• Title/Summary/Keyword: Energy-saving plan

Search Result 126, Processing Time 0.027 seconds

A Study on the Feasibility of the Timing for the Implementation of Energy-Saving Plan of Buildings Based on the Approval of Business Plan and Construction Permit (건축물에너지절약계획서의 사업계획승인, 건축허가에 따른 적용시점의 타당성 연구)

  • Kim, Dae-Won;Kim, Young-Il;Chung, Kwang-Seop
    • Journal of Energy Engineering
    • /
    • v.21 no.3
    • /
    • pp.265-270
    • /
    • 2012
  • The delay in the construction permit for the building, which obtained the approval of business proposal, may lead to a difference in the maintenance cost ranging between 20% and 30% in the neighborhood where the residents moved in, along with the new project under construction in the surrounding area amidst rigorous regulations that aim to promote energy-saving and the heightened interest of the public in energy conservation, and such problem would become the major source of serious public complaints. Thus, the energy-saving plan needs to be prepared when the approval is granted to the business plan. In order to prevent public complaints or ensure effectiveness of government's energy plan, it may be effective to apply the energy-saving plan based on current standards upon the award of construction permit when two years have elapsed since the date of the scheduled commencement of construction or when the start of construction is delayed as stipulated in the Article 18 of the Enforcement Decree of Housing Act. If the energy-saving plan and related technologies are merely the parts of license and permit process without fully serving their purposes and functions, it would be waste of time to deploy a lot of workforce and review and seek consultation. The government or owners of buildings need to fully understand the energy-saving aspects and exert effort to enhance the energy efficiency of buildings.

Energy Efficiency Evaluation of IT based Ship Energy Saving System-(2) : Ship Test Results (IT기반의 선박에너지절감시스템 성능평가 방법-(2) : 해상시험 수행 결과)

  • Yoo, Yun-Ja
    • Journal of Navigation and Port Research
    • /
    • v.40 no.4
    • /
    • pp.165-171
    • /
    • 2016
  • SEEMP (Ship Energy Efficiency Management Plan) has entered into force since 2013 for the reduction of GHG emission of operating ships. SEEMP guidelines include the hardware modification or installation of energy-saving device on ship. It also includes software based energy-saving technology such as optimum routing, speed optimization, etc. Hardware based technologies are not easy to apply to ongoing vessel due to the operational restriction. Therefore, IT based energy-saving technology was applied and its energy efficiency was evaluated using before and after energy-saving system applied voyage data. SEEMP advises a voluntary participation of EEOI (Ship Energy Efficiency Operation Indicator) use as an indicator of ship energy efficiency operation, and those results were also shown to evaluate the improvement efficiency of energy-saving system.

The Effect of Energy-Saving Investment on Reduction of Greenhouse Gas Emissions (에너지절약투자의 온실가스 배출 감소 효과)

  • Kim, Hyeon;Jeong, Kyeong-Soo
    • Environmental and Resource Economics Review
    • /
    • v.9 no.5
    • /
    • pp.925-945
    • /
    • 2000
  • This paper analyses the impact of energy-saving investment on Greenhouse gas emissions using a model of energy demand in Korea. SUR method was employed to estimate the demand equation. The econometric estimates provide information about the energy price divisia index, sector income, and energy saving-investment elasticities of energy demand. Except for energy price divisia, the elasticities of each variable are statistically significant. Also, the price and substitution elasticities of each energy price are similar to the results reported by the previous studies. The energy-saving investment is statistically significant and elasticities of each sector is inelastic. Using the coefficient of energy-saving investment and carbon transmission coefficient, the amount of reduction of energy demand and the reduction of carbon emissions can be estimated. The simulation is performed with the scenario that the energy-saving investment increase by 10~50%, keeping up with Equipment Investment Plan of 30% increase in energy-saving investment by 2000. The results show that the reduction of energy demand measured as 11.2% based upon 1995's level of the energy demand, in industrial sector. Accordingly, the carbon emissions will be reduced by 11.3% based upon 1995's level of the carbon emissions in industrial sector.

  • PDF

An Energy Performance Comparison of University Lecture Facilities for Energy Saving Building Design (에너지 절약형 건축물 설계를 위한 대학 강의동 형태별 에너지 성능 비교에 관한 연구)

  • Kim, Tae-Hoon;Seo, Ji-Hyo;Choo, Seung-Yeon
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.11
    • /
    • pp.105-112
    • /
    • 2018
  • Global environmental problems are growing, and the importance of buildings with high energy consumption has been emphasized. In Korea, the Ministry of Land, Transport and Maritime Affairs has been promoting the mandatory zero energy building since 2020, and guidelines related to the zero energy building have been developed. In addition, based on the "Energy-saving Design Criteria for Buildings" of the "Green Building Promotion Act" in Korea, the standards for energy-saving design are specified and the energy saving plan is written. Besides, the 'Energy-saving construction standards for eco-friendly houses' also specify insulation, machinery, equipment, and sunshade. Also, there is little consideration about the cost such as construction cost and material cost which should be considered important in the construction stage. Therefore, this study aims at analysis of building type and energy performance versus materials for energy saving building design considering energy performance in planning aspect of initial design stage. In this study, because the variables can not be neglected in this study, it is selected as the lecture facility of the 'K' university campus building which can consider the remaining factors except the passive design element as the control variable, Energy performance analysis.

Cost-Effective Model for Energy Saving in Super-Tall Building

  • Song, Kwonsik;Park, Moonseo;Lee, Hyun-Soo;Kim, Sooyoung;Shin, Jinho
    • Journal of Construction Engineering and Project Management
    • /
    • v.3 no.3
    • /
    • pp.17-22
    • /
    • 2013
  • In many urban cities, super-tall buildings have been being constructed around New York and Chicago as the center since 1930 to improve the efficiency of land use and respond to new residential type. In terms of energy consumption, super-tall buildings are classified as a top energy consumption building. Also, as time passed, the degradation of energy performance occurs in super-tall buildings like general things so that these cannot show the initial performance planned in the design phase. Accordingly, building owners need to make a plan to apply energy saving measures to existing building during the operation phase. In order to select energy saving measures, calculus-based methods and enumerative schemes have been typically used. However, these methods are time-consuming and previous studies which used these methods have problems with not considering the initial construction cost. Consequently, this study proposes a model for selecting an optimal combination of energy saving measures which derives maximum energy saving within allowable cost using genetic algorithms. As a contribution of this research, it would be expected that a model is utilized as one of the decision-making tools during the planning stage for energy saving.

COST-EFFECTIVE MODEL FOR ENERGY SAVING IN SUPER-TALL BUILDING

  • Kwonsik Song;Moonseo Park;Hyun-Soo Lee;Sooyoung Kim;Jinho Shin
    • International conference on construction engineering and project management
    • /
    • 2013.01a
    • /
    • pp.294-299
    • /
    • 2013
  • In many urban cities, super-tall buildings have been being constructed around New York and Chicago as the center since 1930 to improve the efficiency of land use and respond to new residential type. In terms of energy consumption, super-tall buildings are classified as a top energy consumption building. Also, as time passed, the degradation of energy performance occurs in super-tall buildings like general things so that these cannot show the initial performance planned in the design phase. Accordingly, building owners need to make a plan to apply energy saving measures to existing building during the operation phase. In order to select energy saving measures, calculus-based methods and enumerative schemes have been typically used. However, these methods are time-consuming and previous studies which used these methods have problems with not considering the initial construction cost. Consequently, this study proposes a model for selecting an optimal combination of energy saving measures which derives maximum energy saving within allowable cost using genetic algorithms. As a contribution of this research, it would be expected that a model is utilized as one of the decision-making tools during the planning stage for energy saving.

  • PDF

Energy Efficiency Evaluation of IT based Ship Energy Saving System-(1) : Ship Handling Simulator Test Results (IT 기반의 선박에너지절감시스템 성능평가 방법-(1) : 육상시험 수행 결과)

  • Yoo, Yun-Ja
    • Journal of Navigation and Port Research
    • /
    • v.39 no.6
    • /
    • pp.465-472
    • /
    • 2015
  • SEEMP (Ship Energy Efficiency Management Plan) guidelines for a ship's GHG reduction include a machinery modification of hull, an installation of energy efficiency enhanced attachment in hardware methods. It is also possible to bring a ship energy efficiency improvement by fuel-efficient operations or in other software methods. Hardware modification or installation on ship can bring financial burdens to a ship company compared to its improvement expectation. On the other hand, Software based energy-saving technology can be applicable on various ship types, and it is also expected high efficiency of ship energy use compared to hardware based technology in perspective of the investment costs and efficiency. In this paper, it is described that the ship handling simulator based evaluation was carried out using representative ship model of bulk, container and VLCC. Simulation environments were separated into 6 conditions according to the sea-state and weather condition, and the operation results were compared with those before and after energy saving system applied The container ship showed the largest FOC save rate after energy saving system applied although the others also showed energy save rate after using the system.

In-Situ Diagnosis of Vapor-Compressed Chiller Performance for Energy Saving

  • Shin Younggy;Kim Youngil;Moon Guee-Won;Choi Seok-Weon
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.8
    • /
    • pp.1670-1681
    • /
    • 2005
  • In-situ diagnosis of chiller performance is an essential step for energy saving business. The main purpose of the in-situ diagnosis is to predict the performance of a target chiller. Many models based on thermodynamics have been proposed for the purpose. However, they have to be modified from chiller to chiller and require profound knowledge of thermodynamics and heat transfer. This study focuses on developing an easy-to-use diagnostic technique that is based on adaptive neuro-fuzzy inference system (ANFIS). The effect of sample data distribution on training the ANFIS is investigated. It is found that the data sampling over 10 days during summer results in a reliable ANFIS whose performance prediction error is within measurement errors. The reliable ANFIS makes it possible to prepare an energy audit and suggest an energy saving plan based on the diagnosed chilled water supply system.

Effect analysis of geothermal cooling and heating system (지열(수온차)냉난방 시스템 효과 분석)

  • Chung, Hoon;Ma, Bum-Gu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.365-368
    • /
    • 2008
  • This experiment is significant because we can provide information by measuring effect of energy saving for whom plan to install a geothermal heat & cooling system. The result shows geothemal system can save about 50% of energy(heating : 35%, cooling : 60%) and we verified that when using curtain can help saving $4{\sim}12%$ of energy additionally

  • PDF

A Study on the Analysis of Energy Performance of High-rise Residential Buildings (초고층 주거건물의 에너지 성능 분석에 관한 연구)

  • Seok Ho-Tae;Kim Jang-Han;Chung Man-Seok
    • Journal of the Korean housing association
    • /
    • v.15 no.4
    • /
    • pp.35-43
    • /
    • 2004
  • The environment pollution is very important problem. Even at the field of architecture, a study about method of saving energy and constructing environment friendly building will have performed with activity. But trends of Korea housing market are changed that the height of building become more higher and the level of comfort going up. Therefore, these requirements force to increase the energy usage for indoor environmental controls. Thus, the purpose of this study is to reduce the heating and cooling energy requirements of High-rise Residential Buildings by the analysis of Energy Performance. From now on, we search improvement plan for the most efficient Energy Saving at present High-rise Residential Buildings.