• Title/Summary/Keyword: Environmental Sample

Search Result 2,584, Processing Time 0.032 seconds

Application of a Gas Chromatography/Luminol Detection System for Peroxyacetyl Nitrate Airborne Measurement

  • Khang, Bumju;Ahn, Joon Young;Song, Dasol;Lee, Gangwoong
    • Asian Journal of Atmospheric Environment
    • /
    • v.7 no.2
    • /
    • pp.105-113
    • /
    • 2013
  • We constructed and tested an airborne peroxyacetyl nitrate (PAN) monitoring system based on luminol chemiluminescence detection with fast gas chromatography. This system allowed for simultaneous measurement of PAN and nitrogen dioxide ($NO_2$) with a time resolution of <2 min. Actual sample masses within the fixed volume sample loop at various altitudes and temperatures were adjusted to standard atmosphere, using measured pressures and temperatures. The airborne PAN measurement system was evaluated during two field studies above the southern Korean Peninsula in August and October 2009. The detection limit based on the ISO approach was 0.035 ppbv PAN, well below the observed concentrations of 0.185-1.49 ppbv during these studies. Under these conditions, the PAN mixing ratios were positively correlated with $O_x$ ($O_x=O_3+NO_2$), with slopes varying between 0.014 and 0.033 and intercepts between 22.6 and 55.1 ppbv $O_x$. The intercepts corresponded roughly to background $O_x$ mixing ratios in central Europe; however, the slopes were above the range of slopes reported in other studies. We also enhanced the durability, safety, and ease of maintenance of the PAN monitoring system by redesigning the structure of the conventional luminol cell.

The influence on air quality of the surroundings by the facility of the district heating (집단 에너지 시설에 의한 주변 대기질 영향)

  • 연익준;주소영;이민희;손종렬;김광렬
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.2
    • /
    • pp.18-25
    • /
    • 2002
  • The comparison of the air quality with the evaluation of the environmental assessment before and after operations of the heat source and of the flue-gas desulfurization facilities were studied. First of all, several sites were selected for the representative sample points, and then they were examined air quality of the surroundings. The results were that TSP(total suspended particulate) analysis after an operation of the heat source facility was $74~81{\mu}g/m^3$, PM-10 was $31~94{\mu}g/m^3$, and $SO_2$concentration was 0.002~0.009ppm, respectively. As the result of examination to the concentrations of diffused pollutants, there was no relations between TSP concentration of sample points and the effect of air quality according to the heating source. When we compared the neighbored area of the heating source with the other area, the concentration of air pollutants after an operation of the facility of the heating source was similar to the heating source, the neighbored area, and the other area. So we concluded that there was no the effect of the air pollution by producted pollutants from the heating source.

Concentration Distribution of Polychlorinated Biphenyls(PCBs) in Urban Watershed (도심하천유역의 PCBs 농도 분포)

  • Kim, Hyun-Seung;Kim, Il-Kyu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.6
    • /
    • pp.757-766
    • /
    • 2012
  • In this study, we have examined concentration distribution and patterns of PCBs in waters, sediments and soils in an agricultural area of South Korea to investigate the relationship between PCBs sources and concentration levels. The concentration of PCBs in water samples were ranged from lower values below detection limit to 8.25 ug/L and the concentration of PCBs in sediment samples were ranged from lower values below detection limit to 76.67 ug/Kg. The concentration of PCBs in soil samples were ranged from lower values below detection limit to 23.51 ug/Kg. These contamination levels were far below the guideline values suggested for environmental quality assessment. The homologue patterns in samples varied from sample to sample, but isomer patterns were very similar with each other. PCB-138 and PCB-153 were predominant congeners in the soil and sediment, which were similar to the results obtained from previous studies. With these results, the assessment of potential sources of PCBs contamination in the sediments of the Nakdong river basin was performed. The principal components were extracted by Principal Component Analysis(PCA). As the result of PCA, it could be expected that PCBs in samples of this study were more affected by PCB products than combustion processes and mostly affected by already-known sources. The PCBs in the soil and sediment samples were related with commercial PCB products.

The Pattern of PCBs Level in Adipose Tissue and Serum of Breast Cancer and Normal Women (유방암 환자와 정상여성의 혈액 및 지방조직 중 PCBs 형태에 관한 연구)

  • 노영만;이강숙;구정완;장경순
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.2
    • /
    • pp.29-37
    • /
    • 2003
  • The purpose of this study was to identify the distribution of non-ortho and mono-ortho PCB congeners and homologues in adipose tissues and sera of women with breast cancer. The collected samples were 25 adipose tissues and 33 sera from women with breast cancer. The samples from the control group were 49 adipose tissues and 52 sera. The levels of three non-ortho and eight mono-ortho PCBs identified in adipose tissue and serum samples were determined by GC/MSD and GC/ECD analyses. Non-ortho and mono-ortho PCB congeners were more dominant in the control group than in the case group for serum samples. The Tetra-PCB and the Hexa-, Hepta-PCB were more dominant in tale and control groups, respectively. The level of PCB homologues in normal women was similar to that of the normal human milk samples. However, the levels of PCB homologues from breast cancer patients were almost same the level of sample from environment. As a result of this study, it is suggested that breast cancer could be related to environmental factors such as PCB level in stack gas and soil sample. More extended research should be to verify this result.

Preparation of SiO2-Coated TiO2 Composite Materials with Enhanced Photocatalytic Activity Under UV Light

  • Hu, Shaozheng;Li, Fayun;Fan, Zhiping
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.6
    • /
    • pp.1895-1899
    • /
    • 2012
  • $SiO_2$-coated $TiO_2$ composite materials with enhanced photocatalytic activity under UV light was prepared by a simple catalytic hydrolysis method. XRD, TEM, UV-vis spectroscopy, Photoluminescence, FT-IR and XP spectra were used to characterize the prepared samples. The obvious shell-core structure was shown for obtained $SiO_2$@$TiO_2$ sample. The average thickness of the $SiO_2$ coating layer was 2-3 nm. The interaction between $SiO_2$ and $TiO_2$ restrained the recombination of excited electrons and holes. The photocatalytic activities were tested in the degradation of an aqueous solution of a reactive dyestuff, methylene blue, under UV light. The photocatalytic activity of $SiO_2$@$TiO_2$ was much higher than that of P25 and mechanical mixing sample $SiO_2/TiO_2$. The possible mechanism for the photocatalysis was proposed.

LEAD LEACHABILITY FROM QUICKLIME TREATED SOILS IN A DIFFUSION CONTROLLED ENVIRONMENT

  • Moon, Deok-Hyun
    • Environmental Engineering Research
    • /
    • v.10 no.3
    • /
    • pp.112-121
    • /
    • 2005
  • The effectiveness of quicklime-based stabilization/solidification (S/S) in immobilizing lead (Pb) was assessed by performing semi-dynamic leaching tests (ANS16.1). In order to simulate landfill leaching conditions, the ANS 16.1 test was modified by using 0.014 N acetic acid (pH = 3.25) instead of distilled water. Artificial soil samples as well as field soil samples contaminated with Pb were tested. The effectiveness of quicklime treatment was evaluated by determining diffusion coefficients ($D_e$) and leachability indices (LX). A model developed by de Groot and van der Sloat was used to elucidate the controlling Pb leaching mechanisms. Overall, upon quicklime treatment Pb leachability was significantly reduced in a]l of the samples tested. The mean LX values were higher than 9 for an artificial soil sample containing 30% kaolinite treated with 10% quicklime and for a field soil sample treated with 10% quicklime, which suggests that S/S treated soils can be considered acceptable for "controlled utilization". Moreover, quicklime treatment was more effective in artificially contaminated soil with high kaolinite content (30%), indicating the amount of clay plays an important role in the success of the treatment. The controlling Pb leaching mechanism was found to be diffusion, in all quicklime treated samples.

Stability and Environmental Safety of a Nanosized Agroformulation by Using Gamma-irradiation Technique (감마선을 이용하여 제조한 농업용 나노제제의 보존성 및 환경안전성)

  • Park, Hae-Jun;Kim, Hwa-Jung;Choi, Jin-Su
    • Journal of Radiation Industry
    • /
    • v.7 no.2_3
    • /
    • pp.171-176
    • /
    • 2013
  • In previous study, the novel nanosized curdlan-silica complex for a sustain-releasing effect was developed by using gamma-irradiation. It can be applicable to use in various sustainr-eleasing formulation in agriculture industry. This study was conducted to investigate its storage stability and environmental toxicity in an accelerated condition. The complex samples were treated with high temperature condition ($65^{\circ}C$) during 3 weeks, and then sustain-releasing property of complex was verified thereby using Ion Chromatography on a weekly basis. The morphology of the complex was characterized using scanning electron microscopy (SEM). Results of Ion Chromatography analysis showed that sample treated for 3 weeks was similar to sustain-releasing pattern of non-treatment sample. We verify concluded that the complex is able to keep its sustain-releasing property and sustained-releasing in 3 years. Also the formulation has no environmental toxicity.

The Effect of Consumers′ Environmental Conservation Behavior on the Purchase of Pro-Environmental and Used Products (소비자의 환경보전행동이 환경제품 및 중고제품 구매에 미치는 영향)

  • Huh Kyungok
    • Journal of the Korean Home Economics Association
    • /
    • v.42 no.9
    • /
    • pp.85-97
    • /
    • 2004
  • The effect of consumers' environmental conservation behavior on the purchase of pro-environmental and used products. This study utilized a representative, large data sample to determine consumers' environmental conservation behavior, and purchase of pro-environmental and used products. Differences in these behavioral traits were investigated by socio-demographic variables. In addition, this study investigated the effect of consumers' environmental conservation behavior on the purchase of pro-environmental and used product. The major result were as follows. First, the level of consumers' environmental conservation behavior was low, and consumers did not buy pro-environmental and used products frequently. Second, unemployed married women, consumers with very low or high level of education and high income, consumers older than 40's, and consumers living in apartments showed lower levels of environmental conservation behavior. Third, consumers who were married, dissatisfied with their environmental living conditions, or irrational were more likely to buy pro-environmental products. Men, young, and rational consumers were more likely to buy used products. On the other hand, the level of environmental behavior did not influence the purchase of pro-environmental and used products. The high level of behavior for environmental conservation did not result the purchase of pro-environmental and used products.

A Study on the Quantification and Chracterization of Endocrine Disruptor Bisphenoi-A Leaching from Epoxy Resin (에폭시 수지 용출물질에서의 내분비계장애물질 Bisphenol-A의 정량과 용출특성 파악)

  • Bae, Bumhan;Choi, Myoung-soo;Lim, Nam-woong;Jeong, Jae-hoon
    • Journal of Korean Society on Water Environment
    • /
    • v.16 no.4
    • /
    • pp.469-477
    • /
    • 2000
  • Bisphenol-A (BPA), a known endocrine disruptor, is a main building block of epoxy resin which is widely used as a coating agent in residential water storage tanks. Therefore, BPA leaching from the epoxy resin may have adverse effects on human health. The possibility of BPA leaching from three epoxy resins were tested with a modified KS D 8502 method at 20, 50, 75 and $100^{\circ}C$ in deionized water and the specified test water, respectively. BPA leached to the test water was identified using GC-MS and quantified with GC-FID after a sequential extraction and concentration. The results showed that BPA leaching has occurred in all three samples tested. The quantify of BPA leaching from unit area of epoxy resin coating was in the range of $10.677{\sim}273.120{\mu}g/m^2$ for sample A, 29.737~1734.045 for sample B and 52.857~548.778 for sample C depending on the test temperature, respectively. In general, the amount of BPA leaching increased as the water temperature increases. This result implies a higher risk of BPA leaching to drinking water during a hot summer season. In addition, microbial growth, measured by colony forming units, in epoxy coated water tanks was higher than that in a stainless steel tank suggesting that compounds leaching from epoxy resin may support the growth of microorganisms in a residential water holding tank.

  • PDF

Field Validation of an IC/Visible Spectrophotometry Method for the Determination of Cr(VI) in Mist (미스트중 6가 크롬 측정을 위한 IC/Visible Spectrophotometry 방법 (Shin & Paik′s Method)의 현장 평가)

  • 신용철;백남원;김상우;김선자;이유미
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2002.04a
    • /
    • pp.40.1-43
    • /
    • 2002
  • The purpose of this study was to evaluate a new sampling and analytical method for the determination of hexavalent chromium, Cr(VI) in mist from field plating operation. The Procedures of this new method (Shin & Paik's Method) are as the following: Airborne hexavalent chromium is collected on polyvinyl chloride (PVC) filter according to the National Institute for Occupational Safety and Health (NIOSH) Method 7600, and the filter sample is placed in a screw-capped vial and soaked with 2% NaOH/3% Na₂CO₃ solution immediately after sampling. The Cr(VI) sample is analyzed by ion chromatography/visible spectrophotometry (IC/VS) according to the U.S. Environmental Protection Agency (EPA) Method 218.6. The airborne Cr(VI) concentrations measured by this method were compared with those determined by three reference methods: One (NIOSH/EPA Method) consisted of sampling airborne Cr(VI) on PVC filters and storing the sample filters in screw-capped vials according to the NIOSH method, and analyzing Cr(VI) in samples using IC/VS according to the EPA method. The second method (Impinger Method/NaHCO₃) consisted of absorbing airborne Cr(VI) into 0.02 MN/sub a/Hco₃ solution in midget impinger, and analyzing the Cr(VI) in samples using IC/VS. The third method was the OSHA Method Id-215. Using these four different methods, four replicates of air samples were collected at an electroplating process and analyzed simultaneously. Two-way ANOVA and Paired t-test were used to test difference among values determined by the methods. There was no significant difference and a strong correlation (r/sup 2/=0.99) between Cr(VI) concentrations measured by the shin & Paik's Method and an impinger method (p>0.05). However, Cr(VI) concentrations determined by Shin & Paik's Method were Significantly different form those by the NIOSH/EPA Method (p<0.05) or the OSHA method (p<0.05). The Cr(VI) concentrations of Shin & Paik's Method were Significantly higher than those of the NIOSH/EPA Method or the OSHA method. We concluded that the Shin & Paik's Method could prevent Cr(VI) losses caused by reduction and give more reliable results of airborne Cr(VI) concentrations in work environments.

  • PDF