• Title/Summary/Keyword: Enhanced Brain CT

Search Result 21, Processing Time 0.024 seconds

CT Scan Findings of Rabbit Brain Infection Model and Changes in Hounsfield Unit of Arterial Blood after Injecting Contrast Medium (토끼 뇌감염 모델의 CT 소견과 조영제 주입 후 동맥혈의 Hounsfield Unit의 변화)

  • Ha, Bon-Chul;Kwak, Byung-Kook;Jung, Ji-Sung
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.9
    • /
    • pp.270-279
    • /
    • 2012
  • This paper explores CT findings of a rabbit brain infection model injected with Escherichia coli and investigates the changes in Hounsfield unit (HU) of arterial blood over time. The brain infection model was produced by injecting E. coli $1{\times}10^7$ CFU/ml, 0.1 ml through the burr hole in the calvarium; 2~3 mm in depth from the dura mater, and contrast-enhanced CT, dynamic CT and arterial blood CT images were gained. It was found that various brain infections such as brain abscess, ventriculitis and meningitis. The CT image of brain abscess showed a typical pattern which the peripheral area was strongly contrast-enhanced while the center was weakly contrast-enhanced. The CT image of ventriculitis showed a strong contrast-enhancement along the lateral ventricle wall, and the CT image of meningitis showed a strong contrast-enhancement in the area between the telencephalon and the diencephalon. In dynamic CT images, the HU value of the infection core before injecting contrast medium was $31.01{\pm}3.55$. By 10 minutes after the injection, the value increased gradually to $40.36{\pm}3.76$. The HU value in the areas of the marginal rim where was hyper-enhanced showed $47.23{\pm}3.12$ before contrast injection, and it increased to $63.59{\pm}3.31$ about 45 seconds after the injection. In addition, the HU value of the normal brain tissue opposite to the E. coli. injected brain was $39.01{\pm}3.24$ before the injection, but after the contrast injection, the value increased to $49.01{\pm}4.29$ in about 30 seconds, and then it showed a gradual decline. In the arterial blood CT, the HU value before the contrast injection was $87.78{\pm}6.88$, and it increased dramatically between 10 to 30 seconds until it reached a maximum value of $749.13{\pm}98.48$. Then it fell sharply to $467.85{\pm}62.98$ between 30 seconds to 45 seconds and reached a plateau by 60 seconds. Later, the value showed a steady decrease and indicated $188.28{\pm}25.03$ at 20 minutes. Through this experiment, it was demonstrated that the brain infection model can be produced by injecting E. coli., and the characteristic of the infection model can be well observed with contrast-enhanced CT scan. The dynamic CT scan showed that the center of the infection was gradually contrast-enhanced, whereases the peripheral area was rapidly contrast-enhanced and then slowly decreased. As for arterial blood, it increased significantly between 10 seconds to 30 seconds after the contrast medium injection and decreased gradually after reaching a plateau.

Enhancing Medical Images by New Fuzzy Membership Function Median Based Noise Detection and Filtering Technique

  • Elaiyaraja, G.;Kumaratharan, N.
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.5
    • /
    • pp.2197-2204
    • /
    • 2015
  • In recent years, medical image diagnosis has growing significant momentous in the medicinal field. Brain and lung image of patient are distorted with salt and pepper noise is caused by moving the head and chest during scanning process of patients. Reconstruction of these images is a most significant field of diagnostic evaluation and is produced clearly through techniques such as linear or non-linear filtering. However, restored images are produced with smaller amount of noise reduction in the presence of huge magnitude of salt and pepper noises. To eliminate the high density of salt and pepper noises from the reproduction of images, a new efficient fuzzy based median filtering algorithm with a moderate elapsed time is proposed in this paper. Reproduction image results show enhanced performance for the proposed algorithm over other available noise reduction filtering techniques in terms of peak signal -to -noise ratio (PSNR), mean square error (MSE), root mean square error (RMSE), mean absolute error (MAE), image enhancement factor (IMF) and structural similarity (SSIM) value when tested on different medical images like magnetic resonance imaging (MRI) and computer tomography (CT) scan brain image and CT scan lung image. The introduced algorithm is switching filter that recognize the noise pixels and then corrects them by using median filter with fuzzy two-sided π- membership function for extracting the local information.

Supratentorial Gangliocytoma Mimicking Extra-axial Tumor: A Report of Two Cases

  • Ho Sung Kim;Ho Kyu Lee;Ae Kyung Jeong;Ji Hoon Shin;Choong Gon Choi;Shin Kwang Khang
    • Korean Journal of Radiology
    • /
    • v.2 no.2
    • /
    • pp.108-112
    • /
    • 2001
  • We report two cases of supratentorial gangliocytomas mimicking an extra-axial tumor. MR imaging indicated that the tumors were extra-axial, and meningiomas were thus initially diagnosed. Relative to gray matter, the tumors were hypointense on T1-weighted images and hyperintense on T2-weighted images. On contrast-enhanced T1-weighted images, homogeneous enhancement was observed, while CT scanning revealed calcification in one of the two cases.

  • PDF

Image Registration for High-Quality Vessel Visualization in Angiography (혈관조영영상에서 고화질 혈관가시화를 위한 영상정합)

  • Hong, Helen;Lee, Ho;Shin, Yeong-Gil
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2003.11a
    • /
    • pp.201-206
    • /
    • 2003
  • In clinical practice, CT Angiography is a powerful technique for the visualziation of blood flow in arterial vessels throughout the body. However CT Angiography images of blood vessels anywhere in the body may be fuzzy if the patient moves during the exam. In this paper, we propose a novel technique for removing global motion artifacts in the 3D space. The proposed methods are based on the two key ideas as follows. First, the method involves the extraction of a set of feature points by using a 3D edge detection technique based on image gradient of the mask volume where enhanced vessels cannot be expected to appear, Second, the corresponding set of feature points in the contrast volume are determined by correlation-based registration. The proposed method has been successfully applied to pre- and post-contrast CTA brain dataset. Since the registration for motion correction estimates correlation between feature points extracted from skull area in mask and contrast volume, it offers an accelerated technique to accurately visualize blood vessels of the brain.

  • PDF

Gas-Forming Brain Abscess Caused by Klebsiella Pneumoniae

  • Cho, Keun-Tae;Park, Bong-Jin
    • Journal of Korean Neurosurgical Society
    • /
    • v.44 no.6
    • /
    • pp.382-384
    • /
    • 2008
  • Gas forming brain abscess is a rare disease caused by Klebsiella pneumoniae occurring in patients with impaired host defense mechanism such as diabetes mellitus or liver cirrhosis. A 59-year-old man with 2-year history of diabetes mellitus and 20-year history of liver cirrhosis presented to the hospital with headache. On the day after admission, severe headache was developed and he deteriorated rapidly. Brain CT showed a non-enhanced mass including multiple air density as well as surrounding edema seen in the right occipital lobe, and isodensity air-fluid level seen in the right lateral ventricle. Despite emergent ventricular drainage and intraventricular and intravenous administration of antibiotics, his condition progressively worsened to sepsis and to death after 5 days. Bacterial culture of blood and ventricular fluids disclosed a Gram (-) rod, Klebsiella pneumoniae. In this report we review the pathogenic mechanism and its management.

Comparison of bone subtraction CT angiography with standard CT angiography for evaluating circle of Willis in normal dogs

  • Soyon An;Gunha Hwang;Rakhoon Kim;Tae Sung Hwang;Hee Chun Lee
    • Journal of Veterinary Science
    • /
    • v.24 no.5
    • /
    • pp.65.1-65.9
    • /
    • 2023
  • Background: Bone subtraction computed tomography angiography (BSCTA) is a useful alternative technique for improving visualization of vessels surrounded by skull bone. However, no studies have compared computed tomography angiography (CTA) and BSCTA for improving the visibility of canine cerebral blood vessels. Objectives: To evaluate the potential benefit of BSCTA for better delineation of brain arteries of the circle of Willis (CoW) in dogs by comparing BSCTA with non-subtraction computed tomography angiography (NSCTA). Methods: Brain CTA was performed for nine healthy beagle dogs using a bolus tracking method with saline flushing. A total dose of 600 mgI/kg of contrast agent with an iodine content of 370 mgI/mL was injected at a rate of 4 ml/s. Bone removal was achieved automatically by subtracting non-enhanced computed tomography (CT) data from contrast CT data. Five main intracranial arteries of the CoW were analyzed and graded on a scale of five for qualitative evaluation. Results: Scores of basilar artery, middle cerebral artery, and rostral cerebral artery in the BSCTA group were significantly higher than those in the NSCTA group (p = 0.001, p = 0.020, and p < 0.0001, respectively). Scores of rostral cerebellar artery (RcA) and caudal cerebral artery (CCA) did not differ significantly between the two groups. However, scores of RcA and CCA in the BSCTA group were higher than those in the NSCTA group. Conclusions: BSCTA improved visualization of intracranial arteries of the CoW with close contact to bone. Thus, it should be recommended as a routine scan method in dogs suspected of having brain vessel disease.

Glioblastoma Misdiagnosed as Brain Abscess after Surgical Evacuation of Spontaneous Basal Ganglia Hemorrhage (기저핵부 뇌실질내 출혈에 대한 수술후 뇌농양으로 오인한 다형성 교아세포종)

  • Cheong, Jin Hwan;Kim, Jae Min;Bak, Koang Hum;Park, Yong Wook;Kim, Choong Hyun;Oh, Suck Jun
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.3
    • /
    • pp.384-388
    • /
    • 2001
  • A 51-year-old woman presented with sudden severe headache, vomiting, and right hemiparesis at first admission. Computed tomography(CT) scans revealed an hemorrhagic density at left basal ganglia. Preoperative cerebral angiography showed no vascular lesion. Under the diagnosis of hypertensive intracerebral hemorrhage(ICH), total extirpation of hematoma was done. The postoperative neurological condition improved gradually and discharged without any neurological sequelae. Two months later, she revisited with headache, vomiting and progressive right hemiparesis. CT scans at second admission showed an irregular rim enhanced mass with central low density with surrounding edema at the initial bleeding area. Repeated craniotomy was performed and the mass was partially removed. The histopathological diagnosis of the specimen was confirmed as glioblastoma. The authors report a glioblastoma, which occurred at initial ICH site and regarded as a brain abscess with literature review.

  • PDF

An Atypical Choroid Plexus Papilloma Initially Manifestating as Radicular Symptoms (방사성 증상이 초기 증상으로 나타난 비정형 맥락막 신경총 유두종)

  • Lee, Cheol-Jae;Kim, Jun-Hyung;Kim, Yunhee;Lee, Jang-Bo;Ryu, Byungju
    • Clinical Pain
    • /
    • v.20 no.1
    • /
    • pp.39-42
    • /
    • 2021
  • A 29-year-old woman had 1-month history of back pain radiating into lower extremities, motor weakness, and sensory abnormalities in both lower extremities. Contrast-enhanced spinal magnetic resonance imaging (MRI) revealed a homogeneously enhancing mass at the T12~L1 and several intradural enhancing nodular lesions at L2~S1. Tumor resection surgery was performed and following histological examination showed that the tumor satisfied the diagnostic criteria for atypical choroid plexus papilloma (CPP). To find primary tumor sites, contrast-enhanced brain MRI, whole spine MRI, and PET-CT were carried out and additional lesions were detected at the fourth ventricle, right cerebellum, and upper thoracic spinal cord. This is a very rare case of metastatic atypical CPP that involves brain, upper thoracic spinal cord, and cauda equina with initial manifestation of radicular symptoms without clinical signs of primary brain lesion.

Glioma Mimicking a Hypertensive Intracerebral Hemorrhage

  • Choi, Go;Park, Dong-Hyuk;Kang, Shin-Hyuk;Chung, Yong-Gu
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.2
    • /
    • pp.125-127
    • /
    • 2013
  • Here, we report a rare case of an anaplastic astrocytoma masquerading as a hypertensive basal ganglia hemorrhage. A 69-year-old woman who had been under medical management for hypertension during the past 3 years suddenly developed right hemiparesis with dysarthria. Brain computed tomography (CT) scans with contrast and CT angiograms revealed an intracerebral hemorrhage (ICH) in the left basal ganglia, without an underlying lesion. She was treated conservatively, but underwent a ventriculoperitoneal shunt operation 3 months after the initial attack due to deteriorated mental status and chronic hydrocephalus. Three months later, her mental status deteriorated further. Magnetic resonance imaging (MRI) with gadolinium demonstrated an irregular enhanced mass in which the previous hemorrhage occurred. The final histological diagnosis which made by stereotactic biopsy was an anaplastic astrocytoma. In the present case, the diagnosis of a high grade glioma was delayed due to tumor bleeding mimicking hypertensive ICH. Thus, a careful review of neuroradiological images including MRI with a suspicion of tumor bleeding is needed even in the patients with past medical history of hypertension.

Fabrication of a Brain Model using the Adaptive Slicing Technique (적응단면기법을 이용한 뇌모형제작)

  • Yeom, Sang-Won;Um, Tai-Joon;Joo, Yung-Chul;Kim, Seung-Woo;Kong, Yong-Hae;Chun, In-Gook;Bang, Jae-Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.4
    • /
    • pp.485-490
    • /
    • 2003
  • RP(Rapid Prototyping) has been used in the various industrial applications. This paper presents the optimization techniques fur fabricated 3D model design using RP machine for the medical field. Once the original brain model data are obtained from 2D slices of MRI/CT machine, the data can be modeled as an optimal ellipse. The objective of this study includes optimization of fabrication time and surface roughness using the adaptive slicing method. It can reduce fabrication time without losing surface roughness quality by accumulating the slices with variable thickness. According to the parameter tuning and synthesis of its effect, more suitable parameter values can be obtained by enhanced 3D brain model fabrication. Therefore, accurate 3D brain model fabricated by RP machine can enable a surgeon to perform pre-operation. to make a decision for the operation sequence and to perceive the 3D positions in prototype, before delicate operation of actual surgery.