조하여, 납, 카드뮴, 크롬, 구리, 아연, 망간, 철 등 중금속 7 종에 대해 인증분석 및 불확도 등을 평가하고, 24 개 환경측정분석기관을 대상으로 실험실간 비교실험을 실시하였다. 폐수표준물질의 인증값 및 확장불확도는 KS A ISO 가이드 35(2005)에 의해 도출하였으며, 균질성에 기인한 표준불확도는 특성값의 0.43~2.67%로 나타났다. 환경측정분석기관간 비교실험에서 모든 항목의 비교실험 결과값이 정규분포를 따랐으며, 로버스트 평균값과 폐수표준물질의 인증값과 비교한 결과, 대부분의 항목에서 로버스트 평균값이 인증값보다 낮게 나타났다.

주관평가 방법에 의한 환경소음 음질평가 (The Sound Quality Analysis of Environmental noise by Jury Testing)

  • 조경숙;허덕재;조연
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.712-717
    • /
    • 2004
  • Recently, the concern for the environmental noise has increased due to the growing of the living standard. The environmental noise regulations based on the equivalent noise level are widely used. However, the noise level, which Is based mainly on the magnitude with A-weighting, the important characteristics of noises in frequency and time domains and the impulsive nature cannot be assessed properly. These can have substantial effects on how human respond to noise. Therefore, the noise evaluation methodology based on the sound quality rather than the equivalent noise level can be more suitable to represent human response to the environmental noise. This paper describes the study on environmental noise quality analysis for various noises. A cluster analysis was carried out and the noises were classified into several clusters using the values of sound quality metrics. The classification was confirmed by comparing time and frequency characteristics of the noises. And then the result of Jury testing was analysis.

  • PDF

Ultrasonic treatment of waste livestock blood for enhancement of solubilization

  • Jeon, Yong-Woo;Kim, Hyeon-Jeong;Shin, Myung-Seop;Pak, Seo-Hyun
    • Environmental Engineering Research
    • /
    • 제21권1호
    • /
    • pp.22-28
    • /
    • 2016
  • The aim of this study was to recycle the waste livestock blood as one of the waste biomass by turning proteins, the main constituent of blood, into effective biological resources like amino acid. Ultrasonic technology was applied to solubilize the proteins in the waste livestock blood. And of the multiple ultrasonic frequencies tested, 20 kHz was confirmed to yield the highest solubilization rate. The optimum pretreatment conditions were determined to be 30-min treatment at an ultrasonic irradiation density of 0.5 W/mL, which resulted in a solubilization rate of 96.01%. Also, a gel permeation chromatography (GPC) confirmed that a large amount of proteins were solubilized, and in an experiment where ultrasonic treatment was applied to kill bacteria, death rates of general bacteria and total coliforms were found to be reduced by 99.93% and 100%, respectively. Based on these results, ultrasonic technology was confirmed to be a crucial part of treating and recycling the proteins in waste livestock blood.