• 제목/요약/키워드: Energy-saving design standards

검색결과 47건 처리시간 0.025초

에너지 성능지표 기계부문 항목에 따른 업무용 건물의 에너지 절감율 분석 (Analysis of Energy Saving Rate of Office Buildings According to the Items of an EPI Machine Part)

  • 이호진;김서훈;정재욱;장철용;송규동
    • KIEAE Journal
    • /
    • 제13권4호
    • /
    • pp.49-54
    • /
    • 2013
  • released by IEA, 2010, indicated that Korea's GDP, of 8 countries surveyed-Korea, Frans, Germany, Italy, Japan, the UK, the USA, and Australia-was the lowest, but the electric consumption per head was third, following America and Australia. Thus, our government has been striving to reduce energy usage and especially to lessen the energy used in buildings, proposing a variety of road maps such as 'building energy efficiency rating' and 'energy saving design standards of buildings'. Accordingly, this study investigated the effect of the items of machine part among EPI items on the energy saving rate. I measured energy usage by ECO2 program, for simulation program, that is used for the building energy efficiency rating. Result showed that items concerning control of pumps and fans had much more saving rate than the ones concerning efficiency of heater and cooler that had bigger scores assigned among EPI items. Result showed that items concerning control of pumps and fans had much more saving rate than the ones concerning efficiency of heater and cooler that had bigger scores assigned among EPI items. Therefore, I think that grades assigned to items in energy performance index need to be corrected.

지역별 기후에 따른 비주거 건축물 패시브 수준 단열기준 연구 (Study on Insulation Standards at Passive Level of Non-Residential Buildings by Regional Climate)

  • 김예원;유기형
    • 한국태양에너지학회 논문집
    • /
    • 제37권6호
    • /
    • pp.51-58
    • /
    • 2017
  • This study proposes an appropriate level of insulation standards by region through annual heating energy requirements according to regional climate. The reference buildings out of non-residential buildings approved by the energy saving design standard for buildings were derived in the previous study, in which the annual heating energy requirements for each building were as follows when the insulation standard for building members in four regions (Pyeongchang, Seoul, Gwang-ju, and Jeju) suggested by the energy saving design standard for buildings: $29.8kWh/m^2$ in Pyeongchang, $17.5kWh/m^2$ in Seoul, $14.4kWh/m^2$ in Gwangju, and $16.7kWh/m^2$ in Jeju. To satisfy the passive level of insulation standards for these buildings, in case that roof/floor of buildings in Pyeongchang and Seoul was $0.2W/m^2K$, the minimum window thermal transmittance should satisfy $0.9W/m^2K$ and the minimum wall thermal transmittance should satisfy $0.1W/m^2K$ in the case of Pyeongchang. On the other hand, the minimum window thermal transmittance should satisfy $1.5W/m^2K$ and the minimum wall thermal transmittance should satisfy $0.14W/m^2K$ in the case of Seoul. For Jeju regions, the minimum wall thermal transmittance should satisfy $0.34W/m^2K$ to meet the passive level of buildings. Based on the above results, the thermal transmittance of each member by region should take the outdoor climate condition of the region into consideration to satisfy the passive level of buildings.

조경용 식생매트의 열전도율 측정에 관한 연구 (A Study on the Thermal Conductivity Measurement for Planting Mats of Landscaping)

  • 차욱진;양건석
    • 한국조경학회지
    • /
    • 제46권6호
    • /
    • pp.85-96
    • /
    • 2018
  • 선진국들은 지구온난화의 영향을 최소화하기 위해 1997년 '교토의정서' 채택이후 온실가스를 줄이기 위한 다양한 정책을 시행하고 있다. 우리나라 역시 2030년 온실가스 감축 목표를 배출전망치(BAU: Business As Usual) 대비 37% 줄이기 위해 산업부문, 수송부문, 건물부문의 에너지 소비량을 감축하여야 한다. 정부에서는 에너지 소비량 감축을 위한 각종 법령 및 행정규칙을 제정하여 시행하고 있으며, 특히 건물부문의 에너지 소비량을 감축하기 위하여 녹색건축물 조성지원법에 따른 '건축물의 에너지절약설계기준'을 시행하고 있다. 실내온도를 $28^{\circ}C$로 유지하기 위해 사용되는 전력량은 벽면녹화 및 옥상녹화 등으로 녹화된 건물이 녹화되어지지 않은 건축물에 비해 평균 30%의 전력사용량의 감소효과가 있다. 이렇듯 조경녹화에 대한 에너지 절감의 효과는 입증되고 있으나, 이러한 입증은 '건축물의 에너지절약설계기준'에 적합한 방법이 아니기에 에너지 절감의 실효성을 가지고 있지 못한다. 조경용 녹화가 에너지 절감에 따른 실효성을 가지려면 '녹색건축물 조성 지원법 제14조'의 '건축물의 에너지절약 설계기준'의 단열재료에 대하여 구성재료의 열전도율로 열관류율을 계산하여 '별표 1'의 기준에 적합하여야 한다. 본 연구에서는 3종류의 벽면녹화용 식생매트와 1종류의 복합매트(내부단열재+식생매트)를 제작하여 다양한 열전도율 측정 실험을 수행하고, 에너지 보존식을 이용하여 내부단열재 두께 등에 대하여 이론적인 계산을 하였다. 3종류의 식생매트의 열전도율은 0.130~0.157W/mk 정도로서 목재의 열전도율(0.170w/mk)보다 낮아 단열의 기능을 가지는 매트로써 역할을 할 수 있음을 알 수 있었다. 특히, 복합매트는 내부단열재(그라스포, 폴리우레탄 등)의 두께를 조절하면 '건축물의 에너지절약설계기준의' 단열기준 0.051W/mk에 적합한 식생매트가 될 수 있을 것으로 판단된다.

AHP 방법을 이용한 노후학교 에너지절감을 위한 요소기술의 우선순위 결정 (Determining the Priority of Factors for Reducing Energy at Deteriorated School Buildings Using AHP Method)

  • 이상춘;최영준;최율
    • KIEAE Journal
    • /
    • 제11권6호
    • /
    • pp.127-132
    • /
    • 2011
  • Since the late 20th century, countries of the world have made every effort to solve environmental problems due to global warming. The Korean Government has also made various efforts on reducing energy and $CO_2$ emission under the motto of "Low-Carbon Green Growth". In order to achieve the goal to reduce energy in the construction field, severe design standards and regulations on saving energy in new buildings have been established. However, for maximizing the reduction of energy in buildings, it is time to focus on deteriorated buildings where applications of energy saving designs and techniques have been insufficient. Especially, there are little guidelines and researches on reducing energy through remodeling at deteriorated school buildings which were built over 20 years ago. This paper suggests the priority of factors to reduce energy on the remodeling process at deteriorated school buildings using the AHP(Analytic Hierarchy Process) method. For applying the AHP method, the survey of staffs in the Education Offices and board members in the Korea Institute of Ecological Architecture and Environment was conducted via e-mail. As a result, factors of insulation, daylighting, system control, and windows turned out important in the energy reducing remodeling process at deteriorated school buildings, while factors of artificial lighting, solar heating, ventilation, and system did relatively unimportant.

에너지 성능 기반의 기계설비배관 단열기준 개선을 위한 연구 (The Study to Improve the Insulation Standards for Mechanical Pipes based on Energy Performance)

  • 윤희원;류형규
    • 한국지열·수열에너지학회논문집
    • /
    • 제17권4호
    • /
    • pp.28-35
    • /
    • 2021
  • The need for zero-energy building is increasing as a means of actively responding to climate change. Since pipe insulation is a factor that minimizes heat loss of cooling and heating facilities, it is necessary to check pipe insulation standards and prepare improvement plans of preparation for certification of zero energy buildings. In this study, domestic pipe insulation standards were checked to prepare new insulation standards based on energy performance. Through the development of a pipe insulation calculation program, the heat loss according to the insulation thickness of the piping for mechanical facilities was compared and reviewed. As a result, applying the insulation thickness of the KCS standard for the same conditions increased the heat loss by an average of 10% compared to the ASHRAE standard. For this reason, it is necessary to revise the pipe insulation thickness standard in consideration of heat loss due to thermal conductivity and pipe insulation thickness. Using the program in this paper, it is possible to design pipe insulation based on energy performance and help to determine the standard for pipe insulation thickness.

기존 오피스건물 에너지성능지표에 따른 설계기법 연구 (A Study on the Design Technique for Energy Performance Indicators of Existing Office Buildings)

  • 정형태;이유나;김인수;안종욱
    • 에너지공학
    • /
    • 제27권3호
    • /
    • pp.28-35
    • /
    • 2018
  • 세계 각국에서는 환경오염이나 에너지절감을 위한 방안으로 건축물에 대한 가이드라인과 제도적 지원이 활성화되고 있다. 우리나라에서도 2013.09.01. 개정된 "건축물의 에너지절약 설계기준"에 따라 기준들이 마련되고 신축 건축물에 대한 제로에너지빌딩화가 권장사항에서 의무화과정으로 가고 있다. 그럼에도 불구하고 소형건물에 대한 정부의 구속력은 미비한 실정이다. 이에 최근에 시공한 오피스건물(외단열기법 적용)에 대해 에너지 절감효과를 분석하였고 추가적으로 에너지 절감을 위한 이중외피기법을 제안하였다.

공공기관 업무용 건물의 건축물에너지효율등급 인증 현황 분석 (Analysis of the Building Energy Efficiency Rating Certified for Public Office Buildings)

  • 이한솔;김서훈;김종훈;김준태;장철용
    • KIEAE Journal
    • /
    • 제15권5호
    • /
    • pp.75-82
    • /
    • 2015
  • Purpose: The first grade of Korea's Building Energy Efficiency Rating System(BEERS) is required for new government office buildings as a mandatory measure to reduce greenhouse gas emission. However, there is no specific criteria about performance that which level should apply to energy-saving design element for obtaining Building Energy Efficiency Rating 1st grade. Therefore, Certification status should be analyzed firstly, about the office building which is certificated. Certification analysis for office buildings acquired certification therefore should be done first. Method: In this study, Certification status(Office buildings acquired Building Energy Efficiency Rating Certification)was analyzed by classified year, region, specific scale etc. And we analyzed statistically by eliciting an average value of each element influencing to the amount of energy. Result: Energy demands were gradually decreased due to revision of thermal insulation standards for enhanced u-value. Energy consumptions were different from the kind of equipment and yearly trends applied depending on the size of the building. Total primary energy consumptions were influenced by heat source types and the primary energy scale factors.

교육시설 리모델링을 위한 에너지 절감 요소기술의 성능 평가 - 노후 중학교 건물 중심으로 - (Evaluating Performance of Energy Conservation Measures for Remodeling Educational Facilities - Focused on Deteriorated Middle School Buildings -)

  • 이상춘;최영준;최율
    • KIEAE Journal
    • /
    • 제12권4호
    • /
    • pp.105-110
    • /
    • 2012
  • Recently, all of the world are facing with a serious environmental crisis of global warming due to excessive energy consumptions. The Korean Government, taking over 97% of dependence on foreign energy, has made various efforts on reducing energy and greenhouse gas emission under the motto of "Low-Carbon Green Growth". Since the building sector takes 24% of domestic energy consumption, many design standards and regulations on saving energy in new buildings have been established. However, applications of energy saving designs and techniques on the remodeling process at deteriorated buildings including educational ones have been lack. Under a situation where the number of deteriorated schools accounts for up to 50%, this paper evaluated the performances of factors for reducing energy at deteriorated middle school buildings through an energy simulation tool on a standard school model. As a result, among factors of insulation, window's SHGC, southern louver, indoor setup temperature, and system efficiency, all other factors except window's SHGC and southern louver proved contribute to reduce energy at deteriorated middle school buildings, compared with the baseline energy consumption.

친환경 공동주택 구현을 위한 저에너지 설비시스템 통합설계 방안 및 파일럿 프로젝트 계획 (A Pilot Project on the Integrated System Design for Developing the Sustainable Housing Model)

  • 조진균;성재호;신선준;홍민호
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1049-1054
    • /
    • 2009
  • Sustainable housing design can contribute to dramatically reduced energy usage and can be applied to all new building projects. This paper explores the potential in Korea of applying available energy efficient building technologies. The objective was to determine the degree of energy reduction that can easily be achieved in new building design. The pilot project is providing some prototypes with display units which incorporate principles of sustainable design and performance utilizing the eco-design objectives. This building challenges ingrained preconceptions about system designs for four energy saving levels(40%, 60%, 80% and zero energy) and exposes barriers to low energy buildings posed by new standards and guidelines.

  • PDF

건축물의 건강성능에 관한 법적 기준의 기초연구 (A Basic Study of Legal Standards for Building Health Performance)

  • 이현민;유상연;김선국
    • KIEAE Journal
    • /
    • 제9권6호
    • /
    • pp.19-26
    • /
    • 2009
  • In modern architecture, the air-tight construction aimed at saving the energy rather causes ventilation problems and the artificial materials for cost reduction worsen the residential quality. To deal with such negative effect, the study on evaluating the health performance becomes increasingly critical. Among the various factors such as design quality, selected material, construction method and mechanical system that shall be subject to evaluation to identify the health performance of the building, the study was aimed at investigating the legal standards associated with healthy building in various countries. Such evaluation items will provide inputs for an attempt to build legal criteria for a building health performance rating system in Korea.