• Title/Summary/Keyword: Environment Tests

Search Result 2,717, Processing Time 0.031 seconds

An Innovative Expert System for the Maintenance of On-site Wastewater Treatment Process for Small-scale Residential and Commercial Sites (마을단위 소규모 하·폐수처리 공정의 효율적 유지관리를 위한 전문가 시스템에 관한 연구)

  • Kim, Seung-jun;Choi, Yong-su;Hong, Seok-won;Kwon, Gi-han;Chung, Ik-jae
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.2
    • /
    • pp.132-140
    • /
    • 2005
  • The pilot test of a new alternative for small wastewater treatment system has been conducted for two years. It consists of a hybrid bioreactor and the expert system including the process control logic, PLC system, and HMI for the process automation. In order to monitor and remote control its status, the real-time data was transferred from the on-site control center to the central station via a wireless local area network. More efficient and stable performances were observed at automatic operating mode compared with the manual. On an average, COD, SS, T-N and T-P concentrations in the effluent from the hybrid bioreactor were less than 14, 7, 12 and 0.9 mg/L, respectively. According to the result from pilot tests, the quality of treated wastewater with sand filtration was enough to be utilized again.

Establishment of Low Temperature Environment System Using Polar Environment Performance Test Construction (극지환경성능시험설비를 활용한 저온환경 시스템 구축)

  • Sung, Ki-Young;Han, Seong-Jong;Lee, Jung-Hee
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.5
    • /
    • pp.843-851
    • /
    • 2022
  • This paper was conducted to study the conditions for the manufacture and operation of artificial snow removal and ice-making test facilities so that the test equipment can be tested in a low-temperature environment using the polar environment performance test facility. The polar environment performance test Facility is designed to artificially simulate extreme environments up to -65 ℃, and is a mid-to-large low-temperature environment test facility that can perform performance tests on offshore plant equipment, ships, leisure, and offshore structures. To verify the safety of deck work of ships operating in polar environments, artificial snow removal and artificial ice making devices were manufactured, and we conducted research on various operating environments using these facilities. For the efficient operation of artificial snow and ice making facilities, it is important to continuously supply dry air, and it has been found that installing an additional heater at the tip of the nozzle is effective in preventing freezing.

Application of Digital Signal Analysis Technique to Enhance the Quality of Tracer Gas Measurements in IAQ Model Tests

  • Lee, Hee-Kwan;Awbi, Hazim B.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.E2
    • /
    • pp.66-73
    • /
    • 2007
  • The introduction of tracer gas techniques to ventilation studies in indoor environments provides valuable information that used to be unattainable from conventional testing environments. Data acquisition systems (DASs) containing analogue-to-digital (A/D) converters are usually used to function the key role that records signals to storage in digital format. In the testing process, there exist a number of components in the measuring equipment which may produce system-based inference to the monitored results. These unwanted fluctuations may cause significant error in data analysis, especially when non-linear algorithms are involved. In this study, a pre-processor is developed and applied to separate the unwanted fluctuations (noise or interference) in raw measurements and to reduce the uncertainty in the measurement. Moving average, notch filter, FIR (Finite Impulse Response) filters, and IIR (Infinite Impulse Response) filters are designed and applied to collect the desired information from the raw measurements. Tracer gas concentrations are monitored during leakage and ventilation tests in the model test room. The signal analysis functions are introduced to carry out the digital signal processing (DSP) work. Overall the FIR filters process the $CO_2$ measurement properly for ventilation rate and mean age of air calculations. It is found that, the Kaiser filter was the most applicable digital filter for pre-processing the tracer gas measurements. Although the IIR filters help to reduce the random noise in the data, they cause considerable changes to the filtered data, which is not desirable.

Development of a Method for Detecting Unstable Behaviors in Flume Tests using a Univariate Statistical Approach

  • Kim, Seul-Bi;Seo, Yong-Seok;Kim, Hyeong-Sin;Chae, Byung-Gon;Choi, Jung-Hae;Kim, Ji-Soo
    • The Journal of Engineering Geology
    • /
    • v.24 no.2
    • /
    • pp.191-199
    • /
    • 2014
  • We describe a method for detecting slope instability in flume tests using pore pressure and water content data in conjunction with a statistical control chart analysis. Specifically, we conducted univariate statistical analysis on x-MR control chart data (pore pressure and water content) collected at several points along the flume slope, which we separated into three parts: upper, middle, and lower. To assess our results in the context of landslide forecasting and warning systems, we applied control limit lines at $1{\sigma}$, $2{\sigma}$, and $3{\sigma}$ levels of uncertainty. In doing so, we observed that dispersion time varies depending on the control limit line used. Moreover, the detection of instabilities is highly dependent on the position and type of sensor. Our findings indicate that different characteristics of the data on various factors predict slope failure differently and these characteristics can be identified by univariate statistical analysis. Therefore, we suggest that a univariate statistical approach is an effective method for the early detection of slope instability.

Determination of Aquifer Parameters by the Improved Slope-Matching Method (개선된 SM(Slope-Matching) 방법에 의한 대수층의 특성변수 결정)

  • 김민환;오종민;전일권
    • Journal of Soil and Groundwater Environment
    • /
    • v.6 no.4
    • /
    • pp.73-81
    • /
    • 2001
  • With the development of industry and standard of living, the quantity of groundwater consumption has been increasing. For the analysis of groundwater, to determine the hydraulic parameters of aquifer is very important. Various numerical methods have been developed to solve aquifer tests and eliminate the subjectivity of traditional graphical type curve methods. The slope-matching method, which matches the slope of the Theis type curve to the slope of the field data, can be used to numerically solve pump tests for both leaky and nonleaky aquifers. A FORTRAN program on based slope-matching method was developed to obtain the transmissivity, storage coefficient, and leaky factor from pumping test data automatically. Results derived from published data show that the improved slope-matching method gives parameters close to the ones derived by the slope-matching method.

  • PDF

Performance Evaluation of Powdered Activated Carbon (PAC) Contactor for the Removal of Organics and Taste and Odor (분말활성탄 접촉조의 맛·냄새 및 유기물 제거 효율 평가)

  • Bae, Byung-Uk;Lim, Mun-Gu
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.4
    • /
    • pp.585-589
    • /
    • 2010
  • In order to evaluate the performance of a powdered activated carbon (PAC) contactor, two water treatment plants (WTP) were selected as target sites. The result of tracer tests showed that the plug flow portion of a bisymmetry-type contactor (H WTP) was more than 70%. A maze-type contactor (C WTP) also had more than 70% of plug flow portion after intra-basin baffles were installed. According to the operating data of the target WTPs, there was no clear evidence that the addition of PAC contributed to the removal of organics. However, the results of jar tests, conducted with the raw water taken from the H WTP, proved that PAC could remove dissolved organic carbon (DOC) to some extent when the proper velocity gradient was maintained. It was estimated that the production rate, defined as the ratio of the operating flowrate to the design flowrate, of the C and H WTPs was only 27 and 50%, respectively. Because of these lower production rates, the mixing intensity in the contactor was much less than the designed value and, finally, the performance of the PAC contactor was much lower than what was expected.

Toxicity Monitoring of River Sediments in the Geum River Basin using Daphnia magna and Moina macrocopa (Daphnia magna와 Moina macrocopa를 이용한 금강수계 하천퇴적물 생태독성 모니터링)

  • Cho, Hyeyoon;Yoo, Jisu;Han, Youngseok;Han, Taejun;Kim, Sanghun;Jung, Jinho
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.6
    • /
    • pp.1000-1007
    • /
    • 2010
  • In this study, toxicity monitoring of sediments collected from 25 stations in the Geum river basin was conducted using Daphnia magna and Moina macrocopa. According to the results of acute toxicity tests (immobilization and mortality) of organic extracts of semdiments, Miho stream showed much less toxicity than Gap and Nonsan streams. In particular, significant toxicity was observed in both species for St.15 and St.16 sediment samples that passed through Deajeon city as a branch of Gap stream. For Nonsan stream, St.23 sediment showed high toxicity toward M. macrocopa. This site seemed to be affected by upper agricultural industrial complex. Additionally, M. macrocopa showed a higher sensitivity than D. magna for organic extracts of sediments. In the case of toxicity tests using sediment pore water and aqueous extracts, only pore water of St.27 sediment was toxic against D. magna. Toxicity identification evaluation showed that hydrogen sulfide was likely a major toxicant in the pore water.

Competitive Environment, Strategy, and Performance in the Supply Chain Network as Complex Adaptive System; Conceptualization for Adaptability and Mediating Role for Combinative Capability (복합적응시스템으로서 공급사슬네트워크의 환경, 전략, 그리고 성과에 관한 연구: 적응성의 개념화 및 조합적 경쟁역량의 매개적 역할을 중심으로)

  • Lee, Joung-Ho;Ryu, Choon-Ho
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2007.11a
    • /
    • pp.67-89
    • /
    • 2007
  • This study addresses manufacturers' ability to influence their supply chain network in order to adapt to their competitive environment. From the perspective of a manufacture, the supply chain comprises a network of suppliers and customers, and is theoretically viewed as a complex adaptive system. This study considers the following questions: (1) How can adaptability of supply chain network be operationally defined? (2) How does adaptability of supply chain network lead to combinative capabilities? (3) What is the influence of adaptability of supply chain network on business performance? Drawing on literature streams in supply chain management, operations strategy, organizational change and learning, and complexity theory, this study develops and tests the constructs and operational measures of adaptability of supply chain network and model the nomological set of relationships among constructs that form the basis of our theory. This study then develops and tests a model describing the outcomes of adaptability of supply chain network and its influence on combinative capability and business performance. Empirical results of this study show that adaptability supply chain network directly and positively affects combinative capability. Further, this study finds that adaptability of supply chain network does not impact business performance directly, but rather is mediated through combinative capability, which provides the requisite variety for firms to survive and thrive in dynamic environments.

  • PDF

A Pilot Study for Remediation of Groundwater by Surfactant -Enhanced Soil Flushing

  • Park, Jong Oh;Lee, Dal-Heui
    • Journal of Soil and Groundwater Environment
    • /
    • v.21 no.5
    • /
    • pp.1-7
    • /
    • 2016
  • The removal of non-aqueous phase liquids (NAPLs) from groundwater using pure water, via pump and treat, is quite ineffective due to their low solubility and hydrophobicity. Therefore, the objectives of pilot tests were to select potentially suitable surfactants that solubilize tetrachloroethylene (PCE) and trichloroethylene (TCE) present as contaminants and to evaluate the optimal range of process parameters that can increase the removal efficiency in surfactant-enhanced soil flushing (SESF). Used experimental method for surfactant selection was batch experiments. The surfactant solution parameters for SESF pilot tests were surfactant solution concentration, surfactant solution pH, and the flow rate of surfactant solution in the SESF pilot system. Based on the batch experiments for surfactant selection, DOSL (an anionic surfactant) was selected as a suitable surfactant that solubilizes PCE and TCE present as contaminants. The highest recovery (95%) of the contaminants was obtained using a DOSL surfactant in the batch experiments. The pilot test results revealed that the optimum conditions were achieved with a surfactant solution concentration of 4% (v/v), a surfactant solution pH of 7.5, and a flow rate of 30 L/min of surfactant solution (Lee and Woo, 2015). The maximum removal of contaminants (89%) was obtained when optimum conditions were simultaneously met in pilot-scale SESF operations. These results confirm the viability of SESF for treating PCE and TCE-contaminated groundwater.

Performance Tests of Oil Boom at Open Sea (오일붐의 실해역 성능평가 기법 개발)

  • Yu Jeongseok;Lee Moonjin;Kim Jinhwan
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.2 no.1
    • /
    • pp.49-62
    • /
    • 1999
  • The main functions of oil booms are to prevent spreading of the oil slick and to increase the recovering efficiency of oil skimmers. The oil-containment capability of a floating boom on an open sea is affected by environmental parameters such as waves, currents and winds, as well as the motion characteristics of a boom section. In this study, a series of tests were conducted for three kinds of booms (internal foam type, air inflatable type, self-expanded type) at the open sea off Yosu, and the results are presented. Motion characteristics and oversplashing phenomenon were observed for each boom in different environmental conditions. And the tension exerted on towing line of the boom was also measured with a systematic varitation of towing speeds and gap ratios.

  • PDF