• Title/Summary/Keyword: Environmental Quality Evaluation

Search Result 1,239, Processing Time 0.03 seconds

Evaluation of Air Quality and Site Feasibility for the Construction of the Incineration Facilities in Won Ju City (원주시 소각시설의 입지와 주변지역의 대기질예측에 관한 연구 - 입지여건의 평가를 중심으로)

  • 송동웅;김기현
    • Journal of Environmental Science International
    • /
    • v.9 no.1
    • /
    • pp.65-74
    • /
    • 2000
  • In this study, we investigated the site feasibility for the construction of the incineration facilities in Won Ju City. To assess the environmental impact of its construction, we examined the current status of air quality in the selected candidate sites and predicted the extent of air quality change upon its operation through modification of stack type. If the stack height is assumed to be 70 m, the concentrations of $SO_2$ and dioxin in the surrounding area were predicted to increase by 0.05 ppb and 0.09 pg/$m^3$, respectively. The impact of its operation was assessed and compared among different sites. According to this analysis, more impact was expected from the residential area for the Dan-Gye site than from agricultural areas of the Kwan-Sul and Sa-Je site.

  • PDF

Stream Classification Based on the Ecological Characteristics for Effective Stream Management - In the Case of Nakdong River - (효율적인 하천관리를 위한 하천생태 특성을 고려한 유형 분류 - 낙동강수계를 대상으로 -)

  • Lee, Yoo-Kyoung;Lee, Sang-Woo
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.15 no.5
    • /
    • pp.103-114
    • /
    • 2012
  • The purpose of this research is classifying stream into different types depending on various factor from the perspective of stream corridor restoration and using it as basic data, which are used to consider efficient management and planning for the healthy stream according to the characteristic by types. In this study, 130 points of location of the Nakdong river basin which consist of various geographic factors have been chosen and hierarchical cluster analysis has been carried out in these points by using biological and physiochemical factors whose health can be considered to be predicted and evaluated. As a result of cluster analysis, there were three divided types. Type A whose biology and water quality are considered the best was the highest in forest area percentage so that it was classified into natural stream. Type B was classified into a rural region stream with a mixture of urban and agricultural region. Type C, with the most damaged water quality and biology health had the most urban region surface area and was named as urban region stream. Moreover, an overall restoration strategy according to characteristic by stream types was set. By the results of correlation analysis on factors, water quality showed a high correlation with biological properties and was affected by surrounding land usage. In evaluation of streams, it proves the need to consider not only other habitat's geographical and biological factors but also the water quality and land usage factors. There needs to be further research on stream ecosystem functionality factors and structural aspects by using a more objective and total evaluation result in selecting additional index and various other specific classification methods by stream types and its restoration strategies.

New System for Environmental Management Evaluation

  • Kametani, Tsuyoshi
    • International Journal of Quality Innovation
    • /
    • v.5 no.1
    • /
    • pp.23-33
    • /
    • 2004
  • In Japan, where ISO14001 certifications have passed the 10,000 mark, the need for environmental management has taken firm root among companies. However, in the small-and medium-enterprise sector, and among tiny businesses, there are firms not obtaining ISO certification due to their concern about human resources and increased work load. On the other hand, among businesses that have already succeeded in gaining ISO certification. one does not sense any growth with regard to the continual improvement. Voices from certain quarters indicate there is a lack of incentive to keep on improving. With this background, we herewith present a new system to evaluate the level of environmental management in a company by means of a 5-step system.

A Study on the Environmental Improvement in the Interior Construction Fields with the check-list (실내건축의 작업환경 개선을 위한 기본적 관리방안에 관한 연구)

  • 이용의
    • Korean Institute of Interior Design Journal
    • /
    • no.9
    • /
    • pp.10-17
    • /
    • 1996
  • With the ever-increasing important of high-speed information in society as we move towards the 21 st century. Interior design and it's working condition has been changed a great deal included a sort of each special character and make a difference against the others. It used to be find a great poles asunder of worker's safety and project quality according to the environmental dimension of interior construction field as if they should be a pleasantness or poor condition. This research aimed to improvement of environmental construction field of interior with construction engineers and particular interior labors in 4 phases as : ⅠThe preparatory phase : -Secure a Budget, Environmental safety supervisor -Fix of Design quality, Construction period. -Choice of Construction method, Sub constructing Ⅱ. Starting work phase ; -Capacity , Safety of temporary power line. -Carriage, Stock of Material -Safety of Electronic tools, -Personal protector. Ⅲ. Working period ; -Ventilation, I illumination of working place. -Measurement of environmental working condition Ⅳ.Finish working phase ; -Analysis of measurement data. -Evaluation and making up for the weak point. -Keeping data.

  • PDF

A Study on Statistical Parameters for the Evaluation of Regional Air Quality Modeling Results - Focused on Fine Dust Modeling - (지역규모 대기질 모델 결과 평가를 위한 통계 검증지표 활용 - 미세먼지 모델링을 중심으로 -)

  • Kim, Cheol-Hee;Lee, Sang-Hyun;Jang, Min;Chun, Sungnam;Kang, Suji;Ko, Kwang-Kun;Lee, Jong-Jae;Lee, Hyo-Jung
    • Journal of Environmental Impact Assessment
    • /
    • v.29 no.4
    • /
    • pp.272-285
    • /
    • 2020
  • We investigated statistical evaluation parameters for 3D meteorological and air quality models and selected several quantitative indicator references, and summarized the reference values of the statistical parameters for domestic air quality modeling researcher. The finally selected 9 statistical parameters are MB (Mean Bias), ME (Mean Error), MNB (Mean Normalized Bias Error), MNE (Mean Absolute Gross Error), RMSE (Root Mean Square Error), IOA (Index of Agreement), R (Correlation Coefficient), FE (Fractional Error), FB (Fractional Bias), and the associated reference values are summarized. The results showed that MB and ME have been widely used in evaluating the meteorological model output, and NMB and NME are most frequently used for air quality model results. In addition, discussed are the presentation diagrams such as Soccer Plot, Taylor diagram, and Q-Q (Quantile-Quantile) diagram. The current results from our study is expected to be effectively used as the statistical evaluation parameters suitable for situation in Korea considering various characteristics such as including the mountainous surface areas.

Evaluation of Water Quality in the Keum River using Statistics Analysis (통계분석 기법을 이용한 錦江水系의 水質評價)

  • Kim, Jong-Gu
    • Journal of Environmental Science International
    • /
    • v.11 no.12
    • /
    • pp.1281-1289
    • /
    • 2002
  • This study was conducted to evaluate water quality in the Keum River using multivariate analysis. The analysis data in Keum river made use of surveyed data by the ministry of environment from January 1994 to December 2001. Thirteen water quality parameter were determined on each sample. The results was summarized as follow; Water quality in the Keum River could be explained up to 71.39% by four factors which were included in loading of organic matter and nutrients by the tributaries (32.88%), seasonal variation (16.09%), loading of pathogenic bacteria by domestic sewage of Gapcheon (13.39%) and internal metabolism in estuary as lakes(9.03%). For spatial variation of factor score, four group was classified by each factor characterization. Station 1 and 2 was influenced by Daechung dam, station 3 was affected by domestic sewage of Gapcheon, station 10~12 was affected by estuary dyke and the rest station. The result of cluster analysis by station was classified into four group that has different water quality characteristics. In monthly cluster analysis, three group was classified according to seasonal characteristic. Also, in yearly cluster analysis, three group was classified. It is necessary to control the pollutant loadings by Gapcheon inflow domestic sewage in Daejeon city for the sake of water quality management of Keum river.

Non-destructive evaluation of concrete quality using PZT transducers

  • Tawie, R.;Lee, H.K.;Park, S.H.
    • Smart Structures and Systems
    • /
    • v.6 no.7
    • /
    • pp.851-866
    • /
    • 2010
  • This paper presents a new concept of using PZT (lead zircornate titanate) transducers as a non-destructive testing (NDT) tool for evaluating quality of concrete. Detection of defects in concrete is very important in order to check the integrity of concrete structures. The electro-mechanical impedance (EMI) response of PZT transducers bonded onto a concrete specimen can be used for evaluating local condition of the specimen. Measurements are carried out by electrically exciting the bonded PZT transducers at high frequency range and taking response measurements of the transducers. In this study, the compression test results showed that concrete specimens without sufficient compaction are likely to fall below the desired strength. In addition, the strength of concrete was greatly reduced as the voids in concrete were increased. It was found that the root mean square deviation (RMSD) values yielded between the EMI signatures for concrete specimens in dry and saturated states showed good agreement with the specimens' compressive strength and permeable voids. A quality metric was introduced for predicting the quality of concrete based on the dry-saturated state of concrete specimens. The simplicity of the method and the current development towards low cost and portable impedance measuring system, offer an advantage over other NDE methods for evaluating concrete quality.

Quality Assurance and Quality Control method for Volatile Organic Compounds measured in the Photochemical Assessment Monitoring Station (광화학측정망에서 측정한 휘발성유기화합물의 정도관리 방법)

  • Shin, Hye-Jung;Kim, Jong-Choon;Kim, Yong-Pyo
    • Particle and aerosol research
    • /
    • v.7 no.1
    • /
    • pp.31-44
    • /
    • 2011
  • The hourly volatile organic compounds(VOCs) concentrations between 2005 and 2008 at Bulgwang photochemical assessment monitoring station were investigated to establish a method for quality assurance and quality control(QA/QC) procedure. Systematic error, erratic error, and random error, which was manifested by outlier and highly fluctuated data, were checked and removed. About 17.3% of the raw data were excluded according to the proposed QA/QC procedure. After QA/QC, relative standard deviation for representing 15 species concentrations decreased from 94.7-548.0% to 63.4-125.8%, implying the QA/QC procedure is proper. For further evaluation about the adequacy of QA/QC procedure, principal components analysis(PCA) was carried out. When the data after QA/QC procedure was used for PCA, the extracted principal components were different from the result from the raw data and could logically explain the major emission sources(gasoline vapor, vehicle exhaust, and solvent usage). The QA/QC procedure based on the concept of errors is inferred to proper to be applied on VOCs. However, an additional QA/QC step considering the relationship between species in the atmosphere needs to be further considered.

Establishment of Best Management Indicator for Sustainable Agricultural Water Quality using Delphi Survey Method

  • Kim, Min-Kyeong;Jung, Goo-Bok;Hong, Seong-Chang;Kim, Myung-Hyun;Choi, Soon-Kun;Kwon, Soon-Ik;So, Kyu-Ho
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.48 no.5
    • /
    • pp.379-383
    • /
    • 2015
  • Indicators of environmental conditions describe the state of the environment and the quantity and quality of natural resources. This study deduced the evaluation items to assess each sub-indicator for agricultural water quality and conducted the surveying using the Delphi method based on agricultural water quality experts. Considering its importance, environmental, state, and management indicators showed that state indicator such as COD concentration for surface water and $NO_3-N$ concentration for groundwater was ranked as first and followed by amount of fertilizer. Its indicators were correlated with state and environmental indicators in surface water and groundwater. The best management indicators were calculated to assess the agricultural surface water and ground water quality. The indicator could be used in established policies for management and conservation of water resources.

Evaluation of Rapid filtration System with Particle Size Distribution and Turbidity in Different Effective Sizes

  • Park, J.A.;Eo, S.M.;Shin, J.S.;Kim, M.H.;Yu, M.J.;Chung, S.H.
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.06a
    • /
    • pp.381-385
    • /
    • 2005
  • Characterization of particle behavior is becoming more important in performance evaluation of water treatment system as well as in operation of the system because conventional parameter, turbidity has lack of explaining ability on small sized microorganisms such like Cryptosporidium etc. Accordingly, particle counter has been introduced in evaluation and operation of the treatment system. However researches on the relationship between turbidity, particle count and/or different sand/anthracite sizes have not been concurrent. Therefore in this study, the relationship was investigated to improve performance evaluation of sand filter so as to help choosing sand/anthracite effective size as a design parameter of water treatment facility. According to the results, too small or too large effective size media filter reached to turbidity limit(0.1 NTU)earlier. However, because shallow sand layer may cause early breakthrough, the depth of sand layer should be provided enough in order to compromise water quality and productivity.

  • PDF