• 제목/요약/키워드: Energy-optimized control

검색결과 238건 처리시간 0.028초

분포형 압전필름 감지기와 압전세라믹 작동기를 이용한 보의 진동 제어 (Vibration Control of Beam using Distributed PVDF Sensor and PZT Actuator)

  • 유정규;박근영;김승조
    • 소음진동
    • /
    • 제7권6호
    • /
    • pp.967-974
    • /
    • 1997
  • Distributed piezoeletric sensor and actuator have been designed for efficient vibration control of a cantilevered beam. Both PZT and PVDF have been used in this study, the former as an actuator and the latter as a sensor for the integrated structure. We have optimized the position and the size of the PZT actuator and the electrode shape of the PVDF sensor. Finite element method is used to model the structure and the optimized actuators, we have designed the active electrode width of the PVDF sensor along the span of the beam. Actuator design is based on the criterion of minimizing the system energy in the control modes under a given initial condition. Model control forces for the residual (uncontrolled) modes have been minimized during the sensor design to minimize the observation spill-over. Genetic algorithm and sequential quadratic programming technique have been utilized as an optimization scheme. Discrete LQG control law has been applied to the integrated structure for real time vibration control. Performance of the sensor, the actuator, and the integrated smart structure has been demonstrated by experiments.

  • PDF

Semi-active leverage-type isolation system considering minimum structural energy

  • Lin, Tzu-Kang;Lu, Lyan-Ywan;Chen, Chi-Jen
    • Smart Structures and Systems
    • /
    • 제21권3호
    • /
    • pp.373-387
    • /
    • 2018
  • Semi-active isolation systems based on leverage-type stiffness control strategies have been widely studied. The main concept behind this type of system is to adjust the stiffness in the isolator to match the fundamental period of the isolated system by using a simple leverage mechanism. Although this system achieves high performance under far-field earthquakes, it is unsuitable for near-fault strong ground motion. To overcome this problem, this study considers the potential energy effect in the control law of the semi-active isolation system. The minimal energy weighting (MEW) between the potential energy and kinetic energy was first optimized through a series of numerical simulations. Two MEW algorithms, namely generic and near-fault MEW control, were then developed to efficiently reduce the structural displacement responses. To demonstrate the performance of the proposed method, a two-degree-of-freedom structure was employed as a benchmark. Numerical results indicate that the dynamic response of the structure can be effectively dampened by the proposed MEW control under both far-field and near-fault earthquakes, whereas the structural responses resulting from conventional control methods may be greater than those for the purely passive control method. Moreover, according to experimental verifications, both the generic and near-fault MEW control modes yielded promising results under impulse-like earthquakes. The practicability of the proposed control algorithm was verified.

A Low-Computation Indirect Model Predictive Control for Modular Multilevel Converters

  • Ma, Wenzhong;Sun, Peng;Zhou, Guanyu;Sailijiang, Gulipali;Zhang, Ziang;Liu, Yong
    • Journal of Power Electronics
    • /
    • 제19권2호
    • /
    • pp.529-539
    • /
    • 2019
  • The modular multilevel converter (MMC) has become a promising topology for high-voltage direct current (HVDC) transmission systems. To control a MMC system properly, the ac-side current, circulating current and submodule (SM) capacitor voltage are taken into consideration. This paper proposes a low-computation indirect model predictive control (IMPC) strategy that takes advantages of the conventional MPC and has no weighting factors. The cost function and duty cycle are introduced to minimize the tracking error of the ac-side current and to eliminate the circulating current. An optimized merge sort (OMS) algorithm is applied to keep the SM capacitor voltages balanced. The proposed IMPC strategy effectively reduces the controller complexity and computational burden. In this paper, a discrete-time mathematical model of a MMC system is developed and the duty ratio of switching state is designed. In addition, a simulation of an eleven-level MMC system based on MATLAB/Simulink and a five-level experimental setup are built to evaluate the feasibility and performance of the proposed low-computation IMPC strategy.

건물에너지 저감을 위한 향별 슬랫형 블라인드의 최적각도 제어 알고리즘 산출 (Optimized slat angle control algorithm prediction of venetian blind depending on window orientation for energy saving)

  • 권혁주;이금호;이광호
    • KIEAE Journal
    • /
    • 제17권3호
    • /
    • pp.99-106
    • /
    • 2017
  • Purpose: Most modern office buildings adopt the curtain wall system in order to provide occupants with the sense of openness and high-technology, which requires large window area. As a result, the amount of solar radiation increases, negatively affecting cooling load during the summer and increasing energy costs. However, the performance of window itself is not sufficiently controllable parameter to control thermal comfort and solar radiation. Therefore, a shading device such as venetian blind is required to control them and thus a variety of studies have been performed thus far. So, the purpose of this study is to improve the performance of blind through the development of blind control algorithm. Method: Among various input variables for the control of venetian blinds, the vertical solar radiation has been selected in this study as the primary input variable and the optimal control algorithm for venetian blinds were developed for each window orientation. Result: The developed optimal control algorithm has a positive effect on building energy savings.

Auto-focus Control by Chromatic Filtering in Laser Welding

  • Kim, Cheol-Jung;Baik, Sung-Hoon;Kim, Min-Suk;Chung, Chin-Man;Kim, Kwang-Jung
    • Journal of the Optical Society of Korea
    • /
    • 제4권2호
    • /
    • pp.94-99
    • /
    • 2000
  • Optical monitoring using the chromatic aberration of focusing optics is applied to auto-focus control in laser welding. The spectral transmittance of thermal radiation from a weld pool through an aperture depends on the wavelength of the spectral band and on the distance of the weld pool from the focusing optics. Its dependence has been used to monitor the focus shift in laser welding by measuring the spectral band signals filtered by the aperture. The difference between pulsed and continuous laser welding is analyzed. Furthermore, the dependence of the focus shift monitoring on the weld pool size variation is optimized to monitor the focus shift independently from the laser power change at the weld pool. The performance of the auto-focus control with chromatic filtering is presented for pulsed laser welding.

독립형 DC 마이크로그리드의 최적화 설계와 협조적 제어 (Optimized Design and Coordinated Control for Stand-alone DC Micro-grid)

  • 한태희;이지헌;김현준;한병문
    • 전력전자학회논문지
    • /
    • 제18권1호
    • /
    • pp.63-71
    • /
    • 2013
  • This paper describes the coordinated droop control method for stand-alone type DC micro-grid to improve reliability and utilization of distributed generations and energy storage. The stand-alone type DC micro-grid consists of several distributed generations such as a wind power generation, solar power and micro-turbine, and energy storage. The proposed method which is based on autonomous control method shows high reliability and stability through coordinated droop control of distributed generations and energy storage and also capability of battery management. The operation of stand-alone type DC micro-grid was analyzed using detail simulation model with PSCAD/EMTDC software. Based on simulation results, a hardware simulator was built and tested with commercially available components and performance of system was verified.

Coordinated Control Strategy and Optimization of Composite Energy Storage System Considering Technical and Economic Characteristics

  • Li, Fengbing;Xie, Kaigui;Zhao, Bo;Zhou, Dan;Zhang, Xuesong;Yang, Jiangping
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.847-858
    • /
    • 2015
  • Control strategy and corresponding parameters have significant impacts on the overall technical and economic characteristics of composite energy storage systems (CESS). A better control strategy and optimized control parameters can be used to improve the economic and technical characteristics of CESS, and determine the maximum power and stored energy capacity of CESS. A novel coordinated control strategy is proposed considering the coordination of various energy storage systems in CESS. To describe the degree of coordination, a new index, i.e. state of charge coordinated response margin of supercapacitor energy storage system, is presented. Based on the proposed control strategy and index, an optimization model was formulated to minimize the total equivalent cost in a given period for two purposes. The one is to obtain optimal control parameters of an existing CESS, and the other is to obtain the integrated optimal results of control parameters, maximum power and stored energy capacity for CESS in a given period. Case studies indicate that the developed index, control strategy and optimization model can be extensively applied to optimize the economic and technical characteristics of CESS. In addition, impacts of control parameters are discussed in detail.

A Study on Constant Power Control of Half Bridge Inverter for Microwave Oven

  • Lee, Min-Ki;Koh, Kang-Hoon;Lee, Hyun--Woo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제4B권2호
    • /
    • pp.73-79
    • /
    • 2004
  • For the global microwave market, high RF power or deluxe model is applying for inverter gradually. In this paper, 120[V]/1200[W] high power inverter is proposed and verified by an optimized design of PFM type. Especially the steady power output control was fulfilling at +/- 10[%] input voltage variation.

성능이 향상된 면적선량계(DAP) 개발 (Development of Enhanced DAP(Dose Area Product))

  • 이영지;이상헌;이승호
    • 전기전자학회논문지
    • /
    • 제23권2호
    • /
    • pp.739-742
    • /
    • 2019
  • 본 논문에서는 성능이 향상된 면적선량계(DAP)를 제안한다. 본 논문에서 제안한 성능이 향상된 면적선량계는 기존에 개발되었던 면적선량계를 최적화하였다. 성능이 향상된 면적선량계는 전하 적분기 및 ADC 회로의 최적화 설계, RS-485 통신용 Line transceiver의 최적화 설계, Display 회로의 최적화 설계, 연동 및 에이징을 위한 PC 기반 제어 프로그램 최적화 등을 수행하였다. 제안된 시스템의 성능을 평가하기 위하여 공인시험기관에서 실험한 결과는 Radiation dose dependence와 Radiation quality dependence는 4.2%의 측정 불확도가 측정되어 국제 표준인 ${\pm}15%$ 이하에서 정상동작 됨이 확인되었다. Energy range/Tube voltage는 30~150kV 구간에서 반응이 확인되었다. 센서필드간 감도차이와 센서필드간 면적선량 감도차이는 4.3%의 측정 불확도가 측정되어 국제 표준인 ${\pm}15%$ 이하에서 정상동작 됨이 확인되었다. 면적선량계의 재현성을 측정하기 위하여 10회 반복하여 측정한 결과 0%로 확인되어서 IEC60580 권고 사항인 2% 이하에서 정상동작 됨이 확인되었다. Digital resolution은 시간당 기준선량에 대해 오차 범위 내에서 $0.01{\mu}Gy{\cdot}m^2$의 최소단위로 측정되는 것을 확인되었다.

분포형 압전 필름 감지기와 압전 세라믹 작동기를 이용한 보의 진동 제어 (Vibration Control of Beam using Distributed PVDF sensor and PZT actuator)

  • 박근영;유정규;김승조
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1997년도 춘계학술대회논문집; 경주코오롱호텔; 22-23 May 1997
    • /
    • pp.413-417
    • /
    • 1997
  • Distributed piezoelectric sensor and actuator have been designed for efficient vibration control of a cantilevered beam. Both PZT and PVDF are used in this study, the former as an actuator and the latter as a sensor for our integrated structure. For the PZT actuator, the position and size have been optimized. Optimal electrode shape of the PVDF sensor has been determined. For multi-mode vibration control, we have used two PZT actuators and a PVDF sensor. Electrode shading of PVDF is more powerful for modal force adjustment than the sizing and positioning of PZT. Finite element method is used to model the structure that includes the PZT actuator and the PVDF sensor. By deciding on or off of each PZT segment, the length and the location of the PZT actuator are optimize. Considering both of the host structure and the optimized actuators, it is designed that the active electrode width of PVDF sensor along the span of the beam. Actuator design is based on the criterion of minimizing the system energy in the control modes under a given initial condition. Sensor is designed to minimize the observation spill-over. Modal control forces for the residual(uncontrolled) modes have been minimized during the sensor design. Genetic algorithm, which is suitable for this kind of discrete problems, has been utilized for optimization. Discrete LQG control law has been applied to the integrated structure for real time vibration control. Performance of the sensor, the actuator, and the integrated smart structure has been demonstrated by experiments.

  • PDF