• Title/Summary/Keyword: Environment Tests

Search Result 2,701, Processing Time 0.026 seconds

Performance evaluation on the separation device activated by shape memory alloy actuator (형상기억합금을 이용한 소형 위성용 분리장치의 성능평가)

  • Choi, Junwoo;Lee, Dongkyu;Hwang, Kukha;Lee, Minhyung;Kim, Byungkyu
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.7
    • /
    • pp.635-640
    • /
    • 2015
  • In this paper, we report a non-explosive separation device for a small satellite which utilize a shape memory alloy actuator. Based on previous research, we try to increase the reliability of the proposed device by changing some components. It enables the proposed device to activate under high preload. Also, we confirm it generates low shock which is main advantage of non-explosive separation device. Finally, vibration test which mimics launching environment and thermal vacuum test which mimics space environment are carried out respectively. After each environment test, we confirm the proposed device is successfully activated. Conclusively, we develop a non-explosive separation device which can activate with low shock under high preload after shock and environment tests(vibration and thermal vacuum tests).

The Role of Language Development in the Relation from Home Environment to Peer Competence of Young Children (유아의 가정환경과 또래유능성의 관계에서 언어발달의 역할)

  • Chang, Young Eun;Sung, Mi Young
    • Korean Journal of Childcare and Education
    • /
    • v.11 no.6
    • /
    • pp.1-18
    • /
    • 2015
  • The purpose of this study was to investigate the effects of the home environment of young children on their language and the quality of peer competence. The current study hypothesized that when the home environment of young children is desirable, the young children would be more likely to develop better language skills, which in turn, predict greater peer competence and lower levels of aggression and withdrawal in the interaction with peers at child care settings. The study used data of 1,802 families who have been participating in the Korean Child Panel Study since 2008. The results revealed that there was a significant relation from both positive home environment and better language skills to more positive play interaction and reduced play disruption and play disconnection. Home environment significantly predicted better expressive language development of young children and, in turn, higher scores on expressive vocabulary tests predicted greater peer competence and less negative play behaviors rated by child care providers. Statistical tests proved that the mediational effects of language skills between home environment and toddler's peer relationships were statistically significant. The study results emphasized the importance of language development in children's expanding social settings and the supporting role of rich and stimulus home environments in children's development.

High-Temperature Corrosion Behavior of Alloy 617 in Helium Environment of Very High Temperature Gas Reactor (초고온가스로 헬륨 분위기에서 Alloy 617의 고온 부식 거동)

  • Lee, Gyeong-Geun;Jung, Sujin;Kim, Daejong;Jeong, Yong-Whan;Kim, Dong-Jin
    • Korean Journal of Metals and Materials
    • /
    • v.50 no.9
    • /
    • pp.659-667
    • /
    • 2012
  • Alloy 617 is a Ni-base superalloy and a candidate material for the intermediate heat exchanger (IHX) of a very high temperature gas reactor (VHTR) which is one of the next generation nuclear reactors under development. The high operating temperature of VHTR enables various applications such as mass production of hydrogen with high energy efficiency. Alloy 617 has good creep resistance and phase stability at high temperatures in an air environment. However, it was reported that the mechanical properties decreased at a high temperature in an impure helium environment. In this study, high-temperature corrosion tests were carried out at $850^{\circ}C-950^{\circ}C$ in a helium environment containing the impurity gases $H_2$, CO, and $CH_4$, in order to examine the corrosion behavior of Alloy 617. Until 250 h, Alloy 617 specimens showed a parabolic oxidation behavior at all temperatures. The activation energy for oxidation in helium environment was 154 kJ/mol. The SEM and EDS results elucidated a Cr-rich surface oxide layer, Al-rich internal oxides and depletion of grain boundary carbides. The thickness and depths of degraded layers also showed a parabolic relationship with time. A normal grain growth was observed in the Cr-rich surface oxide layer. When corrosion tests were conducted in a pure helium environment, the oxidation was suppressed drastically. It was elucidated that minor impurity gases in the helium would have detrimental effects on the high-temperature corrosion behavior of Alloy 617 for the VHTR application.

DEVS/Unity3D Integrated System Design for the Autonomous UAV Agent Testing (자율형 UAV 에이전트 검증을 위한 DEVS/Unity3D 연동 시스템 설계)

  • Ha, Sun-ho;Kim, Jeong-ho;Kim, Hyun-geun;Shin, Suk-hoon;Chi, Sung-do
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.11
    • /
    • pp.1557-1565
    • /
    • 2016
  • The UAV systems working in difficult environment should be able to performs various actions autonomously required to achieve the given mission without the human interventions. However, the actual tests for such UAV system will take heavy cost. Thus, the simulation test in advance before the actual test is important. This paper proposes a 3D visual simulation environment for autonomous agent-based UAV systems. The several simulation tests performed on the rescue scenarios will demonstrate our techniques.

Overview of Thermal Test and Practice in Developing Satellite (인공위성 개발을 위한 유닛 열시험 개요와 실제)

  • Seo, Joung-Ki;Jang, Tae-Seong;Cha, Won-Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.11
    • /
    • pp.915-920
    • /
    • 2013
  • Units developed for a real satellite should pass space environmental tests and launch environment tests. Thermal Vacuum Test, one of the space environmental test, simulates extreme thermal environment encountered in on-orbit operation of satellite. Many payloads which adapt non-traditional, brand-new technology are developed by developers who is not familiar to space engineering field. There might be some possibility of mistakes which result in serious problem due to lack of experience, especially from planning to performing thermal vacuum test. In this paper, brief overview of thermal environmental test related to a satellite development is summarized in order to prepare and perform the thermal test.

A Comparative Study for Leaching Characteristics of Specified By-Products due to Changes in Acid Neutralization Capacities (지정부산물의 산중화능력변화에 따른 용출특성 비교연구)

  • 이현경;박주양
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.04a
    • /
    • pp.206-209
    • /
    • 2001
  • This study presents the leaching characterization of heavy metals according to changes of pH by ANC test on slag produced in electric arc furnace, bottom ash produced in coal-fired plants and their recycling products. Availability test was performed to assess the fraction of the total concentration that under worst environmental conditions could become available for leaching. TCLP, KLT(Korea Leaching Test) and KLTS(Korea Leaching Test of Soil contamination) were carried out to compare the leaching capacity and to estimate the adequacy of regulatory leaching test. Results from regulatory leaching tests could be misleading because the variable ANC of wastes can lead to very different final leachate pHs. The final pH of the regulatory test is not the ambient pH in the disposal environment, the actual solubilities of contaminants in the field may be entirely different from those predicted by these regulatory tests. Leaching behaviour of by-products was changed by recycling processes, therefore acid neutralization capacity and availability of new products, not leaching concentration by one batch regulatory test, are necessary to determine the method of recycling.

  • PDF

Mechanical properties of material in Q345GJ-C thick steel plates

  • Yang, Na;Su, Chao;Wang, Xiao-Feng;Bai, Fan
    • Steel and Composite Structures
    • /
    • v.21 no.3
    • /
    • pp.517-536
    • /
    • 2016
  • Thick steel plate is commonly found with mega steel structures but its properties have not been fully explored. Grade Q345GJ-C steel plate with thickness ranging from 60 mm to 120 mm are studied in this paper. Both the static and cyclic performance of material in different directions (horizontal and through-thickness directions) and locations (outer surface, 1/4 thickness and mid-depth) are experimentally obtained. The accumulative damage during cyclic loading is also calculated by using bilinear mixed hardening (BMH) constitutive relationship together with the Lemaitre's damage model. Results show that the static properties are better at the outer surface of thick steel plates than those at mid-depth. Properties in through-thickness direction are similar to those at mid-depth in the horizontal direction. The cyclic performance at different locations of a given plate is similar within the range of strain amplitude studied. However, when damage parameters identified from monotonic tensile tests are included in the numerical simulation of cyclic loading tests, damage is found accumulating faster at mid-depth than close to outer surface.

Experimental study on durability of strengthened corroded RC columns with FRP sheets in tidal zone of marine environment

  • Kashi, Amin;Ramezanianpour, Ali Akbar;Moodi, Faramarz
    • Computers and Concrete
    • /
    • v.19 no.4
    • /
    • pp.339-346
    • /
    • 2017
  • The main objective of this paper was to illuminate the effect of marine environmental condition on durability of reinforced concrete (RC)-corroded columns strengthened with carbon fiber reinforced polymer (CFRP) and glass fiber reinforced polymer (GFRP) layers. Small-scale columns were prepared and corroded by an accelerated corrosion process. After strengthening, compressive strength tests were carried out on control and weathered specimens. In this research, a marine simulator was designed and constructed similar to the tidal zone of marine environment in south of Iran which was selected as a case study in this research. Mechanical properties of wrapped specimens were studied after placing them inside the simulator for 3000 hours. Marine environment decreased ultimate strength by 4.5% and 26.3% in CFRP and GFRP-wrapped columns, respectively. In some corroded-columns, strengthening was carried out after replacing damaged cover by self-compacted mortar. In this method, by confining with one layer of CFRP and GFRP, 4.2% and 22.4% reduction in ultimate strength was observed, respectively, after exposure. Furthermore, the elastic-brittle behavior has been verified in this retrofit method. Also results of tension tests revealed, the ultimate tensile strength was degraded by 2% and 28.8% in CFRP and GFRP sheets, respectively, after applying marine exposure.

Evaluation of Diatom Growth Potential in Midstream and DownstreamNakdong River (낙동강 중. 하류에서의 규조류 성장잠재력 평가)

  • Kwon, Young-Ho;Seo, Jung-Kwan;Park, Sang-Won;Yang, Sang-Yong
    • ALGAE
    • /
    • v.21 no.2
    • /
    • pp.229-234
    • /
    • 2006
  • For the test organism of algal growth potential (AGP), the diatom in the genus Stephanodiscus which cause blooms in the Nakdong River was used instead of generally used strains of Selenastrum, Microcystis, or Anabaena. AGP results indicated that all the samples in the Nakdong River except for that from the Nakdan Bridge site were eutrophic state. Furthermore, the sample from Kumho River site was hypertrophic state. In the main stream Nakdong River, the value of AGP was lowest at the upstream Nakdan Bridge site and was highest at Koryoung Bridge site which is just downstream of Kumho River confluent point indicating the seriousness of pollution contributed by the Kumho River to the Nakdong River. Changes in the concentration of nutrients before and after the AGP tests and inter-relationship among the nutrients indicated that the growth of the Stephanodiscus in the AGP tests were mostly affected by the nitrate, silicate and phosphate. The limiting nutrient was identified by the nutrient addition experiments and the results showed that phosphate was the limiting nutrient for the growth of Stephanodiscus in the tested samples.

Mechanical behaviour of steel fibre reinforced SCC after being exposed to fire

  • Ponikiewski, Tomasz;Katzer, Jacek;Kilijanek, Adrian;Kuzminska, Elzbieta
    • Advances in concrete construction
    • /
    • v.6 no.6
    • /
    • pp.631-643
    • /
    • 2018
  • The focus of this paper is given to the investigation of mechanical properties of steel fibre reinforced self-compacting concrete after being exposed to fire. The research programme covered tests of two sets of beams: specimens subjected to fire and specimens not subjected to fire. The fire test was conducted in an environment mirroring one of possible real fire situations where concrete surface for an extended period of time is directly exposed to flames. Micro-cracking of concrete surface after tests was digitally catalogued. Compressive strength was tested on cube specimens. Flexural strength and equivalent flexural strength were tested according to RILEM specifications. Damages of specimens caused by spalling were assessed on a volumetric basis. A comparison of results of both sets of specimens was performed. Significant differences of all tested properties between two sets of specimens were noted and analysed. It was proved that the limit of proportionality method should not be used for testing fire damaged beams. Flexural characteristics of steel fibre reinforced self-compacting concrete were significantly influenced by fire. The influence of fire on properties of steel fibre reinforced self-compacting concrete was discussed.