• 제목/요약/키워드: Enrgy saving

검색결과 3건 처리시간 0.019초

Economizer cycle control을 채용한 전열교환시스템의 에너지 절감효과 분석 -국내 공동주택을 대상으로- (Energy Saving Effect of ERV(Energy Recovery ventilator) with Economizer Control in Residential Building)

  • 박재형;김주욱;송두삼;윤호영;김성우
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.679-684
    • /
    • 2009
  • ERV system has installed in almost newly constructed residential building in Korea. Heat recovery features of ERV can be possible to decrease the heating and cooling load caused by ventilation. However, in case of the outdoor condition is favorable to control the indoor air, the heat recovery function of ERV does more harm than good in term of cooling load. In this study, the ERV with economizer cycle control for residential building is suggested and the performance of the suggested system will be analyzed using TRNSYS.

  • PDF

LNG냉열이용 수소액화 공정해석 및 설계 (Design and Analysis for Hydrogen Liquefaction Process Using LNG Cold Energy)

  • 윤상국
    • 한국가스학회지
    • /
    • 제15권3호
    • /
    • pp.1-5
    • /
    • 2011
  • 수소액화 공정은 수소 예냉 에너지, 액화에너지 그리고 Ortho/Para 변환열 제거 등 다량의 에너지가 요구되어 진다. 본 논문은 기존의 수소액화 공정에 LNG냉열을 이용하여 에너지절약 효과를 얻고자 기본설계 및 열해석을 수행하였다. 액화 소요에너지에 LNG냉열을 적용하면 수소액화공정의 에너지절약효과와 함께, LNG기지의 해수에 버려지는 LNG냉열을 회수, 이용하는 일석이조의 에너지절약기술이 된다. 열해석에 의한 설계를 수행한 결과 현재의 액체질소 예냉식 수소액화 플랜트의 소요에너지에 비하여 LNG냉열을 이용할 경우 소요동력량은 75%가 절감되었다. 이는 예냉을 액체질소 대신에 냉열을 사용하기 때문이다. 또한 LNG냉열량은 수소액화량 1T/D기준할 때 15T/D 유량이 요구되었다.

한국형 패시브하우스를 위한 단열블럭시스템의 난방에너지소비 특성 (A Characteristic Heating-Energy Expend of Insulation Block System for Korea Type Passive House)

  • 강재식;최경석;양관섭;이승언
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.603-607
    • /
    • 2009
  • About a Structure is performance external insulation is fundamantal performance for enrgy-saving. these day, most of residential structures have constructed by internal insulation method structure. The method structure internal insulation have construction and economical efficiency, but on the other hand, be generated heat loss by heat bridge especially, be generated loss heat-energy logical consequence in structure ondol. The external insulation structure method has a mert able to minimum to loss heat about heat-bridge. But the external insulation technique is unsatisfactory statues within the know-how and method of construction and materials compared with developed countries. The recently, the requirement of market related to the external insulation technique is resulted by the energy efficiency system, but it can lead to the lack of alternative technique In study on the korea type passive house building design for insulation block method of wall system has to experimental characteristic heat-energy of practice building. In result field-experimental, the heat-bridge appeared to characteristic spent heat-energy of blow 2L class and have a suffience performance it.

  • PDF