• 제목/요약/키워드: Environmental Tester

검색결과 123건 처리시간 0.024초

대형 환경시험조 내의 복합무기체계 재료에 대한 열유동 수치해석 (Numerical Analysis of Thermal Flow for Materials of Combined Weapon System in Large Environmental Tester)

  • 김성대;유성열;백상화;이정용;박소진;김철주;고한서
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3144-3149
    • /
    • 2007
  • A numerical analysis for temperature distribution of four different materials such as iron, silicon, aluminum and PVC has been performed in this study to predict thermal behaviors of combined weapon systems in a large environmental tester. Thus, experimental conditions have been proposed using a calculating software (SolidWorks 2007 COSMOS FloWorks) to prepare for field tests and analyze heat flow inside the environmental tester and temperature distributions of materials. The boundary conditions of the analysis are composed of inlet and outlet conditions of the environmental tester with different pressures and the limit of low temperature of -30$^{\circ}C$. The soaking time of the system in the environmental tester has been calculated by this commercial program in this study to carry out the experiment.

  • PDF

복합무기체계 실험을 위한 열유동 수치해석 기법 개발 (Development of Numerical Analysis Technique of Thermal Flows for Experiment of Combined Weapon Systems)

  • 김성대;유성열;백상화;이정용;박소진;김철주;고한서
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.397-400
    • /
    • 2008
  • A numerical analysis has been performed in this study to predict thermal behaviors of combined weapon systems in a large environmental tester. Also, temperature distributions of the materials of the system have been measured for the experimental conditions. The calculated thermal flow characteristics and the measured temperature distributions of the materials for the weapon systems have been analyzed to prepare for field tests in the environmental tester. The boundary conditions of the analysis are composed of inlet and outlet conditions of the environmental tester with various pressures and the limit of low temperature of -25$^{\circ}$C. The soaking time of the system in the environmental tester has been obtained by developed programs in this study to carry out the experiment in the predicted conditions.

  • PDF

Cell Tester에 의한 막특성 연구 (Effects of membrane characteristics by Cell Tester)

  • 전양근;성일화
    • 환경위생공학
    • /
    • 제12권1호
    • /
    • pp.77-83
    • /
    • 1997
  • An experimental research was conducted in order to study the treatment of waste reuse system using the membrane. Cell tester which supplied by Amicon was used to compare the fluxes of various membranes. Specially investigated items in the experiment were carried out by using 5 species of microfiltration membranes as to various MLSS concentrations. From the results, it is recognized from the cell test that 0.2 $\mu $m pore-sized membrane have the most effective performance at 2000mg/L of MLSS, and physical properties of membranes such as strength, deflection, elongation, structure of pore are more important than chemical properties in microfiltration membrane.

  • PDF

열전소자를 이용한 온도 환경시험기의 퍼지제어기 개발 (Development of Fuzzy Controller for Temperature Environment Tester Using Thermoeletric Module)

  • 황기현
    • 한국정보통신학회논문지
    • /
    • 제19권5호
    • /
    • pp.1228-1234
    • /
    • 2015
  • 본 논문에서는 열전소자를 이용한 온도 환경 시험기에 적용할 수 있는 퍼지제어기를 개발하였다. 온도환경 시험기에 퍼지제어기를 구현하기 위해 마이컴기반의 온도제어시스템을 제작하였다. 안정적인 온도 유지 및 온도 변화 속도를 향상시키기 위하여 퍼지제어기를 내장한 온도환경 시험기를 개발하였다. 제안한 방법의 유용성을 입증하기 위하여, 일반적으로 널리 사용되고 있는 비례-적분-미분 제어기와 비교하였다. 실험결과 제안한 퍼지제어기가 기존의 비례-적분-미분 제어기보다 상승시간, 오버슈트 면에서 좋은 제어성능을 보임을 알 수 있었다.

표준압밀시험기를 사용하는 수평배수 압밀셀의 개발 (Developement of Consolidation Cell of Horizontal Drainage using Standard Consolidation Tester)

  • 주재우;정규향;조삼덕;이천주;박종범
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.678-683
    • /
    • 2004
  • The most popular consolidation tester is a standard consolidatiion tester, which performs consolidation using the step load weight. However this apparatus is used to obtain only the vertical consolidation coefficient. Therefore the purpose of this study is to develope the horizontal consolidation cell for a horizaontal consolidation coefficient. Various size of tests have been peroformed to investigate the effect of scale effect. From the test results, it has turned out that this horizontal consolidation cell has a good function for a horizontal consolidation coefficient.

  • PDF

Human body model electrostatic discharge tester using metal oxide semiconductor-controlled thyristors

  • Dong Yun Jung;Kun Sik Park;Sang In Kim;Sungkyu Kwon;Doo Hyung Cho;Hyun Gyu Jang;Jongil Won;Jong-Won Lim
    • ETRI Journal
    • /
    • 제45권3호
    • /
    • pp.543-550
    • /
    • 2023
  • Electrostatic discharge (ESD) testing for human body model tests is an essential part of the reliability evaluation of electronic/electrical devices and components. However, global environmental concerns have called for the need to replace the mercury-wetted relay switches, which have been used in ESD testers. Therefore, herein, we propose an ESD tester using metal oxide semiconductor-controlled thyristor (MCT) devices with a significantly higher rising rate of anode current (di/dt) characteristics. These MCTs, which have a breakdown voltage beyond 3000 V, were developed through an in-house foundry. As a replacement for the existing mercury relays, the proposed ESD tester with the developed MCT satisfies all the requirements stipulated in the JS-001 standard for conditions at or below 2000 V. Moreover, unlike traditional relays, the proposed ESD tester does not generate resonance; therefore, no additional circuitry is required for resonant removal. To the best of our knowledge, the proposed ESD tester is the first study to meet the JS-001 specification by applying a new switch instead of an existing mercury-wetted relay.

가속노화시험장치를 적용한 틸팅열차용 유리섬유직물/페놀릭 복합재의 노화특성 평가 (Aging Characteristics of Glass Fabric/Phenolic Composites for Tilting Train Using Accelerated Aging Tester)

  • 윤성호;남정표;황영은;이상진;신광복
    • 한국철도학회논문집
    • /
    • 제8권2호
    • /
    • pp.188-194
    • /
    • 2005
  • Aging characteristics of glass fabric/phenolic composites for tilting train subjected to combined environmental aging factors were investigated. A 2.5KW accelerated aging tester with a xenon-arc lamp was used to provide environmental aging factors such as temperature, moisture, and ultraviolet. A series of aging tests were conducted up to 3000 hours and several types of specimens were prepared along the warp direction and the fill direction. Mechanical degradations for tensile, flexural, and shear properties were evaluated as a function of exposure times through a material testing system. Thermal analysis properties such as storage shear modulus, loss shear modulus, and tan 3 were measured through a dynamic mechanical analyzer. Finally exposed surfaces of the composites were examined using a scanning electron microscope. According to the experimental results, mechanical properties and thermal analysis properties of glass fabric/phenolic composites were found to be slightly degraded as a function of exposure times due to combined environmental effects.

열전소자 원리를 이용한 부품 Tester용 온도공급 장치 연구 (메모리 Device Tester용 온도제어장치 도입을 위한 연구) (A Study for Adopting the Temperature Control Unit on Memory Device Tester Based on Principle of Thermoelectric Semiconductor)

  • 김선주;홍철호;신동욱;서승범;이무재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.414-416
    • /
    • 2003
  • 메모리 제품의 사용 환경은 점차적으로 High Speed/High Density화됨에 따라 현 Comp. Test 환경으로 Field 환경을 모두 수용하기가 어려워지고 있다. 따라서, Component Level에서 다양한 실장 System을 이용한 Screen 방법이 요구 되고 있다. 다양한 환경에서 Test를 실시하기 위해서 필수 불가결한 조건은 온도(Temperature)를 자동으로 제어(Control)할 수 있는 기능이 필요하게 되었다. 이에, 현재 사용하고 있는 방법은 Chamber나 히터를 이용하고 있으나 온도 제어가 보다 용이하고 정밀한 기능이 요구됨에 따라 열전반도체(Thermoelectric semiconductor)원리를 이용한 온도 제어 장치 도입을 위한 연구가 진행되었다. 본 논문에서는 그 개발 현황 및 평가 결과를 근거로 신규 Component실장 Tester에 효율적으로 도입 적용 가능함을 제시 하고자 한다. 또한, 향후 기타 Tester 및 산업용 설비 등에 까지 확대적용 가능함으로써 전자부품(메모리)의 품질 향상 및 설비투자 Cost절감 효과가 기대 된다.

  • PDF

A Study of Aging Effect for Train Carbody Using Accelerated Aging Tester

  • Nam, Jeong-Pyo;LI, Qingfen;LI, Hong
    • International Journal of Railway
    • /
    • 제1권3호
    • /
    • pp.113-116
    • /
    • 2008
  • The long-tenn exposure of polymeric composite materials to extreme-use environments, such as pressure, temperature, moisture, and load cycles, results in changes in the original properties of the material. In this study, the effect of combined environmental factors such as ultraviolet ray, high temperature and high moisture on mechanical and thermal analysis properties of glass fabric and phenolic composites are evaluated through a 2.5 KW accelerated environmental aging tester. The environmental factors such as temperature, moisture and ultraviolet ray applied of specimens. A xenon-arc lamp is utilized for ultraviolet light and exposure time of up to 3000 hours are applied. Several types of specimens - tensile, bending, and shear specimens that are warp direction and fill direction are used to investigate the effects of environmental factors on mechanical properties of the composites. Mechanical degradations for tensile, bending and shear properties are evaluated through a Universal Testing Machine (UTM). Also, storage shear modulus, loss shear modulus and tan a are measured as a function of exposure time through a Dynamic Mechanical Analyzer (DMA). From the experimental results, changes in material properties of glass fabric and phenolic composites are shown to be slightly degraded due to combined environmental effects.

  • PDF

호스지표살포기의 악취감소효과 분석 (Effect of the Hose Slurry Spreader on Oder Reduction)

  • 오인환;김기덕
    • 한국축산시설환경학회지
    • /
    • 제7권2호
    • /
    • pp.119-126
    • /
    • 2001
  • For the odor test, it was chosen the conventional spreader, the hose spreader, and its combination with disk harrow and spring harrow as a slurry spreader. By the odor tester (Kalmor-$\sum$) with dairy slurry, the conventional spreader has the average $\sum$ value of 270, which means that one fells substantial odor and torment. In the cases of hose spreader and its combination with disk harrow, $\sum$ value was 217 and 182 respectively, which means a normal person does not smell any odor. Spreading the swine slurry with a conventional spreader shows $\sum$ value of 440, which means one feels unpleasant. The hose spreader shows $\sum$ value of 258, which lies in the limit one feels some odor and torment. Its combination with disk harrow has $\sum$ value 184, which means that a normal person can not smell any more. For the conventional spreader, the odor intensity indices from air dilution sensual test and 3 point odor bag as a sensual test were 66.9 and 35.4 respectively. On the other hand, the indices were 9.65 and 11.10 by hose spreader and its combination with disk harrow, which were lower than that of the regulation for industry. Therefore, the developed hose spreader showed an excellent effect on decreasing odor. The correlation between the results from odor tester and 3 point odor bag has shown 0.997 by swine slurry.

  • PDF