• Title/Summary/Keyword: Engine-generating system

Search Result 60, Processing Time 0.022 seconds

A Study on Generating efficiency of the Double Acting Stirling Engine/Generator (양방향 스털링엔진/발전기의 효율 특성 연구)

  • PARK, SEONGJE;KO, JUNSEOK;HONG, YONGJU;KIM, HYOBONG;YEOM, HANKIL;IN, SEHWAN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.1
    • /
    • pp.114-120
    • /
    • 2016
  • This paper describes generating efficiency characteristics of the double acting Stirling engine/generator for domestic small-scale CHP (Combined Heat and Power) system. In small distributed generation applications, Stirling engine has competition from fuel cell, microturbine and etc. In order to be economical in the applications, a long life with minimum maintenance is generally required. Free piston Stirling engine (FPSE) has no crank and rotating parts to generate lateral forces and require lubrication. Double acting Stirling engine/generator has one displacer and two power piston which are supported by flexure springs. Two power pistons oscillate with symmetric displacement and are connected with moving magnet type linear generators for power generation from PV work. In experiments, 1 kW class double acting free piston Stirling engine/generator is fabricated and tested. Heat is supplied to hot end of engine by the combustion of natural gas and converted to electric power by linear generators which are assembled with power pistons. The electric parameters such as voltage, current and phase are measured with for variable flow rate of fuel gas. Especially, generating efficiency of FPSE is measured with three different measurement methods. Generating efficiency of the double acting Stirling engine/alternator is about 24%.

Design of Vehicle Control Algorithm and Engine-generator Control for Drivability of Range-extended Electric Vehicle (주행거리 연장형 전기자동차의 차량제어 알고리즘 설계 및 운전성 확보를 위한 엔진 발전시스템 제어)

  • Park, Youngkug
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.6
    • /
    • pp.649-659
    • /
    • 2016
  • This paper describes control algorithm and control structure of vehicle control unit for range-extended electric vehicle equipped with engine-generator system, and specially presents methods which determine optimal operating points and decreases a vibration or a shock for operating the engine-generating system. The vehicle control algorithm is consisted of several parts which are sequence control, calculation of wheel demand torque, determination of operating points, and management of operating points and so vehicle controller has be made possible to efficiently manage calibration parameters. The control algorithm is evaluated by driving test modes, launching performance and operating engine-generator system and so on. In conclusion, this paper present methods for extending a mileage, improving a launching performance and reducing vibration or shock when the engine-generating system is starting or is stopping.

Starting Mode Analysis of Flat-type Linear Generator for Free-Piston Engine (Free-Piston 엔진용 평판형 선형 발전기를 이용한 기동모드 해석)

  • Kim, Young-Wook;Lim, Jae-Won;Jung, Hyun-Kyo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.6
    • /
    • pp.966-971
    • /
    • 2008
  • Free-piston engine system is a new type energy converter which uses a linear motion of piston by using linear generator. In free-piston engine system, the piston is not connected to a crank-shaft. The major advantages of free-piston engine system are high efficiency and low mechanical loss from the absence of motion conversion devices. Linear generator of free-piston engine system is used as generator and starting motor. In design step, considering of back-emf and detent force characteristics for generating mode and thrust and control characteristics for starting mode is needed. In this research, generating mode of flat-type linear generator and tubular-type linear generator is analyzed by finite element analysis method and starting mode of both type linear generators is analyzed by using capability curve. Capability curve is plotted from electrical parameters of both type linear generator and motion profile is calculated from mechanical parameters.

Photovoltaic Generating System on Ships to Reduce Fossil Fuel Dependence (선박에서 화석연료 의존도 절감을 위한 태양광 발전)

  • Takeshi Katagi;Yoshimi Fujii;Eiichi Nishikawa;Takeshi Hashimoto;Kenji Ishida
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.3
    • /
    • pp.44-54
    • /
    • 1996
  • The release of polluting gases such as NO/sub x/ of SO/sub x/ to the atmosphere from ships is causing increasing concern. To reduce destruction to the marine environment, the value of the utilization of photovoltaic energy is highly appreciated since photovoltaic energy is and alternate clean energy source to fossil fuels. The use of a photovoltaic generating system to supplement diesel engine driven electric power system on ships has been studied. The design of the photovoltaic generating system based on a photovoltaic array is presented in this paper. The amount of NO/sub x/ and SO/sub x/ emission is found to be significantly reduced for a small vessel operated within a harbour after a photovoltaic generating system is installed to supplement the diesel engine generator system.

  • PDF

Photovoltaic Generating System on Ships to Reduce Fossil Fuel Dependence (선박에서 화석연료 의존도 절감을 위한 태양광 발전)

  • Takeshi Katagi;Yoshimi Fujii;Eiichi Nishikawa;Takeshi Hashimoto;Kenji Ishida
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.3
    • /
    • pp.176-176
    • /
    • 1996
  • The release of polluting gases such as NOx of SOx to the atmosphere from ships is causing increasing concern. To reduce destruction to the marine environment, the value of the utilization of photovoltaic energy is highly appreciated since photovoltaic energy is and alternate clean energy source to fossil fuels. The use of a photovoltaic generating system to supplement diesel engine driven electric power system on ships has been studied. The design of the photovoltaic generating system based on a photovoltaic array is presented in this paper. The amount of NOx and SOx emission is found to be significantly reduced for a small vessel operated within a harbour after a photovoltaic generating system is installed to supplement the diesel engine generator system.

Development of 10ton Thrust Liquid Rocket Engine using LOX+LNG with Turbopump System called CHASE-10 (액체산소와 액체메탄을 사용하며, 고압터보펌프가 장착된 추력 10톤급 액체로켓엔진 CHASE-10의 개발)

  • Kim Kyoung-Ho
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.181-184
    • /
    • 2006
  • We successfully completed the development test for a 10-ton thrust liquid rocket engine using LOX+LNG (Liquefied Natural Gas, or Methane) with a high performance turbopump system. Resulting from the success of the regenerative-cooling capability using LNG, high pressure-generating capability and gas-generating performance, etc, methane engine with the product name CHASE-10 will be commercialized in the near future.

  • PDF

Characteristics on Stand-alone Operation of a Doubly-fed Induction Generator Applied to Adjustable Speed Gas Engine Cogeneration System

  • Daido, Tetsuji;Miura, Yushi;Ise, Toshifumi;Sato, Yuki
    • Journal of Power Electronics
    • /
    • v.13 no.5
    • /
    • pp.841-853
    • /
    • 2013
  • An application of doubly-fed induction generator (DFIG), which is one of adjustable speed generators, to a gas engine cogeneration system has been investigated. To operate during a blackout as an emergency power supply is one of important roles for the gas engine cogeneration system. However, the DFIG requires initial excitation for startup during a blackout because the DFIG has no excitation source. In this paper, we propose the "blackout start" as a new excitation method to generate a rated voltage at the primary side during a blackout. In addition, a stand-alone operation following a blackout has been investigated by using experimental setup with a real gas engine. Power flows in the generating set with the DFIG at the stand-alone operation have been investigated experimentally. Experimental investigation of the power flow suggests that the generating set with DFIG has optimal speed in minimizing whole system losses.

Development of Engine Simulator for The Optimal Control System Implementation of Gas Turbine Engine (가스터빈엔진 최적 제어시스템 구현을 위한 엔진 시뮬레이터 개발)

  • Lim, H.S.;Cha, Y.B.;Lee, B.S.;Kim, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2082-2085
    • /
    • 2002
  • This paper describes the development of a gas turbine engine simulator in detail. The simulator presented in this paper has a mathematical engine model based on a target gas turbine engine performance data and is developed for generating a gas turbine engine sensor signals between the hardwares and softwares of a gas turbine engine control system using Data Acquisition systems(DAS) and 1553B communication, a aeronautic standard communication specification. In addition, this paper proves the excellent performance of this simulator by showing the results of a gas turbine engine field test and simulation.

  • PDF

Design Characteristics on the Hybrid Power System for Quad-Tilt Prop (쿼드-틸트프롭 하이브리드 동력시스템 설계 특성)

  • Kim, Keunbae;Lee, Bohwa
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.1196-1199
    • /
    • 2017
  • A series-hybrid power system was designed for quad-tilt prop UAV and the characteristics was analysed. The power system consists of a 4.5kW rotary engine-generator and a li-battery as power sources, a power controller manages the overall power and supplies to the vehicle system. The output power of the engine is to be matched with the generator performance considering mechanical driving loss and generating efficiency, and also loss for charging and discharging of the battery energy. It is applied that the constant speed operation of the engine-generator to minimize overall fuel consumption by integrating the generating power and the battery energy, consequentially the battery capacity and characteristics could be important factors for improvement of the system efficiency.

  • PDF

The Interconnection Technology of Small Self-generating System with Distribution Line

  • Park, Kyung-sun;Chiu Hwang
    • Journal of Energy Engineering
    • /
    • v.8 no.1
    • /
    • pp.76-84
    • /
    • 1999
  • The demand of Small Self-generating System (SSS) including Small Cogeneration System (SCS) is constantly increasing with the need of electricity and/or thermal in office, hospital, hotel, and small factory, etc. It is especially recommended to operate SCS in the heat-following mode to maximize the efficiency of generator. In case of the heat-following mode SCS has got to be connected to distribution system so as to send surplus power to the utility or receive the short power from utility. But the interconnection of SSS with distribution system causes a few problems such as the bad power quality, and low security. If SSS is not promptly disconnected after faults occur (Islanding of SSS), it can not only damage equipment of utility and adjacent customers but also endanger life of human due to overvoltage or overcurrent. In this paper it has been deeply discussed if interconnection of engine self-generator/control system satisfies the protective requirement for SSS or not. 500 kW engine generator running in the Jodo island has been used to perform the analysis of interconnection.

  • PDF