• Title/Summary/Keyword: Environment conversion factor

Search Result 63, Processing Time 0.023 seconds

The Strategy Development of the Restaurant Industry through the AHP Analysis: Focusing on the Digital Conversion and Non-Contact Service after COVID-19 Pandemic (AHP 기법을 활용한 외식산업의 발전 전략에 관한 연구: COVID-19 팬더믹 이후의 디지털, 비대면 전환에 대한 인식)

  • Lee, Bong-Shik;Park, Min-Jae
    • Asia-Pacific Journal of Business
    • /
    • v.12 no.4
    • /
    • pp.271-288
    • /
    • 2021
  • Purpose - The purpose of this study is to identify the critical factors that restaurant management should consider strategically when making a decision after COVID-19 under the digital transformation and non-contact service expansions environment. Design/methodology/approach - The thirty six experts and managers who have 5 years or more experience in restaurant industry in Korea participate this study. The Analytic Hierarchy Process (AHP) and SER-M were used to analyze the experts' opinion Findings - As a result of the analysis, 'management environment' (0.313) showed the highest relative importance priority, followed by 'brand (0.263)', 'management characteristics (0.254)', and 'physical factors (0.17)'. And, as for the sub-factor value, 'lifestyle (0.087)', 'awareness (0.084)', 'consumer desire (0.075)', and 'loyalty (0.068)' were ranked highest among the 19 influencing critical factors. Research implications or Originality - In the case of large restaurant enterprises, it is judged that the subject(CEO, Management) is actively pursuing a strategy to acquire the necessary resources for the given environment of digital transformation and customer demand for non-contact services. On the other hand, in the case of middle and small restaurant enterprises, it seems that they are fully aware of the demand for expansion of non-contact services and the digital transformation required in the post COVID-19 era, but information technology utilization ability, usage experience, technology acceptance ability, and education and training support for this are only available to large enterprises.

Current Status of Nanostructured Thermoelectric Materials for Mid-High Temperature Applications (나노구조 기반 중·고온용 열전소재 연구 동향)

  • Nam, Woo Hyun;Shin, Weon Ho;Cho, Jung Young;Seo, Won-Seon
    • Ceramist
    • /
    • v.22 no.2
    • /
    • pp.133-145
    • /
    • 2019
  • Thermoelectric energy conversion has attracted much attention because it can convert heat into electric power directly through solid state device and vice versa. Current research is aimed at increasing the thermoelectric figure of merit (ZT ) by improving the power factor and reducing the thermal conductivity. Although there have been significant progresses in increasing ZT of material systems composed of Bi, Te, Ge, Pb, and etc. over the last few decades, their relatively high cost, toxicity, and the scarcity have hindered further development of thermoelectrics to expand practical applications. In this paper, we review the current status of research in the fields of nanostructured thermoelectric materials with eco-friendly and low cost elements, such as skutterudites and oxides, for mid-high temperature applications, highlighting the strategies to improve thermoelectric performance.

A Study on Power Generation Efficiency through the Post Evaluation of Photovoltaic Panels in Complex Type Buildings - Focused on Annual Generation Performance of S-university - (단지형 건물군 내 태양광 패널의 사후 평가를 통한 발전 효율 연구 - S대학의 연간 발전 실적을 중심으로 -)

  • Kim, Heejin;Jung, Hyejin
    • Korean Journal of Construction Engineering and Management
    • /
    • v.18 no.5
    • /
    • pp.11-19
    • /
    • 2017
  • The purpose of this study is to analyze the efficiency of PV according to installation condition in the complex type buildings. For this purpose, annual performance of solar power generation in a certain area was investigated and various methods were conducted including post operation evaluation. In addition, we tried to find out influencing factors that affect the efficiency and sought to identify their relative impact of degree through the data analysis and site visits together. In the middle of this process we can draw up major considerations for the efficient photovoltaic power generation installation. In the mean while, previous studies are making something new related with method for efficiency enhancement and individual influential factors based on experimental environment rather than the empirical data site based. As a result of the study, it was confirmed that even if installed in the same area, the power generation efficiency is 1.5 times as high as the installation condition. Furthermore, statistical analyses were performed on azimuth, tilted angle and shade, which are variables affecting conversion efficiency, and it was statistically confirmed that all variables are meaningful factors that affect the conversion efficiency which is a dependent variable. The most influential factor is the azimuth, followed by the tilted angle and the shade factor. From this result, we expect to be able to provide installation guidelines for the solar power generation equipments on the rooftop zone.

A Study for Assessment Scope Set-up of Road Noise in EIA (환경영향평가시 도로소음 평가범위 설정에 대한 연구)

  • Choi, Joongyu;Sun, Hyosung;Choung, Taeryang
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.4
    • /
    • pp.567-572
    • /
    • 2012
  • This paper suggests the set-up plan of the assessment scope in road noise considering road characteristics with the prediction model of road noise. The RLS90 prediction model with some assumptions is used to establish the assessment scope of road noise. The main contents of the applied assumptions are smooth drive of cars, flat region, location of all noise sources in one lane, drive in design speed, and set-up of assessment scope according to traffic volume and car speed. The information of traffic volume to predict road noise is obtained by the distribution of small cars and full-sized cars in road. In this study, the total traffic volume in road is computed by adding the number of small cars to the conversion number of small cars, which means the number of small cars making the same noise as one full-sized car. The prediction result of road noise with the influence factor of traffic volume, car speed, distance between road and receiver is presented. The resultant assessment scope of road noise is obtained by combining road noise prediction data with the set-up standard of road noise assessment scope.

A Study to Improve the DC Output Waveforms of AFE Three-Phase PWM Rectifiers (AFE 방식 3상 PWM 정류기의 직류 출력파형 개선에 관한 연구)

  • Jeon, Hyeon-Min;Yoon, Kyoung-Kuk;Kim, Jong-Su
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.6
    • /
    • pp.739-745
    • /
    • 2017
  • Many studies have been conducted to reduce environmental pollution by ships and reduce fuel consumption. As part of this effort, research on power conversion systems through DC distribution systems that link renewable energy with conventional power grids has been pursued as well. The diode rectifiers currently used include many lower harmonics in the input current of the load and distort supply voltage to lower the power quality of the whole system. This distortion of voltage waveforms causes the malfunctions of generators, load devices and inverter pole switching elements, resulting in a large number of switching losses. In this paper, a controller is presented to improve DC output waveforms, the input Power Factor and the THD of an AFE type PWM rectifier used for PLL. DC output voltage waveforms have been improved, and the input Power Factor can now be matched to the unit power factor. In addition, the THD of the input power supply has been proven by simulation to comply with the requirements of IEEE Std514-2014.

Analysis on Temperature Dependence of Crystalline Silicon Solar Cells with Different Emitter Types for Desert Environment (사막형 결정질 실리콘 태양전지의 에미터 구조에 따른 온도 별 특성 변화 분석)

  • Nam, Yoon Chung;Kim, Soo Min;Kang, Yoonmook;Lee, Hae-Seok;Kim, Donghwan
    • Current Photovoltaic Research
    • /
    • v.2 no.3
    • /
    • pp.135-139
    • /
    • 2014
  • Different power output of solar cells can be observed at high-temperature regions such as desert areas. In this study, performance dependence on operating temperature of crystalline silicon solar cells with different emitter types was analyzed. Based on the light current-voltage (LIV) measurement, temperature coefficients of short-circuit current density ($J_{SC}$), open-circuit voltage ($V_{OC}$), fill factor (FF) and power conversion efficiency were measured and compared for two groups of crystalline silicon solar cells with different emitter types. One group had homogeneously doped (conventional) emitter and another selectively doped (selective) emitter. Varying the operating temperature from 25 to 40, 60, and $80^{\circ}C$, LIV characteristics of the cells were measured and the properties of saturation current densities ($J_0$) were extracted from dark current-voltage (DIV) curve. From the DIV data, effect of temperature on the performance of the solar cells with different electrical structures for the emitter was analyzed. Increasing the temperature, both emitter structures showed a slight increase in $J_{SC}$ and a rapid degradation of $V_{OC}$. FF and power conversion efficiency also decreased with the increasing temperature. The degrees of $J_{SC}$ increase and $V_{OC}$ degradation for two groups were compared and explained. Also, FF change was explained by series and shunt resistances from the LIV data. It was concluded that the degradation of solar cells shows different values at different temperatures depending on the emitter type of solar cells.

The Influences of Certification of Green Logistics Company on Performance (녹색물류기업 인증이 녹색물류성과에 미치는 영향)

  • Kim, Young-Min
    • Journal of Korea Port Economic Association
    • /
    • v.31 no.1
    • /
    • pp.111-125
    • /
    • 2015
  • This study aims at analyzing the influences of Certification of Green Logistics Company on performance and suggesting the implications. Based on previous studies which were related to certificate system of green logistics company and logistics performance, this study established research model and hypothesis, and surveyed the employees who worked in the field of logistics. To analyze the data, factor analysis, reliability analysis, confirmatory factor analysis and structural equation model were applied. The results are as follows. The object management of green logistics gives significantly positive effect to logistics performance and environment performance. The measurement of logistics energy and green gas give meaningful positive effect to logistics performance, environment performance and resource performance. The conversion of green logistics does not give significantly positive effect to any performances. And the effect management of green logistics has significant influence on firm performance.

Power Quality Improvement Using Hybrid Passive Filter Configuration for Wind Energy Systems

  • Kececioglu, O. Fatih;Acikgoz, Hakan;Yildiz, Ceyhun;Gani, Ahmet;Sekkeli, Mustafa
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.207-216
    • /
    • 2017
  • Wind energy conversion systems (WECS) which consist of wind turbines with permanent magnet synchronous generator (PMSG) and full-power converters have become widespread in the field of renewable power systems. Generally, conventional diode bridge rectifiers have used to obtain a constant DC bus voltage from output of PMSG based wind generator. In recent years, together advanced power electronics technology, Pulse Width Modulation (PWM) rectifiers have used in WECS. PWM rectifiers are used in many applications thanks to their characteristics such as high power factor and low harmonic distortion. In general, L, LC and LCL-type filter configurations are used in these rectifiers. These filter configurations are not exactly compensate current and voltage harmonics. This study proposes a hybrid passive filter configuration for PWM rectifiers instead of existing filters. The performance of hybrid passive filter was tested via MATLAB/Simulink environment under various operational conditions and was compared with LCL filter structure. In addition, neuro-fuzzy controller (NFC) was preferred to increase the performance of PWM rectifier in DC bus voltage control against disturbances because of its robust and nonlinear structure. The study demonstrates that the hybrid passive filter configuration proposed in this study successfully compensates current and voltage harmonics, and improves total harmonic distortion and true power factor.

A Novel Photovoltaic Power Harvesting System Using a Transformerless H6 Single-Phase Inverter with Improved Grid Current Quality

  • Radhika, A.;Shunmugalatha, A.
    • Journal of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.654-665
    • /
    • 2016
  • The pumping of electric power from photovoltaic (PV) farms is normally carried out using transformers, which require heavy mounting structures and are thus costly, less efficient, and bulky. Therefore, transformerless schemes are developed for the injection of power into the grid. Compared with the H4 inverter topology, the H6 topology is a better choice for pumping PV power into the grid because of the reduced common mode current. This paper presents how the perturb and observe (P&O) algorithm for maximum power point tracking (MPPT) can be implemented in the H6 inverter topology along with the improved sinusoidal current injected to the grid at unity power factor with the average current mode control technique. On the basis of the P&O MPPT algorithm, a power reference for the present insolation level is first calculated. Maintaining this power reference and referring to the AC sine wave of bus bars, a sinusoidal current at unity power factor is injected to the grid. The proportional integral (PI) controller and fuzzy logic controller (FLC) are designed and implemented. The FLC outperforms the PI controller in terms of conversion efficiency and injected power quality. A simulation in the MATLAB/SIMULINK environment is carried out. An experimental prototype is built to validate the proposed idea. The dynamic and steady-state performances of the FLC controller are found to be better than those of the PI controller. The results are presented in this paper.

Design of 3D Laser Radar Based on Laser Triangulation

  • Yang, Yang;Zhang, Yuchen;Wang, Yuehai;Liu, Danian
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.5
    • /
    • pp.2414-2433
    • /
    • 2019
  • The aim of this paper is to design a 3D laser radar prototype based on laser triangulation. The mathematical model of distance sensitivity is deduced; a pixel-distance conversion formula is discussed and used to complete 3D scanning. The center position extraction algorithm of the spot is proposed, and the error of the linear laser, camera distortion and installation are corrected by using the proposed weighted average algorithm. Finally, the three-dimensional analytic computational algorithm is given to transform the measured distance into point cloud data. The experimental results show that this 3D laser radar can accomplish the 3D object scanning and the environment 3D reconstruction task. In addition, the experiment result proves that the product of the camera focal length and the baseline length is the key factor to influence measurement accuracy.