• Title/Summary/Keyword: Environmental Tester

Search Result 123, Processing Time 0.025 seconds

Design Validation through Analysis of Concrete Modular Road Behavior under Static Axial Loads (콘크리트 모듈러 도로 축하중 거동 분석을 통한 설계 타당성 검증)

  • Nam, Jeong-Hee;Kim, Woo Seok;Kim, Ki Hyun;Kim, Yeon Bok
    • International Journal of Highway Engineering
    • /
    • v.17 no.6
    • /
    • pp.37-45
    • /
    • 2015
  • PURPOSES : The purpose of this study is to validate the design criteria of the concrete modular road system, which is a new semi-bridge-type concept road, through a comparison of numerical analysis results and actual loading test results under static axial loads. METHODS : To design the semi-bridge-type modular road, both the bridge design code and the concrete structural design code were adopted. The standard truck load (KL-510) was applied as the major traffic vehicle for the design loading condition. The dimension of the modular slab was designed in consideration of self-weight, axial load, environmental load, and combined loads, with ultimate limit state coefficients. The ANSYS APDL (2010) program was used for case studies of center and edge loading, and the analysis results were compared with the actual mock-up test results. RESULTS : A full-scale mock-up test was successfully conducted. The maximum longitudinal steel strains were measured as about 35 and 83.5 micro-strain (within elastic range) at center and edge loading locations, respectively, under a 100 kN dual-wheel loading condition by accelerating pavement tester. CONCLUSIONS : Based on the results of the comparison between the numerical analysis and the full-scale test, the maximum converted stress range at the edge location is 32~51% of the required standard flexural strength under the two times over-weight loading condition. In the case of edge loading, the maximum converted stresses from the Westergaard equation, the ANSYS APDL analysis, and the mock-up test are 1.95, 1.7, and 2.3 times of that of the center loading case, respectively. The primary reason for this difference is related to the assumption of the boundary conditions of the vertical connection between the slab module and the crossbeam module. Even though more research is required to fully define the boundary conditions, the proposed design criteria for the concrete modular road finally seems to be reasonable.

Performance of HFC152a, HFC134a and HC290 Mixtures as Alternative Refrigerants for HFC134a (HFC152a, HFC134a, 프로판을 포함한 자동차용 대체/보충 냉매의 성능)

  • Kang, Nam-Koo;Bae, Guen-Hwan;Park, Ki-Jung;Jung, Dong-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.6
    • /
    • pp.383-391
    • /
    • 2010
  • In this study, HFC152a, HFC134a/HFC152a and HC290/HFC134a/HFC152a mixtures are studied for the supplementary and alternative refrigerants for HFC134a used in automobile air-conditioners. Due to the high global warming potential of HFC134a, it has to be phased out in the long run. Thermodynamic performance of these refrigerants are measured in a bench tester of 3.5 kW capacity with an open type compressor under both summer and winter conditions. Test results show that the coefficient of performance (COP) and capacity of pure HFC152a and HFC134a/HFC152a mixture are 9.1~12% and 7% higher than those of HFC134a. As for the HC290/HFC134a/HFC152a, the COP is up to 9.5% higher than that of HFC134a with 1~2% of HC290 while that is up to 6.1% lower than that of HFC134a with 5% HC290. The capacity of the ternary mixture, however, is 8.6% higher than that of HFC134a at all compositions tested. The compressor discharge temperatures of all refrigerants tested are $6{\sim}10^{\circ}C$ higher than that of HFC134a. For all refrigerants, the amount of charge is reduced up to 32% due to the decrease in liquid density. Overall, these refrigerants provide good performance with reasonable energy savings with less environmental problem and thus can be used as long term alternatives for automobile air-conditioners.

In Vitro Studies on the Genotoxic Effects of Wood Smoke Flavors

  • Chung, Young-Shin;Ahn, Jun-Ho; Eum, Ki-Hwan;Choi, Seon-A;Oh, Se-Wook;Kim, Yun-Ji;Park, Sue-Nie;Yum, Young-Na;Kim, Joo-Hwan;Lee, Michael
    • Toxicological Research
    • /
    • v.24 no.4
    • /
    • pp.321-328
    • /
    • 2008
  • Smoke flavors based on the thermal decomposition of wood have been applied to a variety of food products as an alternative for traditional smoking. Despite its increasing use, the available genotoxicity data on wood smoke flavors (WSF) are still controversial. Thus, potential genotoxic effects of WSF in four short-term in vitro genotoxicity assays were investigated, which included the Ames assay, chromosomal aberration assay, micronucleus test and the alkaline comet assay. WSF did not cause any mutation in the Ames assay using five tester strains at six concentrations of 0.16, 0.31, 0.63, 1.25, 2.5 and 5 ${\mu}l/plate$. To assess clastogenic effect, the in vitro chromosomal aberration assay was performed using Chinese hamster lung cells. No statistically significant increase in the number of metaphases with structural aberrations was observed at the concentrations of 1.25, 2.5, and 5 ${\mu}l/ml$. The in vitro comet assay and micronucleus test results obtained on L5178Y cells also revealed that WSF has no genotoxicity potential, although there was a marginal increase in micronuclei frequencies and DNA damage in the respective micronucleus and comet assays. Taken together, based on the results obtained from these four in vitro studies, it is concluded that WSF is not a mutagenic agent in bacterial cells and causes no chromosomal and DNA damage in mammalian cells in vitro.

Genotoxicity of cadmium chloride in Salmonella typhimurium and rat liver epithelial cells (카드뮴의 Salmonella typhimurium 변이균주 및 랫드 간장 상피세포에서의 유전독성)

  • Jeong, Sang-hee;Cho, Myung-haing;Cho, Joon-hyoung
    • Korean Journal of Veterinary Research
    • /
    • v.38 no.3
    • /
    • pp.606-613
    • /
    • 1998
  • Cadmium is one of the well-known environmental toxicants and induces cancer in rodents and human, but its carcinogenic mechanism has not been well demonstrated until now. Genotoxic effects of cadmium in Salmonella typhimurium TA98, TA100 and TA1535/pSK1002 or in WB-F344 rat liver epithelial cells were investigated to elucidate the tumor initiating effects of cadmium. TA98, TA100 and TA1535/pSK1002 tester strains were used to detect frameshift mutation, base-pair mutation and SOS repair response, respectively, in Salmonella mutation test. Reverse mutations from histidine to $histidin^+$ of Salmonella typhimurium TA98 and TA100 by $CdCl_2$ were not significantly different from control up to the maximum doses ($100{\mu}M$ and $200{\mu}M$ in TA98 and TA100, respectively) at which non-cytotoxicity was observed. DNA SOS repair responses(${\beta}$-galactosidase activity) generally did not show significant increases compared to control in both of the conditions with or without metabolic activation in Salmonella typhimurium TA1535/pSK1002 by $CdCl_2$. But the activities of ${\beta}$-galactosidase by $400{\mu}M$ of $CdCl_2$ in metabolic activation condition and by 130 and $400{\mu}M$ of $CdCl_2$ in non-metabolic activation condition were more decreased than those of control. DNA single strand breaks for 4hrs were observed only in WB-F344 rat liver epithelial cells treated with $200{\mu}M$ of $CdCl_2$. As a conclusion, $CdCl_2$ did not induce gene mutation in microbials but induce DNA single strand breaks in rat liver epithelial cells.

  • PDF

A Study on Improvement of Shear Test Apparatus in the Direct Shear Test Under Constant Pressure (정압(CD)조건 직접전단시험에 있어서 시험기의 개선에 관한 연구)

  • Kim Jae Young;Yang Tae Seon;Akihiko Ohshima
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.2
    • /
    • pp.137-144
    • /
    • 2005
  • A direct shear test is classified roughly by one side simple shear test of confining horizontal displacement type and torsional shear test of non-confining one. Direct shear test that has been widely used so far has some problems with test apparatus, testing and the analysis, and in particular that its strength value is everestimated in sandy soils. Also, progressive failure of shearing process happens from shear apparatus restriction and because the shear strain and shear stress are erratic in specimen, we can not define the shear strain value. In the meantime, a simple shear test having advantage of direct shear test is an ideal test method that can get stress-strain relation on shear because it can deliver constant shearing deformation to specimen. However, simple shear test cannot be used practically, because its structure makes tester manufacturing difficult. This paper described a on outline of test apparatus, improvement of test method, and constant pressure test results based on the obtained from improved direct shear apparatus and the standardization of JGS soil testing method.

Wear Characteristics of Rubber-Seal for Inflow of Dust Particles in Automobile Chassis System -PART II: The Influence of Dust Particle Inflow on Wear Characteristics of Rubber-Seal- (자동차 섀시 시스템에 유입되는 먼지입자에 의한 고무-씨일 부품의 마멸특성 -PART II: 먼지유입에 따른 고무-씨일의 마멸특성-)

  • Lee, Young-Ze;Chung, Soon-Oh;Won, Tae-Yeong;Kim, Gi-Hoon;Kim, Dae-Sung
    • Tribology and Lubricants
    • /
    • v.25 no.4
    • /
    • pp.261-264
    • /
    • 2009
  • Environmental factors affect parts of the automobile. When dust particles are embedded, specially, friction and wear of the rubber-seal in automobile chassis system are increased. Increase in friction and wear leads to weakness of component and reduction of mechanical life. In this study, the wear characteristics of rubber-seal for inflow of dust particles are investigated. Silica($SiO_2$) and alumina($Al_2O_3$) particles are used as a dust particle because these particles are main elements of dust particles. The sliding wear tester are used for investigate the wear characteristics of rubber-seal. If the single dust particle($SiO_2$) is embedded in the rubber-seal component, the influence of dust particle size is more than that of inflow rate on the wear characteristics of rubber-seal. If the mixed dust particles are embedded in the rubber-seal component, the wear rate is increased as the rate of alumina that has a bigger hardness is increased. If the mixed dust particles that have different hardness are embedded in the rubber-seal component, the influence of particle size is more than that of particle hardness.

Friction and Wear Characteristics of the Micro-dimple Surfaces in Rotary Compressor with Carbon Dioxide as Refrigerants ($CO_2$ 환경하에서 접촉 표면에 적용한 마이크로 딤플 패턴이 마찰 및 마멸에 미치는 영향 연구)

  • Lee, Young-Ze;Jeon, Hong-Gyu;Han, Kyu-Cheol;Choi, Jin-Ho;Kim, Gyu-Man;Cho, Sung-Ouk
    • Tribology and Lubricants
    • /
    • v.24 no.6
    • /
    • pp.374-377
    • /
    • 2008
  • Due to the environmental concerns, especially the greenhouse effect and GWP (Global Warming Potential), the carbon dioxide was investigated as an alternative natural refrigerant to replace HFCs (HydroFluoroCarbons) in refrigerator or air conditioning systems. Because new compressor with carbon dioxide is going to be operated under the high pressure, the tribology of sliding surfaces in the compressor becomes very important. To improve of wear resistance in compressor parts, especially rotary type, the friction and wear characteristics of improved sliding surfaces between vane and flange were evaluated in this paper. The method of reformed sliding surface, such as micro-dimple processes, was applied on surfaces in order to improve the tribological characteristics, and their performances were evaluated experimentally. The vane-on-flange type lubricated sliding tests were performed with a high pressure wear tester using carbon dioxide. Test results showed that the reformed surfaces were very effective to reduce the friction and the wear amounts of vane surfaces. The method of improved surfaces showed good tribological properties at vane and flange.

Dynamics of Hexavalent Chromium in Four Types of Aquaculture Ponds and Its Effects on the Morphology and Behavior of Cultured Clarias gariepinus (Burchell 1822)

  • Mustapha, Moshood Keke
    • Toxicological Research
    • /
    • v.33 no.2
    • /
    • pp.119-124
    • /
    • 2017
  • Hexavalent chromium is a bio accumulative toxic metal in water and fish. It enters aquaculture ponds mainly through anthropogenic sources. Hexavalent chromium concentrations and its effects on the morphology and behavior of Clarias gariepinus were investigated from four aquaculture ponds for 12 weeks. Chromium was measured using diphenyl carbohdrazide method; alkalinity and hardness were measured using colometric method and analyzed with Bench Photometer. Temperature and pH were measured using pH/EC/TDS/Temp combined tester. Temporal and spatial replications of samples were done with triplicates morphological and behavioural effects of the metal on fish were observed visually. Chromium ranged from no detection to 0.05 mg/L, alkalinity 105 to 245 mg/L, hardness 80 to 165 mg/L, pH 6.35 to 8.03 and temperature 29.1 to $35.9^{\circ}C$. Trend in the chromium concentrations in the ponds is natural > earthen > concrete > collapsible. There was a significant difference (P < 0.05) in chromium, alkalinity, water hardness, pH and temperature among the four ponds. Significant positive correlation also existed between alkalinity, water hardness, pH, with chromium. Morphological and behavioural changes observed in the fish include irregular swimming, frequent coming to the surface, dark body colouration, mucous secretion on the body, erosion of gill epithelium, fin disintegration, abdominal distension and lethargy. High chromium concentration in natural pond was due to anthropogenic run-off of materials in to the pond. Acidic pH, low alkalinity, low water hardness also contributed to the high chromium concentration. Morphological and behavioural changes observed were attributed to the high concentrations, toxicity and bio accumulative effect of the metal. Toxicity of chromium to fish in aquaculture could threaten food security. Watershed best management practices and remediation could be adopted to reduce the effects of toxicity of chromium on pond water quality, fish flesh quality and fish welfare.

Flocculation of Red Tide Organisms in Sea Water by Using an Ignited Oyster Shell Powder and Loess Combination (소성굴패각분말과 황토의 동시 사용에 의한 적조생물의 응집)

  • KIM Sung-Jae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.36 no.6
    • /
    • pp.716-722
    • /
    • 2003
  • This study determined the optimum dosage for coagulation reactions of red tide organisms (RTO) using a combination of ignited oyster shell powder (10sp) and loess and examined the electrokinetic and rheological characteristics of their flocs. Two kinds of RTO, Cylindrotheca closterium and Skeletonema costatum, were sampled in Masan Bay and cultured in the laboratory. Coagulation experiments were conducted using various concentrations of IOSP, loess, IOSP+1oess, RTO, and a jar tester RTO cell numbers were counted for both the supernatant and RTO culture solution. The removal rates increased rapidly with increasing IOSP concentrations up to 50 mg/L and loess concentrations up to 800 mg/L. A removal rate of $100\%$ was reached at 400 mg/L of IOSP and 6,400 mg/L of loess. The highest increment $(16.7\%)$ of the rates of coagulation reaction occurred using both IOSP and loess (50+200 mg/L) in comparison with IOSP alone. The rate of coagulation reaction using both IOSP and loess (50+200 mg/L), $90.6\%,$ was similar to employing either IOSP of 150 mg/L or loess of 3,200 mg/L. All of the coagulation liquids for RTO, IOSP (200 mg/L), loess (200 ma/L), and IOSP+1oess (200+200 mg/L) revealed non-Newtonian fluid properties and therefore their shear rate vs. shear stress curves were non-linear. The coagulation liquids revealed elastic body properties at a lower shear rate increasing in the following order: RTO, IOSP (200 mg/L), loess (200 mg/L), and IOSP+1oess (200+200 mg/L. IOSP+1oess (200+200 mg/L) especially demonstrated plastic flow properties at a lower shear rate.

Performance of R502 Alternative Refrigerants for Low Temperature Applications (저온용 R502 대체냉매의 성능 평가)

  • Ha Jong-Chul;Hwang Ji-Hwan;Baek In-Chul;Jung Dongsoo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.10
    • /
    • pp.883-890
    • /
    • 2005
  • In this study, 2 pure hydrocarbon refrigerants of R1270 (Propylene) and R290 (Propane) and 3 binary mixtures composed of R1270, R29O and R152a were tested in a refrigerating bench tester with a scroll compressor in an attempt to substitute R502 used in most of the low temperature applications. The test bench provided 3\sim3.5$ kW capacity and water and water/glycol mixture were employed as the secondary heat transfer fluids. All tests were conducted under the same external conditions resulting in the average saturation temperatures of -28 and $45^{\circ}C$ in the evaporator and condenser, respectively. Test results showed that all refrigerants tested had $9.6\sim18.7\%$ higher capacity and $17.1\sim27.3\%$ higher COP than R502. The compressor discharge temperature of R1270 was similar to that of R502 while those of all other refrigerants were $23.7\sim27.9\%$ lower than that of R502. For all alternative refrigerants, the amount of charge was reduced up to $60\%$ as compared to R502. Overall, these alternative refrigerants offer better system performance and reliability than R502 and can be used as long term substitutes for R502 due to their excellent environmental properties.