• Title/Summary/Keyword: Environmental Quality Evaluation

Search Result 1,244, Processing Time 0.034 seconds

A Study on the Mock up Test for Reduction of HCHO Using the Functional Gypsum Board (기능성 석고보드의 폼알데히드(HCHO) 저감성능 평가를 위한 실물시험(Mock up test)연구)

  • Kim, Hea-Jeong;Song, Kyoo-Dong;Lee, Yun-Gyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.12
    • /
    • pp.814-819
    • /
    • 2008
  • The purpose of this study was developing the building materials for creation the comfortable IAQ. By reducing formaldehyde(HCHO) known as the main factors of Sick House Syndrome. This material must be revealed the physical and eco-friendly performance, so this study set up the basic standards for building materials. The source of physical performance evaluation is Korea Industrial Standards and the base of environmental ability is the Eco Label considering certificated system related to an apartment house. Because the developed material was satisfied with the established standards, it was tested in mock-up room for obtaining the real date from indoor air. The mock-up test was conducted according environmental standard method for indoor air Quality of the ministry of environment. The result of this study were as follows; the functional building materials had a effect to reduce the formaldehyde concentration for a initial period without wall paper, so additional development is needed for application with the wall paper and the available period.

A Study on the Design of Uniform Quality Guaranteed Streaming Video System (균일 화질 보장을 위한 스트리밍 비디오 시스템 설계에 관한 연구)

  • Park, Young-Hwan;Park, Chan-Khon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.18 no.8
    • /
    • pp.53-64
    • /
    • 2013
  • The existing research on the QoS of the Streaming video system(SVS) adjust the video stream being sent from the network perspective, the focus is to prevent data loss and delay. The other hand, changing the quality of the video stream will not receive the guaranteed QoS from the perspective of the users who want uniform quality. In order to solve these problems, this paper applied to ensure that the benefits in the amount of bits per frame occurs Encoder CBR streaming video is kept constant and uniform picture quality advantages of VBR streaming video VBR to CBR Encoder and CBR to VBR Decoder, Video was designed to control the playback stream for And to ensure a uniform quality of the user based on the design and implementation of uniform quality guaranteed SVS. PSNR evaluated for several characteristics of the sample video to demonstrate the superiority of the SVS ensure uniform quality, the proposed Performance evaluation of the SVS ensure uniform quality CBW the ABR from 100% to ensure uniform image quality from 85% to environmental excellence is proved.

An Evaluation of Energy Quality for Distributed Powersystem (분산형 발전설비 병열운전 에너지 품질평가)

  • Hur, Kwang-Beom;Park, Jung-Keuk;Yoon, Gi-Gab;Rhim, Sang-Kyu;Choi, In-Kyu
    • Journal of Energy Engineering
    • /
    • v.19 no.1
    • /
    • pp.8-15
    • /
    • 2010
  • As environmental friendly energy system, distributed micro gasturbine is focused on new energy source for overcoming brand new construction area of power generation. This distributed micro gasturbine system has the powerful characteristics as belows; 1) environmental friendly features NOx < 9 ppm, noise < 65 db 2) various fuel flexbility which is used such as natural gas, diesel, low calory new & renewable fuel, kerosene. 3) high specific output power based on small area and is avilable for very easy and compact installation. There are many new installation sites in USA and Japan from 1998. On the other hand the exhisting large power system was constructued by the sea side, this compact power system is now installed by enduser in downtown area and supplying combined heat & power, has the various apllication on-site power generation. In recently, there is the very important issue for new & reliablbe energy development and spreading out. This paper represent as belows for important system characteristics; 1) grid connection modeling 2) system operation characteristics 3) on-site operation result and evaluation output of power quality analysis.

A Study on the Compatibility of Korean Temperature Guidelines for Stockpile Material Environmental Test (저장물자 환경시험을 위한 한국적 온도기준 적합성 연구)

  • Lee, Il Ro;Byun, Kisik;Cho, Sung-Yong;Kim, Kyung Pil;Park, Jae Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.8
    • /
    • pp.187-194
    • /
    • 2020
  • The T&E (Test and Evaluation) results were applied for a judgment basis to decide the developmental process of system engineering for efficient weapon system R&D (Research and Development). During the OT&E (Operational Test and Evaluation) and DT&E (Development Test and Evaluation), an environmental test is essential for weapon system development owing to their highly exposed operational conditions. Based on the MIL-STD-810, MIL-HDBK-310, and AECTP 200, the ROK armed forces recommended operating temperatures for the ROK weapon system and applied this to the DT&E and OT&E. This study examined the compatibility of Korean temperature guidelines for stockpile material considering recent climate change. Moreover, this study analyzed the data from hourly measured temperatures on 101 observatories during 60 years, from 1960 to 2020, and percentage (0.5%, 1%, 5%, and 10%) and the 𝜎 (3𝜎, 2𝜎, and 1𝜎) frequency of occurrence on rigorous hot (August) and cold (January) periods, respectively. The results indicate that the highest temperature was 41℃, and the 0.5% frequency of occurrence was 37.0℃. In the case of the cold period, the lowest temperature was -32.6℃ and the 0.5% frequency of occurrence was -21.1℃. By considering the previously recommended operating temperature range for a general ground system, -30 ~ 40℃, regional operation probability is recognized 99.999%. Despite the recent abnormal climate change from global warming, the Korean temperature guidelines are compatible with the stockpile material environmental test.

Evaluation of Water Quality Characteristics of Floor Fountains in Gwangju (광주지역 바닥분수의 수질특성 평가)

  • Kim, Jong-Min;Kim, Ha-Ram;Jang, Seo-Eun;Choi, Yeong-Seop;Kang, Yu-Mi;Jung, Sook-Kyoung;Cho, Young-Gwan;Kim, Eun-Sun
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.2
    • /
    • pp.143-156
    • /
    • 2017
  • The purpose of this study was to investigate water quality through a field survey at six floor fountain sites. The floor fountain facilities were designed and operated in such a way that tap water was stored in a water tank and recycled repeatedly. The water tank was cleaned once or twice per week in the summer. The number of facility users was low during the day due to sweltering heat, but up to 40 people, mainly children, were using them around 8 pm. Since the operation time was as short as 30 minutes, it is considered necessary to extend it for at least one hour for the number of users. As a result of the water quality test of the reservoir tank prior to operation after cleaning, it was measured to be within drinking water quality standards at the six facilities. As a result of the water quality test after use, ammonia nitrogen was measured to be 1.45 mg/L at Site IV. This exceeded the drinking water quality standard of 0.5 mg/L. In the case of turbidity, two cases exceed at 7.38 and 4.52 NTU when applying 4 NTU as the water quality standard for waterscape facilities. Twenty-eight cases exceed the standard of drinking water quality. The result of microbiological tests, at five sites excepting Site I, where disinfectant was injected, was that the maximum total colony count was 180,000 CFU/mL, total coliforms was 2,100,000 CFU/100 mL, fecal coliforms was 4,600 CFU/100 mL, Escherichia coli was 170 MPN/100 mL and Enterococcus was 100 CFU/100 mL. This exceeded the water quality standards of drinking water. Children are very likely to inhale because the water spews from below and falls from above, so it is necessary to apply water quality standards for ammonia nitrogen, turbidity and microbes. Current floor fountain facilities are highly susceptible to disease caused by microbial contamination because of water cycling and reuse, so it is necessary to change the water every day, clean the water tank, and perform chlorination. Therefore, it is necessary to inject calcium hypochlorite according to the free chlorine water quality standard of swimming pools with a different water tank capacity. In addition, facilities should be improved to prevent the reuse of water by installing the water tank at a separate location.

Change in Geochemical Characteristics of Surface Sediments in the Nakdong River Main Stream (낙동강 본류에 분포하는 표층 퇴적물의 지화학적 특성 변화)

  • Kim, Shin;Lee, Kwonchul;Kim, Jueon;Jung, Kangyoung;Ahn, Jungmin;Kim, Hyounggeun;Lee, Injung;Shin, Dongseok;Yang, Deukseok
    • Journal of Environmental Science International
    • /
    • v.26 no.3
    • /
    • pp.311-324
    • /
    • 2017
  • To certificate change in the geochemical characteristics of surface sediments in the main stream of the Nakdong River, surface sediments from 12 sampling sites during the first and second half year (total 24 sampling sites) were collected and analyzed for grain size, ignition loss, total organic carbon and heavy metal content. Surface sediments mainly composed of sand (coarse and medium sand) and fining changed from the first half to the second half of the year. Ignition loss, total organic carbon and heavy metals content increased in the second half of the year. Some heavy metals (Zn, Ni and Cu) were found to be at the lowest effect levels according to Ontario sediment quality guidelines. Additionally, most heavy metals were found to be at the non polluted level and level I according to USEPA sediment quality standards and National Institute of Environmental Research sediment pollution evaluation standard, respectively. The enrichment factor (< 1) and index of geoaccmulation (< 0) were non polluted in the study area. The correlation analysis results showed that ignition loss, total organic carbon and heavy metal content were highly correlated with grain size. Regarding changes in geochemical characteristics of surface sediments in the study area, grain size fine and organic matter and heavy metal content increased in the second half year. Nonetheless these results indicated pollution levels that did not adversely affect the benthos.

Evaluation of Industrial Hygiene Laboratories by on-Site Investigation for Revised Quality Control System (개정된 정도관리제도를 적용한 작업환경측정기관의 실험실 현장 평가)

  • Shin, Jung-Ah;Yi, Gwang-Yong;Park, Seung-Hyun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.3
    • /
    • pp.243-249
    • /
    • 2013
  • Objectives: This study assessed the status of domestic industrial hygiene laboratories using data from on-site investigation for revision of quality control systems in 2012-2013. Methods: The target laboratories were 60 industrial hygiene laboratories chosen by random selection and nationwide distribution which had participated in on-site investigations for revision of quality control systems from March 2012 to August 2013. The investigation was performed on-site following standard quality control procedures. The score between each group was compared using Mann-Whitney and Kruskal-Wallis tests, and the correlation between analytical career, sex, academic major of analyst and score of analytical performance was expressed as Spearman's rank correlation coefficient. Results: The assessment revealed that the items to be improved, in sequence, were effort at staff training (score 65.5), ability to calculate data (score 73.4), establishment of internal quality control guidelines (score 75.7), laboratory facilities (score 77.1), degree of understanding and skill at gas chromatography (score 77.1). Analysis performance showed a positive correlation with career of analyst (r=0.56, p<0.01). Conclusions: The practice of on-site investigation for quality control systems showed the current status of industrial hygiene laboratories in the first trial. There were many laboratories which needed improvement and development of analytical systems. This assessment can provide information for the systematic operation and improvement of facilities at each laboratory. Further practice of this investigation will lead to a proficiency testing and accreditation system for autonomous quality control as is the practice in many countries, rather than mandatory practice by legal regulation.

Review of Rice Quality under Various Growth and Storage Conditions and its Evaluation using Spectroscopic Technology

  • Joshi, Ritu;Mo, Changyeun;Lee, Wang-Hee;Lee, Seung Hyun;Cho, Byoung-Kwan
    • Journal of Biosystems Engineering
    • /
    • v.40 no.2
    • /
    • pp.124-136
    • /
    • 2015
  • Purpose: Grain quality is a general concept that covers many characteristics, ranging from physical to biochemical and physiochemical properties. Rice aging during storage is currently a challenge in the rice industry, and is a complicated process involving changes in all of the above properties. Spectroscopic techniques can be used to obtain information on the quality of rice samples in a non-destructive manner. Methods: The objective of this review was to highlight the factors that contribute to rice quality and aging, and to describe various spectroscopic modalities, particularly vibrational and hyperspectral imaging, for the assessment of rice quality. Results: Starch and protein are the main components of the rice endosperm, and are therefore key factors contributing to eating and cooking quality. While the overall starch, protein, and lipid content in the rice grain remains essentially unchanged during storage, structural changes do occur. These changes affect pasting and gel properties, and ultimately the flavor of cooked rice. In addition, grain quality is significantly affected by growing and environmental conditions, such as water availability, temperature, fertilizer application, and salinity stress. These properties can be evaluated using spectroscopic techniques, and rice samples can be discriminated by using multivariate statistical analysis methods. Conclusion: Hyperspectral imaging and vibrational spectroscopy techniques have good potential for determining rice quality properties in a non-invasive manner, i.e., not requiring the introduction of instruments into the rice grain.

An Analysis of the Water Quality Improvement Measures and Evaluation of Wonju Stream (원주천 수질개선 방안 및 개선효과 평가)

  • Kum, Donghyuk;Shin, Minhwan;Yu, Nayeong;Lee, Seolo;Kim, Dongjin;Sung, Younsoo;Lee, Sang Soo
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.63 no.1
    • /
    • pp.61-73
    • /
    • 2021
  • Recently, the deterioration of water quality in Wonju stream has been reported due to the increase in diverse pollution sources along with community development and urbanization. Various types of attempts with a huge budget were made for better water quality so far, but its effectiveness is still doubted. In order to establish site-oriented measures for water quality improvement, the topographic and hydrologic factors were evaluated based on site inspection and survey. As the major streams merged into the Wonju stream, the Hwa and Heungyang streams were found to have higher pollution loads and contributions compared to other streams due to the scattered livestock farms and industries, and vulnerable land use. Notably, the discharge water from the Wonju Public Sewage Treatment Plant had the highest level of pollution load, impacting on the water quality of Wonju Stream. According to the SWAT model as water quality measures, the improvement effect of water quality in this treatment plant can be reached to the reductions in BOD 11.06%, T-N 23.56%, T-P 10.60% when the proper managements applied, whereas the improvement of water quality would be 3.89%, 1.23%, and 3.32% for BOD, T-N, T-P, respectively, for the industries. The reduction of the livestock industry was generally very high as a pollution source, but it was not much higher at the end of Wonju Stream than other measures. These results recommended that the water q uality improvement measures should be designated for each upper-middle-lower section in Wonju stream.

The Case Study for Evaluation on the Solar America Initiative Program Using General Evaluation program (General program evaluation을 이용한 미국 태양광 보급정책 평가사례연구)

  • Lee, You-Ah;Kim, Yeon-Bae
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.301-301
    • /
    • 2009
  • The General program evaluation guide is intended for use by managers of both deployment and R&D programs within the U.S. Department of Energy's Office of Energy Efficiency and Renewable Energy (EERE), although most of the examples of evaluations pertain to deployment programs(EERE,2006). It could help managers determine what kinds of timely adjustments may be needed in program design or implementation to improve the rate or quality of achievement relative to the committed resources. To consider the adaptation of the method in Korea, we have studied the evaluation case for solar america initiative using cost-benefit evaluation. The President's Solar America Initiative (SAI) was launched in January 2006 as part of the administration's Advanced Energy Initiative. The SAI has a goal of installing 5-10 GW of photovoltaic (PV) systems in the U.S. by 2015 and 70-100 GW of PV systems in the U.S. by 2030. The evaluation report presents estimates of the potential benefits should the SAI PV installation goals be achieved. For this analysis, the areas researched include energy, economic, and environmental benefits. As a result, research suggests that 500 MW of PV may have been enough to avoid lackout. The ability of PV to prevent specific blackouts will depend on very specific information on where the PV installations are installed and their ability to relieve pressure on the high stress points on the grid. While this level of detail is outside the scope of this study, it appears that there will be some potential benefit for blackout prevention should the SAI PV goals be achieved.

  • PDF