• Title/Summary/Keyword: Enhanced-sensitivity

Search Result 499, Processing Time 0.035 seconds

Enhanced Optical Generation of 42.7 Gbps Phase Shaped Binary Transmission

  • Ducournau, Guillaume;Latry, Olivier;Ketata, Mohamed
    • ETRI Journal
    • /
    • v.28 no.6
    • /
    • pp.826-829
    • /
    • 2006
  • A novel method for optical phase shaped binary transmission (PSBT) generation has been recently reported and experimentally evaluated. An amelioration of the optical signal-to-noise ratio (OSNR) sensitivity of the optical PSBT modulation format is proposed with the application of the concepts of enhanced electrical PSBT signal generation. Enhanced optical PSBT is proposed here as a modulation format producing a 0.7 dB gain in OSNR sensitivity compared to OPSBT, while maintaining a good robustness to group velocity dispersion: 100 ps/nm for enhanced optical PSBT and 120 ps/nm for optical PSBT, compared to 50 ps/nm for standard NRZ signals.

  • PDF

Computational integral imaging with enhanced depth sensitivity

  • Baasantseren, Ganbat;Park, Jae-Hyeung;Kim, Nam
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.718-721
    • /
    • 2008
  • Novel computational integral imaging technique with enhanced depth sensitivity is proposed. For each lateral position at a given depth plane, the dissimilarity between corresponding pixels of the elemental images is measured and used as a suppressing factor for that position. Experimental and simulation results show that reconstructed depth image on the incorrect depth plane is effectively suppressed.

  • PDF

Effects of Dietary Modification on Plasma Glucose and Insulin Sensitivity in Streptozotocin-induced Diabetic Rats

  • Choi, Hyun-Ju
    • Journal of Nutrition and Health
    • /
    • v.30 no.9
    • /
    • pp.1035-1044
    • /
    • 1997
  • There is substantial evidence that insulin sensitivity can be enhanced through appropriate dietary management . In this study, insulin sensitivity was evaluated using and insulin suppression test. Male Sprague-Dawley rats, were caused to be in a diabetic condition by the injection of streptozotocin, and divided into four groups. They were fed one of the following diets for 2 weeks : (group 1) a high-carbohydrate(CHO) low-fat low-fiber diet, (group 2) a high CHO low-fat and high-fiber diet, (group 3) a low-CHO high-fat and low-fiber diet, and (group 4) a low-CHO low-fat diet groups (as comparison between group 1 and group 2 shows). In the low-CHO high-fat diet groups, dietary fiber tended to decrease plasma glucose levels at the end of the experiment, but not significantly (as comparison between group 3 and group 4 shows). The average steady state plasma glucose level in rats on the group 3 diet was the highest among all four groups(p<0.05), indicating the poorest insulin sensitivity . However, high fiber increased insulin sensitivity in rats on the low-CHO high-fat diets(as shows by a comparison between group 3 and group 4). On the other hand , the high-CHO low-fat enhanced insulin sensitivity in rats on the low fiber diet(group 1 and group 3). The degree of enhancement of insulin sensitivity depends on the combination of CHO, fat , and fiber in the diet. In conclusion, this study demonstrates that a low-CHO high-fat low -fiber diet may be deleterious to diabetic rats. In view of insulin sensitivity enhancement , dietary fiber level is irrelevant, as long as the diet has a high-CHO and low-fat level.

  • PDF

Quercetin Enhances Cisplatin Sensitivity of Human Osteosarcoma Cells by Modulating microRNA-217-KRAS Axis

  • Zhang, Xian;Guo, Qinggong;Chen, Jingtao;Chen, Zhaohui
    • Molecules and Cells
    • /
    • v.38 no.7
    • /
    • pp.638-642
    • /
    • 2015
  • Quercetin can suppress osteosarcoma cell growth and metastasis. However, other effects of quercetin on osteosarcoma remain largely unknown. This research aims to evaluate the effects of quercetin in combination with cisplatin as treatment for osteosarcoma and investigate its regulatory mechanism. Cell viability and apoptosis in 143B cell line were determined after treatment with quercetin and/or cisplatin. RT-PCR and Western blot analysis were performed to determine the RNA or protein expression levels. Moreover, transwell assay was used to evaluate metastasis. Furthermore, rescue experiments were performed to investigate the potential regulatory mechanism of the treatment. Results showed that quercetin with concentration that was equal to or greater than $10{\mu}M$ inhibited 143B proliferation, while $5{\mu}M$ quercetin enhanced the cisplatin sensitivity of 143B cells. Expression of miR-217 was upregulated after quercetin and/or cisplatin treatment, while its target KRAS was downregulated both at mRNA and protein levels. MiR-217 knockdown led to the loss of enhanced cisplatin sensitivity while miR-217 overexpression showed the opposite effects, indicating that quercetin regulated cisplatin sensitivity by modulating the miR-217-KRAS axis. In conclusion, $5{\mu}M$ quercetin enhanced the cisplatin sensitivity by modulating the miR-217-KRAS axis. This finding suggests that quercetin may be administered with cisplatin to improve the treatment for osteosarcoma.

Design of Microstrip Defected Ground Structure-based Sensor with Enhanced-Sensitivity for Permittivity Measurement (유전율 측정을 위한 고감도 마이크로스트립 결함 접지 구조 기반 센서 설계)

  • Yeo, Junho;Lee, Jong-Ig
    • Journal of Advanced Navigation Technology
    • /
    • v.23 no.1
    • /
    • pp.69-76
    • /
    • 2019
  • In this paper, a design method for an enhanced-sensitivity microwave sensor based on microstrip defected ground structure was studied for the permittivity measurement of planar dielectric substrates. The proposed sensor was designed by modifying the ridge structure of an H-shaped aperture into the shape of a capacitor symbol. The sensitivity of the proposed sensor was compared with that of a conventional sensor based on a double-ring complementary split ring resonator(DR-CSRR). Two sensors were designed and fabricated on a 0.76-mm-thick RF-35 substrate so that the transmission coefficient would resonate at 1.5 GHz in the absence of the substrate under test. Five types of taconic substrates with a relative permittivity ranging from 2.17 to 10.2 were selected asthe substrate under test. Experiment results show that the sensitivity of the proposed sensor, which is measured by the shift in the resonant frequency of the transmission coefficient, is 1.31 to 1.62 times higher than that of the conventional DR-CSRR-based sensor.

Label-free and sensitive detection of purine catabolites in complex solutions by surface-enhanced raman spectroscopy

  • Davaa-Ochir, Batmend;Ansah, Iris Baffour;Park, Sung Gyu;Kim, Dong-Ho
    • Journal of Surface Science and Engineering
    • /
    • v.55 no.6
    • /
    • pp.342-352
    • /
    • 2022
  • Purine catabolite screening enables reliable diagnosis of certain diseases. In this regard, the development of a facile detection strategy with high sensitivity and selectivity is demanded for point-of-care applications. In this work, the simultaneous detection of uric acid (UA), xanthine (XA), and hypoxanthine (HX) was carried out as model purine catabolites by surface-enhanced Raman Spectroscopy (SERS). The detection assay was conducted by employing high-aspect ratio Au nanopillar substrates coupled with in-situ Au electrodeposition on the substrates. The additional modification of the Au nanopillar substrates via electrodeposition was found to be an effective method to encapsulate molecules in solution into nanogaps of growing Au films that increase metal-molecule contact and improve substrate's sensitivity and selectivity. In complex solutions, the approach facilitated ternary identification of UA, XA, and HX down to concentration limits of 4.33 𝜇M, 0.71 𝜇M, and 0.22 𝜇M, respectively, which are comparable to their existing levels in normal human physiology. These results demonstrate that the proposed platform is reliable for practical point-of-care analysis of biofluids where solution matrix effects greatly reduce selectivity and sensitivity for rapid on-site disease diagnosis.

Usefulness of Arterial Subtraction in Applying Liver Imaging Reporting and Data System (LI-RADS) Treatment Response Algorithm to Gadoxetic Acid-Enhanced MRI

  • Seo Yeon Youn;Dong Hwan Kim;Joon-Il Choi;Moon Hyung Choi;Bohyun Kim;Yu Ri Shin;Soon Nam Oh;Sung Eun Rha
    • Korean Journal of Radiology
    • /
    • v.22 no.8
    • /
    • pp.1289-1299
    • /
    • 2021
  • Objective: We aimed to evaluate the usefulness of arterial subtraction images for predicting the viability of hepatocellular carcinoma (HCC) after locoregional therapy (LRT) using gadoxetic acid-enhanced MRI and the Liver Imaging Reporting and Data System treatment response (LR-TR) algorithm. Materials and Methods: This study included 90 patients (mean age ± standard deviation, 57 ± 9 years) who underwent liver transplantation or resection after LRT and had 73 viable and 32 nonviable HCCs. All patients underwent gadoxetic acid-enhanced MRI before surgery. Two radiologists assessed the presence of LR-TR features, including arterial phase hyperenhancement (APHE) and LR-TR categories (viable, nonviable, or equivocal), using ordinary arterial-phase and arterial subtraction images. The reference standard for tumor viability was surgical pathology. The sensitivity of APHE for diagnosing viable HCC was compared between ordinary arterial-phase and arterial subtraction images. The sensitivity and specificity of the LR-TR algorithm for diagnosing viable HCC was compared between the use of ordinary arterial-phase and the use of arterial subtraction images. Subgroup analysis was performed on lesions treated with transarterial chemoembolization (TACE) only. Results: The sensitivity of APHE for viable HCCs was higher for arterial subtraction images than ordinary arterial-phase images (71.2% vs. 47.9%; p < 0.001). LR-TR viable category with the use of arterial subtraction images compared with ordinary arterial-phase images showed a significant increase in sensitivity (76.7% [56/73] vs. 63.0% [46/73]; p = 0.002) without significant decrease in specificity (90.6% [29/32] vs. 93.8% [30/32]; p > 0.999). In a subgroup of 63 lesions treated with TACE only, the use of arterial subtraction images showed a significant increase in sensitivity (81.4% [35/43] vs. 67.4% [29/43]; p = 0.031) without significant decrease in specificity (85.0% [17/20] vs. 90.0% [18/20]; p > 0.999). Conclusion: Use of arterial subtraction images compared with ordinary arterial-phase images improved the sensitivity while maintaining specificity for diagnosing viable HCC after LRT using gadoxetic acid-enhanced MRI and the LR-TR algorithm.

Improvement of Sensing Performance on Nasicon Amperometric NO2 Sensors (나시콘 전류검출형 NO2 센서의 성능개선)

  • Kim, Gwi-Yeol
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.10
    • /
    • pp.912-917
    • /
    • 2007
  • Many electrochemical power devices such as solid state batteries and solid oxide fuel cell have been studied and developed for solving energy and environmental problems. An amperometric gas sensor usually generates sensing signal of electric current along the proportion of the concentration of target gas under the condition of limiting current. For narrow variations of gas concentration, the amperometric gas sensor can show higher precision than a potentiometric gas sensor does. In additional, cross sensitivities to interfering gases can possibly be mitigated by choosing applied voltage and electrode materials properly. In order to improve the sensitivity to $NO_2$, the device was attached with Au reference electrode to form the amperometric gas sensor device with three electrodes. With the fixed bias voltage being applied between the sensing and counter electrodes, the current between the sensing and reference electrodes was measured as a sensing signal. The response to $NO_2$ gas was obviously enhanced and suppressed with a positive bias, respectively, while the reverse current occurred with a negative bias. The way to enhance the sensitivity of $NO_2$ gas sensor was thus realized. It was shown that the response to $NO_2$ gas could be enhanced sensitivity by changing the bias voltage.

Role of $^{18}F$-fluorodeoxyglucose PET/CT in Recurrent Ovary Cancer (재발 난소암의 진단에서의 $^{18}F$-fluorodeoxyglucose PET/CT의 유용성: Enhanced CT와 Tumor Marker CA 125와의 비교)

  • O, Joo-Hyun;Yoo, Ie-Ryung;Choi, Woo-Hee;Lee, Won-Hyoung;Kim, Sung-Hoon;Chung, Soo-Kyo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.3
    • /
    • pp.209-217
    • /
    • 2008
  • Purpose: To date, anatomical imaging modalities of the pelvis and tumor markers have been the mainstay of surveillance for recurrent ovary cancer. This study aimed to assess the role of $^{18}F$-FDG PET/CT in evaluation of ovary cancer recurrences, especially in comparison with enhanced a and tumor marker CA 125. Materials and methods: 73 patients who had PET/CT scan for restaging of confirmed ovary cancer, and additional imaging with enhanced a of the pelvis within one month were included. CA 125 level was available in all patients. From the PET/CT images, maximum standard uptake values (SUVmax) of suspected recurrence sites were recorded. Confirmation was available through re-operation or biopsy in 26 cases, and clinical assessment with series of follow-up images in 47. Results: PET/CT had 93% sensitivity and 88% specificity for detecting recurrent ovary cancer. Enhanced a of pelvis had sensitivity and specificity of 83% and 88%, and CA 125 50% and 95%. Conclusion: PET/CT has higher sensitivity for detecting recurrent ovary cancer compared to enhanced a though the differences were not significant. PET/CT has significantly higher sensitivity than CA 125. However, the three tests all agreed in only 43% of the recurrence cases, and recurrence should be suspected when any of the tests, especially PET/CT, show positive findings.

Sensitivity Analysis of the Structural Characteristics of the MOS Capacitors for Sensing the Ionizing Radiation Effects (전리방사선 센서용 MOS Capacitors의 구조적 변화에 따른 감도 특성 분석)

  • Hwang, Young-Gwan;Lee, Nam-Ho;Lee, Hyun-Jin
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1181-1182
    • /
    • 2008
  • The study presents the results of the analysis on the structural characteristics of MOS capacitor for sensing the ionizing radiation effect. Increasing the thickness of MOS capacitor's oxide layer enhanced the sensitivity of MOS capacitor under irradiation condition, but the sensitivity of irradiated MOS capacitor is uninfluenced by the area of MOS capacitor.

  • PDF