• Title/Summary/Keyword: Environment Quality

Search Result 11,876, Processing Time 0.046 seconds

Study on Indoor Air Pollutants of Public Service Centers in Winter, Seoul (서울지역 공공청사 민원실의 겨울철 실내공기질에 관한 연구)

  • Jeon, Jea-Sik;Kim, Mi-Hyung;Lee, Ju-Yeol;Jeon, Myung-Jin;Ryu, In-Cheol;Park, Duck-Shin;Choi, Han-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.5
    • /
    • pp.569-579
    • /
    • 2011
  • This study evaluated the indoor air quality of 26 government offices located in Seoul. The pollutant samples were taken from Jan. 13th to Jan. 29th and Feb. 20th to Feb. 23rd, 2010 in the offices. The target indoor pollutants for this study were $PM_{10}$, formaldehyde, carbon monoxide, carbon dioxide, total bacteria counts, total volatile organic compounds, radon, nitrogen dioxide, ozone, and asbestos which were controlled by the indoor air quality law for the multiple-use facilities management. The results of this study showed that some pollutants of the 38.5% offices exceeded the standards of the air quality guideline. The correlation analysis of the same pollutants between indoor and outdoor represented that $NO_2$ (r=0.629, p<0.05) and $O_3$ (r=0.459, p<0.01) were significant, however, $PM_{10}$ and CO were not. The correlation analysis between different pollutants showed that CO and TVOC (total volatile organic compounds: r=0.724; p<0.01), CO and $NO_2$ (r=0.674; p<0.01), HCHO and humidity (r=0.605; p<0.01), $CO_2$ and TVOC (r=0.534; p<0.01), TBC (total bacteria counts) and Asbestos (r=0.520; p<0.01) were significant. The energy-saving system of government buildings in winter caused under-ventilated and poor air quality. This study suggests that the concentrations of radon and $CO_2$ should be used as an indicator for monitoring indoor air quality and maintaining effective ventilations.

Statistical Quality Control of Herbal Drugstuffs Distributed in Seoul Area - Centering around Ash, Acid-insoluble Ash, Loss on Drying and Hazardous Heavy Metals - (서울지역 유통한약재의 통계적 품질관리 - 회분, 산불용성회분, 건조감량, 유해중금속을 중심으로 -)

  • Kim, Dong-Gyu;Kim, Bog-Soon;Han, Chang-Ho;Kim, Eun-Ju;Choi, Byung-Hyun;Park, Seung-Kook
    • YAKHAK HOEJI
    • /
    • v.53 no.5
    • /
    • pp.274-280
    • /
    • 2009
  • To survey the status of quality control of major ingredients of 'Ssanghwatang (Oriental medicine used for fatigue)', we analyzed 1,024 samples (9 kinds) of medical herbs to determine amounts of ashes, acid-insoluble ashes, loss on drying that are major elements to ensure basic quality of herbal drugstuffs. After ash analysis, Paeoniae Radix (from China) failed to meet the herbal standard criterion. After yielding Z-score(indicating the probability of exceeding its criterion) Zizyphi Fructus, Zingiberis Rhizoma, Paeoniae Radix, Rehmanniae Radix Preparata became objects of intense quality control (=IQC). Analysis on loss on drying shows Cinnamomi Cortex was unsuitable and was put under the IQC. In case of respective heavy metals, Angelicae Gigantis Radix, Cnidii Rhizoma, Cinnamomi Cortex exceeded the maximum permissible range for Cd. The 3 kinds of sub-standards were put to the IQC. Statistic figures showed a significant correlation (t-test, p<0.01) between country-of-origin and sub-quality rates. Compared to domestic one, imported medicinal herbs were less suitable in regard of acid-insoluble ash, loss on drying and Pb/Hg content. Meanwhile, amounts of Acid-insoluble ash showed positive relation with amounts of Pb (r=0.202) and As (r=0.243) among heavy metals leading to an inference that herbs of which root/rhizome is used for medical purposes attribute its high heavy metal content to the fine earth/sand being stuck to its root stalk.

Development of Biological Criteria for Water Quality Assessment using Benthic Diatoms (부착돌말류를 이용한 생물학적 수질평가지표 개발)

  • Noh, Seongyou;Byeon, Myeongseop;Kim, Miah;Lee, Jaekwan
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.6
    • /
    • pp.879-885
    • /
    • 2009
  • The present study was carried out to develop biological criteria for water quality assessment using benthic diatoms. Selecting of the indicator diatoms, three parameters were considered: broad distribution (180 taxa occurred over 3% at upper level), species abundance (158 taxa occurred over $1.5{\times}10^5cells/cm^2$), and sensitivity (184 taxa occurred more than once as 1st and 2nd dominant species). Overall, total 208 taxa were selected, including 38 varieties, 170 species, 34 genera, 9 families, 3 orders, and 1 phylum. The most dominant taxonomic group (family) was Naviculaceae (52%), followed by Diatomaceae (15%), Nitzschiaceae (12%) and Achnantaceae (11%). COD and TP were proposed as new water quality standards (draft) to improve the existing BOD standard and to manage and control efficiently non-biodegradable organic pollutants. With this regard, we used TP standard (draft) in developing biological water quality criteria for diatoms. TP standards (draft) proposed as Ia = 0.02 mg/L or less, Ib = 0.05 mg/L or less, II = 0.1 mg/L or less, III = 0.2 mg/L or less, IV = 0.4 mg/L or less, V = 0.6 mg/L or less and VI = above 0.6 mg/L. Biological assessment system (4 class system) was developed and proposed for diatom using modified Tropic Diatom Index (TDI). Biological assessment of TDI appear B grade (Good).

The effects of Information System Operating Environment on the Productivity and Performance of Small and Medium Sized Manufacturing Enterprises

  • Lee, Heung-Bae;Kim, YoungJun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.26 no.7
    • /
    • pp.91-102
    • /
    • 2021
  • The effectiveness of informatization can vary depending on the level of operation of the information system as well as investment and installation. This study investigates and analyzes the information system operating environment and quality level of small and medium-sized manufacturing companies in Korea, and investigates how it affects the performance indicators of companies. The influence of the environmental factors operating the information system on the productivity performance and financial performance through the quality level of the information system was analyzed through the structural model. As a result of the analysis, it can be said that the higher the level of information system operating environment factors, the higher the quality level, the higher the quality level, the higher the productivity performance, and the higher the productivity performance, the higher the financial performance. It is judged that the effect of informatization depends on the operating environment and quality level after the installation of the information system.

Research about room air quality of department store underground parking lot (백화점 지하 주차장의 실내 공기질에 관한 연구)

  • Kim Ki-Tae;Yang Sung-Su;Son Bu-Soon;Jeon Young-Taek;Jang Bong-Ki;Lee Jong-Dae
    • Journal of environmental and Sanitary engineering
    • /
    • v.21 no.1 s.59
    • /
    • pp.44-51
    • /
    • 2006
  • This study was conducted to investigate air quality in the underground parking lot of department store. Sampling sites were selected to the three sites in one department store. Measuring instrument started from November 3rd, 2005 to November 9, 2005. Target air quality parameters include a number of criteria pollutants such as NOx, $O_3$. The purpose of this study was to find out the present condition of indoor air quality in underground parking space of department store. Through the field measurement, the current situation and the behavior of contaminants were investigated and then was compared with the advice standards. The result of this study was as follows; The Average density of NOx gas and $O_3$ gas was maintained below the indoor air advice standards. The Average density of NOx gas and $O_3$ gas was highly measured during the weekend than during the week day. Average density of NOx gas and $O_3$ gas was highly measured at daytime than that of afternoon. Average density of NOx gas was highly measured in the center area than the other area. Average density of $O_3$ gas was highly measured at the entrance than the other area. NOx gas concentration was maintained below 0.3ppm, an average for 1 hours, as defined in the parking space law. $O_3$ gas concentration was maintained below 0.08ppm, an average for 1 hours, as defined in the parking space law.

Analysis and Comparison about NPS of Plane Field and Alpine Field (평지밭과 고랭지밭의 비점오염에 대한 분석과 비교)

  • Choi, Yong-hun;Won, Chul-hee;Seo, Ji-yeon;Shin, Min-Hwan;Yang, Hee-jeong;Lim, Kyoung-jae;Choi, Joong-dae
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.5
    • /
    • pp.682-688
    • /
    • 2009
  • A plane field and a sloped field located at low-land plane and alpine areas, respectively, were monitored with respect to runoff, water quality and fertilizer uses from March to December, 2008. Runoff volume and Non-Point Source (NPS) loads were estimated and analyzed with respect to fertilizer uses. Total TN and TP loads from the sloped field were higher than those from plane field because of larger chemical uses in the alpine field than in the plane field. Organic matter load from plane field was higher than that from sloped field because more organic compost was applied to plane field than to sloped field. Event Mean Concentration (EMC) of measured water quality indices were relatively higher in both fields. Organic matter load per 1 mm rainfall were higher in plane field and TN and TP loads per 1 mm rainfall were higher in sloped field than those in respective comparing field. It was concluded that the type and application method of fertilizer could play an important role in the estimation of NPS pollution loads and the development of Best Management Practices (BMPs). However, it was recommended that long-term monitoring is necessary to better describe the relationship between fertilizer uses and water quality from agricultural fields because numerous natural and management factors other than fertilizer also affect runoff quality.

Development of a Stream Water Quality Model (QUAL-NIER) for the Management of Total Maximum Daily Loads (수질오염총량관리를 위한 하천수질모델(QUAL-NIER) 개발)

  • Park, Jun Dae;Shin, Dong Seok;Kim, Moon Sook;Kong, Dong Soo;Rhew, Doug Hee;Jung, Dong-Il;Na, Eun Hye
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.6
    • /
    • pp.784-792
    • /
    • 2008
  • Greater focus must be placed on ensuring that the water quality model (WQM) reflects the objective of its application and the characteristics of the water environment properly before it is selected. In the development or application of WQM, various factors influencing the model predictions should be reviewed so that it can perform more properly and reasonably based on scientific theory. This study reviewed the characteristic of existing WQM and the domestic river environment to find the requirements of the model application for TMDLs management in Korea. In this study, a water quality model, QUAL-NIER, was developed based on the USEPA's QUAL2E. The core structure and reaction scheme of the model was established followed by the formulation of equations according to the scheme with some supplements on the reaction mechanisms which are necessary for domestic rivers. Algorithms on the equations were set up and programmed to form a computer-based model. The developed model, QUAL-NIER was applied to the main stem of the Nakdong river. The model was calibrated and verified to data measured in 2004. The model results displayed good agrement with the field measurements for both calibration and verification. From this study, it was concluded that the developed QUAL-NIER model was very powerful with regard to the water quality simulation in domestic rivers.

A Study on Water Quality Management Methods of Waterscape Facilities in Accordance Legislation of Water Quality Criteria (수질기준 법제화에 따른 물놀이형 수경시설의 수질관리방안 연구)

  • Na, Kyung-Ho;Yong, Jeong-Ju;Kim, Ji-Soo;Byeon, Ju-Young
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.4
    • /
    • pp.487-493
    • /
    • 2017
  • This study was conducted to propose measures of water quality management as the water criteria for waterscape facilities which have been highlighted as alternatives to wading pools in summer season was legislated. The number of public waterscape facilities has reached 290 sites in Gyeounggi province and 971 sites in South Korea in 2017. The water tank capacity of 80.3 % public waterscape facilities was less than $100m^3$. Facilities with disinfection system were only 6.5 % and facilities with filtration function were also very low at 6.9 %. Most of the waterscape facilities, about 93%, are expected to be vulnerable to complying with revised water quality criteria because they have to be disinfected by handling. Chlorine disinfectants, which are more persistent than ozone or ultraviolet sterilization methods, are more preferred. However, care should be taken when adding disinfectans because hypochlorous acid, which is an effective component of chlorine disinfectant, remains after the disinfection, but it is easily decomposed with time. For this study, ${\bigcirc}{\bigcirc}$ park floor fountain with a capacity of $63m^3$ was selected and the amount of free residual chlorine concentration was measured by injecting a certain amount of chlorine bleach. As a result, it took 5 hours to decrease from the water quality standard of 4 mg/L to 0.04 mg/L. If the waterscape facility is operated for 7 to 8 hours, the chlorine bleach should be re-injected after 5 hours. In addition, the problem of pH increase due to the input of chlorine disinfectant is expected, and the neutralization method using vinegar was proposed.

Preliminary Studies for Efficient Treatment of Wastewater Milking Parlor in Livestock Farm (젖소 착유세정폐수의 효율적인 정화처리를 위한 기초연구)

  • Jang, Young Ho;Lee, Soo Moon;Kim, Woong Su;Kang, Jin Young
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.6
    • /
    • pp.500-507
    • /
    • 2020
  • This study examined the wastewater at a livestock farm, and found that the dairy wastewater from the milking parlor had a lower concentration than the piggery wastewater, and that it was produced at a rate under 1.3 ㎥/day in a single farmhouse. The amount of dairy wastewater was determined based on the performance of the milking machine, the maintenance method of the milking parlor, and the amount of milk production allocated for each farmhouse, not by the area. The results confirmed that both dairy wastewater treatment processes, specifically those using Hanged Bio-Compactor (HBC) and Sequencing Batch Reactor (SBR), can fully satisfy the water quality standards of discharge. The dairy wastewater has a lower amount and concentration than piggery wastewater, meaning it is less valuable as liquid fertilizer, but it can be easily degraded using the conventional activated sludge process in a public sewage treatment plant. Therefore, discharging the dairy wastewater after individual treatment was expected to be a more reasonable method than consigning it to the centralized wastewater treatment plant. The effluent after the SBR process showed a lower degree of color than the HBC effluent, which was attributed to biological adsorption. In the case of the milking parlor in the livestock farm, the concentrations of the effluents obtained after HBC and SBR treatments both satisfied water quality standards for the discharge of public livestock wastewater treatment plants at 99% confidence intervals, and the concentrations of total nitrogen and phosphorous in untreated wastewater were even lower than the water quality standards of discharge. Therefore, we need to discuss strengthening the water quality standards to reduce environmental pollution.

Elasticity Analyses between Water Temperature and Water Quality considering Climate Change in Nak-dong River Basin (기후변화를 고려한 낙동강 유역의 수온과 수질 탄성도 분석)

  • Shon, Tae Seok;Lee, Kyu Yeol;Im, Tae Hyo;Shin, Hyun Suk
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.6
    • /
    • pp.830-840
    • /
    • 2011
  • Climate change has been settled as pending issues to consider water resources and environment all over the world, however, scientific and quantitative assessment methods of climate change have never been standardized. When South Korea headed toward water deficiency nation, the study is not only required analysis of atmospheric or hydrologic factors, but also demanded analysis of correlation with water quality environment factors to gain management policies about climate change. Therefore, this study explored appropriate monthly rainfall elasticity in chosen 41 unit watersheds in Nak-dong river which is the biggest river in Korea and applied monitored discharge data in 2004 to 2009 with monthly rainfall using Thiessen method. Each unit watershed drew elasticity between water temperature and water quality factors such as BOD, COD, SS, T-N, and T-P. Moreover, this study performed non-linear correlation analysis with monitored discharge data. Based on results of analysis, this is first steps of climate change analysis using long-term monitoring to develop basic data by Nak-dong river Environmental Research Center (Ministry of Environment) and to draw quantitative results for reliable forecasting. Secondary, the results considered characteristic of air temperature and rainfall in each unit watershed so that the study has significance its various statistical applications. Finally, this study stands for developing comparable data through "The 4 major river restoration" project by Korea government before and after which cause water quality and water environment changes.