• Title/Summary/Keyword: Entry Length

Search Result 92, Processing Time 0.025 seconds

Flow of a low concentration polyacrylamide fluid solution in a channel with a flat plate obstruction at the entry

  • Kabir, M.A.;Khan, M.M.K.;Rasul, M.G.
    • Korea-Australia Rheology Journal
    • /
    • v.16 no.2
    • /
    • pp.63-73
    • /
    • 2004
  • Flow in a channel with an obstruction at the entry can be reverse, stagnant or forward depending on the position of the obstruction. These flow phenomena have potential applications in the control of energy and various flows in process engineering. Parameters that affect this flow inside and around the test channel are the gap (g) between the obstruction geometry and the test channel, the Reynolds number (Re) and the length (L) of the test channel. The influence of these parameters on the flow behavior was investigated using a flat plate obstruction at the entry of the channel. A low concentration polyacrylamide solution (0.018% by weight) showing a powerlaw fluid behavior was used as the fluid in this investigation. The flow phenomena were investigated by the velocity measurement and the flow visualization and their results were compared with numerical simulation. These results of low concentration polyacrylamide solution are also compared with the results of water published elsewhere (Kabir et al., 2003). The maximum reverse flow inside the test channel observed was 20% - 30% of the outside test channel velocity at a g/w (gap to width) ratio of 1 for Reynolds numbers of 1000 to 3500. The influence of the test channel length (L) and the Reynolds number (Re) on the velocity ratio ($V_i$/$V_o$: inside velocity/outside velocity in the test channel) are also presented and discussed here.

Statistical Information of Korean Dictionary to Construct an Enormous Electronic Dictionary (대용량 전자사전 구축을 위한 국어 대사전의 통계 정보)

  • Kim, Cheol-Su;Kim, Yang-Beom
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.6
    • /
    • pp.60-68
    • /
    • 2007
  • There are various application areas of Language information processing such as information retrieval, morphological analysis, spell checker, voice recognition, character recognition, etc. In these language information processing areas, an electronic dictionary is essential. This thesis made researches on basic statistical information on the Korean dictionary and on the construction of electronic dictionary. The targets of analysis were the number of registered word in Korea dictionary, the entry number of registered word in electronic dictionary, the number of used syllables, the number of different syllables, the average length of entry, the distribution of part of speech and the number of used nodes to construct electronic dictionary using Trie, except for words including a archaic word or incomplete syllables. Total entry number of electronic dictionary is 361,980, the number of used syllables is 1,289,659, the average length of entries is 3.56 and the number of different syllables is 2,463. Theses informations would play a beneficial role in constructing an electronic dictionary and in processing Korean information.

Feasibility of Bilateral Crossing C7 Intralaminar Screws : A Cadaveric Study

  • Baek, Tae-Hyun;Kim, Ilsup;Hong, Jae-Taek;Kim, Daniel H.;Shin, Dongsuk;Lee, Sang-Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.56 no.1
    • /
    • pp.5-10
    • /
    • 2014
  • Objective : When the pedicle screw insertion technique is failed or not applicable, C7 intralaminar screw insertion method has been used as an alternative or salvage fixation method recently. However, profound understanding of anatomy is required for safe application of the bilaterally crossing laminar screw at C7 in clinic. In this cadaveric study, we evaluated the anatomic feasibility of the bilateral crossing intralaminar screw insertion and especially focused on determination of proper screw entry point. Methods : The C7 vertebrae from 18 adult specimens were studied. Morphometric measurements of the mid-laminar height, the minimum laminar thickness, the maximal screw length, and spino-laminar angle were performed and cross-sectioned vertically at the screw entry point (spino-laminar junction). The sectioned surface was equally divided into 3 parts and maximal thickness and surface area of the parts were measured. All measurements were obtained bilaterally. Results : The mean mid-laminar height was 13.7 mm, mean minimal laminar thickness was 6.6 mm, mean maximal screw length was 24.6 mm, and mean spinolaminar angle was $50.8{\pm}4.7^{\circ}$. Based on the measured laminar thickness, the feasibility of 3.5 mm diameter intralaminar screw application was 83.3% (30 sides laminae out of total 36) when assuming a tolerance of 1 mm on each side. Cross-sectional measurement results showed that the mean maximal thickness of upper, middle, and lower thirds was 5.0 mm, 7.5 mm, and 7.3 mm, respectively, and mean surface area for each part was $21.2mm^2$, $46.8mm^2$, and $34.7mm^2$, respectively. Fourteen (38.9%) sides of laminae would be feasible for 3.5 mm intralaminar screw insertion when upper thirds of C7 spino-laminar junction is the screw entry point. In case of middle and lower thirds of C7 spino-laminar junction, 32 (88.9%) and 28 (77.8%) sides of laminae were feasible for 3.5 mm screw insertion, respectively. Conclusion : The vertical cross-sectioned area of middle thirds at C7 spinolaminar junction was the largest area and 3.5 mm screw can be accommodated with 77.8 % of feasibility when lower thirds were the screw entry point. Thus, selection of middle and lower thirds for each side of screw entry point in spino-laminar junction would be the safest way to place bilateral crossing laminar screw within the entire lamina. This anatomic study result will help surgeons to place the screw safely and accurately.

A Non-Cirucular Contact Arc Model for Temper Rolling

  • Y.L. Liu;Lee, W.H.;Cho, K.J.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1999.08a
    • /
    • pp.293-300
    • /
    • 1999
  • A mathematical model for the analysis of roll gap phenomena in strip temper rolling process is described. The mechanical peculiarities of temper rolling process, such as high friction value and non-circular contact arc, low reduction and non-negligible entry and exit elastic zones as well as central restricted deformation (preliminary displacement or sticking) zone etc., are all taken into account. The deformation of work rolls is calculated with the influence function method and arbitrary contact arc shape is permitted. The strip deformation is modeled by slab method and the entry and exit elastic deformation zones are included. The restricted deformation zone near the neutral point is also considered. The concept and the calculation method of limiting preliminary displacement are used to determine the length of the central restricted deformation zone. The comparison of the model results with the measured mill data is also made.

  • PDF

Prediction of Childhood Asthma Using Expectation Maximization and Minimum Description Length Algorithm

  • Kim, Hyo Seon;Park, Jong Suk;Nam, Dong Kyu;Jung, Yong Gyu
    • International Journal of Advanced Culture Technology
    • /
    • v.8 no.3
    • /
    • pp.275-279
    • /
    • 2020
  • Due to the recent rapid industrialization worldwide, the number of pediatric asthma patients is increasing. And the fine dust containing heavy metals is linked to the characteristics of high toxic lead due to the increase heating in factory operation and automobile driving. It is the reason of arsenic increasing. In the treatment of pediatric asthma patients, drug administration, oral drug entry, and HMPC (Home Management Plan of Care) are used. In this paper, we analyze the relationship between the onset of asthma and the method of prescription for specific childhood asthma in the United States using EM (Expectation Maximization) and MDL (Minimum Description Length) algorithms. And the association is also analyzed by comparing the nature of specific congestion between the past prevalence of digestive asthma and the recent prevalence of environmental pollution.

Anatomic Analysis of Rectus Femoris Functional Flap in Korean (대퇴직근 기능성 유리 피판술을 위한 신경 및 혈관에 대한 해부학적 고찰)

  • Han, Kyoung-Jin;Lee, Young-Kil;Kim, Joon-Yong;Han, Seung-Hwan;Lee, Du-Hyoung;Cho, Jae-Ho
    • Archives of Reconstructive Microsurgery
    • /
    • v.16 no.1
    • /
    • pp.1-5
    • /
    • 2007
  • The purpose of this article to evaluate the availability of the rectus femoris flap in Korean subjects. Material and Methods is that Cadaveric dissections were done on 51 femoral triangles of 26 cadevers. We measured the length of the direct head of rectus femoris from anterior superior iliac spine to patella upper pole, ASIS to lateral border of femoral nerve, and entry point of femoral nerve and vessel branches to rectus. Usually, there were three terminal branches to rectus femoris from the femoral nerve. The entry point of the first branch was at the proximal $17.5{\sim}31.4%$ portion of the rectus femoris. The second and the third branch entered at the proximal $22.5{\sim}40.7%$ and $26.3{\sim}42.3%$, respectively. The vessel entry was at $20.2{\sim}37.3%$. The length from ASIS to femoral nerve was $3.5{\sim}8.5\;cm$. Among the 51 rectus femoris muscles, 44 had one nutrient artery, and 7 had 2 nutrient arteries. The nutrient artery originated from the descending branch of the lateral femoral circumflex artery in 18(40.9%) cases, directly from the lateral femoral circumflex artery in 8(18.0%) cases, and from proximal(6 cases, 13.6%) and distal(12 cases, 27.3%) portion of the deep femoral artery. The average length of the nutrient artery was 29.8 mm and the width was 2.14 mm. The point where it meets the main feeding artery of the rectus femoris was $9.0{\sim}15.0\;cm$ from the ASIS. In all cases, the main artery's entrance was proximal to the first nerve branch. Conclusion is that rectus femoris has available data for functional flap.

  • PDF

MULTI-OBJECTIVES FUZZY MODELS FOR DESIGNING 3D TRAJECTORY IN HORIZONTAL WELLS

  • Qian, Weiyi;Feng, Enmin
    • Journal of applied mathematics & informatics
    • /
    • v.15 no.1_2
    • /
    • pp.265-275
    • /
    • 2004
  • In this paper, multi-objective models for designing 3D trajectory of horizontal wells are developed in a fuzzy environment. Here, the objectives of minimizing the length of the trajectory and the error of entry target point are fuzzy in nature. Some parameters, such as initial value, end value, lower bound and upper bound of the curvature radius, tool-face angle and the arc length of each curve section, are also assumed to be vague and imprecise. The impreciseness in the above objectives have been expressed by fuzzy linear membership functions and that in the above parameters by triangular fuzzy numbers. Models have been solved by the fuzzy non-linear programming method based on Zimmermann [1] and Lee and Li [2]. Models are applied to practical design of the horizontal wells. Numerical results illustrate the accuracy and efficiency of the fuzzy models.

An Aerosol CVD Method Using Internal Jet for Optical Fiber Synthesis (내부제트 분사를 이용한 새로운 광섬유제조 화학증착 방법에 관한 연구)

  • Hong, Choon-Keun;Choi, Man-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.4
    • /
    • pp.608-613
    • /
    • 2000
  • The present study has proposed a novel aerosol CVD utilizing an internal jet in the conventional MCVD reactor for the purpose of enhancing the deposition efficiency(and rate) and the uniformity of deposited film. The use of impingement of high temperature jet through a thin inner tube ensures the reduction of non-uniform particle deposition zone as well as higher thermophoretic particle deposition. It is shown that significant improvements have been achieved for both aspects of deposition efficiency and uniformity. As jet temperatures increase, the tapered length is reduced and deposition efficiency is significantly increased.

DYNAMIC SET-UP CONTROL OF TANDEM COLD MILL (연속압연기에서 OFF GAUGE 저감을 위한 DYNAMIC SET-UP 제어기술)

  • 노호섭;최병조;조뇌하;이재훈;김익준;진철제;박기영
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1999.08a
    • /
    • pp.126-131
    • /
    • 1999
  • In order to reduce the length of off-gauge at FGC(Flying gauge change) point, We adopted dynamic set up in No. 4 cold rolling mill. The conventional set-up of FGC(Flying gauge change) was calculated on the basis of preset values in the process control computer, so the difference between actual strip thickness and preset thickness cause long off-gauge. The dynamic SET-UP control was calculated on the basis of actual strip thickness of FGC(Flying gauge change) point from X-ray gauge of mill entry and No.i stand. We applied dynamic SET-UP control in September last year. Compare to the previous result, the length of off-gauge is reduced by about 36%.

  • PDF

A Study of the Flow Phenomenon of Water in a Channel with Flat Plate Obstruction Geometry at the Entry

  • Khan, M.M.K.;Kabir, M.A.;Bhuiyan, M.A.
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.879-887
    • /
    • 2003
  • The flow in a parallel walled test channel, when obstructed with a geometry at the entrance, can be forward, reverse and stagnant depending on the position of the obstruction. This interesting flow phenomenon has potential benefit in the control of energy and various flows in the process industry In this experiment, the flat plate obstruction geometry was used as an obstruction at the entry of the test channel. The parameters that influence the flow inside and around the test channel were the gap (g) between the test channel and the obstruction geometry, the length (L) of the test channel and the Reynolds number (Re). The effect of the gap to channel width ratio (g/w) on the magnitude of the velocity ratio (V$\_$i/ / V$\_$o/ : velocity inside/ velocity outside the test channel) was investigated for a range of Reynolds numbers. The maximum reverse flow observed was nearly 20% to 60% of the outside velocity for Reynolds number ranging from 1000 to 9000 at g/w ratio of 1.5. The maximum forward velocity inside the test channel was found 80% of the outside velocity at higher g/w ratio of 8. The effect of the test channel length on the velocity ratio was investigated for different g/w ratios and a fixed Reynolds number of 4000. The influence of the Reynolds number on the velocity ratio is also discussed and presented for different gap to width ratio (g/w). The flow visualisation photographs showing fluid motion inside and around the test channel are also presented and discussed.