• Title/Summary/Keyword: Energy total operation

Search Result 437, Processing Time 0.032 seconds

Study on Feasibility of Integrated Two-Phase Anaerobic Digestion Using Foodwaste Water by Reviewing of Operating Efficiency (일체형 2상 혐기성소화 운전효율 검토를 통한 음폐수 처리 타당성에 관한 연구)

  • Song, Hancheul;Kim, Dongwook
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.24 no.2
    • /
    • pp.59-66
    • /
    • 2016
  • The purpose of this study was to review of technical, economical feasibilities regarding Integrated Two-Phase Anaerobic Digestion(ITPAD) method. In order for that, operation conditions and data with 24tpd capacity of operating ITPAD plant were analyzed. The result showed that VS removal efficiency was 73.7% and total amount of biogas was generated $1,239m^3/day$ on the average that represents $54.4m^3/ton$-input of generation efficiency. ITPAD had advantages in terms of required area and energy for heating which were analyzed 15.9%~47%, 11.6%~17.8% lower respectively compared to Conventional Separated Two-Phase Anaerobic Digestion(CSTPAD) method. Thus, it is considered the ITPAD has comparatively high feasibility to be expanded and commercialized to dispose high concentration organic matter of waste such as food waste and its leachate.

A Study on the V2G Application using the Battery of Electric Vehicles under Smart Grid Environment (스마트그리드 환경에서 전기자동차 배터리를 이용한 V2G의 활용방안에 관한 연구)

  • Choi, Jin-Young;Park, Eun-Sung
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.1
    • /
    • pp.40-45
    • /
    • 2014
  • This study examines the system and process of battery stored energy in vehicles and suggest the effective area for the use of V2G(vehicle-to-grid) from Jeju Smart Grid Demonstration Project. V2G means technology of electric power transmission from the battery of electric-drive vehicles to state grid. As for the increasing of effectiveness for demand-side control, V2G is a very good alternative. In the U.S., the utilization of electric vehicles is under 40% on average. In this case, we can use he battery of electric vehicle as role of frequency regulation or generator of demand-side resource. V2G, which is the element of Smart Transportation, consists of electric vehicle battery, BMS(battery management system), OBC(on-board charger), charging infrastructure, NOC(network operating center) and TOC(total operation center). V2G application has been tested for frequency regulation to secure the economical efficiency in the United States. In this case, the battery cycle life is not verified its disadvantage. On the other hand, Demand Response is required by low c-rate of battery in electric vehicle and It can be small impact on the battery cycle life. This paper concludes business area of demand response is more useful than frequency regulation in V2G application of electric vehicles in Korea. This provides the opportunity to create a new business for power grid administrator with VPP(virtual power plant).

A Study on Estimation Method for Optimal Composition Rate of Hybrid ESS Using Lead-acid and Lithium-ion Batteries (연축전지와 리튬이온전지용 하이브리드 ESS의 최적구성방안에 관한 연구)

  • Park, Soo-Young;Ryu, Sang-Won;Park, Jae-Bum;Kim, Byung-Ki;Kim, Mi-Young;Rho, Dae-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.6
    • /
    • pp.962-968
    • /
    • 2016
  • The large scaled lead-acid battery is widely used for efficient operation of the photovoltaic system in many islands. However, lithium-ion battery is now being introduced to mitigate the fluctuation of wind power and to replace lead-acid battery. Therefore, hybrid ESS(Energy Storage system) that combines lithium-ion battery with lead-acid battery is being required because lithium-ion battery is costly in present stage. Under this circumstance, this paper presents the optimal algorithm to create composition rate of hybrid ESS by considering fixed and variable costs in order to maximize advantage of each battery. With minimization of total cost including fixed and variable costs, the optimal composition rate can be calculated based on the various scenarios such as load variation, life cycle and cost trend. From simulation results, it is confirmed that the proposed algorithms are an effective tool to produce a optimal composition rate.

Design and Implementation of Transcutaneous Electrical Nerve Stimulation System for the Integration with Mobile Phone (휴대폰 내장을 위한 경피신경 자극치료기의 설계 및 구현)

  • Woo Sang-Hyo;Yoon Ki-Won;Lee Jyung-Hyun;Park Hee-Joon;Won Chul-Ho;Cho Jin-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.9 no.3
    • /
    • pp.360-368
    • /
    • 2006
  • Recently, performance of the mobile phone has increased dramatically. Due to this, it is possible to integrate various biotechnology. There are many ventures to integrate biotechnology with mobile phone, because of increasement interest of peoples well-being. The transcutaneous electrical nerve stimulation can Improve the circulation of blood and suppress a pain. To integrate the transcutaneous electrical nerve stimulation with mobile phone, it is necessity to make small, low power, and safe module. In this paper, the transcutaneous electrical nerve stimulation module is designed and implemented by small boost convertor. The value of tank capacitor, which is the total stimulus energy to human, can be chosen to insure safe condition. The confirm the of operation of designed module, a small micro-controller is used to make system and test the module. The implemented system is small and consumes a low enough power to be integrated with mobile phone.

  • PDF

Lean Combustion Characteristics with Hydrogen Addition in a LPG Fuelled Spark Ignition Engine (LPG엔진에서 수소연료 보조분사에 의한 희박연소특성 연구)

  • Oh, Seung-Mook;Kim, Chang-Up;Kang, Kern-Yong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.2
    • /
    • pp.114-120
    • /
    • 2006
  • The basic effects of hydrogen addition for engine performance and emission were investigated in single cylinder research engine. Seven commercial injectors were tested to choose a suitable injector for hydrogen injection prior to its engine implementation. The hydrogen fuel leakage and flow rate were evaluated for each injector and KN3-1(Keihin, CO.) showed the best performance for hydrogen fuel. At the higher excess air ratio(${\lambda}=1.7$, 2.0), the better combustion stability was found with hydrogen addition even though its effect was small at lower excess air ratio (${\lambda}=1.0$, 1.3). Stable operation of the engine was even guaranteed at ${\lambda}=2.0$, if the amount of hydrogen gas was near 15% of total energy. In the lean region, ${\lambda}>1.3$, thermal efficiency was improved slightly while it was not clearly observed at ${\lambda}=1.0$, 1.3. It is considered that, in some cases, high temperature environment due to hydrogen combustion caused further heat loss to surroundings. Except for ${\lambda}=1.0$, with larger amount of hydrogen addition, CO was reduced drastically but it was emitted more at the leaner region. Nitric oxides(NOx) was increased a little more with hydrogen addition at ${\lambda}=1.0$, 1.3. However, at ${\lambda}>1.3$ its relative amount of emission was low. In addition, the amount of NOx was continuously decreased with hydrogen addition, but, at ${\lambda}=2.0$ the amount of NOx was lowered to 1/100 of that of ${\lambda}=1.0$. THC emission was significantly increased as air/fuel ratio was raised to leaner region due to misfire and partial burn.

Design for seawater reverse osmosis plant using water blending in smart water grid (스마트 워터 그리드 내에서 워터 블렌딩을 고려한 역삼투 해수담수화 플랜트 설계)

  • Lee, Hongju;Park, Hanbai;Woo, Dal-Sik;Kim, Suhan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.1
    • /
    • pp.89-96
    • /
    • 2015
  • Smart water grid is a water network with communication to save water and energy using various water resources. In smart water grid, water product from the various sources can be blended to be supplied to end-users. The product water blending was reported by literatures while feed water blending has been rarely reported so far. In this work, a commercial reverse osmosis (RO) system design software provided by a membrane manufacturer was used to elucidate the effect of feed water blending on the performance of seawater reverse osmosis (SWRO) plant. Fresh water from exisiting water resource was assumed to be blended to seawater to decrease salt concentration of the RO feed water. The feed water blending can simplify the RO system from double to single pass and decrease seawater intake amount, the unit prices of the RO system components including high pressure pump, and operation risk. Due to the increase in RO plant capacity with the feed water blending, however, the RO membrane area and total power consumption increase at higher water blending rates. Therefore, a specific benefit-cost analysis should be carried out to apply the feed water blending to SWRO plants.

Analysis of the Economic Efficiency of the District Heating and Gas Engine Co-Generation System Compared with the Central Heating System (중앙난방방식을 지역난방과 소형열병합난방 방식으로 전환 시 경제성 비교 분석)

  • Kim, Kyu Saeng
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.10
    • /
    • pp.544-551
    • /
    • 2015
  • This study was conducted to determine the LCC of apartment complexes with district heating and a cogeneration system. For the purpose of analyzing LCC according to the size of the apartment complex, 500, 1,500, and 4,000-unit model apartments were selected. Analysis was performed on the design of the heating system and the life cycle cost including total construction cost, maintenance and operation cost for the duration of the project period (15 years). According to the calculated results, 1) The initial cost of the cogeneration system for 500, 1,500, and 4,000-unit apartments is higher than that of the district heating system by 20%, 13%, and 12%, respectively. 2) In the case of the cogeneration system, the payback period by electric generation was found to be 5.21, 4.92 and 4.47 years, and saving cost was calculated to be 29 billion won, 94 billion won and 262 billion won after the payback period for 500, 1,500, and 4,000-unit apartments, respectively. 3) The LCC values of the cogeneration system were 1.12, 1.07 and 1.06 times larger than those of the district system according to the size of the apartment complex. In this study, the district heating system was found to be more efficient than the cogeneration system in terms of LCC reduction. 4) District heating is affected by fuel bills, so energy efficiency should be improved through recovering waste heat (incineration heat, etc.). Also, district cooling should be provided according to heat use to keep the temperature high in winter and low in summer.

Eigenvalue Analysis and Detection of Low Frequency Oscillation using PMU Data in KEPCO System (위상동기신호를 이용한 한전계통의 저주파진동 검출과 고유치해석)

  • Shim, Kwan-Shik;Kim, Sang-Tae;Kim, Tae-Kyun;Ahn, Seon-Ju;Choi, Joon-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.2
    • /
    • pp.261-284
    • /
    • 2017
  • This paper describes the results of a low-frequency oscillation analysis using data measured in PMU installed in the KEPCO system, and the comparison with eigenvalues computed from the linear model. The dominant oscillation modes are estimated by applying various algorithms. The algorithms are: the extended Prony method; multiple time interval parameter estimation method; subspace system identification method; and spectral analysis. From the measurement data, modes of frequency 0.68[Hz] and 0.92[Hz] were estimated, and modes of frequency 0.63[Hz] and 0.80[Hz] were computed from the eigenvalue calculation. There was a difference between the mode estimated from measurement data and that from the linear model. This is possibly because of an error in the dynamic data of the KEPCO system used in eigenvalue calculation. Because wide area modes exist in the KEPCO system, these modes should be monitored continuously for the reliable operation of the system. In order to prevent total blackouts caused by wide area oscillation, moreover, contingency analysis should be performed in relation to this mode and appropriate measures should be established.

Emission Characteristics of Fine Particles from Thermal Power Plants (화력발전소의 미세먼지 배출특성)

  • Park, Sooman;Lee, Gayoung
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.4
    • /
    • pp.455-460
    • /
    • 2020
  • In order to identify the characteristics of fine particle emissions from thermal power plants, this study conducted measurement of the primary emission concentration of TPM, PM10 and PM2.5 according to Korea standard test method (ES 01301.1) and ISO 23210 method (KS I ISO 23210). Particulate matters were sampled in total 74 units of power plants such as 59 units of coal-fired power plants, 7 units of heavy oil power plants, 2 units of biomass power plant, and 6 units of liquid natural gas power plants. The average concentration of TPM, PM10, PM2.5 by fuel are 3.33 mg/m3, 3.01 mg/m3, 2.70 mg/m3 in coal-fired plant, 3.02 mg/m3, 2.99 mg/m3, 2.93 mg/m3 in heavy oil plant, 0.114 mg/m3, 0.046 mg/m3, 0.036 mg/m3 in LNG plant, respectively. These results of TPM, PM10 and PM2.5 were satisfied with the standards of fine dust emission allowance in all units of power plants, respectively. Also, this study evaluated the characteristics of fine particle emissions by conditions of power plants including generation sources, boiler types and operation years and calculated emission factors and then evaluated fine particle emissions by sources of electricity generation.

Life Cycle Assessment of Rural Community Buildings Using OpenLCATM DB (OpenLCATM DB를 이용한 농촌 공동체 건축물 전과정평가)

  • Kim, Yongmin;Lee, Byungjoon;Yoon, Seongsoo
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.63 no.3
    • /
    • pp.97-105
    • /
    • 2021
  • Most of the rural development projects for the welfare of residents are mainly new construction and remodeling projects for community buildings such as village halls and senior citizens. However, in the case of the construction industry, it has been studied that 23% of the total carbon dioxide emissions generated in Korea are generated in the building-related sector. (GGIC, 2015) In order to reduce the emission of environmental pollutants resulting from construction of rural community buildings, there is a need to establish a system for rural buildings by predicting the environmental impact. As a result of this study, the emissions of air pollutants from buildings in rural communities were analyzed by dividing into seven stages: material production, construction, operation, maintenance, demolition, recycling, and transportation activities related to disposal. As a result, 12 kg of carbon dioxide (CO), 0.06 kg of carbon monoxide (CO), 0.02 kg of methane (CH), 0.04 kg of nitrogen oxides (NO), 0.02 kg of sulfurous acid gas (SO), and non-methane volatile organics per 1m of buildings in rural communities It was analyzed that 0.02 kg of compound (NMVOC) and 0.00011 kg of nitrous oxide (NO) were released. This study proved that environmentally friendly design is possible with a quantitative methodology for the comparison of operating energy and air pollutant emissions through the design specification change based on the statement of the rural community building. It is considered that it can function as basic data for further research by collecting major structural changes and materials of rural community buildings.