• Title/Summary/Keyword: Enhancement-mode

Search Result 324, Processing Time 0.031 seconds

Raman Characteristics of (100) β-Gallium Oxide Single Crystal Grown by EFG Method (EFG법을 이용한 (100) β-산화갈륨 단결정 성장 및 라만 특성 연구)

  • Shin, Yun-Ji;Cho, Seong-Ho;Jeong, Woon-Hyeon;Jeong, Seong-Min;Lee, Won-Jae;Bae, Si-Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.6
    • /
    • pp.626-630
    • /
    • 2022
  • A 100 mm × 50 mm-sized (100) gallium oxide (Ga2O3) single crystal ingot was successfully grown by edge-defined film-fed growth (EFG). The preferred orientation and the quality of grown Ga2O3 ingot were compatible with a commercial Ga2O3 substrate by showing strong (100) orientation behaviors and 246 arcsec in X-ray rocking curve. Raman characterization was also performed for both samples; thereby providing various Raman-active characteristics of Ga2O3 crystals. In particular, we observed Ag(5) and Ag(10) peaks of Raman active mode, directly related to the impurity of the grown Ga2O3 crystal. Hence, the comparison of the crystal quality and Raman analysis might be useful for further enhancement of Ga2O3 single crystal quality in the future.

Vertical root fracture diagnosis in teeth with metallic posts: Impact of metal artifact reduction and sharpening filters

  • Debora Costa Ruiz;Lucas P. Lopes Rosado;Rocharles Cavalcante Fontenele;Amanda Farias-Gomes;Deborah Queiroz Freitas
    • Imaging Science in Dentistry
    • /
    • v.54 no.2
    • /
    • pp.139-145
    • /
    • 2024
  • Purpose: This study examined the influence of a metal artifact reduction (MAR) tool, sharpening filters, and their combination on the diagnosis of vertical root fracture (VRF) in teeth with metallic posts using cone-beam computed tomography (CBCT). Materials and Methods: Twenty single-rooted human premolars - 9 with VRF and 11 without - were individually placed in a human mandible. A metallic post composed of a cobalt-chromium alloy was inserted into the root canal of each tooth. CBCT scans were then acquired under the following parameters: 8 mA, a 5×5 cm field of view, a voxel size of 0.085 mm, 90 kVp, and with MAR either enabled or disabled. Five oral and maxillofacial radiologists independently evaluated the CBCT exams under each MAR mode and across 3 sharpening filter conditions: no filter, Sharpen 1×, and Sharpen 2×. The diagnostic performance was quantified by the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity. These metrics were compared using 2-way analysis of variance with a significance level of α=5%. Intra- and inter-examiner agreement were assessed using the weighted kappa test. Results: Neither MAR nor the application of sharpening filters significantly impacted AUC or specificity (P>0.05). However, sensitivity increased when MAR was combined with Sharpen 1× and Sharpen 2× (P=0.015). The intra-examiner agreement ranged from fair to substantial (0.34-0.66), while the inter-examiner agreement ranged from fair to moderate (0.27-0.41). Conclusion: MAR in conjunction with sharpening filters improved VRF detection; therefore, their combined use is recommended in cases of suspected VRF.

Evaluation of Usefulness of Portal Image Using Electronic Portal Imaging Device (EPID) in the Patients Who Received Pelvic Radiation Therapy (골반강 내 방사선 치료 환자에서 Electronic Portal Imaging Device(EPID)를 이용한 Portal Image의 유용성에 관한 연구)

  • Kim Woo Chul;Park Won;Kim Heon Jong;Park Seong Young;Cho Young Kap;Loh John J;Suh Chang Ok;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.497-504
    • /
    • 1998
  • Purpose : To evaluate the usefulness of electronic portal imaging device through objective compare of the images acquired using an EPID and a conventional port film Materials and Methods : From Apr. to Oct. 1997, a total of 150 sets of images from 20 patients who received radiation therapy in the pelvis area were evaluated in the Inha University Hospital and Severance Hospital. A dual image recording technique was devised to obtain both electronic portal images and port film images simultaneously with one treatment course. We did not perform double exposure five to ten images were acquired from each patient. All images were acquired from posteroanterior (PA) view except images from two patients. A dose rate of 100-300 Mu/min and a 10-MV X-ray beam were used and 2-10 MUs were required to produce a verification image during treatment. Kodak diagnostic film with metal/film imaging cassette which was located on the top of the EPID detector was used for the port film. The source to detector distance was 140 cm. Eight anatomical landmarks (pelvic brim, sacrum, acetabulum. iliopectineal line, symphysis, ischium, obturator foramen, sacroiliac joint) were assessed. Four radiation oncologist joined to evaluate each image. The individual landmarks in the port film or in the EPID were rated - very clear (1), clear (2), visible (3), not clear (4), not visible (5). Results : Using an video camera based EPID system. there was no difference of image quality between no enhanced EPID images and port film images. However, when we provided some change with window level for the portal image, the visibility of the sacrum and obturator foramen was improved in the portal images than in the port film images. All anatomical landmarks were more visible in the portal images than in the port film when we applied the CLAHE mode enhancement. The images acquired using an matrix ion chamber type EPID were also improved image qualify after window level adjustment. Conclusion : The quality of image acquired using an electronic portal imaging device was comparable to that of the port film. When we used the enhance mode or window level adjustment. the image quality of the EPID was superior to that of the port film. EPID may replace the port film.

  • PDF

A Solution for Congestion and Performance Enhancement using Dynamic Packet Bursting in Mobile Ad Hoc Networks (모바일 애드 혹 네트워크에서 패킷 버스팅을 이용한 혼잡 해결 및 성능향상 기법)

  • Kim, Young-Duk;Yang, Yeon-Mo;Lee, Dong-Ha
    • Journal of KIISE:Information Networking
    • /
    • v.35 no.5
    • /
    • pp.409-414
    • /
    • 2008
  • In mobile ad hoc networks, most of on demand routing protocols such as DSR and AODV do not deal with traffic load during the route discovery procedure. To solve the congestion and achieve load balancing, many protocols have been proposed. However, the existing load balancing schemes has only considered avoiding the congested route in the route discovery procedure or finding an alternative route path during a communication session. To mitigate this problem, we have proposed a new scheme which considers the packet bursting mechanism in congested nodes. The proposed packet bursting scheme, which is originally introduced in IEEE 802.11e QoS specification, is to transmit multiple packets right after channel acquisition. Thus, congested nodes can forward buffered packets promptly and minimize bottleneck situation. Each node begins to transmit packets in normal mode whenever its congested status is dissolved. We also propose two threshold values to define exact overloaded status adaptively; one is interface queue length and the other is buffer occupancy time. Through an experimental simulation study, we have compared and contrasted our protocol with normal on demand routing protocols and showed that the proposed scheme is more efficient and effective especially when network traffic is heavily loaded.

Research on the prevention of legal dispute over 119 rescue team (119구급대의 법적분쟁 예방에 관한 연구)

  • Lim, Jae-Man
    • The Korean Journal of Emergency Medical Services
    • /
    • v.13 no.1
    • /
    • pp.19-33
    • /
    • 2009
  • Purpose : To check the legal relation between rescue team and patient as well as legal responsibility for patient's damage intentionally or erroneously caused by rescue member, a public official, in the performance of relevant job ; to prevent legal dispute over rescue team and to present program for fair settlement of dispute and equitable and feasible burden of damage. Method : First, the legal principle of Civil Law, Criminal Law and Administrative Law related to the theme of this research will be investigated around research by literature. Second, the case of dispute related to rescue team will be introduced. Result: 1. If 119 rescue members as a public official intentionally or erroneously cause damage to patient in the performance of job, they shall bear civil, criminal and administrative responsibility. They shall bear civil responsibility for indemnity for damage due to default or tort. The typical criminal responsibility includes accidental homicide arising out of duty, preparing falsified official document, dereliction of duty, etc. In the administrative side, the state is responsible for indemnity for peculiar status of the rescue member, public official. 2. Though raising civil petition or legal dispute over unsatisfactory rescue service may be reasonable to guarantee the right of nation, such action may cause stress to rescue member as well as may lead to mental shrinking and defensive attitude only to take the basic first aid treatment which has low possibility of mistake instead of active first aid treatment so as to avoid legal responsibility. 3. The program that may prevent legal dispute over 119 rescue team includes expansion of manpower specialized in first aid treatment, enhancement of education on legal environment, development and application of standard job guideline, formation of mutual trust with patient, detailed explanation, preparing and keeping minute record, improvement of the rescue members' ability of first aid treatment and development of medical instruction mode. Conclusion : The best policy is to prevent legal dispute. If it is impossible to basically exclude the possibility of dispute, however, we need to make effort to minimize the occurrence, settle fairly and divide damage equitably and feasibly. To improve the preventible death rate of our first aid system to the level of advanced country, 119 rescue team which is in charge of the stage before hospital needs to positively enforce special first aid by improving the qualitative level of rescue service and to strive to prevent legal dispute that may occur in the process.

  • PDF

A Study on Improvement of Seismic Performance of High Strength Reinforced Concrete Interior Beam-Column Joints using High Ductile Fiber-Reinforced Mortar (고인성섬유 복합모르타르를 활용한 고강도 철근콘크리트 내부 보-기둥 접합부의 내진성능 개선 연구)

  • Ha, Gee-Joo;Hong, Kun-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.6
    • /
    • pp.753-760
    • /
    • 2012
  • In this study, experimental research was carried out to evaluate and improve the constructability and seismic performance of high strength R/C interior beam-column joints regions, with or without the shear reinforcement, using high ductile fiber-reinforced mortar. Six specimens of retrofitted the beam-column joint regions using high ductile fiber-reinforced mortar are constructed and tested for their retrofit performances. Specimens designed by retrofitting the interior beam-column joint regions (IJNS series) of existing reinforced concrete building showed a stable mode of failure and an increase in load-carrying capacity due to the enhancement of crack dispersion by fiber bridging from using new high ductile materials for retrofitting. Specimens of IJNS series, designed by the retrofitting of high ductile fiber-reinforced mortar in beam-column joint regions increased its maximum load carrying capacity by 96~102.8% and its energy dissipation capacity by 0.99~1.11 folds when compared to standard specimen of SIJC with a displacement ductility of 5.

Shear Capacity of Reinforced Concrete Continuous T-Beams Externally Strengthened with Wire Rope Units (와이어로프로 외부 보강된 철근콘크리트 연속 T형 보의 전단내력)

  • Yang, Keun-Hyeok;Sim, Jae-Il;Byun, Hang-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.6
    • /
    • pp.773-783
    • /
    • 2007
  • A simple unbonded-type shear strengthening technique for reinforced concrete beams using wire rope units is developed. Six two-span continuous T-beams externally strengthened with wire rope units and an unstrengthened control beam were tested. The main variables investigated were the amount and prestressing force of wire rope units. All specimens had the same geometrical dimension and arrangement of internal reinforcement. Influence of the distribution of vertical stresses in beam web owing to the prestressing force of wire rope units on the diagonal shear cracking load and the ultimate shear capacity of beams tested is presented. Based on the current study, it can be concluded that the amount and initial prestress of wire rope should be limited to be above 2.5 times the minimum shear reinforcement ratio specified in ACI 318-05 and below 0.6 times its own tensile strength, respectively, to ensure the enhancement of shear capacity and ductile failure mode of the strengthened beams. A numerical analysis based on the upper-bound theorem is developed to assess the shear capacity of continuous T-beams strengthened with wire rope units. From the comparisons of measured and predicted shear capacities, a better agreement is achieved in the proposed numerical analysis than in empirical equations recommended by ACI 318-05.

Characteristics of amorphous IZTO-based transparent thin film transistors (비정질 IZTO기반의 투명 박막 트렌지스터 특성)

  • Shin, Han-Jae;Lee, Keun-Young;Han, Dong-Cheul;Lee, Do-Kyung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.151-151
    • /
    • 2009
  • Recently, there has been increasing interest in amorphous oxide semiconductors to find alternative materials for an amorphous silicon or organic semiconductor layer as a channel in thin film transistors(TFTs) for transparent electronic devices owing to their high mobility and low photo-sensitivity. The fabriction of amorphous oxide-based TFTs at room temperature on plastic substrates is a key technology to realize transparent flexible electronics. Amorphous oxides allows for controllable conductivity, which permits it to be used both as a transparent semiconductor or conductor, and so to be used both as active and source/drain layers in TFTs. One of the materials that is being responsible for this revolution in the electronics is indium-zinc-tin oxide(IZTO). Since this is relatively new material, it is important to study the properties of room-temperature deposited IZTO thin films and exploration in a possible integration of the material in flexible TFT devices. In this research, we deposited IZTO thin films on polyethylene naphthalate substrate at room temperature by using magnetron sputtering system and investigated their properties. Furthermore, we revealed the fabrication and characteristics of top-gate-type transparent TFTs with IZTO layers, seen in Fig. 1. The experimental results show that by varying the oxygen flow rate during deposition, it can be prepared the IZTO thin films of two-types; One a conductive film that exhibits a resistivity of $2\times10^{-4}$ ohm${\cdot}$cm; the other, semiconductor film with a resistivity of 9 ohm${\cdot}$cm. The TFT devices with IZTO layers are optically transparent in visible region and operate in enhancement mode. The threshold voltage, field effect mobility, on-off current ratio, and sub-threshold slope of the TFT are -0.5 V, $7.2\;cm^2/Vs$, $\sim10^7$ and 0.2 V/decade, respectively. These results will contribute to applications of select TFT to transparent flexible electronics.

  • PDF

Analysis of Subwavelength Metal Hole Array Structure for the Enhancement of Quantum Dot Infrared Photodetectors

  • Ha, Jae-Du;Hwang, Jeong-U;Gang, Sang-U;No, Sam-Gyu;Lee, Sang-Jun;Kim, Jong-Su;Krishna, Sanjay;Urbas, Augustine;Ku, Zahyun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.334-334
    • /
    • 2013
  • In the past decade, the infrared detectors based on intersubband transition in quantum dots (QDs) have attracted much attention due to lower dark currents and increased lifetimes, which are in turn due a three-dimensional confinement and a reduction of scattering, respectively. In parallel, focal plane array development for infrared imaging has proceeded from the first to third generations (linear arrays, 2D arrays for staring systems, and large format with enhanced capabilities, respectively). For a step further towards the next generation of FPAs, it is envisioned that a two-dimensional metal hole array (2D-MHA) structures will improve the FPA structure by enhancing the coupling to photodetectors via local field engineering, and will enable wavelength filtering. In regard to the improved performance at certain wavelengths, it is worth pointing out the structural difference between previous 2D-MHA integrated front-illuminated single pixel devices and back-illuminated devices. Apart from the pixel linear dimension, it is a distinct difference that there is a metal cladding (composed of a number of metals for ohmic contact and the read-out integrated circuit hybridization) in the FPA between the heavily doped gallium arsenide used as the contact layer and the ROIC; on the contrary, the front-illuminated single pixel device consists of two heavily doped contact layers separated by the QD-absorber on a semi-infinite GaAs substrate. This paper is focused on analyzing the impact of a two dimensional metal hole array structure integrated to the back-illuminated quantum dots-in-a-well (DWELL) infrared photodetectors. The metal hole array consisting of subwavelength-circular holes penetrating gold layer (2DAu-CHA) provides the enhanced responsivity of DWELL infrared photodetector at certain wavelengths. The performance of 2D-Au-CHA is investigated by calculating the absorption of active layer in the DWELL structure using a finite integration technique. Simulation results show the enhanced electric fields (thereby increasing the absorption in the active layer) resulting from a surface plasmon, a guided mode, and Fabry-Perot resonances. Simulation method accomplished in this paper provides a generalized approach to optimize the design of any type of couplers integrated to infrared photodetectors.

  • PDF

A Comparative Study on the Reliability Growth Enhancement Activities Using "ANALYSIS" and "TEST" through FMECA and Highly Accelerated Life Tests (신뢰성 성장 강화를 위한 Analysis 방법(FMECA)과 Test(초가속수명시험-HALT) 비교 연구)

  • Shin, Sang-Hee;Jung, Joo-Hyun;Kang, Tae-Ho;Lee, Jong-Sin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.7
    • /
    • pp.406-418
    • /
    • 2020
  • When developing weapons systems, it is important to implement the functions and performance of equipment suitable for development purposes, but it is very important to ensure that the equipment is capable of operating without any vacuum with reliability after development. Therefore, various activities are carried out to enhance reliability of equipment. Reliability is enhanced by using high-specification parts in development, reliability verification through analysis, and testing using development prototypes to reinforce and improve the parts that are lacking in equipment. However, recently, development schedules are shortened due to rapidly changing external conditions and technologies, and there are cases where sufficient reliability growth activities were not carried out due to problems such as cost. Examples are projects that perform reliability activities only in analytical methods (reliability, FMECA). In this paper, analyzing and testing methods for analysis and testing were carried out on the same equipment through FMECA and super-accelerated life test, the contents of reliability growth activity were derived, the results of design change/review were accordingly compared, the differences between the two methods were analyzed, and measures were proposed to strengthen reliable growth activities. It was concluded that reliable growth activities through analysis from the beginning of development and reliable growth activities through testing should be carried out at the completion of initial prototype production.